Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Prosthet Dent ; 118(5): 672-677, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28385435

RESUMO

STATEMENT OF PROBLEM: The use of computer-aided design and computer-aided manufacturing (CAD-CAM) for metal-ceramic restorations has increased with advances in the technology. However, little is known about the marginal and internal adaptation of restorations fabricated using laser sintering (LS) and soft milling (SM). Moreover, the effects of repeated ceramic firings on the marginal and internal adaptation of metal-ceramic restorations fabricated with LS and SM is also unknown. PURPOSE: The purpose of this in vitro study was to investigate the effects of repeated ceramic firings on the marginal and internal adaptation of metal-ceramic copings fabricated using the lost wax (LW), LS, and SM techniques. MATERIAL AND METHODS: Ten LW, 10 LS, and 10 SM cobalt-chromium (Co-Cr) copings were fabricated for an artificial tooth (Frasaco GmbH). After the application of veneering ceramic (VITA VMK Master; VITA Zahnfabrik), the marginal and internal discrepancies of these copings were measured with a silicone indicator paste and a stereomicroscope at ×100 magnification after the first, second, and third clinical simulated ceramic firing cycles. Repeated measures 2-way ANOVA and the Fisher LSD post hoc test were used to evaluate differences in marginal and internal discrepancies (α=.05). RESULTS: Neither fabrication protocol nor repeated ceramic firings had any statistically significant effect on internal discrepancy values (P>.05). Marginal discrepancy values were also statistically unaffected by repeated ceramic firings (P>.05); however, the fabrication protocol had a significant effect on marginal discrepancy values (P<.001), with LW resulting in higher marginal discrepancy values than LS or SM (P<.05). Marginal discrepancy values did not vary between LS and SM (P>.05). CONCLUSIONS: All groups demonstrated clinically acceptable marginal adaptation after repeated ceramic firing cycles; however, the LS and SM groups demonstrated better marginal adaptation than that of LW group and may be appropriate clinical alternatives to LW.


Assuntos
Cerâmica/uso terapêutico , Desenho Assistido por Computador , Adaptação Marginal Dentária , Planejamento de Prótese Dentária/métodos , Restauração Dentária Permanente/métodos , Ligas de Cromo/uso terapêutico , Prótese Parcial Removível , Humanos , Técnicas In Vitro
2.
J Prosthet Dent ; 117(1): 102-108, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27622786

RESUMO

STATEMENT OF PROBLEM: Proper marginal, axial, and occlusal adaptation of dental restorations is essential for their long-term success. Production protocols including digital impression systems have been developed, but little information is available on the adaptation of zirconia restorations produced via them. PURPOSE: The purpose of this in vitro study was to compare the effects of digital impression protocols on the marginal, axial, and occlusal adaptation of zirconia copings. MATERIAL AND METHODS: Thirty extracted human maxillary premolar teeth without caries or defects were used. The teeth were prepared for zirconia crowns and randomly divided into 3 groups. Zirconia copings were designed at a thickness of 0.5 mm with 30 µm of simulated die spacer starting 1 mm from the margin of preparations. They were produced using computer-aided design-computer-aided manufacture (CAD-CAM) protocol with a conventional impression (group Cn) and 2 different production protocols with digital impressions (group C) and group Tr. The marginal, axial, and occlusal discrepancies of these copings were measured using the silicone replica technique with stereomicroscopy at ×50 magnification, and the data were analyzed with 1-way ANOVAs (α=.05). RESULTS: The mean marginal discrepancy values were 85.6 µm for group Cn, 58.7 µm for group C, and 47.7 µm for the Tr group. Significant differences were found among the production protocols in marginal, axial, and occlusal discrepancies (P<.05). Copings fabricated with the aid of digital impressions had significantly fewer marginal discrepancies than those of group Cn (P<.05). Group Tr exhibited the lowest marginal discrepancy, whereas groups Cn and C demonstrated similar axial adaptations (P>.05), and group Tr revealed the lowest axial discrepancy (P<.05). With regard to the occlusal discrepancy evaluation, group Tr had the lowest discrepancy. However, no significant differences was found between groups C and Cn (P>.05). CONCLUSIONS: The copings produced with the aid of digital impression systems exhibited better marginal and occlusal adaptation than those of the copings produced with the aid of conventional impression.


Assuntos
Técnica de Moldagem Odontológica , Adaptação Marginal Dentária , Planejamento de Prótese Dentária/métodos , Imageamento Tridimensional/métodos , Zircônio , Desenho Assistido por Computador , Restauração Dentária Permanente/métodos , Humanos , Técnicas In Vitro
3.
J Prosthet Dent ; 117(1): 81-86, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27492985

RESUMO

STATEMENT OF PROBLEM: To prevent the loosening of implant screws, clinicians should be aware of the output torque values needed to achieve the desired preload. Accurate torque-control devices are crucial in this regard; however, little information is currently available comparing the accuracy of mechanical with that of electronic torque-control devices. PURPOSE: The purpose of this in vitro study was to identify and compare the accuracy of different types of torque-control devices. MATERIAL AND METHODS: Devices from 5 different dental implant manufacturers were evaluated, including 2 spring-type (Straumann, Implance) mechanical devices (MTLD), 2 friction-type (Biohorizons, Dyna) MTLDs, and 1 (Megagen) electronic torque-control device (ETLD). For each manufacturer, 5 devices were tested 5 times with a digital torque tester, and the average for each device was calculated and recorded. The percentage of absolute deviations from the target torque values (PERDEV) were calculated and compared by using 1-way ANOVA. A 1-sample t test was used to evaluate the ability of each device to achieve its target torque value within a 95% confidence interval for the true population mean of measured values (α=.05 for all statistical analyses). RESULTS: One-way ANOVAs revealed statistically significant differences among torque-control devices (P<.001). ETLD showed higher PERDEVs (28.33 ±9.53) than MTLDs (P<.05), whereas PERDEVS of friction-type (7.56 ±3.64) and spring-type (10.85 ±4.11) MTLDs did not differ significantly. In addition, devices produced by Megagen had a significantly higher (P<.05) PERDEV (28.33 ±9.53) other devices, whereas no differences were found in devices manufactured by Biohorizons (7.31 ±5.34), Dyna (7.82 ±1.08), Implance (8.43 ±4.77), and Straumann (13.26 ±0.79). However, 1-sample t tests showed none of the torque-control devices evaluated in this study were capable of achieving their target torque values (P<.05). CONCLUSIONS: Within the limitations of this in vitro study, MTLDs were shown to be significantly more accurate than ETLDs. However, none of the torque-control devices evaluated were able to meet their target torque values successfully.


Assuntos
Implantes Dentários , Instrumentos Odontológicos , Técnicas In Vitro , Torque
4.
J Prosthet Dent ; 116(3): 368-74, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27130177

RESUMO

STATEMENT OF PROBLEM: Marginal and axial discrepancies of metal ceramic restorations are key to their long-term success. Little information is available for metal ceramic restorations fabricated with soft metal milling and laser sintering technologies. PURPOSE: The purpose of this in vitro study was to compare the marginal, axial, and occlusal discrepancies in single-unit metal ceramic restorations fabricated with new production techniques with those in a single-unit restoration fabricated using a conventional technique. MATERIAL AND METHODS: After the artificial tooth was prepared, impressions were made, and 40 dies were obtained. Dies were randomly divided into 4 groups (n=10). Cobalt-chromium (Co-Cr) cast (C), hard metal milled (HM), laser sintered (LS), and soft metal milled (SM) copings were fabricated. Marginal, axial, and occlusal discrepancies of these copings were measured using the silicone replica technique before and after the application of veneering ceramic. Data were analyzed with repeated measurements 2-way ANOVAs and Bonferroni post hoc tests (α=.05). RESULTS: Significant differences were found in the increase of marginal discrepancy after the application of veneering ceramic in the LS group (P=.016). However, no significant differences in marginal discrepancy were found whether veneering ceramic was applied to copings before or after in the other groups (P>.05). With regard to marginal and occlusal discrepancies, significant differences were found among the production techniques (P<.001 and P<.05, respectively). No significant differences in axial discrepancies were found among the groups (P>.05). CONCLUSION: This in vitro study showed that metal ceramic restorations produced with HM and newly introduced SM techniques exhibited better marginal adaptations than those produced with the LS or C technique.


Assuntos
Planejamento de Prótese Dentária/métodos , Restauração Dentária Permanente/métodos , Ligas Metalo-Cerâmicas/uso terapêutico , Ligas de Cromo/uso terapêutico , Desenho Assistido por Computador , Adaptação Marginal Dentária/normas , Oclusão Dentária , Planejamento de Prótese Dentária/instrumentação , Planejamento de Prótese Dentária/normas , Restauração Dentária Permanente/instrumentação , Restauração Dentária Permanente/normas , Humanos , Técnicas In Vitro , Dente Artificial
5.
Scanning ; 38(1): 63-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26381904

RESUMO

The aim of this study was to investigate the effect of preheating on microshear bond strength (MSBS) of silorane and methacrylate-based composite resins to human dentin. The teeth were randomly divided into three main groups: (1) composite resins were heated upto 68 °C; (2) cooled to 4 °C; and (3) control [room temperature (RT)]. Each group was then randomly subdivided into four subgroups according to adhesive system used [Solobond M (Voco), All Bond SE (Bisco), Clearfil SE Bond (CSE) (Kuraray), Silorane adhesive system (SAS) (3M ESPE)]. Resin composite cylinders were formed (0.9 mm diameter × 0.7 mm length) and MSBS of each specimen was tested. The preheated groups exhibited the highest MSBS (p < 0.001) and the groups cooled to 4 °C exhibited the lowest MSBS (p < 0.001). The CSE showed higher MSBS than the other adhesives (p < 0.001). This study concludes that preheating of composite resins may be an alternative way to increase the MSBS of composites on dentin.


Assuntos
Resinas Compostas/farmacologia , Dentina/metabolismo , Temperatura Alta , Fenômenos Mecânicos , Metacrilatos/farmacologia , Resinas de Silorano/farmacologia , Resinas Compostas/efeitos da radiação , Humanos , Metacrilatos/efeitos da radiação , Resinas de Silorano/efeitos da radiação , Resultado do Tratamento
6.
J Prosthodont ; 25(5): 386-91, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25996288

RESUMO

PURPOSE: This study evaluated the effect of delayed bonding and antioxidant application (AA, 10% sodium ascorbate) after internal bleaching (35% carbamide peroxide) on the shear bond strength of an adhesive cement to enamel. MATERIALS AND METHODS: Eighty-four human maxillary central incisors were endodontically treated. The control group remained unbleached with no AA. Experimental groups were all internally bleached. The buccal enamel was finished and polished with metallographic paper to a refinement of #600, in order to obtain a 5-mm(2) flat bonding area. An adhesive cement (Clearfil Esthetic) was placed into a plastic tube with internal diameter of 3 mm and a 3-mm height and cured on the enamel. Bonding occurred either immediately after bleaching (group Im), a 7-day delay (group 7), or a 14-day delay (group 14), and half the specimens were treated with antioxidant application (groups Im-AA, 7-AA, and 14-AA). Shear bond strength testing was performed on a universal testing machine, and data were analyzed with ANOVA and Fisher test (5%). RESULTS: Delaying of bonding is a useful factor for enhancing shear bond strength (p < 0.05), whereas AA only enhanced shear bond strength after 7 days delayed bleaching (p < 0.05). The highest bond strength was noted in groups 7-AA (20.51 ± 4.5 MPa), 14 (19.82 ± 4.6), 14-AA (20.27 ± 4.4), and control (20.51 ± 5.1), which were not significantly different from each other. CONCLUSIONS: After internal bleaching, adhesive cementation to enamel is recommended only when delayed 14 days, or delayed 7 days with sodium ascorbate application.


Assuntos
Resinas Compostas , Colagem Dentária , Clareamento Dental , Cimentos Dentários , Esmalte Dentário , Análise do Estresse Dentário , Estética Dentária , Humanos , Teste de Materiais , Peróxidos , Resistência ao Cisalhamento , Ureia
7.
J Adv Prosthodont ; 7(1): 15-20, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25722832

RESUMO

PURPOSE: The aim of this study was to evaluate whether the push-out bond strength varies between oval and circular fiber posts, and to examine the effect on the resin cement thicknesses around the posts. MATERIALS AND METHODS: Eighteen mandibular premolar roots were separated into two groups for oval and circular fiber posts systems. Post spaces were prepared and fiber posts were luted to the post spaces. Roots were cut horizontally to produce 1-mm-thick specimens. Resin cement thicknesses were determined with a metallographic optical microscope and push-out tests were done. RESULTS: No significant differences were observed in terms of push-out bond strength between the oval and circular fiber posts (P>.05) The resin cement thicknesses of the oval posts were greater than those of the circular posts group in the coronal, middle and apical specimens (P<.05). CONCLUSION: In the light of these results, it can be stated that resin cement thickness does not affect the push-out bond strength.

8.
J Adv Prosthodont ; 6(4): 317-24, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25177476

RESUMO

PURPOSE: This study was to evaluate the effect of grinding of the inner metal surface during the porcelain try-in stage on metal-porcelain bonding considering the maximum temperature and the vibration of samples. MATERIALS AND METHODS: Ninety-one square prism-shaped (1 × 1 × 1.5 mm) nickel-chrome cast frameworks 0.3 mm thick were prepared. Porcelain was applied on two opposite outer axial surfaces of the frameworks. The grinding was performed from the opposite axial sides of the inner metal surfaces with a low-speed handpiece with two types of burs (diamond, tungsten-carbide) under three grinding forces (3.5 N, 7 N, 14 N) and at two durations (5 seconds, 10 seconds). The shear bond strength (SBS) test was performed with universal testing machine. Statistical analyzes were performed at 5% significance level. RESULTS: The samples subjected to grinding under 3.5 N showed higher SBS values than those exposed to grinding under 7 N and 14 N (P<.05). SBS values of none of the groups differed from those of the control group (P>.05). The types of bur (P=.965) and the duration (P=.679) did not affect the SBS values. On the other hand, type of bur, force applied, and duration of the grinding affected the maximum temperatures of the samples, whereas the maximum vibration was affected only by the type of bur (P<.05). CONCLUSION: Grinding the inner metal surface did not affect the metal-porcelain bond strength. Although the grinding affected the maximum temperature and the vibration values of the samples, these did not influence the bonding strength.

9.
J Adv Prosthodont ; 5(4): 434-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24353882

RESUMO

PURPOSE: The aim of the present study was to evaluate the effects of posts with different morphologies on stress distribution in an endodontically treated mandibular premolar by using finite element models (FEMs). MATERIALS AND METHODS: A mandibular premolar was modeled using the ANSYS software program. Two models were created to represent circular and oval fiber posts in this tooth model. An oblique force of 300 N was applied at an angle of 45° to the occlusal plane and oriented toward the buccal side. von Mises stress was measured in three regions each for oval and circular fiber posts. RESULTS: FEM analysis showed that the von Mises stress of the circular fiber post (426.81 MPa) was greater than that of the oval fiber post (346.34 MPa). The maximum distribution of von Mises stress was in the luting agent in both groups. Additionally, von Mises stresses accumulated in the coronal third of root dentin, close to the post space in both groups. CONCLUSION: Oval fiber posts are preferable to circular fiber posts in oval-shaped canals given the stress distribution at the post-dentin interface.

10.
J Adv Prosthodont ; 5(3): 256-61, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24049566

RESUMO

PURPOSE: Occlusal splints are commonly used to prevent tooth wear caused by bruxism. However, the effects of splints on occlusion are still unclear. Although it is rarely alluded in literature, splints can provoke severe occlusal alterations and other complications. This study was aimed to identify differences in the responses of individuals with bruxism and healthy individuals to a full-arch maxillary stabilization splint in terms of occlusal changes. MATERIALS AND METHODS: Occlusal contacts in 20 (5 male, 15 female) bruxism patients and 20 (5 male, 15 female) controls with normal occlusion were evaluated before and after occlusal splint therapy. T-Scan III, a computerized occlusal analysis system, was used to simultaneously measure occlusion and disclusion times as well as left-right and anterior-posterior contact distributions before splint therapy and 3 months after therapy. Wilcoxon and Mann-Whitney U tests were used for statistical analyses (α=.05). RESULTS: No differences were found in the posterior contact of bruxism patients before and after stabilization splint treatment. However, differences in posterior contact were observed between bruxists and normal individuals prior to treatment, and this difference disappeared following treatment. CONCLUSION: The results of this study showed the use of a stabilization splint may not have an effect on occlusion. However, the area of posterior occlusal contact among bruxists was found to be greater than that of normal individuals. According to this study, the clinical use of splints may be harmless.

11.
Springerplus ; 2(1): 40, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23504412

RESUMO

In this study, we have explored the prospect of assessing and following level of total denture adaptation by use of EMG signals recorded during gum chewing. Total of 14 edentulous patients, 6 women and 8 men, with an average age of 63±9 years, were recruited. Separate EMG recordings were obtained from left and right temporalis and masseter muscles of the patients for a period of 10 seconds, while they were chewing a sugar-free gum on their left and right sides. EMG recordings were repeated at three times: before, right after, and six months after the placement of the denture. We have tried to standardize environmental and individual factors during EMG recordings. The EMG data have been pre-processed and analyzed using Discrete Wavelet Transform (DWT) and obtained features were statistically evaluated using the paired sample t-test. Chewing activity on the right and left side is analyzed by making comparisons of muscle activity between before and right-after cases and before and six-months-after denture fixation cases. A comparison between right and left side mastication is also made at different time points. We have suggested and implemented a new test and comparison procedure in order to assess adaptation to denture fixation using EMG analysis. In this study, the results indicate that DWT based EMG analysis is instrumental in evaluating denture adaptation and as time progresses the adaptation to denture and hence chewing efficiency increases in patients with total denture replacement.

12.
Eur J Dent ; 7(Suppl 1): S099-S104, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24966738

RESUMO

OBJECTIVES: The objective of this study is to evaluate the frequency and distribution of early tooth loss and endodontic treatment needs of permanent first molars in a Turkish pediatric population. MATERIALS AND METHODS: A total of 7,895 panoramic radiographs taken for routine dental examination at the Department of Oral Maxillofacial Radiology between 2008 and 2012 years were investigated. Two independent specialists evaluated early tooth loss and endodontic treatment needs of permanent first molars using panoramic radiography and patient anamnesis forms. The teeth were classified according to the following data: (a) Missing teeth, (b) teeth requiring extraction, (c) endodontically treated teeth (ETT), (d) teeth requiring endodontic therapy. The data also classified according to four factors: Age group (6-12 and 13-16), gender (boy and girl), jaw (mandible and maxilla) and side (right and left). A Chi-square test was used for statistical analyses. RESULTS: A total of 19,488 and 12,092 teeth were evaluated in the child group and adolescent group respectively. All data were higher in adolescents than children (P < 0.001). For gender factor, only ETT was higher in girls than it was in boys (P < 0.001). For the jaw factor, all data were higher (P < 0.001) in mandible than in the maxilla. For the side factor, no statistical difference existed between right and left. CONCLUSIONS: Early tooth loss and endodontic treatment needs of permanent first molars showed variability according to age groups and jaws. When the results were compared according to the side and gender factors, no statistical difference was found (P > 0.05) except with the data of ETT in gender groups.

13.
J Adv Prosthodont ; 4(4): 192-6, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23236570

RESUMO

PURPOSE: The purpose of this study was to evaluate the effect of provisional cement removal by different dentin cleaning protocols (dental explorer, pumice, cleaning bur, Er:YAG laser) on the shear bond strength between ceramic and dentin. MATERIALS AND METHODS: In total, 36 caries-free unrestored human third molars were selected as tooth specimens. Provisional restorations were fabricated and cemented with eugenol-free provisional cement. Then, disc-shaped ceramic specimens were fabricated and randomly assigned to four groups of dentin cleaning protocols (n = 9). Group 1 (control): Provisional cements were mechanically removed with a dental explorer. Group 2: The dentin surfaces were treated with a cleaning brush with pumice Group 3: The dentin surfaces were treated with a cleaning bur. Group 4: The provisional cements were removed by an Er:YAG laser. Self-adhesive luting cement was used to bond ceramic discs to dentin surfaces. Shear bond strength (SBS) was measured using a universal testing machine at a 0.05 mm/min crosshead speed. The data were analyzed using a Kolmogorov Smirnov, One-way ANOVA and Tukey HSD tests to perform multiple comparisons (α=0.05). RESULTS: THE DENTIN CLEANING METHODS DID NOT SIGNIFICANTLY AFFECT THE SBS OF CERAMIC DISCS TO DENTIN AS FOLLOWS: dental explorer, pumice, cleaning bur, and Er:YAG laser. CONCLUSION: The use of different cleaning protocols did not affect the SBS between dentin and ceramic surfaces.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA