1.
Pharmaceutics ; 15(5)2023 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-37242653

RESUMO

Loop diuretics and antibiotics are commonly co-prescribed across many clinical care settings. Loop diuretics may alter antibiotic pharmacokinetics (PK) via several potential drug interactions. A systematic review of the literature was performed to investigate the impact of loop diuretics on antibiotic PK. The primary outcome metric was the ratio of means (ROM) of antibiotic PK parameters such as area under the curve (AUC) and volume of distribution (Vd) on and off loop diuretics. Twelve crossover studies were amenable for metanalysis. Coadministration of diuretics was associated with a mean 17% increase in plasma antibiotic AUC (ROM 1.17, 95% CI 1.09-1.25, I2 = 0%) and a mean decrease in antibiotic Vd by 11% (ROM 0.89, 95% CI 0.81-0.97, I2 = 0%). However, the half-life was not significantly different (ROM 1.06, 95% CI 0.99-1.13, I2 = 26%). The remaining 13 observational and population PK studies were heterogeneous in design and population, as well as prone to bias. No large trends were collectively observed in these studies. There is currently not enough evidence to support antibiotic dosing changes based on the presence or absence of loop diuretics alone. Further studies designed and powered to detect the effect of loop diuretics on antibiotic PK are warranted in applicable patient populations.

2.
J Cardiovasc Electrophysiol ; 34(3): 738-747, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36640427

RESUMO

INTRODUCTION: Cardiac Implantable Electronic Devices (CIEDs) are widely used for the management of advanced heart failure and ventricular arrhythmias. CIED-Infection (CIED-I) has very high mortality, especially in the subsets of patients with limited health-care access and delayed presentation. The purpose of this study is to identify the risk-predictors mortality in subjects with CIED-I. METHODS: We performed a retrospective cohort study of a regional database in patients presenting with CIED infections to tertiary care medical centers across Western New York, USA from 2012 to 2020. The clinical outcomes included recurrent device infection (any admission for CIED-I after the first hospitalization for device infection), septic complications (pulmonary embolism, respiratory failure, septic shock, decompensated HF, acute kidney injury) and mortality outcomes (death during hospitalization, within 30 days from CIED-I, and within 1 year from CIED-I). We studied associations between categorical variables and hard outcomes using χ2 tests and used one-way analysis of variance to measure between-groups differences. RESULTS: We identified 296 patients with CIED-I, among which 218 (74%) were male, 237 (80%) were white and the mean age at the time of infection was 69.2 ± 13.7 years. One-third of the patients were referred from the regional facilities. Staphylococcus aureus was responsible for most infections, followed by Enterococcus fecalis. On multivariate analysis, the covariates associated with significantly increased mortality risk included referral from regional facility (OR: 2.0;1.0-4.0), hypertension (Odds ratio, OR: 3.2;1.3-8.8), right ventricular dysfunction (OR: 2.6;1.2-5.1), end-stage renal disease (OR: 2.6;1.1-6.2), immunosuppression (OR: 11.4;2.5-53.3), and septic shock as a complication of CIED-I (OR: 3.9;1.3-10.8). CONCLUSION: Hypertension, right ventricular dysfunction, immunosuppression, and end-stage renal disease are associated with higher mortality after CIED-I. Disproportionately higher mortality was also noted in subjects referred from the regional facilities. This underscores the importance of early clinical risk-assessment, and the need for a robust referral infrastructure to improve patient outcomes.


Assuntos
Desfibriladores Implantáveis , Cardiopatias , Falência Renal Crônica , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Choque Séptico , Disfunção Ventricular Direita , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Marca-Passo Artificial/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Choque Séptico/complicações , Cardiopatias/etiologia , Fatores de Risco , Falência Renal Crônica/complicações , Infecções Relacionadas à Prótese/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA