Resultados 1 - 9 de 9
Filtrar
1.
IEEE Trans Biomed Eng ; 69(8): 2679-2690, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35180073

RESUMO

OBJECTIVE: Although plane wave imaging (PWI) with multiple plane waves (PWs) steered at different angles enables ultrafast three-dimensional (3-D) ultrasonic imaging, there is still a challenging tradeoff between image quality and frame rate. To address this challenge, we recently proposed the aperiodic PWI (APWI) with mathematical analysis and simulation study. In this paper, we demonstrate the feasibility of APWI and evaluate the performance with phantom and in vivo experiments. METHODS: APWI with a concentric ring angle pattern (APWI-C) and APWI with a sunflower pattern (APWI-S) are evaluated. For experimental verification of the methods, the experimental results are compared with simulation results in terms of the spatial resolution and the mainlobe-to-sidelobe ratio. In addition, the performance of APWI is compared with that of conventional PWI by using a commercial phantom. To examine the potential for clinical use of APWI, a gallstone phantom study and an in vivo carotid artery experiment are also conducted. RESULTS: In the phantom study, the APWI methods provide a contrast ratio approximately 2-3 dB higher than that of PWI. In a gallstone experiment, the proposed methods yield 3-D rendered stone images more similar to the real stones than PWI. In the in vivo carotid artery images, APWI reduces the clutter artifacts inside the artery. CONCLUSION: Phantom and in vivo studies show that the APWI enhances the contrast without compromising the spatial resolution and frame rate. SIGNIFICANCE: This study experimentally demonstrates the feasibility and advantage of APWI for ultrafast 3-D ultrasonic imaging.


Assuntos
Cálculos Biliares , Artefatos , Artérias Carótidas/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Ultrassonografia/métodos
2.
Sensors (Basel) ; 20(15)2020 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-32727146

RESUMO

Ultrasound measurements of detrusor muscle thickness have been proposed as a diagnostic biomarker in patients with bladder overactivity and voiding dysfunction. In this study, we present an approach based on deep learning (DL) and dynamic programming (DP) to segment the bladder sac and measure the detrusor muscle thickness from transabdominal 2D B-mode ultrasound images. To assess the performance of our method, we compared the results of automated methods to the manually obtained reference bladder segmentations and wall thickness measurements of 80 images obtained from 11 volunteers. It takes less than a second to segment the bladder from a 2D B-mode image for the DL method. The average Dice index for the bladder segmentation is 0.93 ± 0.04 mm, and the average root-mean-square-error and standard deviation for wall thickness measurement are 0.7 ± 0.2 mm, which is comparable to the manual ground truth. The proposed fully automated and fast method could be a useful tool for segmentation and wall thickness measurement of the bladder from transabdominal B-mode images. The computation speed and accuracy of the proposed method will enable adaptive adjustment of the ultrasound focus point, and continuous assessment of the bladder wall during the filling and voiding process of the bladder.


Assuntos
Manejo de Espécimes , Bexiga Urinária , Automação , Humanos , Ultrassonografia , Bexiga Urinária/diagnóstico por imagem
3.
IEEE Access ; 8: 76276-76286, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32612897

RESUMO

Sparse arrays reduce the number of active channels that effectively increases the inter-element spacing. Large inter-element spacing results in grating lobe artifacts degrading the ultrasound image quality and reducing the contrast-to-noise ratio. A deep learning-based custom algorithm is proposed to estimate inactive channel data in periodic sparse arrays. The algorithm uses data from multiple active channels to estimate inactive channels. The estimated inactive channel data effectively reduces the inter-element spacing for beamforming, thus suppressing the grating lobes. Estimated inactive element channel data was combined with active element channel data resulting in a pseudo fully sampled array. The channel data was beamformed using a simple delay-and-sum method and compared with the sparse array and fully sampled array. The performance of the algorithm was validated using a wire target in a water tank, multi-purpose tissue-mimicking phantom, and in-vivo carotid data. Grating lobes suppression up to 15.25 dB was observed with an increase in contrast-to-noise (CNR) for the pseudo fully sampled array. Hypoechoic regions showed more improvement in CNR than hyperechoic regions. Root-mean-square error for unwrapped phase between fully sampled array and the pseudo fully sampled array was low, making the estimated data suitable for Doppler and elastography applications. Speckle pattern was also preserved; thus, the estimated data can also be used for quantitative ultrasound applications. The algorithm can improve the quality of sparse array images and has applications in small scale ultrasound devices and 2D arrays.

4.
PLoS One ; 15(1): e0226994, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31929558

RESUMO

OBJECTIVES: To evaluate the predictive performance of comb-push ultrasound shear elastography for the differentiation of reactive and metastatic axillary lymph nodes. METHODS: From June 2014 through September 2018, 114 female volunteers (mean age 58.1±13.3 years; range 28-88 years) with enlarged axillary lymph nodes identified by palpation or clinical imaging were prospectively enrolled in the study. Mean, standard deviation and maximum shear wave elastography parameters from 117 lymph nodes were obtained and compared to fine needle aspiration biopsy results. Mann-Whitney U test and ROC curve analysis were performed. RESULTS: The axillary lymph nodes were classified as reactive or metastatic based on the fine needle aspiration outcomes. A statistically significant difference between reactive and metastatic axillary lymph nodes was observed based on comb-push ultrasound shear elastography (CUSE) results (p<0.0001) from mean and maximum elasticity values. Mean elasticity showed the best separation with a ROC analysis resulting in 90.5% sensitivity, 94.4% specificity, 0.97 area under the curve, 95% positive predictive value, and 89.5% negative predictive value with a 30.2-kPa threshold. CONCLUSIONS: CUSE provided a quantifiable parameter that can be used for the assessment of enlarged axillary lymph nodes to differentiate between reactive and metastatic processes.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Linfonodos/diagnóstico por imagem , Metástase Linfática/diagnóstico por imagem , Valor Preditivo dos Testes , Ultrassonografia Mamária/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Biópsia por Agulha Fina/normas , Diagnóstico Diferencial , Técnicas de Imagem por Elasticidade/normas , Feminino , Humanos , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Ultrassonografia Mamária/normas
5.
Artigo em Inglês | MEDLINE | ID: mdl-31180847

RESUMO

This work extends the effective aperture size by coherently compounding the received radio frequency data from multiple transducers. As a result, it is possible to obtain an improved image, with enhanced resolution, an extended field of view (FoV), and high-acquisition frame rates. A framework is developed in which an ultrasound imaging system consisting of N synchronized matrix arrays, each with partly shared FoV, take turns to transmit plane waves (PWs). Only one individual transducer transmits at each time while all N transducers simultaneously receive. The subwavelength localization accuracy required to combine information from multiple transducers is achieved without the use of any external tracking device. The method developed in this study is based on the study of the backscattered echoes received by the same transducer and resulting from a targeted scatterer point in the medium insonated by the multiple ultrasound probes of the system. The current transducer locations along with the speed of sound in the medium are deduced by optimizing the cross correlation between these echoes. The method is demonstrated experimentally in 2-D for two linear arrays using point targets and anechoic lesion phantoms. The first demonstration of a free-hand experiment is also shown. Results demonstrate that the coherent multi-transducer ultrasound imaging method has the potential to improve ultrasound image quality, improving resolution, and target detectability. Compared with coherent PW compounding using a single probe, lateral resolution improved from 1.56 to 0.71 mm in the coherent multi-transducer imaging method without acquisition frame rate sacrifice (acquisition frame rate 5350 Hz).

6.
J Acoust Soc Am ; 145(3): EL236, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-31067972

RESUMO

Sparse array (SA) is an approach to reduce the number of system channels. However, SA suffers from grating lobe (GL) artefacts due to the sparsity of array aperture resulting in degradation of the ultrasound image quality. Based on a given or known data sets of radio frequency (RF) echo acquired from active elements of an array, RF echo data in unknown and/or inactive elements of array can be created virtually and used to suppress the GL artefact in SA. This letter presents gap-filling (GF) approaches to generate channel data, which are not physically acquired. It is demonstrated that the proposed GF technique can reduce the artefacts of SA by filling the gaps in the array aperture. Simulation results show that the GF technique can suppress the GL level of SA by up to 16 dB. Also, the GF technique can improve the image quality of fully sampled arrays with small number of active elements.


Assuntos
Ondas Ultrassônicas , Ultrassonografia/métodos , Acústica , Algoritmos , Modelos Teóricos , Ultrassonografia/normas
7.
Sensors (Basel) ; 19(4)2019 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-30791619

RESUMO

It has been reported that the frequency bandwidth of capacitive micro-machined ultrasonic transducers (CMUTs) is relatively broader than that of other ceramic-based conventional ultrasonic transducers. In this paper, a feasibility study for orthogonal chirp coded excitation to efficiently make use of the wide bandwidth characteristic of CMUT array is presented. The experimental result shows that the two orthogonal chirps mixed and simultaneously fired in CMUT array can be perfectly separated in decoding process of the received echo signal without sacrificing the frequency bandwidth each chirp. The experimental study also shows that frequency band-divided orthogonal chirps are successfully compressed to two short pulses having the -6 dB axial beam-width of 0.26- and 0.31-micro second for high frequency and low frequency chirp, respectively. B-mode image simulations are performed using Field II to estimate the improvement of image quality assuming that the orthogonal chirps designed for the experiments are used for simultaneous transmission multiple-zone focusing (STMF) technique. The simulation results show that the STMF technique used in CMUT array can improve the lateral resolution up to 77.1% and the contrast resolution up to 74.7%, respectively. It is shown that the penetration depth also increases by more than 3 cm.

8.
Acad Radiol ; 25(11): 1388-1397, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29573939

RESUMO

RATIONALE AND OBJECTIVES: Low specificity of traditional ultrasound in differentiating benign from malignant thyroid nodules leads to a great number of unnecessary (ie, benign) fine-needle aspiration biopsies that causes a significant financial and physical burden to the patients. Ultrasound shear wave elastography is a technology capable of providing additional information related to the stiffness of tissues. In this study, quantitative stiffness values acquired by ultrasound shear wave elastography in two different imaging planes were evaluated for the prediction of malignancy in thyroid nodules. In addition, the association of elasticity measurements with sonographic characteristics of thyroid gland and nodules is presented. MATERIALS AND METHODS: A total number of 155 patients (106 female and 49 male) (average age 57.48 ± 14.44 years) with 173 thyroid nodules (average size 24.89 ± 15.41 mm, range 5-68 mm) scheduled for fine-needle aspiration biopsy were recruited from March 2015 to May 2017. Comb-push shear elastography imaging was performed at longitudinal and transverse anatomic planes. Mean (Emean) and maximum (Emax) elasticity values were obtained. RESULTS: Measurements at longitudinal view were statistically significantly higher than measurements at transverse view. Nodules with calcifications were associated with increased elasticity, and nodules with a vascular component or within an enlarged thyroid gland (goiter) were associated with a lower elasticity value. Receiver operating characteristic curve analysis was performed for Emean and Emax at each imaging plane and for the average of both planes. Sensitivity of 95.45%, specificity of 86.61%, 0.58 positive predictive value, and 0.99 negative predictive value were achieved by the average of the two planes for each Emean and Emax parameters, with area under the curve of 92% and 93%, and a cutoff value of 49.09 kPa and 105.61 kPa, respectively. CONCLUSIONS: The elastic properties of thyroid nodules showed promise to be a good discriminator between malignant and benign nodules (P < .0001). However, probe orientation and internal features such as calcifications, vascular component, and goiter may influence the final elastography measurements. A larger number of malignant nodules need to be studied to further validate our results.


Assuntos
Técnicas de Imagem por Elasticidade , Nódulo da Glândula Tireoide/diagnóstico por imagem , Adulto , Idoso , Biópsia por Agulha Fina , Estudos de Coortes , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Nódulo da Glândula Tireoide/patologia
9.
Ultrasonics ; 46(2): 148-54, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17382363

RESUMO

The compression error of post-compression based coded excitation techniques increases with decreasing f-number, which causes the elevation of side-lobe levels. In this paper, a post-compression based coded excitation technique with reduced compression errors through dynamic aperture control is proposed. To improve the near-field resolution with no frame rate reduction, the proposed method performs simultaneous transmit multi-zone focusing using two mutually orthogonal complementary Golay codes. In the proposed method, the two mutually orthogonal sequences of length 16 are simultaneously transmitted toward two different focal depths, which are separately compressed into two short pulses on receive after dynamic focusing is performed. After carrying out the same transmit-receive operation for the same scan line with the complementary set of the orthogonal Golay codes, a single scan line with two transmit foci is obtained. The computer simulation results using a linear array with a center frequency of 7.5 MHz and 60% 6 dB bandwidth show that the range side-lobe level can be suppressed below -50 dB, when f-number is maintained not smaller than 3. The performance of the proposed scheme for a smaller f-number of 2 was also verified through actual experiments using a 3.85 MHz curved linear array with 60% 6 dB bandwidth. Both the simulation and experimental results show that the proposed method provides improved lateral resolution compared to the conventional pre-compressed and post-compression based coded excitation imaging using Golay codes.


Assuntos
Algoritmos , Compressão de Dados/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Ultrassonografia/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia/instrumentação