Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 238
Filtrar
2.
Ophthalmologie ; 2024 May 03.
Artigo em Alemão | MEDLINE | ID: mdl-38700761
6.
Invest Ophthalmol Vis Sci ; 65(3): 36, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38551585

RESUMO

Purpose: Symptomatic vitreous opacifications, so-called floaters, are difficult to objectively assess majorly limiting the possibility of in vitro studies. Forward light scattering was found previously to be increased in eyes with symptomatic floaters. Using an objective setup to measure forward light scattering, we studied the effects of enzymatically digesting the components of the vitreous body on straylight to develop an in vitro model of vitreous opacifications. Methods: Fifty-seven porcine vitreous bodies were digested using hyaluronidase, collagenase, trypsin, and bromelain, as well as using a combination of hyaluronidase + collagenase and hyaluronidase + bromelain. A modified C-Quant setup was used to objectively assess forward light scattering. Results: Depletion of hyaluronic acid majorly increased vitreous straylight (mean increase 34.4 deg2/sr; P = 0.01), whereas primarily digesting the vitreous gel with collagenase or trypsin did not significantly affect straylight. When collagenase or bromelain is applied in hyaluronic acid depleted vitreous gels, the increase in forward light scattering is reversed partially. Conclusions: The age-related loss of hyaluronic acid primarily drives the increase in vitreous gel straylight induced by conglomerates of collagen. This process can be reversed partially by digesting collagen. This in vitro model allows the objective quantification and statistical comparison of straylight burden caused by vitreous opacities and, thus, can serve as a first testing ground for pharmacological therapies, as demonstrated with bromelain.


Assuntos
Bromelaínas , Luz , Animais , Suínos , Hialuronoglucosaminidase/farmacologia , Ácido Hialurônico/farmacologia , Tripsina , Envelhecimento , Colágeno/farmacologia , Colagenases/farmacologia , Espalhamento de Radiação
7.
Cornea ; 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38478752

RESUMO

PURPOSE: The purpose of this study was to determine whether the Scheimpflug tomographically normal fellow eyes of keratoconus patients are also classified as normal using an ectasia screening algorithm based on anterior segment optical coherence tomography (AS-OCT). METHODS: This monocentric cross-sectional study included 22 very asymmetric ectasia patients with tomographically significant keratoconus in 1 eye and normal Scheimpflug tomography in the fellow eye. Twenty-two eyes of 22 healthy subjects served as a control group. We performed corneal tomography using Pentacam AXL (Oculus, Wetzlar, Germany) and used Belin/Ambrósio Enhanced Ectasia total deviation index as well as Belin ABCD keratoconus classification to identify Scheimpflug tomographically normal eyes. We also performed AS-OCT using Anterion (Heidelberg Engineering, Heidelberg, Germany) and analyzed for the presence of ectasia using the Screening Corneal Objective Risk of Ectasia (SCORE) algorithm, with positive values indicating ectasia suspect tomography. RESULTS: The SCORE value was positive in 9.1% (n = 2) of the healthy eyes, in 45.5% (n = 10) of the Scheimpflug tomographically normal eyes of keratoconus patients and in all eyes (n = 22) with tomographically significant keratoconus. The Scheimpflug tomographically normal eyes of keratoconus patients had higher SCORE values compared with healthy controls (P < 0.001). The median (interquartile range) SCORE value was -1.7 (1.3) in healthy controls, -0.5 (2.2) in Scheimpflug tomographically normal eyes of keratoconus patients, and 11.1 (11.0) in tomographically significant keratoconus eyes. CONCLUSIONS: The Scheimpflug tomographically normal fellow eyes of keratoconus patients had higher AS-OCT-based SCORE values than healthy controls, with positive SCORE values found in 46% of the eyes, indicating early tomographic ectatic changes.

10.
Clin Ophthalmol ; 18: 525-536, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38405105

RESUMO

Purpose: To assess the safety and efficacy of a customized ablation treatment (InnovEyes) to correct myopia and myopic astigmatism with femtosecond laser-assisted in situ keratomileusis (Femto LASIK). Patients and Methods: In this prospective, nonrandomized, multicenter study, 113 patients (225 eyes) with preoperative myopia less than -9.0 diopters (D) and astigmatism 0 to -4.0 D (based on InnovEyes refraction) underwent wavefront, tomography, and biometry assessment using a single diagnostic device (InnovEyes sightmap). These data were imported and used unmodified by the InnovEyes algorithm to automatically calculate and optimize correction of lower- and higher­order aberrations (HOAs) treated by the EX500 ablation profile. Visual acuity, refractive error, HOAs, and patient satisfaction were evaluated over 3 months. Results: A total of 106 patients (212 eyes) completed the study and were included in the analysis. Mean preoperative manifest refraction spherical equivalent (MRSE) was -3.38±1.76 D. At Month 3, uncorrected distance visual acuity was 20/20 or better in 208/212 (98.1%) eyes, and it was the same as, or better than, the preoperative best-corrected distance visual acuity (CDVA) in 162/212 (76.4%) eyes; 76/212 (35.8%) eyes gained ≥1 line of CDVA. MRSE was within ±0.5 D in 195/212 (92.0%) eyes. Additionally, 201/209 (96.2%) eyes had no change (defined as a change between -0.1 µm and 0.1 µm, inclusive) in HOAs, and 105/106 (99.1%) patients reported to be satisfied with the results. Conclusion: Customizing ray-tracing Femto LASIK with this platform appeared safe and effective in correcting myopic astigmatism and also achieved a significant percentage of eyes gaining lines of vision, potentially by addressing HOAs, along with a consistently high level of patient satisfaction.

11.
J Refract Surg ; 40(2): e79-e88, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38346120

RESUMO

PURPOSE: To investigate the optical performance and tolerance to misalignment of blue-light filtering monofocal intraocular lenses (IOLs). METHODS: The optical properties of two monofocal IOLs featuring yellow chromophores, CT Lucia 621 PY (Carl Zeiss Meditec AG) and Clareon CNA0T0 (Alcon Laboratories, Inc), were assessed in monochromatic and polychromatic light while introducing spherical aberration (SA). Optical quality metrics derived from the modulation transfer function were assessed after optimal IOL centration at 3- and 4.5-mm pupils. In addition, each IOL's tolerance to misalignment was examined by inducing up to 1 mm of decentration and the effect of tilting it by 5 degrees at 3 mm. RESULTS: The IOLs' resolution and contrast, while tested using a 3-mm aperture and an SA-neutral corneal model, indicated the CT Lucia 621 PY had a slightly higher modulation transfer function (MTF) at 50 lp/mm than the CNA0T0 under monochromatic conditions (0.77 vs 0.69). On introducing SA with (0.49 vs 0.40) and without (0.75 vs. 0.70) chromatic aberration, the CT Lucia 621 PY maintained its minimally better performance. When assessed with a 4.5-mm aperture in monochromatic light, the CT Lucia 621 PY displayed improved MTF with aberration-free cornea (0.71 vs 0.40) but performed worse after introducing SA (0.44 vs 0.62). However, both lenses achieved comparable MTF values under spherical and chromatic aberrations (0.28 vs 0.27). The IOL misalignment test revealed a better tolerance to tilt and decentration of the CT Lucia 621 PY across all conditions. CONCLUSIONS: The CT Lucia 621 PY and CNA0T0 showed similar optical quality in different situations, with equal simulated distance visual acuity for both models. However, the CT Lucia 621 PY's aspheric design offers an advantage when dealing with often imperfect physiological conditions, displaying a more robust performance under tilt and decentration. [J Refract Surg. 2024;40(2):e79-e88.].


Assuntos
Lentes Intraoculares , Humanos , Visão Ocular , Acuidade Visual , Pupila , Luz Azul , Desenho de Prótese
12.
J Cataract Refract Surg ; 50(4): 413-419, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38237073

RESUMO

PURPOSE: To objectively quantify glare of intraocular lenses (IOLs) using a diffractive principle to extend the visual range and to identify models with increased susceptibility to inducing glare. SETTING: David J Apple Laboratory, Heidelberg, Germany. DESIGN: Laboratory investigation. METHODS: Glare was assessed by means of a straylight parameter with a standard C-Quant intended for 7 degrees. In addition, 2 C-Quant modifications were used to test lower angles (ie, 2.5 degrees and 3.5 degrees). The following IOL models were assessed: PanOptix, AT Lisa Tri, Synergy, and Triumf, the latter 2 with chromatic aberration correction at distance. Straylight from trifocal IOLs was compared against a monofocal W-60R lens. The C-Quant test was performed through the studied IOLs by using additional optical components attached to their ocular. RESULTS: Straylight (deg 2 sr -1 ) of the control was <1 at all tested angles, with the trifocal models showing comparable straylight at 7 degrees. At 3.5 degrees, Triumf's straylight increased to 15.5 ± 0.6, followed by Synergy (6.2 ± 1.1), PanOptix (4.1 ± 0.3), and AT Lisa Tri (2.0 ± 0.8). The chromatic aberration-correcting models demonstrated correspondingly higher straylight (Synergy: 18.8 ± 1.3; Triumf: 17.3 ± 0.5) at 2.5 degrees compared with PanOptix (4.3 ± 0.4), AT Lisa Tri (2.1 ± 0.1), and monofocal IOLs yielding minimal or no increase. CONCLUSIONS: Trifocal IOLs induced increased straylight, but it was limited to lower angles, which may cause difficulties detecting these effects using a standard clinical approach. The latest IOL designs featuring chromatic aberration correction at far focus seem more susceptible than the established trifocal IOLs to inducing a glare phenomenon.


Assuntos
Cristalino , Lentes Intraoculares , Presbiopia , Humanos , Ofuscação , Presbiopia/cirurgia , Óculos , Desenho de Prótese
13.
Klin Monbl Augenheilkd ; 241(1): 75-83, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38242135

RESUMO

Cataract is among the leading causes of visual impairment worldwide. Innovations in treatment have drastically improved patient outcomes, but to be properly implemented, it is necessary to have the right diagnostic tools. This review explores the cataract grading systems developed by researchers in recent decades and provides insight into both merits and limitations. To this day, the gold standard for cataract classification is the Lens Opacity Classification System III. Different cataract features are graded according to standard photographs during slit lamp examination. Although widely used in research, its clinical application is rare, and it is limited by its subjective nature. Meanwhile, recent advancements in imaging technology, notably Scheimpflug imaging and optical coherence tomography, have opened the possibility of objective assessment of lens structure. With the use of automatic lens anatomy detection software, researchers demonstrated a good correlation to functional and surgical metrics such as visual acuity, phacoemulsification energy, and surgical time. The development of deep learning networks has further increased the capability of these grading systems by improving interpretability and increasing robustness when applied to norm-deviating cases. These classification systems, which can be used for both screening and preoperative diagnostics, are of value for targeted prospective studies, but still require implementation and validation in everyday clinical practice.


Assuntos
Catarata , Cristalino , Facoemulsificação , Humanos , Estudos Prospectivos , Fotografação/métodos , Catarata/diagnóstico , Acuidade Visual , Facoemulsificação/métodos
14.
Ophthalmol Ther ; 13(3): 791-800, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38244181

RESUMO

INTRODUCTION: The aim of this study was to analyze posterior surface opacification in explanted silicone intraocular lenses (IOLs) with clinicopathologic correlation to asteroid hyalosis. METHODS: In a laboratory setup, 12 explanted silicone IOLs underwent laboratory analyses, including light microscopy, scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy for elemental composition (EDX). Relevant clinical data were obtained for each case, including gender, age at IOL implantation, dates of implantation and explantation, as well as history of neodymium-dopped yttrium aluminum garnet (Nd:YAG) laser treatments or other opacification removal attempts. High-resolution optical coherence tomography (OCT) images were obtained in vitro with an anterior segment OCT device (Anterion, Heidelberg Engineering, Heidelberg, Germany). RESULTS: Calcification located at the posterior optic surface of each lens was identified through SEM and EDX analyses, revealing deposits composed of hydroxyapatite. In all cases, IOL polishing using Nd:YAG laser had been attempted prior to IOL exchange. The clinical functional data showed that this type of IOL opacity led to increase in straylight and subjective symptoms of glare. CONCLUSIONS: Silicone IOLs can develop posterior surface calcification in eyes with asteroid hyalosis. There are mechanical techniques of cleaning the IOL surface but in many cases, IOL explantation is the only sustainable way to reduce the patients' straylight levels and glare symptoms. Due to the risk of posterior surface calcification, silicone IOL implantation should be avoided in eyes with asteroid hyalosis.

15.
J Refract Surg ; 40(1): e48-e56, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38190558

RESUMO

PURPOSE: To evaluate the biomechanical longitudinal variability and progression of tomographically normal fellow eyes of patients with keratoconus. METHODS: Of 513 patients with keratoconus, 30 patients with tomographically normal fellow eyes were included in this study. Tomographic and biomechanical parameters of the Pentacam and Corvis ST (Oculus Optikgeräte GmbH) were analyzed in multiple follow-up examinations, including the ABCD grading, Belin/Ambrósio Enhanced Ectasia total deviation index (BAD-D), Corvis Biomechanical Index (CBI), Corvis Biomechanical Factor (CBiF), and Tomographic and Biomechanical Index (TBI). A mixed regression model was applied. The results were compared to a healthy control group (n = 17) and a keratoconus group (n = 20). RESULTS: Within a maximum observation period of 3.3 years, no fellow eye (0%) showed a progression to tomographically evident keratoconus. No significant change in tomographic or biomechanical parameters was detected over the study period. The indices BAD-D, CBI, CbiF, and TBI exhibited a certain variability over time, whereas the tomographic ABC parameters and maximum keratometry barely changed. This was also shown in the control group and for all parameters in the keratoconus group, except the TBI. CONCLUSIONS: During the observation period none of the normal fellow eyes progressed to tomographically detectable keratoconus. However, biomechanical parameters CBI, CbiF, and TBI showed pathological values in 43.3% of eyes and certain variability. Subsequent studies with a longer observation period are warranted to confirm the biomechanical trends seen in this study and to rate the ability of single measurements to diagnose early keratoconus. [J Refract Surg. 2024;40(1):e48-e56.].


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Dilatação Patológica/diagnóstico
16.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-38242162

RESUMO

Although the safety of phakic intraocular lenses (pIOLs) has been continuously improved over 70-years of development, high endothelial cell losses can occur even with current pIOL models. Numerous studies have demonstrated that the distance of a pIOL to the corneal endothelium plays a crucial role in the extent of endothelial cell loss. For this reason alone, higher endothelial cell loss tends to be observed with anterior chamber lenses than with posterior chamber lenses. Adequate preoperative anterior chamber depth is essential, at least for iris-fixed pIOLs, in order to ensure a safe distance from the endothelium. However, the anterior chamber becomes shallower with age and therefore it may be useful to consider patient age in the safety criteria. Although endothelial cell loss is generally low with current pIOL models, regular monitoring of the endothelial cell density remains essential due to large interindividual differences in patients with pIOLs. If the endothelial cell loss is greater than expected and the follow-up visits confirm the trend, the pIOL should be explanted without delay. The endothelial reserve should be considered on an individual basis by taking into account patient age, physiological endothelial cell loss, and loss due to further surgery. With careful indication and long-term patient care, pIOLs remain a safe treatment option.

18.
Eye (Lond) ; 38(1): 54-60, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37479803

RESUMO

Anti-VEGF therapies are associated with significant gains in visual acuity and fluid resolution in the treatment of diabetic macular oedema (DMO) and have become the standard of care. However, despite their efficacy, outcomes can be unpredictable, vary widely between individual eyes, and a large proportion of patients have persistent fluid following initial treatment, with a negative impact on visual outcomes. Anatomical parameters measured by optical coherence tomography (OCT), in addition to visual acuity, are key to monitoring treatment effectiveness and guiding retreatment decisions; however, existing guidelines on the management of DMO lack clear recommendations for interpretation of OCT parameters, or proposed thresholds of various markers to guide retreatment decisions. Although central subfield thickness (CSFT) has been widely used as a marker for retreatment decisions in clinical trials in DMO, and a reduction in CSFT has generally been shown to accompany improvements in best-corrected visual acuity with treatment, analyses of the relationship between these parameters show that the correlation is small to moderate. A more direct relationship can be seen between an increased magnitude of CSFT fluctuations over time and poorer visual acuity, suggesting that control of CSFT could be important in maximising visual outcomes. The relationship between visual outcomes and qualitatively assessed intraretinal fluid and subretinal fluid is also unclear, although quantitative assessments of fluid parameters suggest that untreated intraretinal fluid and subretinal fluid negatively impact visual outcomes. These findings highlight a need for clearer guidelines on the management of retinal fluid to improve visual outcomes for patients with DMO.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Edema Macular , Humanos , Edema Macular/diagnóstico , Edema Macular/tratamento farmacológico , Retina , Retinopatia Diabética/diagnóstico , Retinopatia Diabética/terapia , Retinopatia Diabética/complicações , Resultado do Tratamento , Tomografia de Coerência Óptica/métodos , Biomarcadores , Injeções Intravítreas , Inibidores da Angiogênese/uso terapêutico
20.
J Cataract Refract Surg ; 50(1): 84-94, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-38133648

RESUMO

The pinhole effect is commonly used to discriminate uncorrected refractive error from ocular diseases. A small aperture limits the width of light beams entering the eye, thus increasing the depth of focus. The pinhole effect has also been used in spectacles, contact lenses, corneal inlays, and intraocular lenses (IOLs) to improve reading by compensating for loss of accommodative function. Pinhole spectacles improve near visual acuity, but reduce reading speed, increase interblink interval, and decrease tear break-up time. For contact lenses and IOLs, pinhole devices are usually used in the nondominant eye, which allow compensation of various refractive errors and decrease spectacle dependence. Pinhole corneal inlays are implanted during laser in situ keratomileusis or as a separate procedure. Pinhole IOLs are gaining popularity, particularly as they do not bring a risk of a local inflammatory reaction as corneal inlays do. Disadvantages of using the pinhole effect include high susceptibility to decentration, decrease in retinal luminance levels, and difficulties in performing fundus examinations or surgery in eyes with implanted devices. There are also concerns regarding perceptive issues with different retinal illuminances in the 2 eyes (the Pulfrich effect).


Assuntos
Lentes de Contato , Lentes Intraoculares , Erros de Refração , Humanos , Visão Ocular , Acuidade Visual , Acomodação Ocular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA