Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Hazard Mater ; 443(Pt A): 130219, 2023 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-36367474

RESUMO

The fate and transport of microplastics (MPs) during deep bed filtration were investigated using combined laboratory experiments and numerical modeling. A series of column experiments were conducted within the designated ranges of six operating parameters (i.e., size of the MP and collector, seepage velocity, porosity, temperature, and ionic strength). A variance-based sensitivity analysis, the Fourier amplitude sensitivity test, was conducted to determine the priority in affecting both the attachment coefficient at the pore scale, and the subsequent stabilized height of the breakthrough curve at the continuum scale, which follows non-monotonic trends with singularity in the size of MP (i.e., 1 µm). Finally, Damkohler numbers were introduced to analyze the dominant mechanisms (e.g., attachment, detachment, or straining) in the coupled hydro-chemical process. The robustness of conceptual frameworks bridges the gap between pore-scale interactions and the explicit MPs removal in the continuum scale, which could support decision-making in determining the priority of parameters to retain MPs during deep bed filtration.


Assuntos
Microplásticos , Areia , Plásticos , Filtração , Porosidade
2.
J Periodontol ; 88(4): 329-337, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27858555

RESUMO

BACKGROUND: This study evaluates occurrence of progressive bone loss (PBL) around implants with different implant surfaces. METHODS: Retrospective examination of 2,517 implants was performed in 903 patients, including 1,147 anodized-surface implants in 454 patients and 1,370 resorbable blasting media (RBM)-surface implants in 449 patients, which were placed from January 2006 to December 2010. Through regular check-up radiographs and records, presence of PBL (up to >50% of fixture length) was investigated. Implant removal for any reason was regarded a failure. RESULTS: In total, 2,186 implants (979 anodized implants and 1,207 RBM implants) in 793 patients were included in this study. PBL was more frequently observed among anodized implants (n = 36 in 21 patients; 4%) than among RBM implants (n = 19 in 14 patients; 2%), and this difference was statistically significant (P <0.001). Occurrence of PBL was significantly influenced by surface modification and implant diameter (odds ratio [OR] of anodized surface = 4.40, 95% confidence interval [CI] = 1.78 to 10.89, P = 0.001; OR of wide implants = 9.62, 95% CI = 1.13 to 81.68, P = 0.038; determined by mixed-effects logistic regression analysis with random patient effect). However, total survival rate was significantly influenced by implant diameter and not by surface modification (P = 0.019), although effect of implant diameter was observed to be significant on anodized implants (P = 0.030). CONCLUSION: Implant surface modification and implant diameter are significantly associated with occurrence of PBL.


Assuntos
Perda do Osso Alveolar/epidemiologia , Implantes Dentários , Idoso , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Progressão da Doença , Técnicas Eletroquímicas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , República da Coreia/epidemiologia , Estudos Retrospectivos , Propriedades de Superfície
3.
Artigo em Inglês | MEDLINE | ID: mdl-19964495

RESUMO

The morphological studies of neuron structures are of great interests for biologists. However, manually detecting dendrites structures is very labor intensive, therefore unfeasible in studies that involve a large number of images. In this paper, we propose an automated neuron detection and description method. The proposed method uses ratios of probability maps from random walk sessions to detect initial seed-points and minimal cost path integrals with Delaunay triangulations.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Microscopia/métodos , Rede Nervosa/citologia , Vias Neurais/citologia , Neurônios/citologia , Reconhecimento Automatizado de Padrão/métodos , Interpretação Estatística de Dados , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA