RESUMO
Out of hospital cardiac arrest (OHCA) is encountered on a regular basis in prehospital care. Specific guidelines exist for cardiopulmonary resuscitation. Guidelines cover most related situations but cannot cover all of them. This article reports on a 71-year-old man who suffered an OHCA. Persisting gasping and recurrent ventricular fibrillation made the prehospital management difficult and imposed challenges on the whole team. The guidelines provided no answers to this specific situation. Wittingly, the emergency physician decided to abandon the standard approach. Based on this case, this article discusses the pathophysiological considerations and an approach deviating from the standard approach, which could have led to a positive patient outcome without casting doubt on the current resuscitation guidelines.
Assuntos
Reanimação Cardiopulmonar/normas , Parada Cardíaca Extra-Hospitalar/terapia , Idoso , Cardioversão Elétrica , Serviços Médicos de Emergência/normas , Coração , Humanos , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como AssuntoRESUMO
BACKGROUND: Increased vascular permeability is a characteristic feature of sepsis which, in the past, has been ascribed exclusively to a malfunction of endothelial cells. However, recently it has become evident that the endothelial glycocalyx is of considerable importance concerning various aspects of vascular physiology, e.g. the vascular barrier and inflammation. Heparan sulfate, one of its essential components is characteristically traceable in blood, in case the endothelial glycocalyx is damaged or destroyed. METHODS: In 15 pigs we investigated whether the administration of endotoxin from gram-negative bacteria (Escherichia coli) results in increased serum levels of heparan sulfate, signalizing a shedding of the glycocalyx. In addition, markers of inflammation (white blood cell count, platelet count, tumour necrosis factor-α and interleukin-6) were evaluated over an observation period of 6 hours. RESULTS: Serum heparan sulfate concentrations significantly increased over time in the endotoxin group and were significantly elevated in comparison to the control group 6 hours after administration of endotoxin (p<0.001). In the endotoxin group all markers of inflammation significantly changed during the time course. CONCLUSIONS: The administration of bacterial endotoxin induced a significant rise in degradation products of the endothelial glycocalyx.
Assuntos
Endotoxemia/sangue , Heparitina Sulfato/sangue , Animais , Endotélio Vascular/química , Endotoxemia/induzido quimicamente , Endotoxinas , Glicocálix/química , SuínosRESUMO
BACKGROUND: Halogenated anaesthetics have been shown to reduce ischaemia-reperfusion injuries in various organs due to pre- and post-conditioning mechanisms. We compared volatile and total intravenous anaesthesia with regard to their effect on remote pulmonary injury after thoracic aortic occlusion and reperfusion. METHODS: Eighteen pigs were randomized after sternotomy and laparotomy (fentanyl-midazolam anaesthesia) to receive either sevoflurane or propofol in an investigator-blinded fashion. Ninety minutes of thoracic aortic occlusion was induced by a balloon catheter. During reperfusion, a goal-directed resuscitation protocol was performed. After 120 min of reperfusion, the anaesthetic regimen was changed to fentanyl-midazolam again for another 180 min. The oxygenation index and intra-pulmonary shunt fractions were calculated. After 5 h of reperfusion, a bronchoalveolar lavage was performed. The total protein content and lactate dehydrogenase activity were measured in epithelial lining fluid (ELF). Alveolar macrophage oxidative burst was analysed. The wet to dry ratio was calculated and tissue injury was graded using a semi-quantitative score. Ten animals (n=5 for each anaesthetic) without aortic occlusion served as time controls. RESULTS: The oxygenation index decreased and the intra-pulmonary shunt fraction increased significantly in both occlusion groups. There were no significant differences between sevoflurane and propofol with respect to the oxygenation index, ELF composition, morphologic lung damage, wet to dry ratio and alveolar macrophage burst activity. Differences were, however, seen in terms of systemic haemodynamic stability, where catecholamine requirements were less pronounced with sevoflurane. CONCLUSION: We conclude that the severity of remote lung injury was not different between sevoflurane and propofol anaesthesia in this porcine model of severe lower-body ischaemia and reperfusion injury.
Assuntos
Aorta Torácica/fisiopatologia , Arteriopatias Oclusivas/complicações , Éteres Metílicos/uso terapêutico , Propofol/uso terapêutico , Traumatismo por Reperfusão/prevenção & controle , Síndrome do Desconforto Respiratório/prevenção & controle , Anestesia/métodos , Anestésicos Inalatórios/uso terapêutico , Anestésicos Intravenosos/uso terapêutico , Animais , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Pressão Sanguínea/efeitos dos fármacos , Modelos Animais de Doenças , Pulmão/irrigação sanguínea , Pulmão/efeitos dos fármacos , Pulmão/patologia , Síndrome do Desconforto Respiratório/etiologia , Síndrome do Desconforto Respiratório/fisiopatologia , Índice de Gravidade de Doença , Sevoflurano , Suínos , Fatores de Tempo , Resistência Vascular/efeitos dos fármacosRESUMO
BACKGROUND: Left ventricular stroke volume variation (SVV) or its surrogates are useful tools to assess fluid responsiveness in mechanically ventilated patients. So far it is unknown, how changes in cardiac afterload affect SVV. Therefore, this study compared left ventricular SVV derived by pulse contour analysis with SVV measured using an ultrasonic flow probe and investigated the influence of cardiac afterload on left ventricular SVV. METHODS: In 13 anaesthetized, mechanically ventilated pigs [31(SD 6) kg], we compared cardiac output (CO), stroke volume (SV), and SVV determined by pulse contour analysis and by an ultrasonic aortic flow signal (Bland-Altman analysis). After obtaining baseline measurements, cardiac afterload was increased using phenylephrine and decreased using adenosine (both continuously administered). Measurements were performed with a constant tidal volume (12 ml kg-1) without PEEP. RESULTS: Neither increasing mean arterial pressure (MAP) [from 59 (7) to 116 (19)] nor decreasing MAP [from 63 (7) to 39 (4)] affected CO, SV, and SVV (both methods). Method comparison revealed a bias for SVV of 0.1% [standard error of the mean (SE) 0.8] at baseline, -1.2% (SE 0.8) during decreased and 4.0% (SE 0.7) during increased afterload, the latter being significantly different from the others (P<0.05). Thereby, pulse contour analysis tended to underestimate SVV during decreased afterload and to overestimate SVV during increased afterload. Limits of agreement were approximately 6% for all points of measurement. CONCLUSIONS: Left ventricular SVV is not affected by changes in cardiac afterload. There is a good agreement of pulse contour with flow derived SVV. The agreement decreases, if afterload is extensively augmented.
Assuntos
Débito Cardíaco/fisiologia , Monitorização Fisiológica/métodos , Volume Sistólico/fisiologia , Animais , Pressão Sanguínea/fisiologia , Hidratação/métodos , Respiração com Pressão Positiva , Pulso Arterial , Processamento de Sinais Assistido por Computador , Suínos , Termodiluição , Função Ventricular Esquerda/fisiologiaRESUMO
BACKGROUND: Thoraco-abdominal-aneurysm surgery predicts high mortality. Propofol and sevoflurane are commonly used anaesthetics for this procedure. Halogenated anaesthetics induce organ protection similar to ischaemic preconditioning. We investigated which anaesthetic regimen would lead to a better protection against ischaemia-reperfusion injury induced by temporary thoracic-aortic occlusion. METHODS: Following initial fentanyl-midazolam anaesthesia for surgical preparation, 18 pigs were randomly assigned to two groups: group one received propofol (n=9) and group two sevoflurane (n=9) before, during, and after lower body ischaemia in an investigator blinded fashion. Ten animals without aortic occlusion served as time controls (propofol, n=5; sevoflurane, n=5). For induction of ischaemia, the thoracic aorta was occluded by a balloon-catheter for 90 min. After 120 min of reperfusion, the study anaesthetics were discontinued and fentanyl-midazolam re-established for an additional 180 min. Goal-directed therapy was performed during reperfusion. Fluid and catecholamine requirements were assessed. Serum samples and intestinal tissue specimens were obtained. RESULTS: Severe declamping shock occurred in both study groups. While norepinephrine requirements in the sevoflurane group were significantly reduced during reperfusion (P<0.05), allowing cessation of catecholamine support in 4/9 animals, all 9/9 animals were still catecholamine dependent at the end of the experiment in the propofol group. Serum activities of lactate dehydrogenase, aspartate transaminase, and alanine aminotransferase were lower with sevoflurane (P<0.05). Small intestine tissue specimens did not differ histologically. CONCLUSIONS: Use of sevoflurane compared with propofol attenuated the haemodynamic sequelae of reperfusion injury in our model. Release of serum markers of cellular injury was also attenuated.
Assuntos
Aneurisma da Aorta Torácica/cirurgia , Éteres Metílicos/uso terapêutico , Propofol/uso terapêutico , Traumatismo por Reperfusão/prevenção & controle , Anestésicos Inalatórios/uso terapêutico , Anestésicos Intravenosos/uso terapêutico , Animais , Pressão Sanguínea/efeitos dos fármacos , Constrição , Esquema de Medicação , Enzimas/sangue , Epinefrina/administração & dosagem , Feminino , Jejuno/patologia , Lactatos/sangue , Masculino , Norepinefrina/administração & dosagem , Consumo de Oxigênio/efeitos dos fármacos , Pressão Propulsora Pulmonar/efeitos dos fármacos , Distribuição Aleatória , Traumatismo por Reperfusão/etiologia , Traumatismo por Reperfusão/patologia , Traumatismo por Reperfusão/fisiopatologia , Sevoflurano , Suínos , Vasoconstritores/administração & dosagemRESUMO
BACKGROUND AND OBJECTIVE: Measurement of central blood volumes (CBV), such as global end-diastolic volume (GEDV) and right ventricular end-diastolic volume (RVEDV) are considered appropriate estimates of intravascular volume status. However, to apply those parameters for preload assessment in mechanically ventilated patients, the influence of tidal volume (TV) and positive endexpiratory airway pressure (PEEP) on those parameters must be known. METHODS: In 13 mechanically ventilated piglets, the effect of low (10 mL kg(-1)) and high (20 mL kg(-1)) TVs on CBV was investigated in absence and presence of PEEP (0 and 15 cm H(2)O). GEDV, RVEDV, right heart (RHEDV) and left heart end-diastolic volume (LHEDV) were measured by thermodilution. Blood flow on the descending thoracic aorta measured with an ultrasonic flow-probe served to determine stroke volume (SV). Measurements were performed during baseline conditions, after volume loading with previously extracted haemodilution blood (20 mL kg(-1)) and following haemorrhage (30 mL kg(-1)). RESULTS: Application of PEEP decreased GEDV and SV significantly (P < 0.05). Augmenting TV did not reduce GEDV systematically, but significantly reduced SV (P < 0.05). Changes in ventilator settings only influenced RVEDV following volume loading (P < 0.05). RHEDV and LHEDV decreased following application of PEEP, but only RHEDV decreased after augmenting TV at baseline and following volume loading. Correlation of SV with parameters of CBV was r = 0.487 (P < 0.01) for GEDV, r = 0.553 (P < 0.01) for RVEDV, r = 0.596 (P < 0.01) for RHEDV and r = 0.303 (P < 0.01) for LHEDV. CONCLUSION: Application of PEEP decreases CBV and SV. Augmenting TV reduces SV but not CBV. There is a moderate correlation between parameters of CBV and cardiac performance.
Assuntos
Volume Sanguíneo/fisiologia , Respiração com Pressão Positiva , Respiração Artificial/métodos , Volume de Ventilação Pulmonar/fisiologia , Animais , Modelos Animais , Monitorização Fisiológica/métodos , Respiração com Pressão Positiva/métodos , Estatística como Assunto , Sus scrofa , Termodiluição/métodosRESUMO
BACKGROUND: Hemodilution reduces hematocrit (Hct) and blood oxygen content. Tissue oxygenation is mainly preserved by increased cardiac output. As myocardial O2-demands increase, coronary vasodilatation becomes necessary to increase myocardial blood flow. Myocardial ischemia occurs at a critical Hct-value (Hctcrit), with accompanying exhaustion of coronary reserve. Hyperoxic ventilation is known to both reverse peripheral tissue hypoxia at Hctcrit and also to induce coronary vasoconstriction. This study aimed to determine whether hyperoxic ventilation at Hctcrit further exacerbates myocardial ischemia and dysfunction. METHODS: Nine anesthetized pigs ventilated on room air were hemodiluted by 1:1 exchange of blood with pentastarch (6%HES) to Hctcrit, defined as onset of myocardial ischemia (ECG changes). At Hctcrit, hyperoxic ventilation was started. Measurements were performed at baseline, at Hctcrit, and after 15 min of hyperoxic ventilation. We determined myocardial blood flow (microsphere method), arterial O2-content, subendocardial O2-delivery and myocardial function (left ventricular pressure increase). RESULTS: At Hctcrit 7 (6;8)%, O2-content was reduced [3.7 (3.1;3.9) ml dl(-1)]. Despite a compensatory increase of myocardial blood flow [531 (449;573), ml min(-1)100 g(-1)], all pigs displayed myocardial ischemia and compromised myocardial function (P < 0.05). Hyperoxic ventilation produced increased coronary vascular resistance secondary to vasoconstriction, and reduced myocardial blood flow [426 (404;464), ml min(-1)100 g(-1); P < 0.05]. Myocardial oxygenation was found to be maintained by increased O2-content [4.4 (4.2;4.8), ml dl(-1); P < 0.05], the contribution of dissolved O2 to subendocardial O2-delivery increased (32 vs. 8%; P < 0.05), which preserved myocardial function. CONCLUSION: Hyperoxic ventilation at Hctcrit is followed by coronary vasoconstriction and reduction of coronary blood flow. However, myocardial oxygenation and function is maintained, as increased O2-content (in particular dissolved O2) preserves myocardial oxygenation.
Assuntos
Circulação Coronária/efeitos dos fármacos , Coração/fisiopatologia , Hiperóxia/fisiopatologia , Oxigenoterapia , Respiração Artificial , Animais , Eletrocardiografia/efeitos dos fármacos , Testes de Função Cardíaca , Hematócrito , Hemodiluição , Derivados de Hidroxietil Amido/uso terapêutico , Isquemia Miocárdica/fisiopatologia , Consumo de Oxigênio/fisiologia , Oxigenoterapia/efeitos adversos , Substitutos do Plasma/uso terapêutico , Suínos , Resistência Vascular/fisiologia , Vasoconstrição/fisiologia , Função Ventricular Esquerda/fisiologiaRESUMO
Although inhaled nitric oxide (NO(i)) is considered to act selectively on pulmonary vessels, EEG abnormalities and even occasional neurotoxic effects of NO(i) have been proposed. Here, we investigated cerebrovascular effects of increasing concentrations of 5, 10 and 50 ppm NO(i) in seven anesthetized pigs. Cerebral hemodynamics were assessed non-invasively by use of near-infared spectroscopy and indicator dilution techniques. NO(i) increased cerebral blood volume significantly and reversibly. This effect was not attributable to changes of macrohemodynamic parameters or arterial blood gases. Simultaneously, cerebral transit time increased while cerebral blood flow remained unchanged. These data demonstrate a vasodilatory action of NO(i) in the cerebral vasculature, which may occur preferentially in the venous compartment.
Assuntos
Artérias Cerebrais/efeitos dos fármacos , Circulação Cerebrovascular/efeitos dos fármacos , Óxido Nítrico/farmacologia , Vasodilatação/efeitos dos fármacos , Anestésicos/farmacologia , Animais , Artérias Cerebrais/fisiologia , Circulação Cerebrovascular/fisiologia , Vias de Administração de Medicamentos , Feminino , Hemodinâmica , Masculino , Tempo de Reação/efeitos dos fármacos , Tempo de Reação/fisiologia , Sus scrofa , Vasodilatação/fisiologiaRESUMO
OBJECTIVE: During normovolaemic haemodilution arterial O(2)-content decreases exponentially. Nevertheless, tissue oxygenation is first maintained initially by increased organ perfusion and O(2)-extraction. As soon as these compensatory mechanisms are exhausted, myocardial ischaemia and tissue hypoxia occur at an individual 'critical' haematocrit (Hct) value. This study was conducted in order to assess whether tissue hypoxia at the critical Hct is reversed by hyperoxic ventilation with 100% O(2). METHOD: Eighteen anaesthetized pigs were ventilated with room air and were hemodiluted by 1:1 exchange of blood with 6% pentastarch to their individual critical Hct (onset of myocardial ischaemia; significant ECG changes). At the critical Hct, hyperoxic ventilation was initiated. In nine complete datasets, global O(2) delivery and consumption, local tissue O(2) partial pressure (tpO(2)) (MDO-Electrode, Eschweiler, Kiel, Germany) and organ blood flow (microsphere method) in skeletal muscle were analyzed at baseline, after haemodilution to the critical Hct and after 15 min of hyperoxic ventilation. RESULTS: At the critical Hct (7.2+/-1.2%), tpO(2) was reduced from 23+/-3 to 10+/-2 Torr with 50% of all values in the hypoxic range (<10 Torr, all P<0.05). During hyperoxic ventilation, contribution of physically dissolved O(2) to the O(2) delivery and O(2) consumption increased by 400 and 563% (P<0.05) and instantly restored tpO(2) to 18+/-2 Torr, (hypoxic values 25%, P<0.05). CONCLUSION: Hyperoxic ventilation reversed tissue hypoxia at the critical Hct due to preferential utilization of plasma O(2) and allowed temporary preservation of tissue oxygenation. During haemodilution, hyperoxic ventilation might offer an effective bridge until red cells are ready for transfusion.
Assuntos
Hematócrito , Hemodiluição , Oxigenoterapia , Oxigênio/sangue , Animais , Hipóxia Celular , Circulação Coronária , Eletrocardiografia , Hemodiluição/efeitos adversos , Hemodinâmica , Hiperóxia , Músculo Esquelético/metabolismo , Isquemia Miocárdica/sangue , Isquemia Miocárdica/metabolismo , Isquemia Miocárdica/fisiopatologia , Consumo de Oxigênio , Pressão Parcial , Suínos , VasoconstriçãoRESUMO
BACKGROUND: When O2-delivery to tissues is critically reduced, O2-consumption becomes dependent on O2-delivery and starts to decline, which reflects tissue hypoxia. In order to timely detect tissue hypoxia prior to organ damage, O2-consumption may be calculated or measured from respiratory gases. We have assessed reproducibility of calculated and measured O2-consumption-data and their agreement during O2-supply-dependency. METHOD: Data of 31 anesthetized, ventilated pigs were analysed retrospectively. Animals had undergone either controlled hemorrhage ("shock") or isovolemic exchange of blood with colloids (extreme hemodilution, "HD") until O2-consumption had become dependent on O2-delivery. O2-consumption was calculated from the Fick equation and measured simultaneously with a DELTATRAC II metabolic monitor. Repeatability was determined for (1) calculated and (2) for measured.VO2 -values and (3) for input variables of the Fick equation (i.e. cardiac index (CI) and arteriovenous O2-content difference (CaO2-CvO2)). Bias between calculated and measured data and precision of calculation were assessed from paired O2-consumption-values obtained before and after induction of O2-supply-dependency via hemorrhage or extreme hemodilution. RESULTS: Repeatability of the reversed Fick method was inferior to repeatability of measurement (27 vs 15%) due to error propagation from CI and (CaO2-CvO2). Between-method-bias at baseline ("BL") was 3%, and changed in case of O2-supply-dependency (shock -15%; HD -31%, both p<0.05 vs BL), precision of the reversed Fick method deteriorated (BL 32%; shock 60%; HD 60%) due to variability of CI (CV: 16%; shock 27%; HD 41%). CONCLUSION: In anesthetized pigs calculated and measured O2-consumption values are in agreement, while in presence of O2-supply-dependency the reversed Fick method (1) grossly underestimates true O2-consumption and (2) precision deteriorates not allowing to verify or reject the presence of tissue hypoxia.
Assuntos
Consumo de Oxigênio , Animais , Viés , Calorimetria Indireta , Débito Cardíaco , Hemodiluição , Hipóxia/diagnóstico , Hipóxia/metabolismo , Reprodutibilidade dos Testes , Choque Hemorrágico/metabolismo , SuínosRESUMO
BACKGROUND: Gastric tonometry is intended to reveal alterations in splanchnic perfusion and oxygenation. Based on the tonometric measurement of gastric mucosal partial pressure of carbon dioxide (pCO(2)) and the simultaneous determination of arterial blood gas parameters (bicarbonate concentration [HCO(3-)], pH and pCO(2)), several parameters can be calculated. AIMS: To identify the most suitable tonometric parameter [gastric mucosal pH (pH(i)), intramucosal pCO(2) (p(i)CO(2)), the difference between tonometric and arterial pCO(2) concentrations (pCO(2) gap), [H+] gap] that reliably reflects gastric hypoperfusion and hypoxia during severe haemorrhagic shock. DESIGN: Randomised, controlled experimental study. METHODS: An artificial stenosis of the left anterior descending coronary artery (LAD) was induced. Subsequently, the animals were haemorrhaged to a mean arterial pressure of 45 mmHg, which was maintained for 60 min. MEASUREMENTS AND MAIN RESULTS: Tonometric measurements were performed in 17 land-race pigs before and after induction of LAD stenosis and after haemorrhagic shock. P values obtained using the Wilcoxon signed-rank testing were used to compare the level of significance for the tonometric parameters and the corresponding arterial blood gas values [arterial pCO2 (p(a)CO(2)), [HCO(3-)], arterial pH (pH(a))]. While induction of critical coronary stenosis did not provoke any changes, all parameters changed significantly during haemorrhagic shock. The lowest P value was found for pH(i) (P=0.00013) followed by [H+ gap] (P=0.0005). P values higher by a factor of ten were found for pCO(2) gap (P=0.00119) and were highest for p(i)CO(2) (P=0.00562). P values of the corresponding arterial blood gas parameters were lower by a factor of ten than the P value of p(i)CO(2). CONCLUSION: pH(i), pCO(2) gap and [H+] gap are considerably influenced by changes of systemic arterial blood gas values. This is demonstrated by lower P values of the corresponding arterial blood gas values in comparison with p(i)CO(2). Therefore pH(i), pCO(2) gap and [H+] gap seem to indicate more likely systemic changes, whereas p(i)CO(2) appears to reflect disturbances of regional gastric tissue perfusion and oxygenation more reliably than any other derived tonometric parameter.
Assuntos
Dióxido de Carbono/análise , Mucosa Gástrica/irrigação sanguínea , Isquemia/diagnóstico , Manometria/métodos , Choque Hemorrágico/fisiopatologia , Circulação Esplâncnica/fisiologia , Animais , Dióxido de Carbono/sangue , Dióxido de Carbono/metabolismo , Isquemia/etiologia , Pressão Parcial , Estatísticas não Paramétricas , SuínosRESUMO
BACKGROUND: Normovolemic hemodilution is an effective strategy to limit perioperative homologous blood transfusions. The reduction of hematocrit related to hemodilution results in reduced arterial oxygen content, which initially is compensated for by an increase in cardiac output and oxygen extraction ratio. To increase the efficacy of hemodilution, a low hematocrit should be aimed for; however, this implies the risk of myocardial ischemia and tissue hypoxia. OBJECTIVE: To assess whether hemodilution can be extended to lower hematocrit values by the use of a hemoglobin-based artificial oxygen carrier solution. DESIGN: Prospective, randomized, controlled. SETTING: Animal laboratory of a university hospital. SUBJECTS: Twelve anesthetized, mechanically ventilated pigs. INTERVENTIONS: Isovolemic hemodilution was performed with either 10% diaspirin crosslinked hemoglobin (DCLHb Baxter Healthcare, Boulder, CO; n = 6) or 8% human albumin solution (HSA, oncotically matched to DCLHb, Baxter Healthcare; n = 6) to a hematocrit of 15%, 8%, 4%, 2%, and 1%. MEASUREMENTS AND MAIN RESULTS: In both groups, measurements were performed at baseline at the previously mentioned preset hematocrit values and at the onset of myocardial ischemia characterized by critical hematocrit (significant ST-segment depression >0.1 mV and/or arrhythmia). To determine peripheral tissue oxygenation and myocardial perfusion and function, the following variables were evaluated: total body oxygen transport variables, tissue oxygen partial pressure (tPo2, MDO-Electrode, Eschweiler Kiel, Germany) on the surface of the skeletal muscle, coronary perfusion pressure, left ventricular (LV) end-diastolic pressure, global and regional myocardial contractility (maximal change in pressure over time, LV segmental shortening, microsonometry method), LV myocardial blood flow (fluorescent microsphere technique), LV oxygen delivery, and the ratio between LV subendocardial and subepicardial myocardial perfusion. In the HSA group, critical hematocrit was found at 6.1 (1.8)% (hemoglobin, 2 g x dL(-1)), whereas all DCLHb-treated animals survived hemodilution until hematocrit 1.2 (0.2)% (hemoglobin, 4.7 g x dL(-1)) was achieved without signs of hemodynamic instability. Although arterial oxygen content was higher in the DCLHb group at 1.2% hematocrit than in the HSA group at critical hematocrit (i.e., hematocrit, 6.1%; hemoglobin, 2 g.dL-1) neither oxygen delivery and oxygen uptake nor median tPo2 and hypoxic tPo2 values on the skeletal muscle were different between groups. In contrast, subendocardial ischemia was absent in DCLHb-diluted animals until 1.2% hematocrit was achieved. This was attributable to a higher coronary perfusion pressure (65 (22) mm Hg vs. 19 (8) mm Hg; p <.05), higher subendocardial perfusion (4.1 (2.6) mL.min-1.g-1 vs. 1.2 (0.4) mL x min(-1) x g(-1)), and subendocardial oxygen delivery (5.7 (2) mL x min(-1) x g(-1), p <.05) in DCLHb-diluted animals, resulting in superior myocardial contractility reflected by maximal change in pressure over time (3829 (1914) vs. 1678 (730); p <.05) and higher regional myocardial contractility (11 (8)% vs. 6 (2)%; p <.05). An increased LV end-diastolic pressure reflected LV myocardial pump failure in HSA-diluted animals but was unchanged in DCLHb-diluted animals. In the DCLHb group, systemic vascular resistance index remained at baseline values throughout the protocol, whereas coronary vascular resistance decreased. In contrast, both variables decreased in HSA-diluted animals. CONCLUSION: DCLHb as a diluent allowed for hemodilution beyond the hematocrit value, determined "critical" after hemodilution with HSA (6.1% (1.8)%). Even at 1.2% hematocrit (hemoglobin, 4.7 g x dL(-1)) myocardial perfusion and function were maintained, although at the expense of peripheral tissue oxygenation. This discrepancy in regional oxygenation might be caused by a redistribution of blood flow favoring the heart, which is related to a disproportionate decrease of coronary vascular resistance index during hemodilution with DCLHb.
Assuntos
Aspirina/farmacologia , Hematócrito , Hemodiluição , Hemoglobinas/farmacologia , Consumo de Oxigênio , Animais , Aspirina/análogos & derivados , Volume Sanguíneo , Circulação Coronária/efeitos dos fármacos , Hemodinâmica/efeitos dos fármacos , Humanos , Contração Miocárdica/efeitos dos fármacos , Albumina Sérica/farmacologia , SuínosRESUMO
BACKGROUND: In subjects who have undergone acute preoperative normovolemic hemodilution (ANH), intraoperative hemorrhage is generally treated by immediate return of autologous blood collected during ANH. Simply increasing blood oxygen content by hyperoxic ventilation (HV, inspiratory fraction [FIO2] 1.0) might compensate for the acute anemia, allow further ANH, and delay onset of autologous blood return. STUDY DESIGN AND METHODS: This study 1) evaluated the effects of HV (FIO2 1.0) upon ANH to a hemoglobin (Hb) concentration of 7 g per dL in anesthetized dogs ventilated with room air and 2) compared the effects of subsequent profound ANH (Hb, 3 g/dL) with and without an intravenous perfluorocarbon emulsion (perflubron 60% wt/vol) versus those of autologous red cell transfusion. The results of the entire study are presented in two parts. Organ tissue oxygenation was assessed in skeletal muscle and liver, and systemic oxygenation status was evaluated. Myocardial contractility was deduced from left ventricular pressure-volume relationship. Seven of 22 dogs underwent further hemodilution while breathing 100-percent O2, for a determination of the Hb concentration at which HV-induced effects were abolished. RESULTS: HV completely reversed the ANH-induced increase in cardiac index (4.6 +/- 0.7 vs. 3.8 +/- 0.9 L/min/m2 before and during HV; p < 0.05) and partially reversed the decrease in systemic vascular resistance (1784 +/- 329 vs. 2087 +/- 524 dyn x cm-5 x sec x m-2; p < 0.05). Despite unchanged global O2 delivery, organ tissue oxygenation improved during HV (mixed venous partial pressure of O2: 40 +/- 3 vs. 59 +/- 7 torr; coronary venous pressure of O2: 30 +/- 4 vs. 43 +/- 6 torr; p < 0.05; liver surface: 31 +/- 11 vs. 39 +/- 13 torr; skeletal muscle surface: 30 +/- 14 vs. 41 +/- 22 torr; p < 0.05). This improvement was due to an increased contribution of physically dissolved O2 in plasma to O2 delivery (3.2 +/- 0.2% before HV vs. 14.6 +/- 1% during HV; p < 0.05) and O2 consumption (whole body: 6 +/- 1% vs. 47 +/- 8%, p < 0.05; myocardium: 4.3 +/- 0.9% vs. 31 +/- 6%, p < 0.05). The beneficial effects of HV were lost after an additional volume-compensated exchange of 19 percent of blood volume (Hb, 5.6 g/dL). CONCLUSION: In anesthetized dogs ventilated with room air and hemodiluted to a Hb of 7 g per dL, simple oxygen therapy by HV (FIO2 1.0) rapidly improves tissue oxygenation and permits extended hemodilution to Hb of 5.8 g per dL until the HV-induced effects are lost.
Assuntos
Perda Sanguínea Cirúrgica/prevenção & controle , Transfusão de Sangue , Hemodiluição , Respiração Artificial/efeitos adversos , Anestesia , Animais , Cães , Hemodinâmica , Transplante AutólogoRESUMO
BACKGROUND: Intravenously administered perfluorocarbon (PFC) emulsions increase oxygen solubility in plasma. PFC might therefore temporarily replace red cells (RBCs) lost during intraoperative hemorrhage. In patients who have undergone hemodilution, the return of autologous blood may be delayed by the administration of PFC, and autologous RBCs may be saved for transfusion after surgical bleeding is stopped and PFC is cleared by the reticuloendothelial system. STUDY DESIGN AND METHODS: In 22 anesthetized, hemodiluted dogs (hemoglobin [Hb] 7 g/dL) breathing 100-percent O2, an intraoperative volume-compensated blood loss was simulated. The efficacy of three therapeutic regimens in maintaining tissue oxygenation was compared: 1) RBC group (n = 7): maintenance of a Hb > 7 g per dL by transfusion of autologous RBCs; 2) PFC group (n = 7): bolus application of a second-generation PFC emulsion (60% wt/vol perflubron) and further acute normovolemic hemodilution (ANH) to a Hb of 3 g per dL; and 3) control group (n = 7): further ANH alone to a Hb of 3 g per dL. Systemic and myocardial oxygenation status and tissue oxygenation were assessed. RESULTS: Autologous RBCs transfused to maintain a Hb of 7 g per dL preserved hemodynamics and tissue oxygenation during blood loss. In the PFC and control groups, heart rate and cardiac index increased significantly in response to further ANH. Tissue oxygenation was not different in the PFC and the RBC groups. Direct comparison of the PFC and control groups revealed better tissue oxygenation in the PFC group, as reflected by significantly higher mixed venous, coronary venous, and local tissue pO2 on liver and skeletal muscle. CONCLUSION: Bolus intravenous administration of 60-percent (wt/vol) perflubron emulsion and further hemodilution from a Hb of 7 g per dL to one of 3 g per dL were as effective as autologous RBC transfusion in maintaining tissue oxygenation during volume-compensated blood loss designed to mimic surgical bleeding.
Assuntos
Transfusão de Sangue , Fluorocarbonos/administração & dosagem , Hemodiluição , Oxigênio/metabolismo , Animais , Cães , Hemodinâmica , Hidrocarbonetos Bromados , Injeções Intravenosas , Consumo de Oxigênio , RespiraçãoRESUMO
OBJECTIVE: Inhalation of high concentrations of nitric oxide (NO) has been shown to improve gas exchange and to reduce pulmonary vascular resistance in individuals with ischemia-reperfusion injury following orthotopic lung transplantation. We assessed the cardiopulmonary effects of low doses of NO in early allograft dysfunction following lung transplantation. DESIGN: Prospective clinical dose-response study. SETTING: Anesthesiological intensive care unit of a university hospital. PATIENTS AND PARTICIPANTS: 8 patients following a single or double lung transplantation who had a mean pulmonary arterial pressure (PAP) in excess of 4.7 kPa (35 mmHg) or an arterial oxygen tension/fractional inspired oxygen ratio (PaO2/FIO2) of less than 13.3 kPa (100 mmHg). INTERVENTIONS: Gaseous NO was inhaled in increasing concentrations (1, 4 and 8 parts per million, each for 15 min) via a Siemens Servo 300 ventilator. MEASUREMENTS AND RESULTS: Cardiorespiratory parameters were assessed at baseline, after each concentration of NO, and 15 min after withdrawal of the agent [statistics: median (25th/75th percentiles: Q1/Q3), rANOVA, Dunnett's test, p < 0.05]. Inhaled NO resulted in a significant, reversible, dose-dependent, selective reduction in PAP from 5.5(5.2/6.0) kPa at control to 5.1(4.7/5.6) kPa at 1 ppm, 4.9(4.3/5.3) kPa at 4 ppm, and to 4.7(4.1/5.1) kPa at 8 ppm. PaO2 increased from 12.7(10.4/17.1) to 19.2(12.4/26.0) kPa at 1 ppm NO, to 23.9(4.67/26.7) kPa at 4 ppm NO and to 24.5(11.9/28.7) kPa at 8 ppm NO. All patients responded to NO inhalation (either with PAP or PaO2), all were subject to long-term inhalation (1-19 days). All were successfully weaned from NO and were discharged from the intensive care unit. CONCLUSION: The present study demonstrates that low-dose inhaled NO may be an effective drug for symptomatic treatment of hypoxemia and/or pulmonary hypertension due to allograft dysfunction subsequent to lung transplantation.
Assuntos
Hipertensão Pulmonar/tratamento farmacológico , Hipertensão Pulmonar/etiologia , Transplante de Pulmão/efeitos adversos , Pulmão/irrigação sanguínea , Óxido Nítrico/uso terapêutico , Traumatismo por Reperfusão/tratamento farmacológico , Traumatismo por Reperfusão/etiologia , Vasodilatadores/uso terapêutico , Administração por Inalação , Adolescente , Adulto , Análise de Variância , Relação Dose-Resposta a Droga , Feminino , Humanos , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Óxido Nítrico/farmacologia , Estudos Prospectivos , Troca Gasosa Pulmonar/efeitos dos fármacos , Pressão Propulsora Pulmonar/efeitos dos fármacos , Traumatismo por Reperfusão/fisiopatologia , Vasodilatadores/farmacologiaRESUMO
The influence of severe acute normovolemic hemodilution (ANH) on myocardial contractility (MC) was investigated in 14 splenectomized, anesthetized dogs. MC was assessed by the maximum rate of left ventricular pressure increase (LVdp/dt(max)), end-systolic elastance (Ees), and preload recruitable stroke work (PRSW) (conductance catheter, left ventricular pressure-volume relationship). Measurements of myocardial perfusion and oxygenation (radioactive microsphere technique) assured comparability of the model to previously performed studies. Global and regional myocardial blood flow increased significantly upon hemodilution with preference to midmyocardium and subendocardium. This resulted in preservation of both myocardial oxygen delivery and consumption after ANH. Myocardial oxygen extraction as well as coronary venous Po2 were unaffected by ANH, while coronary venous lactate concentration decreased, indicating that myocardial oxygen need was met. LVdp/dt(max) decreased significantly after hemodilution (2278 +/- 577 vs 1884 +/- 381 mm Hg/s, P < 0.01), whereas Ees and PRSW increased significantly (1.76 +/- 0.54 vs 2.15 +/- 0.75 mm Hg/mL, P < 0.05, for Ees and 33 +/- 14 vs 45 +/- 14 mm Hg.mL, P < 0.05, for PRSW). While the decrease of LVdp/dt(max) most likely reflects ANH-induced changes of ventricular pre- and afterload, the increase of Ees and PRSW indicates a true increase of myocardial contractility during ANH in anesthetized dogs.
Assuntos
Anestesia , Hemodiluição , Contração Miocárdica , Animais , Circulação Coronária , Cães , Hemodinâmica , Lactatos/metabolismo , Ácido Láctico , Miocárdio/metabolismo , Oxigênio/sangue , Consumo de Oxigênio , Volume Sistólico , Função VentricularRESUMO
Administration of drugs via the airway is increasingly practiced in ICU- and surgical patients. For this purpose, aerosols may be produced by either jet nebulization or ultrasonic droplet generation. In mechanically ventilated patients, aerosol delivery is often insufficient. The influence of the ventilatory pattern on nebulizer efficacy is poorly understood. In the present in vitro study we determined the efficacy of a new ultrasonic nebulizer in delivering aerosolized epoprostenol using defined ventilator settings. We determined aerosol delivery rates, the aerosol droplet size distribution and the impact of the connection tubing on drug delivery, applying adult and infant ventilation patterns. Aerosol production rates ranged from 0.28 to 0.57 ml per minute. Using an adult ventilator setting volume controlled ventilation (CMV) led to a higher aerosol production rate than pressure controlled ventilation (PCV) at identical tidal volumes and mean airway pressures (0.57 ml/min,CMV vs 0.39 ml/min, PCV). With an infant ventilator setting, nebulizer rates were lower than those found for the adult ventilator setting, but did not differ substantially between CMV and PCV mode (0.29 ml/min, CMV vs 0.28 ml/min, PCV). Aerosol delivery rates distal to the endotracheal tube changed according to aerosol production rates (adult mode: 0.18 ml/min, CMV vs 0.10 ml/min, PCV; infant mode: 0.03 ml/min, both CMV and PCV). In the infant ventilation mode, a higher percentage of the aerosol was trapped in the catheter mount as compared to the adult ventilation mode. Mass median droplet diameters for each of the four ventilator settings were almost identical (4.63 to 5.09 micron) and smaller than indicated in the product specifications (8 micron). Delivery rates and sizes of droplets delivered by the new ultrasonic nebulizer SUN 345(R) agree well with previously reported data from comparable settings using diverse nebulizer devices.