1.
Anal Biochem ; 685: 115386, 2024 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-37977214

RESUMO

In this study, the highly risky drug Edoxaban (EDX), which can threaten life and cause bleeding, was electro analytically evaluated. The electrochemical behavior of EDX was investigated using glassy carbon electrode (GCE) and boron-doped diamond electrode (BDDE). In this study, for the first time, a simple, rapid, sensitive, and selective voltammetric technique was developed by using different electrodes for the electrochemical characterization and detection of EDX. The optimized voltammetric technique showed anodic signals of EDX at +1.09 V and +1.08 V on GCE and BDDE, respectively, in BR (pH 5.0) solution. The developed voltammetric method provided a very good analytical working range for EDX in BR (pH 5.0) solution on GCE and BDDE, covering concentration ranges from 1.84 µM to 12.88 µM and from 3.68 µM to 14.72 µM, respectively. The limits of detection for EDX on GCE and BDDE under these experimental conditions were calculated as 0.24 µM and 0.57 µM, respectively. The developed voltammetric methods on both electrodes were successfully applied to urine and tablet samples. Additionally, the obtained voltammetric results were compared with UV-Vis spectroscopy results.


Assuntos
Boro , Carbono , Carbono/química , Boro/química , Análise Custo-Benefício , Eletrodos , Técnicas Eletroquímicas
2.
Daru ; 31(2): 233-241, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37695455

RESUMO

OBJECTIVES: The anticoagulant drug edoxaban has a blood thinning mechanism of action. In this study, a pencil graphite electrode was electrochemically activated at + 1.4 V for 60 s. in a Britton-Robinson (pH 9.0) supporting electrolyte solution. EVIDENCE ACQUISITION: A simple, fast, and sensitive electrochemical procedure was developed using cyclic voltammetry and square wave voltammetry techniques. It was observed that edoxaban gave a good oxidation signal with cyclic voltammetry technique at a potential of + 0.98 V (vs. Ag/AgCl). RESULTS: This procedure showed a linear response in a Britton-Robinson (pH 9.0) media within the concentration range of 0.2-1.8 µM and limit of detection (LOD) and the limit of quantification (LOQ) values were determined to be 0.073 µM (0.133 µg mL-1) and 0.243 µM (0.443 µg mL-1), respectively. CONCLUSION: The method developed in this study was successfully applied to drug and urine samples. The developed voltammetric method was highly selective and gave satisfactory recovery results in urine and pharmaceutical samples. The results of the voltammetric method were compared with the spectroscopic method and it was determined that the results were compatible.


Assuntos
Grafite , Grafite/química , Anticoagulantes , Análise Custo-Benefício , Eletrodos