Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
J Funct Biomater ; 15(5)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38786627

RESUMO

This study aimed to analyze the effect of the height of the proximal axial wall of the prepared tooth and the distance between the adjacent tooth and the prepared tooth on the scan accuracy of intraoral scanners. Ten working casts with maxillary first molars prepared to receive zirconia crowns were randomly obtained from a dental clinic. Each of the 10 casts was scanned using two intraoral scanners (i700; MEDIT and CS3600; Carestream; computer-aided design [CAD] test model, CTM; N = 15 per working cast) 15 times per scanner. Individual dies of the prepared teeth were fabricated, and high-precision scan data were acquired using a laboratory scanner (CAD reference model, CRM; N = 1). CTMs were aligned relative to the prepared tooth of CRMs by using three-dimensional inspection software (Ver 2018.1.0; Control X; 3D Systems). Data were statistically analyzed using an independent t-test and one-way analysis of variance for between-group comparisons (α = 0.05). The inaccuracy in the proximal regions (mesial or distal) of the prepared tooth was higher than that in the buccal and lingual regions (p < 0.05). The scan accuracy was not correlated with the variables when the distance between the adjacent tooth and the prepared tooth was ≥2.0 mm and the height of the proximal axial wall of the prepared tooth was <3.0 mm (p > 0.05). Therefore, an excellent scan accuracy can be obtained using an intraoral scanner when the distance between the adjacent tooth and the prepared tooth is ≥2.0 mm and the proximal axial wall height of the prepared tooth is <3.0 mm.

2.
Sci Rep ; 13(1): 21661, 2023 12 08.
Artigo em Inglês | MEDLINE | ID: mdl-38066236

RESUMO

This clinical study aimed to predict the learning curve of wireless and wired intraoral scanners (IOSs) and to compare the reduction patterns of working time. Overall, 14 participants were enrolled in the study. The intraoral scanning procedure was repeated four times, each using wireless and wired IOSs (i700; MEDIT). The work time from the first to the 600th iterations was predicted using the Wright model. Regarding statistical analysis, the Mann-Whitney U-test was performed for comparison between wireless and wired IOSs and between groups with and without an IOS usage experience, and the Friedman test was performed to evaluate the time reduction (α = 0.05). There was a significant difference between wireless and wired IOSs in the first (P = 0.008) and the third (P = 0.035) iterations. Moreover, the time for 600 iterations was statistically significantly different between wireless and wired IOSs (P < 0.05); however, there was no significant difference after the sixth iteration (e.g., seventh iteration: P = 0.062). In wireless IOS, no significant difference was found between participants with and without an IOS usage experience after the 34th iteration (P = 0.053). The difference in the learning effect between wireless and wired IOSs can be overcome by initial learning; however, an IOS usage experience can affect the learning time of wireless IOSs.


Assuntos
Imageamento Tridimensional , Curva de Aprendizado , Humanos , Desenho Assistido por Computador , Modelos Dentários , Estatísticas não Paramétricas
3.
Phys Rev Lett ; 131(7): 076901, 2023 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-37656841

RESUMO

We report ultrafast x-ray scattering experiments of the quasi-1D charge density wave (CDW) material (TaSe_{4})_{2}I following ultrafast infrared photoexcitation. From the time-dependent diffraction signal at the CDW sidebands we identify a 0.11 THz amplitude mode derived primarily from a transverse acoustic mode of the high-symmetry structure. From our measurements we determine that this mode interacts with the valence charge indirectly through another collective mode, and that the CDW system in (TaSe_{4})_{2}I has a composite nature supporting multiple dynamically active structural degrees of freedom.

4.
Nat Mater ; 22(4): 429-433, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36894771

RESUMO

The lowest-lying fundamental excitation of an incommensurate charge-density-wave material is believed to be a massless phason-a collective modulation of the phase of the charge-density-wave order parameter. However, long-range Coulomb interactions should push the phason energy up to the plasma energy of the charge-density-wave condensate, resulting in a massive phason and fully gapped spectrum1. Using time-domain terahertz emission spectroscopy, we investigate this issue in (TaSe4)2I, a quasi-one-dimensional charge-density-wave insulator. On transient photoexcitation at low temperatures, we find the material strikingly emits coherent, narrowband terahertz radiation. The frequency, polarization and temperature dependences of the emitted radiation imply the existence of a phason that acquires mass by coupling to long-range Coulomb interactions. Our observations underscore the role of long-range interactions in determining the nature of collective excitations in materials with modulated charge or spin order.

5.
J Adv Prosthodont ; 15(1): 1-10, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36908751

RESUMO

PURPOSE: Accuracy of image matching between resting and smiling facial models is affected by the stability of the reference surfaces. This study aimed to investigate the morphometric variations in subdivided facial units during resting, posed and spontaneous smiling. MATERIALS AND METHODS: The posed and spontaneous smiling faces of 33 adults were digitized and registered to the resting faces. The morphological changes of subdivided facial units at the forehead (upper and lower central, upper and lower lateral, and temple), nasal (dorsum, tip, lateral wall, and alar lobules), and chin (central and lateral) regions were assessed by measuring the 3D mesh deviations between the smiling and resting facial models. The one-way analysis of variance, Duncan post hoc tests, and Student's t-test were used to determine the differences among the groups (α = .05). RESULTS: The smallest morphometric changes were observed at the upper and central forehead and nasal dorsum; meanwhile, the largest deviation was found at the nasal alar lobules in both the posed and spontaneous smiles (P < .001). The spontaneous smile generally resulted in larger facial unit changes than the posed smile, and significant difference was observed at the alar lobules, central chin, and lateral chin units (P < .001). CONCLUSION: The upper and central forehead and nasal dorsum are reliable areas for image matching between resting and smiling 3D facial images. The central chin area can be considered an additional reference area for posed smiles; however, special cautions should be taken when selecting this area as references for spontaneous smiles.

6.
J Prosthodont Res ; 67(2): 305-310, 2023 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-35665697

RESUMO

PATIENTS: The patient was a 32-year-old man who underwent amalgam restoration of the mandibular right second molar. An amalgam restoration fracture was diagnosed by intraoral optical coherence tomography (OCT), and pulp exposure was examined during cavity preparation. Subsequently, a definitive ceramic restoration was fabricated, and the marginal fit in the oral cavity was evaluated using the OCT system. DISCUSSION: The existing OCT system cannot acquire images inside the oral cavity because of the large probe size. However, the proposed intraoral OCT system can access the prostheses in the mandibular right second molar. Therefore, dental diagnosis for restoration treatment with dental prosthesis fracture, marginal gap, and pulp exposure after tooth preparation is possible using the proposed intraoral OCT system. CONCLUSIONS: The use of the intraoral OCT system improved dental diagnosis by allowing the dentist to confirm quantitative values through cross-sectional images, rather than that by determining a treatment plan after visual dental diagnosis.


Assuntos
Restaurações Intracoronárias , Tomografia de Coerência Óptica , Humanos , Adulto , Tomografia de Coerência Óptica/métodos , Dente Molar , Preparo da Cavidade Dentária , Boca
8.
Bioengineering (Basel) ; 9(9)2022 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-36134963

RESUMO

The aim of this study is to evaluate the wear volume of interim crowns fabricated using digital light processing 3D printing according to the printing angle. A total of five patients undergoing the placement of a single crown on the mandibular molar were included. Interim crowns were fabricated directly in the oral cavity using the conventional method. A digital light processing 3D printer was then used to fabricate crowns with build angles of 0, 45, and 90 degrees. Therefore, four fabricated interim crowns were randomly delivered to the patients, and each was used for one week. Before and after use, the intaglio surfaces of the interim crowns were scanned using a 3D scanner. The volume changes before and after use were measured, and changes in the height of the occlusal surface were evaluated using the root mean square value. Data normality was verified by statistical analysis, and the wear volume in each group was evaluated using a one-way analysis of variance and Tukey's honestly significant difference test (α = 0.05). Compared with the RMS values of the conventional method (11.88 ± 2.69 µm) and the 3D-printing method at 0 degrees (12.14 ± 2.38 µm), the RMS values were significantly high at 90 degrees (16.46 ± 2.39 µm) (p < 0.05). Likewise, there was a significant difference in the change in volume between the groups (p = 0.002), with a significantly higher volume change value at 90 degrees (1.74 ± 0.41 mm3) than in the conventional method (0.70 ± 0.15 mm3) (p < 0.05). A printing angle of 90 degrees is not recommended when interim crowns are fabricated using digital light processing 3D printing.

9.
Obesity (Silver Spring) ; 30(10): 2079-2088, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36150209

RESUMO

OBJECTIVE: Along with rapid economic growth, the United Arab Emirates (UAE) has undergone enormous sociocultural changes. Consequently, sociocultural and psychological factors, along with malnutrition and physical inactivity, have contributed to the high obesity rate. The objective of this study is to assess the long-term impact of these new emerging factors on obesity among women in the UAE via mathematical modeling. METHODS: A differential equation model was developed considering psychological/social factors in population dynamics. It predicts the long-term prevalence of obesity among women in the UAE under these factors by 2070. Computer simulations and a sensitivity analysis of the model were conducted to measure the impact of these factors on obesity. RESULTS: The model predicts the following: 80.07% of female UAE nationals will become overweight or have obesity and 60.19% will have obesity by 2070, and the population with abnormal eating behavior will increase to 15% by 2070. Psychological/social factors aggravate the obesity problems and can cause abnormal eating behavior to develop with little effect on weight reduction. CONCLUSIONS: The obesity rate of female UAE nationals will continue to rise by 2070. Rising abnormal eating behavior caused by psychological/social factors is an emerging issue and should be recognized as a sign of escalating obesity problems in the UAE.


Assuntos
Obesidade , Interação Social , Feminino , Humanos , Obesidade/epidemiologia , Prevalência , Emirados Árabes Unidos/epidemiologia
10.
J Adv Prosthodont ; 14(2): 88-95, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35601352

RESUMO

PURPOSE: This study investigated the accuracy of full-arch intraoral scans obtained by various scan strategies with the segmental scan and merge methods. MATERIALS AND METHODS: Seventy intraoral scans (seven scans per group) were performed using 10 scan strategies that differed in the segmental scan (1, 2, or 3 segments) and the scanning motion (straight, zigzag, or combined). The three-dimensional (3D) geometric accuracy of scan images was evaluated by comparison with a reference image in an image analysis software program, in terms of the arch shape discrepancies. Measurement parameters were the intermolar distance, interpremolar distance, anteroposterior distance, and global surface deviation. One-way analysis of variance and Tukey honestly significance difference post hoc tests were carried out to compare differences among the scan strategy groups (α = .05). RESULTS: The linear discrepancy values of intraoral scans were not different among scan strategies performed with the single scan and segmental scan methods. In general, differences in the scan motion did not show different accuracies, except for the intermolar distance measured under the scan conditions of a 3-segmental scan and zigzag motion. The global surface deviations were not different among all scan strategies. CONCLUSION: The segmental scan and merge methods using two scan parts appear to be reliable as an alternative to the single scan method for full-arch intraoral scans. When three segmental scans are involved, the accuracy of complete arch scan can be negatively affected.

11.
Materials (Basel) ; 14(16)2021 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-34442986

RESUMO

The purpose of this study was to evaluate the bone-generating ability of a new bovine-derived xenograft (S1-XB) containing hydrogel. For control purposes, we used Bio-Oss and Bone-XB bovine-derived xenografts. S1-XB was produced by mixing Bone-XB and hydrogel. Cell proliferation and differentiation studies were performed to assess cytotoxicities and cell responses. For in vivo study, 8 mm-sized cranial defects were formed in 16 rats, and then the bone substitutes were transplanted into defect sites in the four study groups, that is, a Bio-Oss group, a Bone-XB group, an S1-XB group, and a control (all n = 4); in the control group defects were left empty. Eight weeks after surgery, new bone formation areas were measured histomorphometrically. In the cell study, extracts of Bio-Oss, Bone-XB, and S1-XB showed good results in terms of the osteogenic differentiation of human mesenchymal stem cells (hMSCs) and no cytotoxic reaction was evident. No significant difference was observed between mean new bone areas in the Bio-Oss (36.93 ± 4.27%), Bone-XB (35.07 ± 3.23%), and S1-XB (30.80 ± 6.41%) groups, but new bone area was significantly smaller in the control group (18.73 ± 5.59%) (p < 0.05). Bovine-derived bone graft material containing hydrogel (S1-XB) had a better cellular response and an osteogenic effect similar to Bio-Oss.

12.
Materials (Basel) ; 14(12)2021 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-34199187

RESUMO

This study aimed to compare two methods of crosslinking collagen type I on implanted titanium surfaces, that is, using glutaraldehyde (GA) or gamma-rays (GRs), in a beagle dog model. For in vivo experiments, implants were allocated to three groups and applied to mandibular bone defects in beagle dogs; Group SLA; non-treated Sandblasted, large grit, acid-etched (SLA) implants, Group GA; SLA implants coated with GA crosslinked collagen type I, Group GR; SLA surface implants coated with collagen type I and crosslinked using 25 kGy of 60Co gamma radiation. New bone µCT volumes were obtained, and histologic and histometric analyses were performed in regions of interest. The GR group had significantly better new bone areas (NBAs) and bone to implant contact (BIC) results than the SLA group (p < 0.05), but the GA and GR groups were similar in this respect. New bone volumes and inter-thread bone densities (ITBD) were non-significantly different in the three groups (p > 0.05). Within the limits of this study, gamma-ray collagen crosslinking on titanium implants can be considered a substitute for glutaraldehyde crosslinking.

13.
Phys Rev Lett ; 127(26): 267203, 2021 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-35029465

RESUMO

Topological magnonic materials have attracted much interest because of the potential for dissipationless spintronic applications. Pyrochlore iridates are theoretically regarded as good candidates for designing topological magnon bands. However, experimental identification of topological magnon bands in pyrochlore iridates remains elusive. We explored this possibility in Y_{2}Ir_{2}O_{7} using Raman spectroscopy to measure both the single-magnon excitations and anomalous phonon shifts. From the single-magnon energies and tight-binding model calculations concerning the phonons, we determined the key parameters in the spin Hamiltonian. These confirm that Y_{2}Ir_{2}O_{7} hosts a nontrivial magnon band topology distinct from other pyrochlore iridate compounds. Our work demonstrates that pyrochlore iridates constitute a system in which the magnon band topology can be tailored and that Raman spectroscopy is a powerful technique to explore magnon band topology.

14.
World J Mens Health ; 39(1): 48-64, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32202086

RESUMO

Currently, several treatments exist for the improvement of erectile dysfunction (ED). These include medical therapies such as phosphodiesterase type 5 inhibitors (PDE5-Is), invasive methods such as intracavernosal injection therapy of vaso-active substances, vacuum erection devices, and penile prosthesis implants. However, the percentage of patients that are unresponsive to available treatments and who drop out from treatments remains high. Current evidence reveals that the pathogenesis of ED is related to multiple factors including underlying comorbidities, previous surgery, and psychological factors. Diverse approaches using novel molecular pathways or new technologies have been tested as potential therapeutic options for difficultto-treat ED populations. Melanocortin receptor agonist, a centrally acting agent, showed promising results by initiating erection without sexual stimulation in non-responders to PDE5-Is. Recent clinical and pre-clinical studies using human tissues suggested that new peripherally acting agents including the Max-K channel activator, guanylate cyclase activator, and nitric oxide donor could be potential therapies either as a monotherapy or in combination with PDE5-Is in ED patients. According to several clinical trials, regeneration therapy using stem cells showed favorable data in men with diabetic or post-prostatectomy ED. Low-intensity shock wave therapy also demonstrated promising results in patients with vasculogenic ED. There are growing evidences which suggest the efficacy of these emerging therapies, though most of the therapies still need to be validated by well-designed clinical trials. It is expected that, should their long-term safety and efficacy be proven, the emerging treatments can meet the needs of patients hitherto unresponsive to or unsatisfied by current therapies for ED.

15.
Materials (Basel) ; 12(15)2019 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-31370160

RESUMO

It is important to obtain sufficient bone mass before implant placement on alveolar bone, and synthetic bone such as biphasic calcium phosphate (BCP) has been studied to secure this. This study used a BCP block bone with a specific structure of the three-dimensional (3D) hexahedron channel and coating with recombinant human bone morphogenetic protein-2 (rhBMP-2) impregnated carboxymethyl cellulose (CMC) was used to examine the enhancement of bone regeneration of this biomaterial in rat calvarial defect. After the preparation of critical-size calvarial defects in fifteen rats, defects were divided into three groups and were implanted with the assigned specimen (n = 5): Boneplant (untreated 3D hexahedron channeled BCP block), Boneplant/CMC (3D hexahedron channeled BCP block coated with CMC), and Boneplant/CMC/BMP (3D hexahedron channeled BCP block coated with CMC containing rhBMP-2). After 4 weeks, the volumetric, histologic, and histometric analyses were conducted to measure the newly formed bone. Histologically, defects in the Boneplant/CMC/BMP group were almost completely filled with new bone compared to the Boneplant and Boneplant/CMC groups. The new bone volume (P < 0.05) and area (P < 0.001) in the Boneplant/CMC/BMP group (20.12% ± 2.17, 33.79% ± 3.66) were much greater than those in the Boneplant (10.77% ± 4.8, 16.48% ± 9.11) and Boneplant/CMC (10.72% ± 3.29, 16.57% ± 8.94) groups, respectively. In conclusion, the 3D hexahedron channeled BCP block adapted rhBMP-2 with carrier CMC showed high possibility as an effective bone graft material.

16.
J Exerc Rehabil ; 15(1): 15-19, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30899730

RESUMO

This study examined differences of physical activity levels and social interactions among preschoolers with/without disabilities and those at risk for a developmental delay (DD). Sixty preschoolers (20 in each group) were film during their designated large gross motor time. Their physical activity levels and social interaction were examined using the physical activity level screening. Regarding physical activity levels, the result of a two-way analysis of variance indicated significant main effects for groups, F(2,54)=4.192, P=0.02; preschoolers at risk for a DD were more active than preschoolers without disabilities, P=0.02. For social interaction, a significant main effect for groups, F(2,54)=8.994, P<0.001 was found; Preschoolers at risk for a DD were more interactive than preschoolers with/without disabilities, P=0.001 and P=0.002, respectively. There were no significant gender differences across three groups on physical activity levels and social interactions. Although preschoolers at risk for a DD was more active and interactive than the other groups, preschoolers across three groups engaged in light physical activity levels, and had limited social interactions with peers.

17.
Adv Healthc Mater ; 7(9): e1700985, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29460365

RESUMO

A capsule-type microrobot exhibits "pick-and-drop" (P&D) motion to hold a particle within a confined volume and transports it via a corkscrewing motion. The P&D motion is possible because the capsule-type microrobot has two parts: a plunger and a cap. The fabricated microrobots are wirelessly controlled by a magnetic manipulator. Drugs or cells can be encapsulated in the container of the capsule-type microrobot by the P&D motion or attached to the surface of the cap, which can be used as a supporting structure. Therefore, the capsule-type microrobot can deliver suspended or adherent cells. The drug or cells are minimally exposed or not completely exposed to the surrounding fluid and do not experience shear force when encapsulated in the container. As a proof-of-concept, secure transportation of microparticles in the confined volume of the capsule via P&D motion is demonstrated. In addition, the cap is used as a scaffold for neuronal cell culture on a rat brain slice to demonstrate its biocompatibility and feasibility for targeted cell delivery. The proposed capsule-type microrobot is suitable for diverse applications, as it protects the encapsulated materials.


Assuntos
Transplante de Células , Sistemas de Liberação de Medicamentos , Robótica , Animais , Cápsulas , Transplante de Células/instrumentação , Transplante de Células/métodos , Sistemas de Liberação de Medicamentos/instrumentação , Sistemas de Liberação de Medicamentos/métodos , Masculino , Ratos , Ratos Sprague-Dawley , Robótica/instrumentação , Robótica/métodos
18.
J Adv Prosthodont ; 9(4): 244-251, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28874990

RESUMO

PURPOSE: The purpose of this study was to determine fracture resistance and failure modes of three-unit fixed dental prostheses (FDPs) made of lithium disilicate pressed on zirconia (LZ), monolithic lithium disilicate (ML), and monolithic zirconia (MZ). MATERIALS AND METHODS: Co-Cr alloy three-unit metal FDPs model with maxillary first premolar and first molar abutments was fabricated. Three different FDPs groups, LZ, ML, and MZ, were prepared (n = 5 per group). The three-unit FDPs designs were identical for all specimens and cemented with resin cement on the prepared metal model. The region of pontic in FDPs was given 50,000 times of cyclic preloading at 2 Hz via dental chewing simulator and received a static load until fracture with universal testing machine fixed at 10°. The fracture resistance and mode of failure were recorded. Statistical analyses were performed using the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni's correction (α=0.05/3=0.017). RESULTS: A significant difference in fracture resistance was found between LZ (4943.87 ± 1243.70 N) and ML (2872.61 ± 658.78 N) groups, as well as between ML and MZ (4948.02 ± 974.51 N) groups (P<.05), but no significant difference was found between LZ and MZ groups (P>.05). With regard to fracture pattern, there were three cases of veneer chipping and two interfacial fractures in LZ group, and complete fracture was observed in all the specimens of ML and MZ groups. CONCLUSION: Compared to monolithic lithium disilicate FDPs, monolithic zirconia FDPs and lithium disilicate glass ceramics pressed on zirconia-based FDPs showed superior fracture resistance while they manifested comparable fracture resistances.

19.
Materials (Basel) ; 10(1)2017 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-28772381

RESUMO

In this study, bisphasic calcium phosphate (BCP) and two types of polysaccharide, carboxymethyl cellulose (CMC) and hyaluronic acid (HyA), were used to fabricate composite block bone grafts, and their physical and biological features and performances were compared and evaluated in vitro and in vivo. Specimens of the following were prepared as 6 mm diameter, 2 mm thick discs; BPC mixed with CMC (the BCP/CMC group), BCP mixed with crosslinked CMC (the BCP/c-CMC group) and BCP mixed with HyA (the BCP/HyA group) and a control group (specimens were prepared using particle type BCP). A scanning electron microscope study, a compressive strength analysis, and a cytotoxicity assessment were conducted. Graft materials were implanted in each of four circular defects of 6 mm diameter in calvarial bone in seven rabbits. Animals were sacrificed after four weeks for micro-CT and histomorphometric analyses, and the findings obtained were used to calculate new bone volumes (mm³) and area percentages (%). It was found that these two values were significantly higher in the BCP/c-CMC group than in the other three groups (p < 0.05). Within the limitations of this study, BCP composite block bone graft material incorporating crosslinked CMC has potential utility when bone augmentation is needed.

20.
J Exerc Rehabil ; 13(2): 210-213, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28503535

RESUMO

Psychometric properties of the physical activity level screening (PALS) for preschoolers with a developmental delay and/or a disability were examined in this study. The mean age of participants (16 boys and 14 girls) was 54.9 months (standard deviation, 10.4). Each participant wore one Actical accelerometer and was filmed for 20 min during the active play time. Intrarater and interrater reliability, and validity of the PALS data were examined. The proportion of agreement for intrarater was 87.5% and 85.6% for interrater reliability. Intraclass correlation coefficients were 0.99 for intrarater and 0.96 for interrater. The PALS data showed moderate correlation with Actical data (r=0.67, P<0.01).