Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
1.
EuroIntervention ; 20(12): e770-e780, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38887883

RESUMO

BACKGROUND: Coronary access (CA) is a major concern in redo-transcatheter aortic valve implantation (TAVI) for failing supra-annular self-expanding transcatheter aortic valves (TAVs). AIMS: This ex vivo study evaluated the benefit of leaflet splitting (LS) on subsequent CA after redo-TAVI in anatomies deemed at high risk of unfeasible CA. METHODS: Ex vivo, patient-specific models were printed three-dimensionally. Index TAVI was performed using ACURATE neo2 or Evolut PRO (TAV-1) at the standard implant depth and with different degrees of commissural misalignment (CMA). Redo-TAVI was performed using the balloon-expandable SAPIEN 3 Ultra (TAV-2) at different implant depths with commissural alignment. Selective CA was attempted for each configuration before and after LS in a pulsatile flow simulator. The leaflet splay area was assessed on the bench. RESULTS: In matched comparisons of 128 coronary cannulations across 64 redo-TAVI configurations, the overall feasibility of CA significantly increased after LS (60.9% vs 18.7%; p<0.001). The effect of LS varied according to the sinotubular junction height, TAV-1 design, TAV-1 CMA, and TAV-2 implant depth, given TAV-2 alignment. LS enabled CA for up to CMA 45° with the ACURATE neo2 TAV-1 and up to CMA 30° with the Evolut PRO TAV-1. The combination of LS and a low TAV-2 implant provided the highest feasibility of CA after redo-TAVI. The leaflet splay area ranged from 25.60 mm2 to 37.86 mm2 depending on the TAV-1 platform and TAV-2 implant depth. CONCLUSIONS: In high-risk anatomies, LS significantly improves CA feasibility after redo-TAVI for degenerated supra-annular self-expanding platforms. Decisions on redo-TAVI feasibility should be carefully individualised, taking into account the expected benefit of LS on CA for each scenario.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/instrumentação , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Impressão Tridimensional , Estenose da Valva Aórtica/cirurgia , Vasos Coronários/cirurgia , Falha de Prótese , Reoperação
4.
J Am Coll Cardiol ; 84(1): 13-24, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38759906

RESUMO

BACKGROUND: Placebo-controlled evidence from ORBITA-2 (Objective Randomised Blinded Investigation with Optimal Medical Therapy of Angioplasty in Stable Angina-2) found that percutaneous coronary intervention (PCI) in stable coronary artery disease with little or no antianginal medication relieved angina, but residual symptoms persisted in many patients. The reason for this was unclear. OBJECTIVES: This ORBITA-2 secondary analysis investigates the relationship between presenting symptoms and disease severity (anatomic, noninvasive, and invasive ischemia) and the ability of symptoms to predict the placebo-controlled efficacy of PCI. METHODS: Prerandomization symptom severity and nature were assessed using the ORBITA smartphone application and symptom and quality of life questionnaires including the World Health Organization Rose angina questionnaire (Rose). Disease severity was assessed using quantitative coronary angiography, stress echocardiography, fractional flow reserve, and instantaneous wave-free ratio. Bayesian ordinal regression was used. RESULTS: At prerandomization, the median number of daily angina episodes was 0.8 (Q1-Q3: 0.4-1.6), 64% had Rose angina, quantitative coronary angiography diameter stenosis was 61% (Q1-Q3: 49%-74%), stress echocardiography score was 1.0 (Q1-Q3: 0.0-2.7), fractional flow reserve was 0.63 (Q1-Q3: 0.49-0.75), and instantaneous wave-free ratio was 0.78 (Q1-Q3: 0.55-0.87). There was little relationship between symptom severity and nature and disease severity: angina symptom score with quantitative coronary angiography ordinal correlation coefficient: 0.06 (95% credible interval [CrI]: 0.00-0.08); stress echocardiography: 0.09 (95% CrI: 0.02-0.10); fractional flow reserve: 0.04 (95% CrI: -0.03 to 0.07); and instantaneous wave-free ratio: 0.04 (95% CrI: -0.01 to 0.07). However, Rose angina and guideline-based typical angina were strong predictors of placebo-controlled PCI efficacy (angina symptom score: OR: 1.9; 95% CrI: 1.6-2.1; probability of interaction [PrInteraction] = 99.9%; and OR: 1.8; 95% CrI: 1.6-2.1; PrInteraction = 99.9%, respectively). CONCLUSIONS: Although symptom severity and nature were poorly associated with disease severity, the nature of symptoms powerfully predicted the placebo-controlled efficacy of PCI.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Masculino , Feminino , Intervenção Coronária Percutânea/métodos , Pessoa de Meia-Idade , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico , Idoso , Resultado do Tratamento , Angiografia Coronária , Índice de Gravidade de Doença , Angina Estável/terapia , Angina Estável/diagnóstico , Angina Estável/fisiopatologia , Qualidade de Vida
5.
EuroIntervention ; 20(6): e376-e388, 2024 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-38506739

RESUMO

BACKGROUND: There are limited data regarding treatment for failed balloon-expandable transcatheter heart valves (THVs) in redo-transcatheter aortic valve implantation (TAVI). AIMS: We aimed to assess THV performance, neoskirt height and expansion when performing redo-TAVI with the ACURATE platform inside a SAPIEN 3 (S3) compared to redo-TAVI with an S3 in an S3. METHODS: Redo-TAVI was performed on the bench using each available size of the S3, the ACURATE neo2 (ACn2) and the next-generation ACURATE Prime XL (AC XL) implanted at 2 different depths within 20 mm/23 mm/26 mm/29 mm S3s serving as the "failed" index THV. Hydrodynamic testing was performed to assess THV function. Multimodality assessment was performed using photography, X-ray, microcomputed tomography (micro-CT), and high-speed videos. RESULTS: The ACURATE in S3 combinations had favourable hydrodynamic performance compared to the S3 in S3 for all size combinations. In the 20 mm S3, redo-TAVI with the ACn2 had lower gradients compared to the S3 (mean gradient 16.3 mmHg for the ACn2 vs 24.7 mmHg for the 20 mm S3 in 20 mm S3). Pinwheeling was less marked for the ACURATE THVs than for the S3s. On micro-CT, the S3s used for redo-TAVI were underexpanded across all sizes. This was also observed for the ACURATE platform, but to a lesser extent. CONCLUSIONS: Redo-TAVI with an ACn2/AC XL within an S3 has favourable hydrodynamic performance and less pinwheeling compared to an S3 in S3. This comes at the price of a taller neoskirt.


Assuntos
Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Microtomografia por Raio-X , Catéteres , Valvas Cardíacas
6.
J Clin Med ; 13(2)2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38276098

RESUMO

Transcatheter aortic valve implantation (TAVI) is now well established as the treatment of choice for patients with native aortic valve stenosis who are high or intermediate risk for surgical aortic valve replacement. Recent data has also supported the use of TAVI in patients at low surgical risk and also in anatomical subsets that were previously felt to be contra-indicated including bicuspid aortic valves and aortic regurgitation. With advancements and refinements in procedural techniques, the application of this technology has now been further expanded to include the management of degenerated bioprosthesis. After the demonstration of feasibility and safety in the management of degenerated aortic bioprosthetic valves, mitral and tricuspid bioprosthetic valve treatment is now also well-established and provides an attractive alternative to performing redo surgery. In this review, we appraise the latest clinical evidence and highlight procedural considerations when utilising TAVI technology in the management of degenerated aortic, mitral or tricuspid prosthesis.

7.
J Cardiovasc Dev Dis ; 11(1)2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38276659

RESUMO

BACKGROUND: Current European guidelines support transcatheter aortic valve implantation (TAVI) in intermediate-to-low-risk patients ≥75 years-old, but its prognostic relevance is unknown. METHODS: Intermediate-to-low-risk (The Society of Thoracic Surgeons score <8%) patients enrolled in the HORSE registry were included. We compared the populations aged under 75 with those over 75. The primary endpoint was all-cause mortality. RESULTS: A total of 2685 patients were included: 280 (8.6%) < 75 and 2405 ≥ 75 years. Through a mean follow-up of 437 ± 381 days, 198 (8.2%) and 23 (8.2%) patients died in the two arms without statistically significant differences (log-rank p = 0.925). At Cox regression analysis, age did not predict the occurrence of all-cause death, neither as a continuous variable (HR 1.01, 95% CI 0.99-1.04, p = 0.294) nor dichotomizing according to the prespecified cutoff of 75 years (HR 0.97, 95% CI 0.63-1.51, p = 0.924). Time-to-event ROC curves showed low accuracy of age to predict all-cause mortality (area under the curve of 0.54 for both 1-year and 2-year outcomes). CONCLUSIONS: TAVI has comparable benefits across age strata for intermediate-to-low-risk patients. The age cutoff suggested by the current guidelines is not predictive of the risk of adverse events during hospital stays or of all-cause mortality through a mid-term follow-up.

8.
Catheter Cardiovasc Interv ; 102(7): 1401-1405, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37694603

RESUMO

Valve-in-valve TAVI to treat failing surgical aortic valves (SAVs) is increasingly performed, and commissural alignment is a key technical aspect in such procedures. Surgeons optimize valve alignment, accounting for potential coronary eccentricity and achieving a patient-specific optimized commissural orientation, representing the ideal target for TAVI alignment. Therefore, here we present a dedicated stepwise valve-in-valve implantation technique using the ACURATE neo2. In a specific SAV postoverlap view, isolating one surgical post to the right of the screen representing the target for alignment, rotational orientation of the TAVI commissures, matching the SAV orientation, is achieved and verified before implantation. This technique has been tested in a patient-specific three-dimensionally-printed aortic root anatomy, attached to a pulsatile flow simulator, allowing for native-like simulation of coronary cannulations under fluoroscopy, and enabling detailed assessment with fluoroscopic as well as direct videographic visualization. Furthermore, the technique is exemplified by providing an educational clinical case example.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Desenho de Prótese
11.
Eur Heart J ; 44(35): 3311-3322, 2023 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-37350487

RESUMO

Technological advancement and the COVID-19 pandemic have brought virtual learning and working into our daily lives. Extended realities (XR), an umbrella term for all the immersive technologies that merge virtual and physical experiences, will undoubtedly be an indispensable part of future clinical practice. The intuitive and three-dimensional nature of XR has great potential to benefit healthcare providers and empower patients and physicians. In the past decade, the implementation of XR into cardiovascular medicine has flourished such that it is now integrated into medical training, patient education, pre-procedural planning, intra-procedural visualization, and post-procedural care. This review article discussed how XR could provide innovative care and complement traditional practice, as well as addressing its limitations and considering its future perspectives.


Assuntos
COVID-19 , Realidade Virtual , Humanos , COVID-19/epidemiologia , Pandemias/prevenção & controle
13.
Catheter Cardiovasc Interv ; 101(4): 798-805, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36841945

RESUMO

OBJECTIVES: The objective of this study is to investigate the use of cutting balloon (CB) inflated at high pressure compared with noncompliant balloon (NCB) for the treatment of calcified coronary lesions. BACKGROUND: No data are available regarding the safety and efficacy of CB inflated at high pressure in coronary artery calcifications. METHODS: Patients with calcified lesions (more than 100° of calcium demonstrated at baseline intravascular ultrasound) were randomized. Primary endpoint of the study was the final minimal stent area (MSA) and stent symmetry in the calcific segment. Secondary endpoints included rate of device failure and the 1-year rate of target lesion revascularization, target vessel revascularization, and major adverse cardiovascular events. RESULTS: From September 2019 to June 2021, a total of 100 patients were included and randomized; 13 patients were excluded for major protocol deviations. Lesions were complex (type B2/C n = 61 [71.2%]) with a mean arch of calcium of 266 ± 84°, a calcium length of 12 ± 6.6 mm. CB was inflated at comparable atmospheres when compared with NCB (18.3 ± 5 vs. 19 ± 4.5, p = 0.46). In the per-protocol population, the final MSA at the level of the calcium site was significantly higher in the CB group (8.1 ± 2 vs. 7.3 ± 2.1, p = 0.035) with a higher eccentricity index achieved in the CB group (0.84 ± 0.07 vs. 0.8 ± 0.08, p = 0.013). Three device failure occurred in the CB group. One-year follow-up outcomes were comparable. CONCLUSIONS: Treatment of calcified lesions with high-pressure CB has a good safety profile and is associated with a larger MSA and higher eccentricity of the stent at the level of the calcium site compared with NCB.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Humanos , Angiografia Coronária , Cálcio , Resultado do Tratamento , Doença da Artéria Coronariana/terapia , Stents
16.
Minerva Cardiol Angiol ; 71(3): 303-310, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35767236

RESUMO

BACKGROUND: Interventional cardiologists' mental workload may impact on their performance as well as on patients' outcome. Nevertheless, little attention is paid to the monitoring and optimization of their mental status. Electroencephalogram (EEG)-based neural-interfaces can estimate mental fatigue and sleepiness through spectral analysis techniques and the amplitude of alpha waves is a widely validated indicator of mental engagement's level. METHODS: The present study aims to describe mental fatigue and sleepiness through variation of psychometrics and neurometrics during a work shift in a population of 7 interventional cardiologists. Neurometrics have been acquired at the beginning of the shift, before and after each procedure performed during 127 valid Alpha Attenuation Protocols (AAP), a practical test to quantify sleepiness measuring alpha power during 2 cycle of eye opening/closing protocol. We collected alpha waves' power measures obtained during resting condition (AA Coefficient-eyes open [AAC-eo], AAC-eyes closed [AAC-ec] and AAC-mean), related to fatigue, and AAC-ec/AAC-eo (AAC-ratio), related to sleepiness. RESULTS: From a two-months observation, the first interesting preliminary results emerged: 1) AAC-mean showed an upward trend during the working day, reflecting an increase in mental fatigue (P=0.01); 2) population-level psychometrics trend confirms the same tendency described by neurometrics, possibly reflecting a reduced awareness of the operator of his/her actual mental status. CONCLUSIONS: Developing a low cost and high feasibility device to monitor and analyze operator's mental engagement level could be extremely appealing, considering the lack of data in literature for interventional disciplines and recent technology developments.


Assuntos
Cardiologistas , Sonolência , Humanos , Masculino , Feminino , Atenção , Vigília , Fadiga Mental
17.
J Clin Med ; 13(1)2023 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-38202217

RESUMO

BACKGROUND: Stent implantation represents the standard of care in coronary intervention. While a short stent implanted on a focal lesion located on the left anterior descending artery (LAD) seems a reasonable alternative to an internal mammary implant, the same for long stents is still debated. METHODS: We reported the long-term data of 531 consecutive patients who underwent Percutaneous Coronary Intervention (PCI) with long stents in two highly specialized centres. The main inclusion criteria were the implantation of stents longer than 30 mm on the LAD and a minimum follow-up (FU) of five years. The primary endpoint was mortality, and the secondary endpoints were any myocardial infarction (MI), target vessel and lesion revascularization (TVR and TLR, respectively), and stent thrombosis (ST) observed as definite, probable, or possible. RESULTS: In this selected population with characteristics of complex PCI (99.1%), the long-term follow-up (mean 92.18 ± 35.5 months) estimates of all-cause death, cardiovascular death, and any myocardial infarction were 18.3%, 10.5%, and 9.3%, respectively. Both all-cause and cardiovascular deaths are significantly associated with three-vessel disease (HR 6.8; confidence of interval (CI) 95% 3.844-11.934; p < 0.001, and HR 4.7; CI 95% 2.265-9.835; p < 0.001, respectively). Target lesion (TLR) and target vessel revascularization (TVR) are associated with the presence of three-lesion disease on the LAD (HR 3.4; CI 95% 1.984-5.781; p < 0.001; HR 3.9 CI 95% 2.323-6.442; p < 0.001, respectively). Re-PCI for any cause occurred in 31.5% of patients and shows an increased risk for three-lesion stenting (HR 4.3; CI 95% 2.873-6.376; p < 0.001) and the treatment of bifurcation with two stents (HR 1.6; 95% CI 1.051-2.414; p = 0.028). Stent thrombosis rate at the 5-year FU was 4.4% (1.3% definite; 0.9% probable; 2.1% possible), including a 1.7% rate of very-late thrombosis. The stent length superior to 40 mm was not associated with poor outcomes (all-cause death p = 0.349; cardiovascular death p = 0.855; MI p = 0.691; re-PCI p = 0.234; TLR p = 0.805; TVR p = 0.087; ST p = 0.189). CONCLUSION: At an FU of longer than five years, patients treated with stents longer than 30 mm in their LAD showed acceptable procedural results but poor outcomes.

18.
JACC Case Rep ; 28: 102118, 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-38204544

RESUMO

We demonstrate a modified technique of heterotopic chimney stenting for coronary obstruction during valve-in-valve transcatheter aortic valve replacement With successful end-on cannulation via the stent ostium. Our technique was reproducible on the bench with successful reaccess and without any interaction between the deployed coronary stent and the prosthetic leaflets.

19.
Interv Cardiol ; 18: e30, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38213745

RESUMO

Since the first robotic-assisted percutaneous coronary intervention procedure (R-PCI) was performed in 2004, there has been a steady evolution in robotic technology, combined with a growth in the number of robotic installations worldwide and operator experience. This review summarises the latest developments in R-PCI with a focus on developments in robotic technology, procedural complexity, tele-stenting and training methods, which have all contributed to the global expansion in R-PCI.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA