Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
2.
Adv Ther ; 41(1): 231-245, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37884810

RESUMO

INTRODUCTION: This study investigated patient satisfaction levels in five premium intraocular lenses (IOLs). A secondary aim was to determine whether patient satisfaction was associated with the cataract grade before lens surgery. METHODS: In this multicenter prospective comparative study, 164 patients from diverse backgrounds underwent cataract surgery and were assigned for identical bilateral implantation of multifocal IOLs. In addition to visual performance, quality of life was measured using the National Eye Institute Refractive Error Quality Of Life Instrument (NEI-RQL 42) scoring questionnaire. The Sirius Scheimpflug Analyzer was used to evaluate the posterior cornea and aberrations. Finally, the association of patient satisfaction reports with the Pentacam Cataract Grading Scale (PCGS) and Lens Opacities Classification System (LOCS III) was evaluated. RESULTS: A considerable subjective improvement was observed in uncorrected far, near (40 cm), and intermediate (60 cm) visual acuity in the five groups (P values < 0.001). A significant difference was observed in mesopic and photopic contrast sensitivity between Symfony, Trinova, and AT LISA at the spatial frequency of 12 cycles per degree, favoring Symfony (P < 0.001). PanOptix users had considerably lower mean coma values (P < 0.001), while AT LISA users had lower mean spherical aberrations (P = 0.009) compared to the other groups. No additional safety concerns relating to IOLs were recorded. Mean satisfaction had a high correlation with LOCS and Pentacam Nuclear Staging (PNS) in each lens group, e.g., correlation coefficient and P value for AT LISA were respectively r = 0.99, P < 0.001 and r = 0.97, P = 0.004. CONCLUSION: Despite discrepancies between groups of lenses, most patients who received multifocal IOLs reported satisfaction at more than 3 years after the initial operation. A growing number of patients with cataracts are seeking spectacle-free vision with presbyopia-correcting IOLs. Hence, the high satisfaction rate among patients with cataract could indicate the value of offering a wider range of available lenses.


Assuntos
Catarata , Lentes Intraoculares , Lentes Intraoculares Multifocais , Humanos , Catarata/complicações , Implante de Lente Intraocular , Satisfação do Paciente , Estudos Prospectivos , Desenho de Prótese , Qualidade de Vida
3.
J Ophthalmol ; 2022: 4024603, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35957744

RESUMO

Purpose: To compare superficial retinal vascular, choriocapillaris (CC), and choroidal thickness changes in chronic central serous chorioretinopathy (CSCR) patients after half-dose photodynamic therapy (PDT). Method: In this prospective interventional case series study, fifteen eyes of 14 patients with chronic CSCR undergoing half-dose PDT treatment were enrolled. All patients underwent enhanced depth imaging optical coherence tomography angiography (EDI-OCT) and optical coherence tomography angiography (OCTA) at baseline and 3 months after treatment. Best-corrected visual acuity (BCVA), superficial retinal vascular density, CC vessel density, foveal avascular zone (FAZ), central macular thickness (CMT), and choroidal thickness were compared. Results: Mean BCVA before and after PDT was 0.34 ± 0.26 and 0.19 ± 0.25 logMAR, respectively (p=0.011). Mean FAZ before treatment was 410.21 ± 117.00 µm2, which increased to 433.50 ± 116.76 µm2 (P=0.253). Mean vessel density at superficial capillary plexus (SCP) was 38.93 ± 11.12 at baseline, which increased to 39.04 ± 11.43 (P=0.886). Mean CC vessel density was 53.21 ± 4.14 at baseline, which significantly decreased to 51.85 ± 4.21 (P=<0.001). BCVA has no significant correlation with FAZ (P=0.282) and vessel density (P=0.0.241) at SCP. CMT significantly decreased from 380.87 ± 41.66 µ at baseline to 268.20 ± 28.07 µ at 3 months (P=0.132). We did not find any correlation between CMT and FAZ (P=0.040) and vessel density (P=0.686) at SCP. Mean subfoveal choroidal thickness reduced from 411 ± 171 µm before treatment to 372 ± 117 µm (P=0.106). Conclusion: PDT treatment can affect retinal and choroidal structural parameters, but we could not find any significant influence on retinal vascular parameters, including FAZ area and vessel densityonly mean CC vessel density and subfoveal choroidal thickness decreased.

4.
J Ophthalmic Vis Res ; 12(4): 380-384, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29090046

RESUMO

PURPOSE: To describe the preparation and thickness profiles of endothelial keratoplasty lenticules harvested from eyes with previous photorefractive keratectomy (PRK). METHODS: Donor whole eyes that underwent PRK were subjected to microkeratome-assisted dissection for Descemet stripping automated endothelial keratoplasty. Specular microscopy and Visante optical coherence tomography were performed on precut corneas. Endothelial cell indices and thickness profiles of endothelial keratoplasty lenticules were statistically analyzed. Postoperative reports for transplanted lenticules were recorded. RESULTS: Over a 6-month period, 2,929 whole eyes from 1,471 donors were screened for PRK. Twenty-five (0.85%) eyes from 14 donors were diagnosed with disciform haziness due to prior PRK and were used uneventfully for preparation of endothelial keratoplasty lenticules. Mean endothelial cell count was 3164.6 ± 311.0/mm2 and mean central posterior lenticule thickness was 128 ± 34 µm. Posterior lenticules revealed an increase in thickness from the central to peripheral cornea (mean increase of 26.2 µm at pericentral and 90.4 µm at peripheral locations). Mean increase in thickness was statistically different between two peripheral locations (74.5 µm vs. 108.1 µm, P = 0.047). Postoperative reports of transplanted lenticules revealed no posterior flap detachment or loss of clarity at least three months after the surgery. CONCLUSION: PRK donor whole eyes are potential sources for preparation of microkeratome-assisted thin endothelial keratoplasty lenticules with a high endothelial cell count. Although an asymmetric and significant increase in thickness was present at the peripheral cornea, neither attachment nor clarity of transplanted lenticules was affected by variations in thickness of precut corneas.

5.
Cell Tissue Bank ; 18(1): 99-104, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27838813

RESUMO

This study was conducted to analyze the profile and thickness of endothelial keratoplasty lenticules prepared from fresh donated whole eyes with Visante optical coherence tomography (V-OCT) compared to measurements obtained from ultrasound pachymetry (USP) at the Central Eye Bank of Iran. Microkeratome-assisted precut corneas were prepared for Descemet stripping automated endothelial keratoplasty by using standard eye bank protocol. Central posterior lenticule thickness (CPLT) on fresh whole eye, before excising corneoscleral disc and transferring to Optisol-GS, was measured by USP. V-OCT was used to measure central, paracentral, and midperipheral thicknesses of lenticules after transferring the tissue to Optisol-GS. Chi Square and Bonferroni tests were respectively used to uncover the differences between the USP and V-OCT measurements and also the thickness profile of lenticules. Postoperative reports for the entire transplanted lenticules were recorded. Accordingly, on evaluation of 312 enrolled precut corneas, CPLT measurements by V-OCT versus USP were statistically different (mean: 136 µm vs 165 µm, respectively; P = 0.008). Thickness profile of the posterior lenticules revealed increased thickness from the central to the peripheral parts of the cornea (mean increase of 16 µm at the pericentral and 64.2 µm at the peripheral locations, respectively); however, the increase in the thickness was relatively symmetrical. Postoperative reports of transplanted lenticules were unremarkable, since there were no posterior flap detachments. In essence, V-OCT measurements of microkeratome-assisted precut lenticules prepared from fresh donated whole eyes averaged 29 µm thinner than USP measurements and revealed a significant but symmetric increase of thickness towards the peripheral parts of the corneas. However, the variation in the thickness profile did not affect the attachment or the clarity of transplanted precut lenticlues.


Assuntos
Córnea/diagnóstico por imagem , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/métodos , Adolescente , Adulto , Idoso , Endotélio Corneano/diagnóstico por imagem , Bancos de Olhos , Humanos , Pessoa de Meia-Idade , Doadores de Tecidos , Tomografia de Coerência Óptica , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA