Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Can J Cardiol ; 35(2): 160-168, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30760422

RESUMO

BACKGROUND: Physicians treating nonvalvular atrial fibrillation (AF) assess stroke and bleeding risks when deciding on anticoagulation. The agreement between empirical and physician-estimated risks is unclear. Furthermore, the association between patient and physician sex and anticoagulation decision-making is uncertain. METHODS: We pooled data from 2 national primary care physician chart audit databases of patients with AF (Facilitating Review and Education to Optimize Stroke Prevention in Atrial Fibrillation and Coordinated National Network to Engage Physicians in the Care and Treatment of Patients with Atrial Fibrillation Chart Audit) with a combined 1035 physicians (133 female, 902 male) and 10,927 patients (4567 female and 6360 male). RESULTS: Male physicians underestimated stroke risk in female patients and overestimated risk in male patients. Female physicians estimated stroke risk well in female patients but underestimated the risk in male patients. Risk of bleeding was underestimated in all. Despite differences in risk assessment by physician and patient sex, > 90% of patients received anticoagulation across all subgroups. There was modest agreement between physician estimated and calculated (ie, CHADS2 score) stroke risk: Kappa scores were 0.41 (0.35-0.47) for female physicians and 0.34 (0.32-0.36) for male physicians. CONCLUSIONS: Our study is the first to examine the association between patient and physician sex influences and stroke and bleeding risk estimation in AF. Although there were differences in agreement between physician estimated stroke risk and calculated CHADS2 scores, these differences were small and unlikely to affect clinical practice; further, despite any perceived differences in the accuracy of risk assessment by sex, most patients received anticoagulation.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Hemorragia/etiologia , Medição de Risco/métodos , Acidente Vascular Cerebral/etiologia , Idoso , Fibrilação Atrial/tratamento farmacológico , Canadá/epidemiologia , Feminino , Hemorragia/epidemiologia , Humanos , Incidência , Masculino , Fatores de Risco , Fatores Sexuais , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle
2.
Am J Cardiol ; 120(4): 582-587, 2017 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-28666577

RESUMO

Using data collected from 2 national atrial fibrillation (AF) primary care physician chart audits (Facilitating Review and Education to Optimize Stroke Prevention in Atrial Fibrillation [FREEDOM AF] and Co-ordinated National Network to Engage Physicians in the Care and Treatment of Patients With Atrial Fibrillation [CONNECT AF]), we evaluated the frequency of, and factors associated with, the use of cardiovascular (CV) evidence-based therapies in Canadian AF outpatients with at least 1 CV risk factor or co-morbidity. Of the 11,264 patients enrolled, 9,495 (84.3%) were eligible for one or more CV evidence-based therapies. The proportions of patients with AF receiving all eligible guideline-recommended therapies were 40.8% of patients with coronary artery disease, 48.9% of patients with diabetes mellitus, 40.2% of patients with heart failure, 96.7% of patients with hypertension, and 55.1% of patients with peripheral arterial disease. Factors that were independently associated with nonreceipt of all indicated evidence-based therapies included sinus rhythm rather than AF at baseline and liver disease. In conclusion, although most Canadian outpatients with AF have CV risk factors or co-morbidities, a substantial portion of these patients did not receive all guideline-recommended therapies. These findings suggest that there is an opportunity to improve the quality of care for patients with AF in Canada.


Assuntos
Fibrilação Atrial/terapia , Medicina Baseada em Evidências/normas , Pacientes Ambulatoriais , Médicos de Atenção Primária/educação , Guias de Prática Clínica como Assunto , Medição de Risco , Acidente Vascular Cerebral/prevenção & controle , Idoso , Fibrilação Atrial/complicações , Canadá/epidemiologia , Competência Clínica , Feminino , Humanos , Incidência , Masculino , Médicos de Atenção Primária/normas , Avaliação de Programas e Projetos de Saúde , Sistema de Registros , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia
3.
J Med Genet ; 54(6): 390-398, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28264985

RESUMO

BACKGROUND: Variable expressivity and incomplete penetrance between individuals with identical long QT syndrome (LQTS) causative mutations largely remain unexplained. Founder populations provide a unique opportunity to explore modifying genetic effects. We examined the role of a novel synonymous KCNQ1 p.L353L variant on the splicing of exon 8 and on heart rate corrected QT interval (QTc) in a population known to have a pathogenic LQTS type 1 (LQTS1) causative mutation, p.V205M, in KCNQ1-encoded Kv7.1. METHODS: 419 adults were genotyped for p.V205M, p.L353L and a previously described QTc modifier (KCNH2-p.K897T). Adjusted linear regression determined the effect of each variant on QTc, alone and in combination. In addition, peripheral blood RNA was extracted from three controls and three p.L353L-positive individuals. The mutant transcript levels were assessed via qPCR and normalised to overall KCNQ1 transcript levels to assess the effect on splicing. RESULTS: For women and men, respectively, p.L353L alone conferred a 10.0 (p=0.064) ms and 14.0 (p=0.014) ms increase in QTc and in men only a significant interaction effect in combination with the p.V205M (34.6 ms, p=0.003) resulting in a QTc of ∼500 ms. The mechanism of p.L353L's effect was attributed to approximately threefold increase in exon 8 exclusion resulting in ∼25% mutant transcripts of the total KCNQ1 transcript levels. CONCLUSIONS: Our results provide the first evidence that synonymous variants outside the canonical splice sites in KCNQ1 can alter splicing and clinically impact phenotype. Through this mechanism, we identified that p.L353L can precipitate QT prolongation by itself and produce a clinically relevant interactive effect in conjunction with other LQTS variants.


Assuntos
Canal de Potássio KCNQ1/genética , Splicing de RNA/genética , Síndrome de Romano-Ward/genética , Arritmias Cardíacas/genética , Éxons/genética , Feminino , Genótipo , Humanos , Masculino , Mutação/genética , Fenótipo
4.
Heart Rhythm ; 14(6): 801-807, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28232263

RESUMO

BACKGROUND: Progression from paroxysmal to persistent atrial fibrillation (AF) has important clinical implications and is relevant to the management of patients with AF. OBJECTIVE: The purpose of this study was to define the long-term rate of progression from paroxysmal to persistent AF and the relevant clinical variables. METHODS: The Canadian Registry of Atrial Fibrillation enrolled patients after a first electrocardiographic diagnosis of paroxysmal AF. Associations between baseline characteristics and clinical outcomes were evaluated using a multivariable Cox proportional hazard model and a competing risk model accounting for death as a competing risk, where appropriate. RESULTS: We enrolled 755 patients (61.7% men) aged between 14 and 91 years (mean age 61.2 ± 14.2 years). The median follow-up was 6.35 years (interquartile range 2.93-10.04 years), with a rate of progression to persistent AF at 1, 5, and 10 years was 8.6%, 24.3%, and 36.3%, respectively. All-cause mortality was 30.3% at 10 years. Factors associated with AF progression were increasing age (hazard ratio [HR] 1.40; 95% confidence interval [CI] 1.23-1.60, for each 10-year increment), mitral regurgitation (HR 1.87; 95% CI 1.28-2.73), left atrial dilatation (HR 3.01; 95% CI 2.03-4.47), aortic stenosis (HR 2.40; 95% CI 1.05-5.48), and left ventricular hypertrophy (HR .47; 95% CI 1.04-2.08). Factors associated with a lower rate of progression were a faster heart rate during AF (HR 0.94; 95% CI 0.92-0.96 per 5-beat/min increment) and angina (HR 0.54; 95% CI 0.38-0.77). After accounting for death as a competing risk, left ventricular hypertrophy and aortic stenosis were no longer significant. CONCLUSION: Within 10 years of presenting with paroxysmal AF, >50% of patients will progress to persistent AF or be dead. Increasing age, mitral regurgitation, aortic stenosis, left ventricular hypertrophy, and left atrial dilatation were associated with progression to persistent AF.


Assuntos
Fibrilação Atrial/diagnóstico , Eletrocardiografia/métodos , Previsões , Sistema de Registros , Medição de Risco/métodos , Taquicardia Paroxística/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Canadá/epidemiologia , Causas de Morte/tendências , Progressão da Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Taquicardia Paroxística/epidemiologia , Taquicardia Paroxística/fisiopatologia , Adulto Jovem
5.
J Interv Card Electrophysiol ; 47(2): 163-170, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27394160

RESUMO

BACKGROUND: The protective effect of beta-blockers in patients with inherited Long-QT syndrome is well established. Recent reports have suggested that beta-blockers are not equally effective in Long-QT (LQT). Bisoprolol is an attractive candidate for use in LQT because of its cardioselective properties and favorable side-effect profile. METHODS: We performed a retrospective cohort study of 114 consecutive patients with gene-positive Long-QT syndrome type 1 (LQT1) or Long-QT syndrome type 2 (LQT2) treated with bisoprolol, nadolol or atenolol with a total of 580 person-years of follow-up. Electrocardiogram (ECG) parameters and cardiac events during follow-up were compared. In addition, exercise treadmill testing was performed in bisoprolol-treated patients. RESULTS: Fifty-nine patients were treated with bisoprolol, 39 with atenolol and 16 with nadolol. Overall, 59 % were females and 62 % had LQT1. Baseline heart rate and corrected QT (QTc) interval were similar between the groups. QTc shortening was observed in individuals on bisoprolol (ΔQTc -5 ± 31 ms; p = 0.049) and nadolol (ΔQTc -13 ± 16 ms; p = 0.02) but not on atenolol (ΔQTc +9 ± 24 ms; p = 0.16). Median follow-up was similar for bisoprolol and nadolol (3 years), but longer for atenolol (6 years; p = 0.03); one cardiac event occurred in the bisoprolol group (1.7 %) and two events occurred in the atenolol group (5.1 %; p = 0.45), whereas none occurred in nadolol-treated patients. Beta-blocker efficacy was not affected by the underlying genotype. The antiadrenergic effect of bisoprolol correlated with the reduction of peak heart rates at exercise testing. CONCLUSIONS: Bisoprolol treatment results in QTc shortening in gene-positive LQT1 and LQT2 patients and is well tolerated during long-term administration. The equivalence of bisoprolol for protection from ventricular arrhythmia in LQT patients compared to established beta-blockers remains unknown. Further large-scale studies are required.


Assuntos
Bisoprolol/administração & dosagem , Eletrocardiografia/efeitos dos fármacos , Síndrome do QT Longo/tratamento farmacológico , Síndrome de Romano-Ward/diagnóstico , Síndrome de Romano-Ward/tratamento farmacológico , Antagonistas de Receptores Adrenérgicos beta 1 , Adulto , Canadá , Cardiotônicos/administração & dosagem , Estudos de Coortes , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Síndrome do QT Longo/diagnóstico , Masculino , Estudos Retrospectivos , Resultado do Tratamento
6.
Can J Cardiol ; 32(3): 336-43, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26476851

RESUMO

BACKGROUND: Canadian atrial fibrillation (AF) guidelines recommend that all AF patients be risk stratified with respect to stroke and bleeding, and that most should receive antithrombotic therapy. METHODS: As part of the Canadian Facilitating Review and Education to Optimize Stroke Prevention in Atrial Fibrillation (FREEDOM AF) chart audit, data were collected on 4670 patients ≥ 18 years old without significant valvular heart disease from the primary care practices of 474 physicians (February to September, 2011). RESULTS: Physicians did not provide an estimate of stroke and bleeding risk in 15% and 25% of patients, respectively. When risks were provided, they were on the basis of a predictive stroke and bleeding risk index in only 50% and 26% of patients, respectively. There were over- and underestimation of stroke and bleeding risk in a large proportion of patients. Antithrombotic therapy included warfarin (90%); 24% of patients had a time in the therapeutic range (TTR) < 50%, 9% between 50% and 60%, 11% between 60% and 70%, and 56% had a TTR ≥ 70%. CONCLUSIONS: In a large Canadian AF population, primary care physicians did not provide a stroke or bleeding risk in a substantial proportion of their AF patients. When estimates were provided, they were on the basis of a predictive stroke and bleeding risk index in less than half of the patients. Furthermore, there was under- and overestimation of stroke and bleeding risk in a substantial proportion of patients. As many as 1 in 3 patients receiving warfarin have their TTR < 60%. These findings suggest an opportunity to enhance knowledge translation to primary care physicians.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Educação de Pacientes como Assunto , Medição de Risco , Acidente Vascular Cerebral/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Canadá/epidemiologia , Feminino , Humanos , Incidência , Masculino , Prognóstico , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Taxa de Sobrevida/tendências
7.
J Cardiovasc Electrophysiol ; 26(12): 1340-5, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26471861

RESUMO

INTRODUCTION: Medtronic's Lead Integrity Alert (LIA) software algorithm is useful for detecting abnormal parameters across various ICD-lead families. However, its utility in the assessment of the Biotronik Linox™ family of high-voltage (HV) leads is unknown. METHODS: We conducted a retrospective cohort study to assess the performance of the LIA algorithm to detect abnormalities and lead failure in Linox ICD-leads. All LIA-enabled Medtronic devices connected to an active Linox lead were included. The alerts were adjudicated by 2 blinded electrophysiologists and correlated with clinical data. RESULTS: Between 2008 and 2012, data from 208 patients with 564 patient-years of follow-up were available for analysis. The median follow-up duration was 32 (IQR 21-41 months). Twenty-one LIA triggers were noted in 20 different patients. The median delay until a positive LIA was 32 months (IQR 21-41 months) postimplant with a 5-year lead survival free from LIA of 76%. Ninety-five percent (19/20) LIA alerts were true lead failures. The most common LIA triggers were short V-V intervals (85%) and nonsustained ventricular tachycardia (85%). Abrupt changes of the ICD-lead impedance occurred in 5/20 triggers. Inappropriate ICD-shocks were strongly associated with a positive LIA (30% vs. 7.4%; P = 0.006). Of the explanted Linox leads 53% had visible abnormalities. The sensitivity, specificity, and positive predictive value for lead failure in the presence of a LIA trigger were 87%, 99.5%, and 95.2%, respectively. CONCLUSIONS: A positive LIA trigger in Biotronik Linox ICD-leads is highly predictive of lead failure. LIA is useful in ongoing surveillance of lead performance.


Assuntos
Algoritmos , Desfibriladores Implantáveis , Taquicardia Ventricular/terapia , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Estudos de Coortes , Morte Súbita Cardíaca/prevenção & controle , Intervalo Livre de Doença , Eletrocardiografia , Falha de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Ventricular/fisiopatologia , Falha de Tratamento
8.
Circ Cardiovasc Qual Outcomes ; 8(2 Suppl 1): S21-30, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25714829

RESUMO

BACKGROUND: Social health is a dimension of quality of life, and refers to people's involvement in, and satisfaction with social roles, responsibilities, and activities. The implantable cardioverter-defibrillator is associated with changes in overall quality of life, but little is known about sex differences in individual trajectories of change in social health. METHODS AND RESULTS: We prospectively measured changes in 3 subscales of the SF-36v2 generic health questionnaire (role physical, role emotional, and social functioning), 2 Patient-Reported Outcomes Measurement Information System short forms (satisfaction with participation in social roles and satisfaction with participation in discretionary social activities), and the Florida Patient Acceptance Survey before and at 1, 2, and 6 months after implantation. Individual growth models of temporal change were estimated. The scores of the 6 indicators improved with time. The unconditional model demonstrated significant (fixed effects: P<0.05; covariance parameters: P<0.10) residual variability in the individual trajectories. In the conditional model, men and women differed significantly in their rates of change in the scores of 3 of the 6 measures. Although men's mean scores exceeded women's mean scores on all indicators at baseline (range of relative mean difference: 11.0% to 17.8%), the rate of women's change resulted in a reversal in relative standing at 6 months after implantation, with the mean scores of women exceeding the men's by 4.5% to 5.6%. CONCLUSIONS: Men and women differed in their trajectories of change in social health, both in terms of their starting points (ie, baseline scores) and their rates of change.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Qualidade de Vida , Comportamento Social , Adulto , Idoso , Cardioversão Elétrica/efeitos adversos , Emoções , Feminino , Disparidades nos Níveis de Saúde , Humanos , Relações Interpessoais , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Prospectivos , Fatores Sexuais , Responsabilidade Social , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
9.
Future Cardiol ; 10(3): 319-22, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24976467

RESUMO

Barrett PM, Komatireddy R, Haaser S et al. Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring. Am. J. Med. 127(1), 95.e11­95.e17 (2014). The investigation of cardiac arrhythmias in the outpatient ambulatory setting has traditionally been initiated with the Holter monitor. Using the continuous recording over 24 or 48 h, the Holter monitor permits the detection of baseline rhythm, dysrhythmia and conduction abnormalities, including heart block and changes in the ST segment that may indicate myocardial ischemia. However, apart from the bulkiness and inconvenience of the device itself, the lack of extended monitoring results in a diagnostic yield of typically less than 20%. In this study by Barrett et al., 146 patients referred for the evaluation of cardiac arrhythmia were prospectively enrolled to wear both the 24-h Holter monitor and 14-day adhesive patch monitor (Zio Patch) simultaneously. The primary outcome was the detection of any one of six arrhythmias: supraventricular tachycardia, atrial fibrillation/flutter, pause >3 s, atrioventricular block, ventricular tachycardia, or polymorphic ventricular tachycardia/fibrillation. The adhesive patch monitor detected more arrhythmia events compared with the Holter monitor over the total wear time (96 vs. 61 events; p < 0.001), although the Holter monitor detected more events during the initial 24-h monitoring period (61 vs. 52 events; p = 0.013). Novel, single-lead, intermediate-duration, user-friendly adhesive patch monitoring devices, such as the Zio Patch, represent the changing face of ambulatory ECG monitoring. However, the loss of quality, automated rhythm analysis and inability to detect myocardial ischemia continue to remain important issues that will need to be addressed prior to the implementation of these new devices.


Assuntos
Arritmias Cardíacas/diagnóstico , Eletrocardiografia Ambulatorial , Eletrocardiografia/métodos , Feminino , Humanos , Masculino
10.
Circulation ; 129(20): 2021-30, 2014 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-24610807

RESUMO

BACKGROUND: This study reports the impact of cardiac resynchronization therapy (CRT) on hospitalizations in patients randomized to implantable cardioverter-defibrillator (ICD) or ICD-CRT in the Resynchronization-Defibrillation for Ambulatory Heart Failure Trial (RAFT). METHODS AND RESULTS: Hospitalization rates and lengths of hospital stay were compared between the 2 groups. At the 18-month follow-up, the numbers of patients hospitalized for any cause were similar in the ICD (n=351, 38.8%) and ICD-CRT (n=331, 30.0%) groups. The number of patients hospitalized for heart failure was significantly lower in the ICD-CRT (n=101, 11.3%) compared with the ICD (n=141, 15.6%; P=0.003) group. The number of patients hospitalized for a device-related indication was similar in the ICD-CRT group (n=147, 16.4%) and ICD group (n=126, 13.9%; P=0.148). The total number of hospitalizations for any cause (n=1448 versus n=1553; P=0.042), any cardiovascular cause (n=667 versus n=790; P=0.017), and any heart failure cause (n=385 versus n=505; P<0.0001) was significantly lower in ICD-CRT group compared with the ICD group, whereas the number of hospitalizations for device-related causes was significantly higher in the ICD-CRT group compared with the ICD group (246 versus 159; P<0.001). Although the reduction in hospitalizations for heart failure in the CRT-ICD group was offset by an increased number of hospitalizations for device-related indications, the length of hospital stay for any cause was significantly shorter in the ICD-CRT group (8.83±13.30 days) compared with the ICD group (9.59±14.40 days; P=0.005). CONCLUSION: ICD-CRT therapy significantly reduces hospitalizations and total days in hospital in patients with New York Heart Association class II/III heart failure compared with ICD therapy despite increased admissions for device-related indications. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00251251.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Hospitalização/estatística & dados numéricos , Tempo de Internação/estatística & dados numéricos , Readmissão do Paciente/estatística & dados numéricos , Idoso , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Fatores de Risco , Prevenção Secundária
11.
Heart ; 99(17): 1250-5, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23468515

RESUMO

BACKGROUND: There is a relative paucity of data linking inappropriate implantable cardioverter-defibrillator (ICD) shocks to adverse clinical outcomes. OBJECTIVE: To examine the association between inappropriate ICD shocks and mortality or heart transplantation in a large population cohort. DESIGN, SETTING, PATIENTS: A cohort study which included all subjects who underwent ICD implantation between 1998 and 2008 and were followed up at our institution. MAIN OUTCOME MEASURES: Multivariable Cox regression analyses were conducted to investigate the effect of inappropriate shocks on the risk of death and heart transplantation. Appropriate and inappropriate ICD therapies were modelled as time-dependent covariates. RESULTS: A total of 1698 patients were included. During a median follow-up of 30 months, there were 246 (14.5%) deaths and 42 (2.5%) heart transplants. The incidence of inappropriate shocks was 10% at 1 year and 14% at 2 years. In the adjusted model, inappropriate shocks were not associated with death or transplantation (HR=0.97, 95% CI 0.70 to 1.36, p value=0.873). In contrast, appropriate shocks were associated with adverse outcomes (HR=3.11, 95% CI 2.41 to 4.02, p value<0.001). The lack of association between inappropriate shocks and outcomes persisted for those with severely impaired left ventricular function (ejection fraction <30%) and for those receiving multiple inappropriate treatments. CONCLUSIONS: In this study, we observed no association between inappropriate ICD shocks and increased mortality or heart transplantation, even among those with severely impaired cardiac function. These findings question whether inappropriate ICD shocks lead to adverse outcomes.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Transplante de Coração/estatística & dados numéricos , Idoso , Arritmias Cardíacas/mortalidade , Colúmbia Britânica , Estudos de Coortes , Morte Súbita Cardíaca/epidemiologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Prognóstico , Modelos de Riscos Proporcionais , Fatores de Risco , Volume Sistólico/fisiologia
14.
Europace ; 12(11): 1571-3, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20798118

RESUMO

AIMS: In the era of increasing implantable cardioverter defibrillator (ICD) complexity, the ICD patient alert is deemed to be an important feature in the early detection of ICD system malfunction and is either an audible or a vibratory alert. We sought to evaluate the patient's ability to detect these ICD alerts in the device clinic setting as a surrogate endpoint of clinical utility. METHODS AND RESULTS: From 1 November 2006 to 31 March 2008, 563 patients with an ICD equipped with either an audible patient alert (APA, Medtronic and Guidant; n = 485) or a vibratory monitoring alert ([VMA, St Jude Medical; n = 78) had their alarm demonstrated in the quiet clinic setting. The ability to recognize the alert was analysed and then stratified by gender, age, manufacturer, type of alert, and pocket location. The average patient age was 63.3 (± 13.6) years and 82.8% of patients were male. Implantable cardioverter defibrillator manufacturers were Medtronic (n = 464), Boston Scientific (n = 21), and SJM (n = 78). The APA was heard in 86.0% of patients. This was less likely in patients who were older, male, and where the device was placed in the submuscular position. Every patient with a VMA sensed their alert. CONCLUSION: In the current ICD alert technology, the ability to sense the ICD alert in the device clinic appears to be higher for the VMA than for the APA. In particular, older patients and male patients are less likely to sense the APA.


Assuntos
Desfibriladores Implantáveis , Falha de Prótese , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensação
15.
Heart Rhythm ; 7(9): 1171-7, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20430112

RESUMO

BACKGROUND: The pharmacologic management of atrial fibrillation (AF), the most common sustained cardiac arrhythmia, has been traditionally dichotomized into control of ventricular rate or re-establishment and maintenance of sinus rhythm. OBJECTIVE: The purpose of this study was to evaluate the use of rate-controlling drugs and antiarrhythmic drugs (AAD) in the Canadian Registry of Atrial Fibrillation (CARAF) over a 16-year period from 1991 through 2007. METHODS: 1,400 patients with new-onset paroxysmal AF who were enrolled in CARAF were included in this analysis. We assessed trends in ventricular rate-controlling medication use (digoxin, beta-blockers, and calcium channel blockers) and AAD (class IA, IC, and III antiarrhythmic agents) at baseline and follow-up visits as well as by calendar year. RESULTS: AAD use increased initially from 1991 to 1994 (peak use 42.5%) before steadily declining. Sotalol use decreased (27% to 6%), whereas amiodarone use increased (1.6% to 17.9%). Rate-controlling medication use decreased from 1991 to 1995 (54.1% to 34.1%) due to declining digoxin use (62.9% to 16.3%). After 1999, there was a continued increase in rate-controlling medication use (peak use 52.5% in 2007) due to increased beta-blocker use (17% to 45.7%). Calcium channel blockers use changed little over the duration of the study. CONCLUSION: The management of AF has undergone significant shifts since 1990, reflecting the influence of drug development, prevailing belief systems, the impact of large clinical trials, and evidence-based recommendations. Monitoring of pharmacotherapy trends will provide insight into the real-world application of evidence-based guidelines as well as allow the opportunity to identify deficiencies and improve patient care.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Frequência Cardíaca/efeitos dos fármacos , Sistema de Registros , Antagonistas Adrenérgicos beta/uso terapêutico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Bloqueadores dos Canais de Cálcio/uso terapêutico , Canadá/epidemiologia , Eletrocardiografia/efeitos dos fármacos , Seguimentos , Humanos , Pessoa de Meia-Idade , Morbidade/tendências , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
18.
J Cardiovasc Electrophysiol ; 21(2): 177-82, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19804544

RESUMO

BACKGROUND: There is uncertainty about the proper role of defibrillation testing (DT) at the time of implantable cardioverter defibrillator (ICD) insertion. METHODS: A prospective registry was conducted at 13 sites in Canada between January 2006 and October 2007. OBJECTIVES: To document the details of DT, the reasons for not conducting DT, and the costs and complications associated with DT. RESULTS: DT was conducted at implantation in 230 of 361 patients (64%). DT was more likely to be conducted for new implants compared with impulse generator replacements (71% vs 32%, P = 0.0001), but was similar for primary and secondary prevention indications (64% vs 63%, P = NS). Among patients not having DT, the reason(s) given were: considered unnecessary (44%); considered unsafe, mainly due to persistent atrial fibrillation (37%); lack of an anesthetist (20%); and, patient or physician preference (6%). When performed, DT consisted of a single successful shock > or = 10J below maximum device output in 65% of cases. A 10J safety-margin was met by 97% of patients, requiring system modification in 2.3%. Major perioperative complications occurred in 4.4% of patients having DT versus 6.6% of patients not having DT (P = NS). ICD insertion was $844 more expensive for patients having DT (P = 0.16), largely due to increased costs ($28,017 vs $24,545) among patients having impulse generator replacement (P = 0.02). CONCLUSIONS: DT was not performed in a third of ICD implants, usually due to a perceived lack of need or relative contraindication.


Assuntos
Desfibriladores Implantáveis/economia , Análise de Falha de Equipamento/economia , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/prevenção & controle , Cuidados Intraoperatórios/estatística & dados numéricos , Padrões de Prática Médica/economia , Sistema de Registros/estatística & dados numéricos , Idoso , Canadá/epidemiologia , Desfibriladores Implantáveis/estatística & dados numéricos , Análise de Falha de Equipamento/estatística & dados numéricos , Custos de Cuidados de Saúde/estatística & dados numéricos , Insuficiência Cardíaca/epidemiologia , Humanos , Pessoa de Meia-Idade , Padrões de Prática Médica/estatística & dados numéricos , Prevalência , Medição de Risco , Fatores de Risco
19.
Circ Arrhythm Electrophysiol ; 2(3): 218-24, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19808471

RESUMO

BACKGROUND: Atrial fibrillation (AF) is commonly associated with impaired quality of life. There is no simple validated scale to quantify the functional illness burden of AF. The Canadian Cardiovascular Society Severity in Atrial Fibrillation (CCS-SAF) scale is a bedside scale that ranges from class 0 to 4, from no effect on functional quality of life to a severe effect on life quality. This study was performed to validate the scale. METHODS AND RESULTS: In 484 patients with documented AF (62.2+/-12.5 years of age, 67% men; 62% paroxysmal and 38% persistent/permanent), the SAF class was assessed and 2 validated quality-of-life questionnaires were administered: the SF-36 generic scale and the disease-specific AFSS (University of Toronto Atrial Fibrillation Severity Scale). There is a significant linear graded correlation between the SAF class and measures of symptom severity, physical and emotional components of quality of life, general well-being, and health care consumption related to AF. Patients with SAF class 0 had age- and sex-standardized SF-36 scores of 0.15+/-0.16 and -0.04+/-0.31 (SD units), that is, units away from the mean population score for the mental and physical summary scores, respectively. For each unit increase in SAF class, there is a 0.36 and 0.40 SD unit decrease in the SF-36 score for the physical and mental components. As the SAF class increases from 0 to 4, the symptom severity score (range, 0 to 35) increases from 4.2+/-5.0 to 18.4+/-7.8 (P<0.0001). CONCLUSIONS: The CCS-SAF scale is a simple semiquantitative scale that closely approximates patient-reported subjective measures of quality of life in AF and may be practical for clinical use.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/psicologia , Nível de Saúde , Índice de Gravidade de Doença , Inquéritos e Questionários/normas , Fatores Etários , Idoso , Fibrilação Atrial/terapia , Canadá , Serviços Médicos de Emergência/estatística & dados numéricos , Feminino , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Qualidade de Vida , Reprodutibilidade dos Testes , Fatores Sexuais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA