Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Exerc Rehabil ; 13(4): 413-417, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29114506

RESUMO

This study investigated the correlation between the neck disability index (NDI) and visual analogue scale (VAS), which are indicators of neck pain, shoulder joint range of motion (ROM), and muscle strength in women with a slight forward head posture. This study was carried out on 42 female college students attending Uiduk University in Gyeongju, Korea. The neck pain and disability index for each subject was measured using VAS and NDI, respectively. Two physiotherapists measured the shoulder joint ROM and muscle strengths of the subjects using a goniometer and a dynamometer, respectively. External rotation, internal rotation, and abduction of the shoulder joint were measured for each subject. A significant negative correlation between neck pain and shoulder joint ROM in external rotation and the muscle strength of the shoulder joint in abduction was found in the subjects. In addition, a significant positive correlation was observed between ROM in external rotation and muscle strength in abduction. This study showed a significant negative correlation between neck pain and ROM in external rotation as well as between neck pain and the muscle strength in abduction.

2.
J Phys Ther Sci ; 29(4): 775-778, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28533629

RESUMO

[Purpose] This study aimed to investigate the effects of multisensory dynamic balance training on muscles thickness such as rectus femoris, anterior tibialis, medial gastrocnemius, lateral gastrocnemius in children with spastic diplegic cerebral palsy by using ultrasonography. [Subjects and Methods] Fifteen children diagnosed with spastic diplegic cerebral palsy were divided randomly into the balance training group and control group. The experimental group only received a multisensory dynamic balance training, while the control group performed general physiotherapy focused balance and muscle strengthening exercise based Neurodevelopmental treatment. Both groups had a therapy session for 30 minutes per day, three times a week for six weeks. The ultrasonographic muscle thickness were obtained in order to compare and analyze muscle thickness before and after in each group. [Result] The experimental group had significant increases in muscle thickness in the rectus femoris, tibialis anterior, medial gastrocnemius and lateral gastrocnemius muscles. The control group had significant increases in muscle thickness in the tibialis anterior. The test results of the rectus femoris, medial gastrocnemius and lateral gastrocnemius muscle thickness values between the groups showed significant differences. [Conclusion] In conclusion, a multisensory dynamic balance training can be recommended as a treatment method for patients with spastic diplegic cerebral palsy.

3.
J Phys Ther Sci ; 28(5): 1569-73, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27313373

RESUMO

[Purpose] This study investigated the effects of forward and backward walking using different treadmill incline positions on lower muscle activity in children with cerebral palsy, to provide baseline data for gait training intensity. [Subjects and Methods] Nineteen subjects with cerebral palsy walked forward and backward at a self-selected pace on a treadmill with inclines of 0%, 5%, 10%, and 15%. Activation of the rectus femoris, biceps femoris, tibialisanterior, and lateral gastrocnemius was measured using surface electromyography during the stance phase. [Results] As treadmill incline increased during forward walking, muscle activation of the paralyzed lower limbs did not significantly change. However, as treadmill incline increased during backward walking, rectus femoris activation significantly increased and a significant difference was found between treadmill inclines of 0% and 10%. A comparison of backward and forward walking showed a significant difference in rectus femoris activation at treadmill inclines of 0%, 5%, and 10%. Activation of the tibialis anterior was only significantly higher for backward walking at the 10% gradient. [Conclusion] Backward walking may strengthen the rectus femoris and tibialis anterior in walking training for cerebral palsy. Gradient adjustment of the treadmill can be used to select the intensity of walking training.

4.
J Phys Ther Sci ; 28(5): 1611-3, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27313383

RESUMO

[Purpose] The purpose of this study was to examine the correlation between lower extremity muscle thickness and gait ability through the 10-meter walk and timed up and go tests. [Subjects and Methods] A total of 28 children (20 males and 8 females) with spastic cerebral palsy undergoing physical therapy at D hospital in D city, South Korea participated in this study. Partial correlation analysis was performed to analyze the correlation between lower extremity muscle thickness and gait ability (10-meter walk test and timed up and go test). [Results] There was a positive correlation between muscle thickness and the 10-meter walk test (RF=0.41 and VL=0.52). Correlation between the muscle thickness and the timed up and go had a negative correlation (VL=-0.45, MG=-0.51, and LG=-0.39). [Conclusion] In children with cerebral palsy, knee extensor muscles that are more developed increased gait ability and calf muscles that are more developed increased sit to stand ability.

5.
Int J Nanomedicine ; 3(1): 117-24, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18488422

RESUMO

A silicon nanowire-based sensor for biological application showed highly desirable electrical responses to either pH changes or receptor-ligand interactions such as protein disease markers, viruses, and DNA hybridization. Furthermore, because the silicon nanowire can display results in real-time, it may possess superior characteristics for biosensing than those demonstrated in previously studied methods. However, despite its promising potential and advantages, certain process-related limitations of the device, due to its size and material characteristics, need to be addressed. In this article, we suggest possible solutions. We fabricated silicon nanowire using a top-down and low cost micromachining method, and evaluate the sensing of molecules after transfer and surface modifications. Our newly designed method can be used to attach highly ordered nanowires to various substrates, to form a nanowire array device, which needs to follow a series of repetitive steps in conventional fabrication technology based on a vapor-liquid-solid (VLS) method. For evaluation, we demonstrated that our newly fabricated silicon nanowire arrays could detect pH changes as well as streptavidin-biotin binding events. As well as the initial proof-of-principle studies, C-reactive protein binding was measured: electrical signals were changed in a linear fashion with the concentration (1 fM to 1 nM) in PBS containing 1.37 mM of salts. Finally, to address the effects of Debye length, silicon nanowires coupled with antigen proteins underwent electrical signal changes as the salt concentration changed.


Assuntos
Técnicas Biossensoriais/instrumentação , Proteína C-Reativa/análise , Eletroquímica/instrumentação , Microeletrodos , Nanotecnologia/instrumentação , Nanotubos/química , Técnicas Biossensoriais/métodos , Eletroquímica/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Nanotecnologia/métodos , Nanotubos/ultraestrutura , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Small ; 4(5): 642-8, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18431721

RESUMO

A method to fabricate suspended silicon nanowires that are applicable to electronic and electromechanical nanowire devices is reported. The method allows for the wafer-level production of suspended silicon nanowires using anisotropic etching and thermal oxidation of single-crystal silicon. The deviation in width of the silicon nanowire bridges produced using the proposed method is evaluated. The NW field-effect transistor (FET) properties of the device obtained by transferring suspended nanowires are shown to be practical for useful functions.


Assuntos
Cristalização/métodos , Nanotecnologia/instrumentação , Nanotubos/química , Silício/química , Transistores Eletrônicos , Desenho de Equipamento , Análise de Falha de Equipamento , Substâncias Macromoleculares/química , Teste de Materiais , Conformação Molecular , Nanotecnologia/métodos , Nanotubos/ultraestrutura , Tamanho da Partícula , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA