Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 117(44): 27245-27254, 2020 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-33097668

RESUMO

We use neutron scattering to show that ferromagnetism and antiferromagnetism coexist in the low T state of the pyrochlore quantum magnet [Formula: see text] While magnetic Bragg peaks evidence long-range static ferromagnetic order, inelastic scattering shows that short-range correlated antiferromagnetism is also present. Small-angle neutron scattering provides direct evidence for mesoscale magnetic structure that we associate with metastable antiferromagnetism. Classical Monte Carlo simulations based on exchange interactions inferred from [Formula: see text]-oriented high-field spin wave measurements confirm that antiferromagnetism is metastable within the otherwise ferromagnetic ground state. The apparent lack of coherent spin wave excitations and strong sensitivity to quenched disorder characterizing [Formula: see text] is a consequence of this multiphase magnetism.

2.
Rev Sci Instrum ; 87(12): 125110, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28040941

RESUMO

We report on the design, construction, and performance of a neutron resonance spin echo (NRSE) instrument employing radio frequency (RF) spin flippers combining RF fields with DC fields, the latter oriented parallel (longitudinal) to the neutron propagation direction (longitudinal NRSE (LNRSE)). The advantage of the longitudinal configuration is the inherent homogeneity of the effective magnetic path integrals. In the center of the RF coils, the sign of the spin precession phase is inverted by a π flip of the neutron spins, such that non-uniform spin precession at the boundaries of the RF flippers is canceled. The residual inhomogeneity can be reduced by Fresnel- or Pythagoras-coils as in the case of conventional spin echo instruments (neutron spin echo (NSE)). Due to the good intrinsic homogeneity of the B0 coils, the current densities required for the correction coils are at least a factor of three less than in conventional NSE. As the precision and the current density of the correction coils are the limiting factors for the resolution of both NSE and LNRSE, the latter has the intrinsic potential to surpass the energy resolution of present NSE instruments. Our prototype LNRSE spectrometer described here was implemented at the resonance spin echo for diverse applications (RESEDA) beamline at the MLZ in Garching, Germany. The DC fields are generated by B0 coils, based on resistive split-pair solenoids with an active shielding for low stray fields along the beam path. One pair of RF flippers at a distance of 2 m generates a field integral of ∼0.5 Tm. The LNRSE technique is a future alternative for high-resolution spectroscopy of quasi-elastic excitations. In addition, it also incorporates the MIEZE technique, which allows to achieve spin echo resolution for spin depolarizing samples and sample environments. Here we present the results of numerical optimization of the coil geometry and first data from the prototype instrument.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA