Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
J Vasc Surg Cases Innov Tech ; 10(3): 101482, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38633580

RESUMO

In recent years, deep venous stenting has increasingly become a treatment strategy for post-thrombotic syndrome. Stent thrombosis can occur, resulting in symptom recurrence despite medical therapy, and there are few options available for durable stent patency restoration. We present a case of a 50-year-old male with prior iliocaval reconstruction that experienced recurrent left lower extremity swelling secondary to occlusion of left external iliac and common iliac vein stents during follow-up. Mechanical thrombectomy with the RevCore System and angioplasty was performed. One month later, the patient demonstrated widely patent bilateral iliac vein stents and complete symptomatic resolution. The RevCore System is a feasible alternative for treatment of chronic in-stent thrombosis.

2.
J Vasc Surg ; 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38570175

RESUMO

OBJECTIVE: Radiation-induced carotid artery stenosis (RICS) is a well-described phenomenon seen after head and neck cancer radiation. Previously published literature suggests that, compared with atherosclerotic disease, RICS may result in worse long-term outcomes and early restenosis. This study aims to evaluate the effect of radiation on long-term outcomes after various carotid revascularization techniques using a multi-center registry database. METHODS: Patients in the Society for Vascular Surgery (SVS) Vascular Quality Initiative (VQI) registry for carotid artery intervention (carotid endarterectomy [CEA]; transfemoral carotid artery stenting [CAS]; transcarotid artery revascularization [TCAR]), who are 65 years or older were included in the study. VQI Vascular Implant Surveillance and Interventional Outcomes Network (VISION) Medicare-linked database was used to obtain long-term procedure-specific outcomes. Primary endpoints were 3-year death, stroke, and reintervention. We performed propensity matching between patients with prior radiation and those without. Kaplan-Meier analysis and a multivariate logistic regression model were used to analyze the outcome variables. RESULTS: A total of 56,472 patients had undergone carotid revascularization (CEA, n = 48,307; TCAR, n = 4593; CAS, n = 3572), 1244 patients with prior radiation and 54,925 patients without prior radiation. The prior radiation group was more likely to be male (71.9% vs 60.3%; P < .01), to receive a stent (47.5% vs 13.5%; P < .01), and to be on P2Y12 inhibitor (55.2% vs 38.3%; P < .01). Propensity matching was performed on 1223 patients (CEA, n = 655; TCAR, n = 292; CAS, n = 287). There were no significant differences in 30-day outcomes for death, stroke, or major adverse cardiovascular events for all three procedures. The prior radiation group had higher rates of cranial nerve injury (3.7% vs 1.8%; P = .04) and 90-day readmission (23.5% vs 18.3%; P = .01) after CEA. For long-term outcomes, prior radiation significantly increased mortality risk for CEA and CAS (hazard ratio [HR], 1.77; 95% confidence interval [CI], 1.38-2.27 and HR, 1.56; 95% CI, 1.02-2.36, respectively). The 3-year risk of stroke for CEA in radiated patients was also significantly higher (HR, 1.47; 95% CI, 1.03-2.09) compared with non-radiated patients. Prior radiation did not significantly affect death and stroke in patients undergoing TCAR. Prior radiation also did not impact the rates of short and long-term reintervention after CEA, CAS, or TCAR. CONCLUSIONS: Prior head and neck radiation significantly increases the risk for mortality and stroke for CEA and the risk for mortality after CAS. Long-term outcomes for TCAR are not significantly affected by prior radiation. TCAR may be the preferred treatment modality for patients with radiation-induced carotid stenosis.

3.
J Vasc Surg Cases Innov Tech ; 10(3): 101431, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38510086

RESUMO

Inferior vena cava (IVC) atresia is a rare congenital anomaly. Standardized treatment is not well defined due to its uncommon presentation, with this pathology associated with an increased risk of unprovoked lower extremity deep vein thrombosis (DVT). We present a case of a 32-year-old man who was admitted for bilateral lower extremity edema and pain and was found to have bilateral extensive iliofemoral and femoropopliteal DVT, absence of IVC filling, and extensive tortuous collateralization arising from the pelvic veins to the azygos vein. Bilateral mechanical thrombectomy and endovascular iliocaval reconstruction was performed. Three months later, the patient demonstrated widely patent iliocaval stents and the absence of DVT. Endovascular treatment of IVC atresia is feasible and optimizes the reduction of thrombus burden.

4.
J Vasc Surg ; 79(1): 102-110, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37704092

RESUMO

OBJECTIVE: Superficial femoral artery (SFA) stenting is a common treatment for peripheral artery disease. It is effective in the short term; however, in-stent restenosis (ISR) limits long-term success. Surveillance with duplex ultrasound (DUS) can identify patients who develop ISR leading to early reintervention, but data to support this practice is sparce. The purpose of this study was to evaluate whether surveillance and subsequent reintervention improves outcomes in patients with SFA stents. METHODS: A single-center, retrospective study was performed with patients undergoing SFA stenting between 2005 and 2020 who had a follow-up with DUS. Five groups were identified based on the presence of ISR on DUS (ISR vs no ISR [NISR]), recurrence of symptoms (symptomatic [SX] vs asymptomatic [ASX]), and if any reintervention was performed (reintervention [R] vs no reintervention [NR]): (1) ISR+SX+R; (2) ISR+SX+NR; (3) ISR+ASX+R; (4) ISR+ASX+NR; and (5) NISR+NR. The primary endpoint was amputation-free survival, and the secondary endpoint was patency. Predictors of mortality and surveillance were identified by multivariable logistic regressions and Cox multivariate regression models. Survival curves were presented as Kaplan-Meier plots using log-rank test for subgroup comparison. RESULTS: Two hundred fifty-seven patients were included in the analysis. The indication for intervention was claudication in 28% and chronic limb-threatening ischemia in 72%. A total of 161 patients (63%) underwent reintervention for ISR. Of patients who had restenosis on DUS, those who were symptomatic and did not undergo reintervention (ISR+SX+NR) did the worst, with 50% amputation rate. In contrast, those who were asymptomatic but did undergo reintervention (ISR+ASX+R) had the lowest amputation rate of 13%. Active smoking was a predictor of both loss of patency and amputation (1.72; 95% confidence interval [CI], 1.00-2.98; P = .050; 3.55; 95% CI, 1.53-8.25; P = .003). Post procedure dual antiplatelet therapy had a positive association with limb salvage (hazard ratio [HR], 0.23; 95% CI, 0.09-0.58; P = .001), whereas diabetes (HR, 2.61; 95% CI, 1.21-6.01; P = .019), stent occlusion (HR, 17.0; 95% CI, 5.93-63.1; P < .001), and chronic limb-threatening ischemia presentations (HR, 4.31; 95% CI, 1.86-11.7; P=.002) were negatively associated with limb salvage. CONCLUSIONS: Routine surveillance DUS and subsequent reintervention on ISR after SFA stenting is associated with improved patency and amputation-free survival. Surveillance DUS should be routine for patients after stenting, with reintervention strongly considered if ISR is identified for both symptomatic and asymptomatic.


Assuntos
Artéria Femoral , Doença Arterial Periférica , Humanos , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Isquemia Crônica Crítica de Membro , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Risco , Grau de Desobstrução Vascular , Stents , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Constrição Patológica
5.
J Vasc Surg ; 79(4): 948-953, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38040201

RESUMO

OBJECTIVE: Breast cancer most commonly occurs in the upper outer quadrant (UOQ) chest wall (CW). The effectiveness of routine leaded aprons to protect this region of the body in interventionalists during fluoroscopically guided interventions (FGIs) is unknown. Given the high lifetime attributable risks of prolonged occupational exposure to ionizing radiation and the increasing number of practicing female vascular surgeons and interventionalists, we sought to determine if the use of a leaded arm shield would offer additional protection to the lateral CW and axilla in operators compared with routine leaded aprons. METHODS: Effectiveness of leaded sleeves in attenuating radiation dose to the axilla and UOQ was evaluated in clinical practice and simulated scenarios. In the clinical setting, optically stimulated luminescence nanoDot detectors were placed at the UOQ lateral CW position, both over and under a standard leaded apron vest with and without the addition of an antimony/bismuth Enviro-Lite sleeve on two vascular surgeons performing FGIs. In the simulation, nanoDots were similarly placed on an anthropomorphic phantom positioned to represent a primary operator performing right femoral access. Fluorography was performed on 12-inch-thick acrylic scatter phantom at 80 kVp for an exposure of 3 Gy reference air kerma. Experiments were done with and without the sleeve. Paired Wilcoxon and χ2 tests were performed to identify the statistical significance of radiation attenuation. RESULTS: Operator UOQ CW dose was measured during 61 FGIs: 33 cases (54%) with and 28 cases (46%) without the sleeve. Median procedure reference air kerma and fluoroscopy time was 180 mGy (interquartile range [IQR], 85-447 mGy) and 21 minutes (IQR, 11-39 minutes) when the sleeve was worn vs 100 mGy (IQR, 67-270 mGy) and 11 minutes (IQR, 6.3-25 minutes) without the sleeve. Radiation dose to the operator's UOQ was reduced by 96% (IQR, 85%-96%) when the sleeve was present and by 62% (IQR, 44%-82%; P < .001) without the sleeve. In the simulated setting, the sleeve reduced the radiation dose to the UOQ compared with the apron alone (96% vs 67%; P < .001). CONCLUSIONS: Routine leaded aprons do attenuate the majority of UOQ chest wall radiation dose; however, the addition of a lead-equivalent sleeve further significantly reduces this dose. Because this area of the body has a high incidence of cancer formation, additional protection, especially to female interventionalists, seems prudent. Vascular surgeons should consider using a protective sleeve with their personal protective equipment when performing complex fluoroscopically guided procedures.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Parede Torácica , Humanos , Feminino , Doses de Radiação , Braço , Roupa de Proteção , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/prevenção & controle , Fluoroscopia , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/efeitos adversos
6.
J Vasc Surg ; 79(5): 1034-1043, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38157993

RESUMO

OBJECTIVE: Chronic kidney disease (CKD) and end-stage renal disease are traditionally associated with worse outcomes after endovascular aortic repair (EVAR) and open aneurysm repair (OAR) of abdominal aortic aneurysms (AAAs). However, there needs to be more data on complex AAA repair involving the aorta's visceral segment. This study stratifies complex AAA repair outcomes by CKD severity and dialysis dependence. METHODS: All patients undergoing elective OAR and fenestrated/branched EVAR (F-BEVAR) for complex AAA with preoperative renal function data captured by the Vascular Quality Initiative between January 2003 and September 2020 were analyzed. Patients were stratified by CKD class as follows: normal/mild (CKD 1 and 2), moderate (CKD class 3a), moderate to severe (CKD 3b), severe (CKD class 4 and 5), and dialysis. Only patients with clamp sites above one of the renal arteries were included for complex OAR. For F-BEVAR, patients with proximal landing zones below zone 5 (above celiac artery) were included, and distal landing zones between zones 1 and 5 were excluded. Primary outcomes were perioperative and 1-year mortality. Predictors of mortality were identified by Cox multivariate regression models. RESULTS: We identified 7849 elective complex AAA repairs: 4230 (54%) complex OARs and 3619 (46%) F-BEVARs. Most patients were White (89%) and male (74%), with an average age of 72 ± 8 years. The patients who underwent F-BEVAR were older and had more comorbidities. Elective F-BEVAR for complex AAA started in 2012 and increased from 1.4% in 2012 to 58% in 2020 (P < .001). The OAR cohort had more perioperative complications, but less 1-year mortality. The normal/mild CKD cohort had the highest 1-year survival compared with other groups after both complex OAR and F-BEVAR. On Cox regression analysis, when compared with CKD 1-2, worsening CKD stage (CKD 3b: hazard ratio [HR], 2.5; 95% confidence interval [CI], 1.82-3.40; P < .001; CKD 4-5: HR, 1.9; 95% CI, 1.16-3.26; P = .011; and dialysis: HR, 4.4; 95% CI, 2.53-7.72; P < .001) were independently associated with 1-year survival after F-BEVAR. After complex OAR, worsening CKD stage but not dialysis was associated with 1-year mortality compared with CKD 1-2 (CKD 3b: HR, 1.6; 95% CI, 1.13-2.35; P = .009; CKD 4-5: HR, 3.4; 95% CI, 2.03-5.79; P < .001). CONCLUSIONS: CKD severity is an essential predictor of perioperative and 1-year mortality after complex AAA repair, irrespective of the treatment modality, which may reflect the natural history of CKD. Consideration should be given to raising the threshold for elective AAA repair in patients with moderate to severe CKD and end-stage renal disease, given the high 1-year mortality rate.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Falência Renal Crônica , Insuficiência Renal Crônica , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Fatores de Risco , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Fatores de Tempo , Falência Renal Crônica/complicações , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/terapia , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/terapia , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Estudos Retrospectivos
7.
JMIR Res Protoc ; 12: e51480, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38048145

RESUMO

BACKGROUND: The recommendations for the use of and selection of covered stent grafts in patients with aortoiliac occlusive disease are limited. OBJECTIVE: The GORE VBX FORWARD clinical study aims to demonstrate the superiority of the GORE VIABAHN VBX Balloon Expandable Endoprosthesis (VBX device) for primary patency when compared to bare metal stenting (BMS) for the treatment of complex iliac artery occlusive disease. METHODS: A prospective, multicenter, randomized control study in the United States, European Union, United Kingdom, Australia, and New Zealand will enroll patients with symptomatic, complex iliac artery occlusive disease. In this study, iliac artery occlusive disease is defined as a unilateral or bilateral disease with single or multiple lesions (with >50% stenosis or chronic total occlusion) each between 4 and 11 cm in length. In an attempt to more closely match real-world practices, patients with minor tissue loss (Rutherford class 5) and patients requiring hemodialysis will be included. Baseline aortoiliac angiography will be performed to assess target lesion characteristics and determine final patient eligibility. Once the patient is confirmed and guidewires are in place across the target lesions, the patient will be randomized in a 1:1 format to treatment with either the VBX device or a BMS. The BMS can be balloon- or self-expanding and must be approved for the iliac artery occlusive disease indication. Patients, the independent core laboratory reviewers, and Clinical Events Committee members will be blinded from the assigned treatment. Dual antithrombotic medical therapy is required through a minimum of 3 months post procedure. The primary end point is 12­month primary patency and will be adjudicated by an independent imaging core laboratory and Clinical Events Committee. Key secondary end points will be tested for superiority and include technical, acute procedural, and clinical success; changes in Ankle-brachial index; patient quality of life; primary patency; freedom from restenosis; primary-assisted patency; secondary patency; freedom from target lesion revascularizations; cumulative reintervention rate; amputation-free survival; survival; and change in Rutherford category. Study follow-up will continue through 5 years. RESULTS: Outcomes will be reported following study completion. Enrollment is anticipated to start in October 2023. CONCLUSIONS: The results of this study will provide definitive, level 1 clinical evidence to clinicians on the optimal choice of stent device to use for the treatment of complex iliac artery occlusive disease. The FORWARD study is powered for superiority and includes only complex, unilateral, or bilateral lesions involving the common or external iliac arteries. This study is a multidisciplinary endeavor involving vascular surgery, interventional cardiology, and interventional radiology across multiple countries with a blinded core laboratory review of end points in hopes that the outcomes will be widely accepted and incorporated into practice guidelines for optimal treatment of patients with complex iliac artery occlusive disease. TRIAL REGISTRATION: ClinicalTrials.gov NCT05811364; https://clinicaltrials.gov/study/NCT05811364. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): PRR1-10.2196/51480.

8.
J Vasc Surg Cases Innov Tech ; 9(3): 101227, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37799846

RESUMO

Superior mesenteric artery aneurysms are rare and associated with high mortality rates in cases of rupture. Current Society for Vascular Surgery guidelines recommend treatment of all superior mesenteric artery aneurysms regardless of size. A 53-year-old woman who was admitted for abdominal pain was found with a 14-cm, ruptured superior mesenteric artery branch aneurysm. Endovascular approach was performed with microvascular plug embolization of a feeding branch and aneurysm sac exclusion with a stent graft. Four months later, the patient demonstrated a 21% regression of the aneurysm and stent patency. Thus, timely diagnosis and treatment of superior mesenteric artery aneurysms with endovascular techniques can reduce potential complications.

9.
Vasc Endovascular Surg ; 57(8): 954-959, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37310394

RESUMO

BACKGROUND: Kommerell's diverticulum (KD) with a right aortic arch (RAA) and aberrant left subclavian artery (aLSCA) is a rare congenital anomaly of the aortic arch. Treatment is not well defined due to its uncommon presentation, with rupture and dissection risk rates of up to 53%. CASE SUMMARY: A 54-year-old male with a history of chronic obstructive pulmonary disease (COPD) and hypertension presented with difficulty breathing during exercise without dysphagia. Follow-up computerized tomography angiogram (CTA) revealed the presence of a RAA and aLSCA arising from the descending thoracic aorta with an adjacent 58 × 41-mm KD and tracheal and esophageal displacement. Due to the size of the KD, risk of rupture, unsuitable anatomy for total endovascular aortic repair (EVAR), and high COPD burden, the patient was planned to undergo a hybrid surgical repair. Left common carotid (LCCA) artery to LSCA bypass, full aortic debranching, LSCA embolization and percutaneous thoracic endovascular aortic repair (TEVAR) were performed. Successful device position and exclusion of the diverticulum and aneurysmal aorta were observed after completion thoracic aortogram. 18-month follow-up CTA demonstrated patency of the LSCA to LCCA bypass graft and arch vessel branches, as well as stable exclusion of the KD. Persistence of a type II endoleak originated at the right first posterior intercostal artery has been noted and is being followed conservatively since no sac growth has occurred. CONCLUSION: We highlight the presence of a KD with RAA and aberrant subclavian artery, a rare congenital anatomic variation of the aortic arch with complex anatomy. Surgical planning must be individualized according to comorbidities and anatomical variations identified on imaging and 3D reconstructions.


Assuntos
Anormalidades Cardiovasculares , Divertículo , Doença Pulmonar Obstrutiva Crônica , Masculino , Humanos , Pessoa de Meia-Idade , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aorta Torácica/anormalidades , Resultado do Tratamento , Anormalidades Cardiovasculares/complicações , Anormalidades Cardiovasculares/diagnóstico por imagem , Anormalidades Cardiovasculares/cirurgia , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/cirurgia , Artéria Subclávia/anormalidades , Aortografia/métodos , Divertículo/diagnóstico por imagem , Divertículo/cirurgia
10.
J Vasc Surg Cases Innov Tech ; 9(2): 101140, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37125341

RESUMO

Endovascular treatment options for vascular injury in pediatric patients are quite limited owing to concerns regarding long-term durability and the lack of devices suitable for the pediatric anatomy. However, in rare circumstances, open surgical therapy will not be an option, and patients will require unconventional endovascular solutions for lifesaving or limb-saving therapies. In the present report, we describe an endovascular treatment of a pediatric patient for whom initial surgical management of a blunt abdominal aortic injury had failed, with subsequent development of an aortic pseudoaneurysm. A 10-year-old girl had presented after a high-speed motor vehicle accident with a seatbelt sign. Multiple abdominal injuries were identified, including blunt aortic injury, significant devitalization of the small bowel, colonic perforation with fecal contamination, multiple lumbar spine fractures, and pulmonary contusions. The patient developed bilateral lower extremity ischemia from the aortic injury and had initially undergone open repair. One month later, the patient had developed a pseudoaneurysm of the aorta near the aortic bifurcation. Because of the hostile abdomen and ensuing short gut syndrome, the pseudoaneurysm was managed using endovascular techniques. The limb of an Excluder internal iliac branch endoprosthesis (W.L. Gore & Associates, Flagstaff, AZ) was used as the endograft. The aortic bifurcation was raised and reconstructed using four Viabahn self-expanding stents (W.L. Gore & Associates). The completion angiogram showed complete resolution of the pseudoaneurysm. The follow-up computed tomography angiogram showed widely patent stent grafts with complete resolution of the pseudoaneurysm. Endovascular management of traumatic vascular injuries in pediatric patients is feasible. The likelihood of reintervention in the future is high with patient growth. However, it is a viable option in lifesaving or limb-saving situations in which open repair is high risk.

11.
J Vasc Surg ; 77(3): 829-835, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36400362

RESUMO

OBJECTIVE: Fibromuscular dysplasia (FMD) is a noninflammatory arterial disease that affects the extracranial carotid arteries in young patients. The ideal treatment of FMD has continued to be debated, and the role of carotid artery stenting (CAS) is controversial. The aim of the present study was to assess the feasibility and outcomes of CAS for patients with FMD. METHODS: A retrospective analysis of patients who had undergone CAS was performed using the Vascular Quality Initiative database from December 2012 to May 2021. Patients who had undergone CAS for atherosclerosis and FMD were included and matched 1:1 by age, gender, and clinical presentation. The demographics, clinical parameters, and procedural data were analyzed. The end points included postoperative stroke and transient ischemic attack (TIA), and adverse events (perioperative and 1-year mortality, neurologic changes, access site complications, hematoma or bleeding, infection, congestive heart failure, arrhythmia, myocardial infarction, reperfusion symptoms), and hospital length of stay. RESULTS: After matching, 55 patients had undergone CAS for FMD (mean age, 58.7 ± 14 years; 62% women; 69% White; mean body mass index, 28 ± 6 kg/m2). Most of these procedures (69%) were elective. The FMD group had had a lower rate of hypertension (55% vs 82%; P = .002), smoking (35% vs 80%; P < .001), diabetes (13% vs 45%; P < .001), and coronary artery disease (9% vs 45%; P < .001) compared with the non-FMD group. In the FMD group, prior TIA and stroke was identified in 39 (71%) and 31 (57%) patients, respectively. The mean interval from a prior stroke or TIA to the index surgery was 160 days. Additionally, 23 patients (42%) had had anatomically high lesions above the level of the second cervical vertebra. In the FMD group, the transfemoral approach was used for 43 patients (78%), with distal embolic protection used for 40 patients (93%). Flow reversal was used for nine patients (23%). Most cases were performed with local anesthesia (58%). Three patients (6%) in the FMD group had had access site complications that were managed nonoperatively. No differences were found between the FMD and non-FMD groups in perioperative stroke, TIA, or 30-day mortality. The length of stay was similar between the two groups, and the 1-year survival was 100% for both groups. All the patients in the FMD group were discharged without neurologic complications, and 50 patients (91%) were receiving dual antiplatelet therapy. The median follow-up was 328 days (interquartile range, 1-732 days) with no mortality or reinterventions during follow-up. CONCLUSIONS: CAS for FMD is a feasible and safe procedure with favorable technical success, a low incidence of neurologic complications, and good clinical outcomes at 1 year of follow-up.


Assuntos
Estenose das Carótidas , Displasia Fibromuscular , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Masculino , Ataque Isquêmico Transitório/etiologia , Estenose das Carótidas/cirurgia , Estudos Retrospectivos , Displasia Fibromuscular/complicações , Resultado do Tratamento , Stents/efeitos adversos , Acidente Vascular Cerebral/etiologia , Fatores de Risco , Medição de Risco
12.
J Endovasc Ther ; 30(6): 964-970, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-35658606

RESUMO

Failed fenestrated-branched endovascular aortic repair (F-BEVAR) requiring a redo F-BEVAR is a rare event. In this study, we report 2 cases of a failed F-BEVAR secondary to a type IIIb endoleak from tears on the fabric graft successfully treated with redo F-BEVAR. This is a technically challenging procedure that requires meticulous planning, advanced imaging technologies and experienced operators. Redo F-BEVAR appears to be a feasible and safe treatment option. However, larger series and long-term follow-up are needed to confirm effectiveness and durability.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Estudos Retrospectivos , Fatores de Tempo , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Prótese Vascular
13.
J Vasc Surg ; 77(2): 415-423.e1, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36100032

RESUMO

OBJECTIVE: Chronic kidney disease (CKD) and end-stage renal disease are traditionally associated with worse outcomes after endovascular and open repair of abdominal aortic aneurysm (AAA). This study stratifies outcomes of AAA repair by approach, CKD severity, and dialysis dependence. METHODS: All patients undergoing elective infrarenal open aneurysm repair (OAR) and endovascular aortic repair (EVAR) with preoperative renal function data captured by the Vascular Quality Initiative between January 2003 and September 2020 were analyzed. Patients were stratified by CKD class as follows: CKD stages 1 and 2, CKD stage 3a, CKD stage 3b, CKD stages 4 and 5, and dialysis. Primary outcomes were perioperative and 1-year mortality. Predictors of survival were identified by Cox multivariate regression models. RESULTS: In total, 53,867 elective AAA repairs were identified: 5396 (10%) OARs and 48,471 (90%) EVARs. Most patients were White (90%) and male (81%), with a mean age of 73 ± 9 years. Patients who underwent EVAR were older and had more comorbidities. The use of elective EVAR for AAA increased from 52% in 2003 to 91% in 2020 (P < .001). The OAR cohort had more perioperative complications and short-term mortality. The CKD 1 and 2 group had the highest 1-year survival compared with the other groups after both OAR and EVAR. On Cox regression analysis, after EVAR, compared with CKD 1 and 2, worsening CKD stage (CKD 3a: hazard ratio [HR], 1.25; 95% confidence interval [CI], 0.93-1.68; P = .13; CKD 3b: HR, 1.74; 95% CI, 1.23-2.45; P < .050; CKD 4-5: HR, 3.23; 95% CI, 2.13-4.88; P < .001), and dialysis (HR, 4.48; 95% CI, 1.90-10.6; P < .001) were independently associated with worse 1-year survival rates. After OAR, compared with CKD 1 and 2, worsening CKD stage (CKD 3a: HR, 1.08; 95% CI, 0.96-1.20; P = .20; CKD 3b: HR, 1.60; 95% CI, 1.41-1.81; P < .001; CKD 4-5: HR, 2.85; 95% CI, 2.39-3.41; P < .001), and dialysis (HR, 3.79; 95% CI, 3.01-4.76; P < .001) were independently associated with worse 1-year survival rates. CONCLUSIONS: Regardless of the treatment approach, CKD severity is an important predictor of perioperative and 1-year mortality rates after infrarenal AAA repair and may reflect the natural history of CKD. Open repair is associated with high perioperative mortality risk in patients with CKD stages 4 and 5, as well as end-stage renal disease. Individualization of patient decision-making is especially important in patients with a glomerular filtration rate of less than 45 and perhaps consideration should be given to raising the threshold for elective AAA repair in these patients. Further studies focusing on appropriate size threshold for repair in these patients may be warranted.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Falência Renal Crônica , Insuficiência Renal Crônica , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Procedimentos Endovasculares/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Estudos Retrospectivos , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/terapia , Falência Renal Crônica/terapia , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos
14.
Ann Vasc Surg ; 89: 161-165, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36162628

RESUMO

BACKGROUND: The intensity of radiation scatter that emanates from the X-ray beam during fluoroscopically guided interventions is greater below the fluoroscopy table than above. Yet interventionalists' lower legs are typically unshielded and table skirts are often positioned incorrectly. We sought to characterize the efficacy of the leg protector wraps (Leg Wraps, Burlington Medical Inc.) in reducing the radiation dose to the operator's lower leg during fenestrated and branched endovascular aneurysm repair (F-BEVAR). METHODS: A prospective cohort study was performed evaluating the lower leg radiation dose reduction of one vascular surgeon during F/BEVAR using antimony/bismuth Enviro-Lite leg wraps (0.35 mm lead equivalency, 99.7% attenuation at 50 kVp; Burlington Medical, Hampton Roads, Virginia). Optically Stimulated Luminescence nanoDot detectors (microSTARii System, LANDAUER, Inc., Glenwood, Illinois) were placed over and under the left leg wrap at the anterior tibial tuberosity position to compare operator leg dose with and without this additional protection. The table-mounted lead skirt was used consistently in all cases. The nanoDot detectors were cross-calibrated with a survey meter (RaySafe X2 survey sensor, Fluke Biomedical, Cleveland, Ohio) by measuring scattered radiation at a position equivalent to an operator's mid-tibia while performing digital acquisitions of a 25-cm thick, 30 cm × 30 cm acrylic phantom with a Philips FD20 fluoroscope (Philips Healthcare, Best, The Netherlands) with the table skirt removed. The measured radiation doses were converted to a Hp (0.07) skin dose, assuming an RQR6 beam spectrum (IEC-61267). Paired Wilcoxon test was performed to identify significant attenuation of radiation exposure. RESULTS: Leg dose measurements from 40 F-BEVARs were analyzed. The patients had a median (interquartile range) body mass index of 27 (24-32) kg/m2. Median procedure reference air kerma was 1,100 (728-1,601) mGy, kerma-area product was 127 (73-184) Gycm2, and fluoroscopy time was 69 (54-86) min. The median skin dose Hp (0.07) over the leg wraps (n = 40) was 54.2 (24-100) µSv and under the leg wraps (n = 40) was 2.7 µSv (1.0-5.8). The leg wraps attenuated the radiation dose by 95% (89-98%) (P < 0.001). The unprotected, Hp (0.07) per kerma-area product was determined to be 0.38 (0.30-0.55) µSv/Gycm2. CONCLUSIONS: The 0.35-mm lead-equivalent leg wraps significantly decreased scattered radiation to the lower leg during F-BEVAR. Protective leg wraps should be recommended to operators performing complex fluoroscopically guided procedures.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Exposição Ocupacional , Exposição à Radiação , Monitoramento de Radiação , Humanos , Perna (Membro)/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/efeitos adversos , Estudos Prospectivos , Doses de Radiação , Monitoramento de Radiação/métodos , Resultado do Tratamento , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Fluoroscopia , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/prevenção & controle , Radiografia Intervencionista/efeitos adversos
15.
Ann Vasc Surg ; 86: 50-57, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35803463

RESUMO

BACKGROUND: The risk of rupture of renal artery aneurysms (RAAs) remains undefined. A recent paper from the Vascular Low-Frequency Disease Consortium (VLFDC) identified only 3 ruptures in 760 patients. However, over 80% of patients in the VLFDC study were treated at large academic centers, which may not reflect the pattern of care of RAAs nationwide. Thus, the purpose of this study was to evaluate the pattern of nonelective versus elective surgery requiring inpatient admission for RAAs, including nephrectomies, and their outcomes using a national database. METHODS: The National Inpatient Sample (NIS) database from 2012 to 2018 was utilized. Patients with a primary diagnosis of RAAs were identified using ICD-9 and ICD-10 codes. Ruptured RAAs (rRAAs) were identified utilizing surrogate ICD codes. The primary outcome variables for this study were proportion of RAAs requiring non-elective surgery and in-hospital mortality. RESULTS: A total of 590 inpatient admissions for RAA were identified with 554 procedures at 467 hospitals across the country. Of the 590 inpatient admissions, 380 (64.4%) admissions were deemed nonelective. There was an increasing proportion of nonelective admissions over the study period. The overall rate of nephrectomies was 7.1% (n = 42). In-hospital mortality rate for the cohort was 1.4% (n = 8) with no differences in in-hospital mortality in the elective versus nonelective setting (1.0% vs. 1.6%; P = 0.718). In the nonelective setting, patients requiring a nephrectomy (n = 23) had significantly higher rates of in-hospital mortality compared those not requiring a nephrectomy (8.7% vs. 1.1%, P = 0.045). rRAA (n = 50) patients had significantly higher in-hospital mortality compared to the remainder of the cohort (6.0% vs. 0.9%, P = 0.024). rRAA patients were also more likely to undergo a nephrectomy compared to the remainder of the cohort (16.0% vs. 6.3%, P = 0.019). CONCLUSIONS: These data demonstrate that treatment of RAAs are primarily done in the nonelective setting with a high proportion of ruptures, which could continue to rise as the threshold for repair has decreased.


Assuntos
Aneurisma , Doenças Ureterais , Humanos , Artéria Renal/cirurgia , Pacientes Internados , Resultado do Tratamento , Estudos Retrospectivos , Aneurisma/diagnóstico por imagem , Aneurisma/cirurgia , Mortalidade Hospitalar
16.
J Vasc Surg ; 76(2): 500-504, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35367567

RESUMO

BACKGROUND: Radiation exposure and imaging quality are among the main concerns in endovascular procedures. The Clear VD11 PURE platform technology system (Siemens Healthineers, Erlangen, Germany) has been reported to lower the radiation dose and improve image quality. In the present study, we evaluated whether the radiation dose during peripheral arterial endovascular procedures had decreased after implementation of this new imaging system. METHODS: The patient characteristics (age, gender, body mass index [BMI]), procedure type (diagnostic, balloon angioplasty, atherectomy, stenting), body location (aortoiliac, superficial femoral artery, tibial artery), reference air kerma (RAK), kerma area product (KAP), and fluoroscopy time (FT) were recorded during peripheral artery interventions performed 1 year before (group A) and 1 year after (group B) the CLEAR system upgrade. The procedures were performed in an Artis zeego hybrid room (Siemens Healthineers) with the same providers. A general linear model was used to estimate the average difference between groups adjusted by procedure type and patient age, gender, and BMI. Additionally, to control for variations in case complexity, groups A and B were matched by age, gender, BMI, lesion location, and intervention type. Propensity score matching and a paired t test were used to compare the KAP, RAK, and FT stratified by single intervention procedures. RESULTS: A total of 487 endovascular procedures were performed: 209 in group A and 278 in group B. A total of 111 single intervention procedures from each group were matched (1:1), with a mean age of 61 ± 8 years and a BMI of 26.5 ± 4 kg/m2. The median KAP, RAK, and FT for group A were 28.8 Gy · cm2 (interquartile range [IQR], 24-34 Gy · cm2), 146 mGy (IQR, 123-173 mGy), and 12 minutes (IQR, 10-14 minutes), respectively. The median KAP, RAK, and FT for group B were 18.3 Gy · cm2 (IQR, 16-22 Gy · cm2), 71.2 mGy (IQR, 60-85 mGy), and 10.4 minutes (IQR, 9-12 minutes), respectively. The KAP, RAK, and FT were significantly decreased in group B by 24% (P = .005), 41% (P < .001), and 22% (P = .002), respectively, compared with the values for group A. Stratified by single intervention procedures, the KAP and RAK had decreased significantly in group B (36% [P = .002] and 51% [P < .001], respectively) compared with group A. The FT decrease of 13% in group B was not statistically significant (P = .20). CONCLUSIONS: Use of the Clear VD11 PURE platform system (Siemens Healthineers) reduced the patient radiation dose by 51% during endovascular peripheral interventions. The similar FTs for the matched single intervention procedures before and after the upgrade indicated consistent case complexity and surgeon practice. This platform appears to be an effective system for lowering the radiation dose.


Assuntos
Procedimentos Endovasculares , Exposição à Radiação , Idoso , Procedimentos Endovasculares/efeitos adversos , Artéria Femoral/diagnóstico por imagem , Fluoroscopia , Humanos , Pessoa de Meia-Idade , Doses de Radiação , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/efeitos adversos , Tecnologia
17.
J Vasc Surg ; 75(5): 1570-1576, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34995718

RESUMO

OBJECTIVE: Blunt abdominal aortic injury in children is a rare clinical entity with which most vascular surgeons have minimal experience. The evidence for management recommendations is limited. We have reported a single institution's experience in the care of pediatric abdominal aortic injuries. METHODS: We performed a retrospective review of consecutive pediatric patients who had been diagnosed with blunt traumatic abdominal aortic injury at our institution from 2008 to 2019. RESULTS: A total of 16 pediatric patients (50% male) were identified. They ranged in age from 4 to 17 years. All had been involved in motor vehicle collisions and had been restrained passengers with a seatbelt in use. Five patients (31%) were hypotensive en route or on arrival. Seven patients (44%) had been transferred from another hospital. The median injury severity score was 34 (interquartile range, 19-35). The infrarenal aortic injuries were stratified using the aortic injury grading classification (five, two, seven, and two with grade 1, 2, 3, and 4, respectively). Concurrent nonaortic injuries included solid organ (63%; n = 10), hollow viscus (88%; n = 14), brain (25%; n = 4), hemothorax or pneumothorax (25%; n = 4), spine fractures (81%; n = 13), and nonspine fractures (75%; n = 12). Of the 16 patients, 9 (56%) had required aortic repair. Three had required immediate revascularization for distal ischemia. The remaining six patients (38%) had undergone delayed repair, with a median interval to repair of 52 days (range, 2-916 days). One half of the delayed repairs were performed during the index hospitalization. On repeat axial imaging, the three patients who had undergone delayed repair were found to have enlarging pseudoaneurysms or flow-limiting dissections and had subsequently undergone repair during the index hospitalization. Only one patient had undergone endovascular repair. No deaths occurred, and the median follow-up was 7 months (interquartile range, 3-28 months) for our study population. All postoperative patients demonstrated stable imaging findings without requiring further intervention. Seven patients, whose injury grades had ranged from 1 to 3, were observed. Their repeat imaging studies demonstrated either stability or resolution of their aortic injury. However, one half of the patients had been lost to follow-up after discharge or after their first postoperative clinic visit. CONCLUSIONS: Delayed aortic intervention can be safely performed for most pediatric patients with blunt abdominal aortic injuries with preserved distal perfusion to the lower extremities. This finding suggests that transfer to a tertiary center with vascular expertise is a safe and feasible management strategy. However, the progression of aortic injuries was seen as early as within 48 hours and as late as 30 months after injury, underscoring the importance of long-term surveillance. However, in our cohort, 50% of the children were lost to follow-up, highlighting the need for a more structured surveillance strategy.


Assuntos
Traumatismos Abdominais , Doenças da Aorta , Lesões do Sistema Vascular , Ferimentos não Penetrantes , Adolescente , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/lesões , Aorta Abdominal/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/lesões , Aorta Torácica/cirurgia , Criança , Pré-Escolar , Feminino , Humanos , Escala de Gravidade do Ferimento , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/cirurgia , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/cirurgia
18.
J Vasc Surg ; 75(3): 794-802, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34597786

RESUMO

OBJECTIVE: Upper extremity (UE) access is frequently used for fenestrated-branched endovascular aortic aneurysm repair (F-BEVAR), particularly for complex repairs. Traditionally, left-side UE access has been used to avoid crossing the arch and the origin of the supra-aortic vessels, which could potentially result in cerebral embolization and an increased risk of perioperative cerebrovascular events. More recently, right UE has been more frequently used as it is more convenient and ergonomic. The purpose of this study was to assess the outcomes and cerebrovascular events after F-BEVAR with the use of right- vs left-side UE access. METHODS: During an 8-year period, 453 patients (71% male) underwent F-BEVAR at a single institution. UE access was used in more complex repairs. Left UE access was favored in the past, whereas right UE access is currently the preferred UE access side. Brachial artery cutdown was used in all patients for the placement of a 12F sheath. Outcomes were compared between patients undergoing right vs left UE access. End points included cerebrovascular events, perioperative mortality, technical success, and local access-related complications. RESULTS: UE access was used in 361 (80%) patients. The right side was used in 232 (64%) and the left side in 129 (36%) patients for the treatment of 88 (25%) juxtarenal, 135 (38%) suprarenal, and 137 (38%) thoracoabdominal aortic aneurysms. Most procedures were elective (94%). Technical success was achieved in 354 patients (98%). In-patient or 30-day mortality was 3.3%. Five (1%) perioperative strokes occurred in patients undergoing right UE access, of which three were ischemic and two were hemorrhagic. No transient ischemic attacks occurred perioperatively. Two hemorrhagic strokes were associated with permissive hypertension to prevent spinal cord ischemia. No perioperative strokes occurred in patients undergoing left UE access (P = .16). Overall, perioperative strokes occurred with similar frequency in patients undergoing UE (5, 1%) and femoral access only (1, 1%) (P = .99). Arm access-related complications occurred in 15 (5%) patients, 11 (4.8%) on the right side and 4 (6%) on the left side (P = .74). CONCLUSIONS: Right UE access can be used for F-BEVAR with low morbidity and minimal risk of perioperative ischemic stroke or transient ischemic attacks. In general, UE access is not associated with an increased risk of perioperative stroke compared with femoral access only. Tight blood pressure control is, however, critical to avoid intracranial bleeding related to uncontrolled hypertension.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Cateterismo Periférico/efeitos adversos , Transtornos Cerebrovasculares/etiologia , Procedimentos Endovasculares/efeitos adversos , Extremidade Superior/irrigação sanguínea , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Cateterismo Periférico/mortalidade , Transtornos Cerebrovasculares/diagnóstico por imagem , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Acidente Vascular Cerebral Hemorrágico/etiologia , Humanos , Ataque Isquêmico Transitório/etiologia , AVC Isquêmico/etiologia , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
19.
J Vasc Surg ; 75(6): 2047-2053, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34923065

RESUMO

OBJECTIVE: Long-term radiation exposure from fluoroscopically guided interventions (FGIs) can cause cataracts and brain tumors in the operator. We have previously demonstrated that leaded eyewear does not decrease the operator eye radiation dose unless lead shielding has been added to the lateral and inferior portions. Therefore, we have developed a disposable, lightweight, lead-equivalent shield that can be attached to the operator's eyewear that conforms to the face and adheres to the surgical mask. In the present study, we evaluated the efficacy of our new prototype in lowering the operator brain and eye radiation dose when added to both leaded and nonleaded eyewear. METHODS: The attenuating efficacy of leaded eyewear alone, leaded eyewear plus the prototype, and nonleaded eyewear plus the prototype were compared with no eyewear protection in both a simulated setting and clinical practice. In the simulation, optically stimulated, luminescent nanoDot detectors (Landauer, Inc, Glenwood, Ill) were placed inside the ocular, temporal lobe, and midbrain spaces of a head phantom (ATOM model-701; CIRS, Norfolk, Va). The phantom was positioned to represent a primary operator performing right femoral access. Fluorography was performed on a plastic scatter phantom at 80 kVp for an exposure of 3 Gy reference air kerma. In the clinical setting, nanoDots were placed below the operator's eye both inside and outside the prototype during the FGIs. The median and interquartile ranges were calculated for the dose at each nanoDot location for the phantom and clinical studies. The average dose reduction was also recorded. RESULTS: Wearing standard leaded eyewear alone did not decrease the operator ocular or brain radiation dose. In the phantom experiment, the leaded glasses plus the prototype reduced the radiation dose to the lens, temporal lobe, and midbrain by 83% (P < .001), 78% (P < .001), and 75% (P < .001), respectively. The nonleaded glasses plus the prototype also reduced the dose to the lens, temporal lobe, and midbrain by 85% (P < .001), 81% (P < .001), and 71% (P < .001), respectively. A total of 15 FGIs were included in the clinical setting, with a median reference air kerma of 98.4 mGy. The use of our prototype led to an average operator eye dose reduction of 89% (P < .001). CONCLUSIONS: Attaching our prototype to both leaded and nonleaded glasses significantly decreased the eye and brain radiation dose to the operator. This face shield attachment provided meaningful radiation protection and should be considered as either a replacement or an adjunct to routine eyewear.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Encéfalo , Humanos , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle
20.
J Endovasc Ther ; 29(3): 381-388, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34622707

RESUMO

PURPOSE: Treatment decisions for the elderly with abdominal aortic aneurysms (AAAs) are challenging. With advancing age, the risk of endovascular aneurysm repair (EVAR) increases while life expectancy decreases, which may nullify the benefit of EVAR. The purpose of this study was to quantify the impact of EVAR on 1-year mortality in patients of advanced age. MATERIALS AND METHODS: The 2003-2020 Vascular Quality Initiative Database was utilized to identify patients who underwent EVAR for AAAs. Patients were included if they were 80 years of age or older. Exclusions included non-elective surgery or missing aortic diameter data. Predicted 1-year mortality of untreated AAAs was calculated based on a validated comorbidity score that predicts 1-year mortality (Gagne Index, excluding the component associated with AAAs) plus the 1-year aneurysm-related mortality without repair. The primary outcome for the study was 1-year mortality. RESULTS: A total of 11 829 patients met study criteria. The median age was 84 years [81, 86] with 9014 (76.2%) being male. Maximal AAA diameters were apportioned as follows: 39.6% were <5.5 cm, 28.6% were 5.5-5.9 cm, 21.3% were 6.0-6.9 cm, and 10.6% were ≥7.0 cm. The predicted 1-year mortality rate without EVAR was 11.9%, which was significantly higher than the actual 1-year mortality rate with EVAR (8.2%; p<0.001). The overall rate of perioperative MACE was 4.4% (n = 516). Patients with an aneurysm diameter <5.5cm had worse actual 1-year mortality rates with EVAR compared to predicted 1-year mortality rates without EVAR. In contrast, those with larger aneurysms (≥5.5cm) had better actual 1-year mortality rates with EVAR. The benefit from EVAR for those with Gagne Indices 2-5 was largely restricted to those with AAAs ≥ 7.0cm; whereas those with Gagne Indices 0-1 experience a survival benefit for AAAs larger than 5.5 cm. CONCLUSION: The current data suggest that EVAR decreases 1-year mortality rates for patients of advanced age compared to non-operative management in the elderly. However, the survival benefit is largely limited to those with Gagne Indices 0-1 with AAAs ≥ 5.5 cm and Gagne Indices 2-5 with AAAs ≥ 7.0 cm. Those of advanced age may benefit from EVAR, but realizing this benefit requires careful patient selection.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma Aórtico , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/cirurgia , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA