Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Infect Chemother ; 30(7): 590-596, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38159641

RESUMO

INTRODUCTION: Tick-borne diseases (TBDs) are a growing threat in Japan. However, distribution of ticks and their possession of human pathogens remain poorly understood. METHODS: In the present study, we collected 3477 ticks at 6 remote, woodland sites in Ibaraki prefecture between May 23 and November 4, 2021, and investigated the distribution and the possession of spotted fever group Rickettia (SFGR). RESULTS: The collected ticks included Haemaphysalis flava (78.3 %), Haemaphysalis longicornis (9.0 %), Haemaphysalis hystricis (4.6 %), Ixodes turdus (4.3 %), Amblyomma testudinarium (2.1 %), Haemaphysalis cornigera (0.9 %), Haemaphysalis formosensis (0.9 %), Haemaphysalis megaspinosa (0.2 %), Ixodes ovatus (0.1 %), Ixodes nipponensis (0.09 %), and Ixodes columnae (0.03 %). Of 2160 DNA samples extracted from the ticks, the gltA gene and the 17-kDa antigen gene of SFGR were detected in 67 samples. Among 1682 samples from adult and nymph ticks, the positive rate of SFGR was 2.7 %. Sequence analyses of the partial 17-kDa antigen gene demonstrated that the detected SFGR were classified into 8 groups (G1 to G8). The sequences of G2, G4, G5, G6, and G7 were either identical to or differed by one base pair from those of Rickettsia asiatica, Rickettsia tamurae, Rickettsia monacensis, Rickettsia canadensis, and Rickettsia felis, respectively. CONCLUSION: The present study revealed a diverse tick fauna in Ibaraki prefecture, including detection of species commonly found in southwestern Japan. Although the prevalence of SFGR in ticks was lower than in previous studies, several SFGR causing human infection may be present.


Assuntos
Rickettsia , Animais , Japão/epidemiologia , Rickettsia/isolamento & purificação , Rickettsia/genética , Rickettsia/classificação , Rickettsiose do Grupo da Febre Maculosa/epidemiologia , Rickettsiose do Grupo da Febre Maculosa/microbiologia , Humanos , Feminino , Masculino , Carrapatos/microbiologia , Ixodidae/microbiologia , Doenças Transmitidas por Carrapatos/epidemiologia , Doenças Transmitidas por Carrapatos/microbiologia , DNA Bacteriano/genética , Filogenia
2.
Sci Rep ; 13(1): 17546, 2023 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-37845364

RESUMO

We designed and developed two new types of hydrogen fuel cell (HFC) buses (motorcoach and minibus) with a mobile laboratory system. Feasibility studies have been performed for mobile laboratory testing, particularly for the laboratory performance of COVID-19 RT-PCR (PCR). We evaluated the driving range capability, PCR sample size capacity, turnaround time (TAT), and analytical performance for the detection of SARS-CoV-2. Saliva samples were used for the current study, and the analytical performance was compared with that of the reference PCR. The estimated driving range and sample size capacity of the HFC and HFC minibus were 432 km and 2847 samples, respectively, for the HFC motorcoach and 313 km and 1949 samples for the HFC minibus. For the TAT, the median time between sample submission and completion of PCR was 86 min for the motorcoach and 76 min for the minibus, and the median time between sample submission and electronic reporting of the result to each visitor was 182 min for the motorcoach and 194 min for the minibus. A secondary analysis of 1574 HFC mobile laboratory testing samples was conducted, and all negative samples were found to be negative by reference PCR. Furthermore, all samples were confirmed to be positive by reference PCR or other molecular examinations.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2/genética , Teste de Ácido Nucleico para COVID-19 , Teste para COVID-19 , Veículos Automotores , Sensibilidade e Especificidade
3.
J Infect Chemother ; 29(3): 257-262, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36417995

RESUMO

INTRODUCTION: Rapid qualitative antigen testing is essential in the clinical management of COVID-19. However, most evaluations of antigen tests have been performed before the emergence of the Omicron variant. METHODS: This prospective observational study evaluated QuickNavi-COVID19 Ag, a rapid antigen detection test between December 2021 and February 2022 in Japan, using real-time reverse transcription (RT)-PCR as a reference. Two nasopharyngeal samples were simultaneously collected for antigen testing and for RT-PCR. Variant analysis of the SARS-CoV-2 genomic sequencing was also performed. RESULTS: In total, nasopharyngeal samples were collected from 1073 participants (417 positive; 919 symptomatic; 154 asymptomatic) for analysis. Compared with those of RT-PCR, the sensitivity, specificity, positive predictive value, and negative predictive value were 94.2% (95% CI: 91.6%-96.3%), 99.5% (95% CI: 98.7%-99.9%), 99.2% (95% CI: 97.8%-99.8%), and 96.5% (95% CI: 94.8%-97.7%), respectively. The sensitivity among symptomatic individuals was 94.3% (95% CI: 91.5%-96.4%). Overall, 85.9% of sequences were classified as Omicron sublineage BA.1, 12.4% were Omicron sublineage BA.2, and 1.6% were Delta B.1.617.2. (Delta variant). Most of the samples (87.1%) had Ct values of <25, and the sensitivity was 47.4% for low viral load samples (Ct ≥ 30); a similar trend has been observed in both symptomatic and asymptomatic groups. CONCLUSIONS: The QuickNavi-COVID19 Ag test showed sufficient diagnostic performance for the detection of the SARS-CoV-2 Omicron sublineages BA.1 and BA.2 from nasopharyngeal samples. However, the current study was mainly performed in symptomatic patients and the results are not sufficiently applicable for asymptomatic patients.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Japão , Reação em Cadeia da Polimerase em Tempo Real , Sensibilidade e Especificidade
4.
Mol Diagn Ther ; 26(3): 323-331, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35391608

RESUMO

BACKGROUND AND OBJECTIVE: Point-of-care type molecular diagnostic tests have been used for detecting SARS-CoV-2, although their clinical utility with nasal samples has yet to be established. This study evaluated the clinical performance of the cobas Liat SARS-CoV-2 & Influenza A/B (Liat) assay in nasal samples. METHODS: Nasal and nasopharyngeal samples were collected and were tested using the Liat, the cobas 6800 system and the cobas SARS-CoV-2 & Influenza A/B (cobas), and a method developed by National Institute of Infectious Diseases, Japan (NIID). RESULTS: A total of 814 nasal samples were collected. The Liat assay was positive for SARS-CoV-2 in 113 (13.9%). The total, positive, and negative concordance rate between the Liat and cobas/NIID assays were 99.3%/98.4%, 99.1%/100%, and 99.3%/98.2%, respectively. Five samples were positive only using the Liat assay. Their Ct values ranged from 31.9 to 37.2. The Ct values of the Liat assay were significantly lower (p < 0.001) but were correlated (p < 0.001) with those of other molecular assays. In the participants who tested positive for SARS-CoV-2 on the Liat assay using nasopharyngeal samples, 88.2% of their nasal samples also tested positive using the Liat assay. CONCLUSION: The Liat assay showed high concordance with other molecular assays in nasal samples. Some discordance occurred in samples with Ct values > 30 on the Liat assay.


Assuntos
COVID-19 , Influenza Humana , COVID-19/diagnóstico , Humanos , Influenza Humana/diagnóstico , Nasofaringe , SARS-CoV-2 , Sensibilidade e Especificidade
5.
J Infect Chemother ; 28(6): 780-785, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35256268

RESUMO

INTRODUCTION: The diagnostic accuracy of antigen testing of anterior nasal (AN) samples for the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection has not been evaluated in the Japanese population. This study assessed the diagnostic accuracy of the Roche SARS-CoV-2 rapid antigen test (rapid antigen test) using AN samples. METHODS: Two AN samples and one nasopharyngeal (NP) sample were collected from individuals undergoing screening for SARS-CoV-2 infection. The results of the rapid antigen test and the reverse-transcription polymerase chain reaction (RT-PCR) test using AN samples were compared to those of RT-PCR tests using NP samples. RESULTS: Samples were collected from 800 participants, 95 and 110 of whom tested positive for SARS-CoV-2 on RT-PCR tests of AN and NP samples, respectively. The overall sensitivity/specificity of the AN rapid antigen test and AN RT-PCR were 72.7%/100% and 86.4%/100%, respectively. In symptomatic cases, the sensitivities of the AN rapid antigen test and AN RT-PCR were 84.7% and 94.9%, respectively. In asymptomatic cases, the sensitivities of the AN rapid antigen test and AN RT-PCR were 58.8% and 76.5%, respectively. The sensitivity of the AN rapid antigen test was over 80% in cases with cycle threshold (Ct) values < 25; it significantly decreased with an increase in the Ct values (p < 0.001). CONCLUSION: The rapid antigen test with AN samples had a favorable sensitivity, especially in symptomatic cases or in cases with Ct values < 25. It gave no false-positive results. Compared with AN-RT PCR, the AN rapid antigen test had a modestly lower sensitivity in asymptomatic cases.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Teste Sorológico para COVID-19 , Humanos , Nasofaringe , Estudos Prospectivos , SARS-CoV-2/genética , Sensibilidade e Especificidade
6.
J Infect Chemother ; 28(6): 840-843, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35277343

RESUMO

INTRODUCTION: Since respiratory sample collection is an uncomfortable experience, simultaneous detection of pathogens with a single swab is preferable. We prospectively evaluated the clinical performance of a newly developed antigen test QuickNavi-Flu+COVID19 Ag (Denka Co., Ltd., Tokyo, Japan) which can detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza viruses at the same time with a single testing device. METHODS: We included those who were suspected of contracting coronavirus disease 2019 (COVID-19) and were referred to a PCR center at Ibaraki prefecture in Japan, between August 2, 2021 to September 13, 2021, when the variant carrying L452R spike mutation of SARS-CoV-2 were prevalent. Additional nasopharyngeal samples and anterior nasal samples were obtained for the antigen test and were compared with a reference real-time reverse transcription PCR (RT-PCR) using nasopharyngeal samples. RESULTS: In total, 1510 nasopharyngeal samples and 862 anterior nasal samples were evaluated. During the study period, influenza viruses were not detected by QuickNavi-Flu+COVID19 Ag and reference real-time RT-PCR. For SARS-CoV-2 detection in nasopharyngeal samples, the sensitivity and specificity of the antigen test were 80.9% and 99.8%, respectively. The sensitivity and specificity using anterior nasal samples were 67.8% and 100%, respectively. In symptomatic cases, the sensitivities increased to 88.3% with nasopharyngeal samples and 73.7% with anterior nasal samples. There were three cases of discrepant results between the antigen test and the real-time RT-PCR. All of them were positive with the antigen test but negative with the real-time RT-PCR in SARS-CoV-2 detection. CONCLUSION: A combo kit, QuickNavi-Flu+COVID19 Ag, showed an acceptable sensitivity and sufficient specificity for SARS-CoV-2 detection, especially using nasopharyngeal sample collected from symptomatic patients.


Assuntos
COVID-19 , Antígenos Virais/análise , COVID-19/diagnóstico , Teste Sorológico para COVID-19 , Humanos , Nasofaringe , SARS-CoV-2/genética , Sensibilidade e Especificidade
7.
Multidiscip Respir Med ; 17(2): 802, 2022 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-35127079

RESUMO

Pneumocystis jirovecii pneumonia (PCP) in patients with acquired immune deficiency syndrome (AIDS) shows eosinophilic pneumonia like condition. The detailed mechanisms how AIDS-associated PCP causes eosinophilic pneumonia has not been elucidated, but it has been suggested that beta-D-glucan, a major component of Pneumocystis jirovecii, and T helper type 2 immunity may be involved in the mechanism of eosinophilia in the lung. We experienced the case who developed an eosinophilic pneumonia-like condition in a patient with AIDS-associated PCP, whose clinical course indicated the importance of TARC/CCL17 but not IL-4 and IL-5 as involved in eosinophilia caused by HIV and Pneumocystis jirovecii infection.

8.
J Infect Chemother ; 28(4): 543-547, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35016829

RESUMO

INTRODUCTION: Smart Gene is a point-of-care (POC)-type automated molecular testing platform that can be performed with 1 min of hands-on-time. Smart Gene SARS-CoV-2 is a newly developed Smart Gene molecular assay for the detection of SARS-CoV-2. The analytical and clinical performance of Smart Gene SARS-CoV-2 has not been evaluated. METHODS: Nasopharyngeal and anterior nasal samples were prospectively collected from subjects referred to the local PCR center from March 25 to July 5, 2021. Two swabs were simultaneously obtained for the Smart Gene SARS-CoV-2 assay and the reference real-time RT-PCR assay, and the results of Smart Gene SARS-CoV-2 were compared to the reference real-time RT-PCR assay. RESULTS: Among a total of 1150 samples, 68 of 791 nasopharyngeal samples and 51 of 359 anterior nasal samples were positive for SARS-CoV-2 in the reference real-time RT-PCR assay. In the testing of nasopharyngeal samples, Smart Gene SARS-CoV-2 showed the total, positive and negative concordance of 99.2% (95% confidence interval [CI]: 98.4-99.7%), 94.1% (95% CI: 85.6-98.4%) and 99.7% (95% CI: 99.0-100%), respectively. For anterior nasal samples, Smart Gene SARS-CoV-2 showed the total, positive and negative concordance of 98.9% (95% CI: 97.2-99.7%), 98.0% (95% CI: 89.6-100%) and 99.0% (95% CI: 97.2-99.8%), respectively. In total, 5 samples were positive in the reference real-time RT-PCR assay and negative in the Smart Gene SARS-CoV-2 assay, whereas 5 samples were negative in the reference real-time RT-PCR assay and positive in the Smart Gene SARS-CoV-2 assay. CONCLUSION: Smart Gene SARS-CoV-2 showed sufficient analytical performance for the detection of SARS-CoV-2 in nasopharyngeal and anterior nasal samples.


Assuntos
COVID-19 , Ácidos Nucleicos , COVID-19/diagnóstico , Humanos , Nasofaringe , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos , SARS-CoV-2/genética , Sensibilidade e Especificidade
9.
J Infect Chemother ; 28(1): 78-81, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34736814

RESUMO

INTRODUCTION: Digital immunoassays are generally regarded as superior tests for the detection of infectious disease pathogens, but there have been insufficient data concerning SARS-CoV-2 immunoassays. METHODS: We prospectively evaluated a novel digital immunoassay (RapidTesta SARS-CoV-2). Two nasopharyngeal samples were simultaneously collected for antigen tests and Real-time RT-PCR. RESULTS: During the study period, 1127 nasopharyngeal samples (symptomatic patients: 802, asymptomatic patients: 325) were evaluated. For digital immunoassay antigen tests, the sensitivity was 78.3% (95% CI: 67.3%-87.1%) and the specificity was 97.6% (95% CI: 96.5%-98.5%). When technicians visually analyzed the antigen test results, the sensitivity was 71.6% (95% CI: 59.9%-81.5%) and the specificity was 99.2% (95% CI: 98.5%-99.7%). Among symptomatic patients, the sensitivity was 89.4% (95% CI; 76.9%-96.5%) with digital immunoassay antigen tests, and 85.1% (95% CI; 71.7%-93.8%) with visually analyzed the antigen test, respectively. CONCLUSIONS: The sensitivity of digital immunoassay antigen tests was superior to that of visually analyzed antigen tests, but the rate of false-positive results increased with the introduction of a digital immunoassay device.


Assuntos
COVID-19 , SARS-CoV-2 , Antígenos Virais , Humanos , Imunoensaio , Sensibilidade e Especificidade
10.
J Infect Chemother ; 28(2): 248-251, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34799237

RESUMO

INTRODUCTION: Antigen tests for severe acute respiratory coronavirus 2 sometimes show positive lines earlier than their specified read time, although the implication of getting the results at earlier time is not well understood. METHODS: We prospectively collected additional nasopharyngeal samples from patients who had already tested positive for SARS-CoV-2 by reverse transcription PCR. The swab was used for an antigen test, QuickNavi™-COVID19 Ag, and the time periods to get positive results were measured. RESULTS: In 84 of 96 (87.5%) analyzed cases, the results of QuickNavi™-COVID19 Ag were positive. The time to obtain positive results was 15.0 seconds in median (inter quartile range: 12.0-33.3, range 11-736) and was extended in samples with higher cycle thresholds (p < 0.001). Positive lines appeared within a minute in 85.7% of cases and within 5 min in 96.4%. CONCLUSION: QuickNavi™-COVID19 Ag immediately showed positive results in most cases, and the time to a positive reaction may have indicated the viral load.


Assuntos
COVID-19 , SARS-CoV-2 , Testes Diagnósticos de Rotina , Humanos , Nasofaringe , Sensibilidade e Especificidade
11.
PLoS One ; 16(12): e0262159, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34972195

RESUMO

INTRODUCTION: GENECUBE® is a rapid molecular identification system, and previous studies demonstrated that GENECUBE® HQ SARS-CoV-2 showed excellent analytical performance for the detection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) with nasopharyngeal samples. However, other respiratory samples have not been evaluated. METHODS: This prospective comparison between GENECUBE® HQ SARS-CoV-2 and reference real-time reverse transcriptase polymerase chain reaction (RT-PCR) was performed for the detection of SARS-CoV-2 using anterior nasal samples and saliva samples. Additionally, we evaluated a new rapid examination protocol using GENECUBE® HQ SARS-CoV-2 for the detection of SARS-CoV-2 with saliva samples. For the rapid protocol, in the preparation of saliva samples, purification and extraction processes were adjusted, and the total process time was shortened to approximately 35 minutes. RESULTS: For 359 anterior nasal samples, the total-, positive-, and negative concordance of the two assays was 99.7% (358/359), 98.1% (51/52), and 100% (307/307), respectively. For saliva samples, the total-, positive-, and negative concordance of the two assays was 99.6% (239/240), 100% (56/56), and 99.5% (183/184), respectively. With the new protocol, total-, positive-, and negative concordance of the two assays was 98.8% (237/240), 100% (56/56), and 98.4% (181/184), respectively. In all discordance cases, SARS-CoV-2 was detected by additional molecular examinations. CONCLUSION: GENECUBE® HQ SARS-CoV-2 provided high analytical performance for the detection of SARS-CoV-2 in anterior nasal samples and saliva samples.


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , Testes Diagnósticos de Rotina/métodos , Nasofaringe/virologia , Pandemias , Saliva/virologia , Humanos , Estudos Prospectivos
12.
J Infect Chemother ; 27(10): 1493-1497, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34294528

RESUMO

INTRODUCTION: Rapid antigen tests are convenient for diagnosing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2); however, they have lower sensitivities than nucleic acid amplification tests. In this study, we evaluated the diagnostic performance of Quick Chaser® Auto SARS-CoV-2, a novel digital immunochromatographic assay that is expected to have higher sensitivity than conventional antigen tests. METHODS: A prospective observational study was conducted between February 8 and March 24, 2021. We simultaneously obtained two nasopharyngeal samples, one for evaluation with the QuickChaser® Auto SARS-CoV-2 antigen test and the other for assessment with reverse transcription PCR (RT-PCR), considered the gold-standard reference test. The limit of detection (LOD) of the new antigen test was compared with those of four other commercially available rapid antigen tests. RESULTS: A total of 1401 samples were analyzed. SARS-CoV-2 was detected by reference RT-PCR in 83 (5.9%) samples, of which 36 (43.4%) were collected from symptomatic patients. The sensitivity, specificity, positive predictive value, and negative predictive value were 74.7% (95% confidence interval (CI): 64.0-83.6%), 99.8% (95% CI: 99.5-100%), 96.9% (95% CI: 89.2-99.6%), and 98.4% (95% CI: 97.6-99.0%), respectively. When limited to samples with a cycle threshold (Ct) < 30 or those from symptomatic patients, the sensitivity increased to 98.3% and 88.9%, respectively. The QuickChaser® Auto SARS-CoV-2 detected 34-120 copies/test, which indicated greater sensitivity than the other rapid antigen tests. CONCLUSIONS: QuickChaser® Auto SARS-CoV-2 showed sufficient sensitivity and specificity in clinical samples of symptomatic patients. The sensitivity was comparable to RT-PCR in samples with Ct < 30.


Assuntos
COVID-19 , SARS-CoV-2 , Antígenos Virais , Humanos , Imunoensaio , Sensibilidade e Especificidade , Prata
13.
J Infect Chemother ; 27(10): 1489-1492, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34301485

RESUMO

INTRODUCTION: Antigen testing may help screen for and detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections in asymptomatic individuals. However, limited data regarding the diagnostic performance of antigen tests for this group are available. METHODS: We used clinical samples to prospectively evaluate the analytical and clinical performance of the antigen test QuickNavi™-COVID19 Ag. This study was conducted at a PCR center between October 7, 2020 and January 9, 2021. Two nasopharyngeal samples per patient were obtained with flocked swabs; one was used for the antigen test, and the other for real-time reverse transcription PCR (RT-PCR). The diagnostic performance of the antigen test was compared between asymptomatic and symptomatic patients, and the RT-PCR results were used as a reference. RESULTS: Among the 1934 collected samples, 188 (9.7%) demonstrated detection of SARS-CoV-2 by real-time RT-PCR; 76 (40.4%) of these 188 samples were from asymptomatic individuals, and over half of the total samples were asymptomatic (1073; 55.5%). The sensitivity of the antigen test was significantly lower for the asymptomatic group than for symptomatic patients (67.1% vs. 89.3%, respectively, p < 0.001). The specificity was 100% for both groups, and no false positives were observed among all 1934 samples. The median cycle threshold value for the asymptomatic group was significantly higher than that of the symptomatic group (24 vs. 20, p < 0.001). CONCLUSIONS: The QuickNavi™-COVID19 Ag showed lower sensitivity for the asymptomatic group than for symptomatic patients. However, its specificity was consistently high, and no false positives were found in this study.


Assuntos
Infecções Assintomáticas , Teste Sorológico para COVID-19 , COVID-19 , Antígenos Virais , COVID-19/diagnóstico , Humanos , Estudos Prospectivos , SARS-CoV-2 , Sensibilidade e Especificidade
14.
Mol Diagn Ther ; 25(4): 495-504, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34003471

RESUMO

BACKGROUND: Molecular tests are the mainstay of detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). However, their accessibility can be limited by the long examination time and inability to evaluate multiple samples at once. OBJECTIVE: This study evaluated the analytical performance of the newly developed rapid molecular assays GENECUBE® HQ SARS-CoV-2 and GENECUBE® FLU A/B. METHOD: This prospective study was conducted between 14 December 2020 and 9 January 2021 at a polymerase chain reaction (PCR) center. Samples were collected from the nasopharynx with flocked swabs. Molecular tests were performed with the GENECUBE® system and reference reverse transcription (RT)-PCR, and the results of the two assays were compared. RESULT: Among 1065 samples, 81 (7.6%) were positive for SARS-CoV-2 on the reference RT-PCR. Three showed discordance between GENECUBE® HQ SARS-CoV-2 and the reference RT-PCR; the total, positive, and negative samples of concordance for the two assays were 99.7%, 100%, and 99.7%, respectively. All discordant cases were positive with GENECUBE® HQ SARS-CoV-2 and negative with the reference RT-PCR. SARS-CoV-2 was detected in all three samples using another molecular assay for SARS-CoV-2. For GENECUBE® FLU A/B, the total, positive, and negative samples of concordance for the two assays were 99.5%, 100%, and 99.1%. CONCLUSION: The GENECUBE® HQ SARS-CoV-2 and GENECUBE® FLU A/B demonstrated sufficient analytical performance to detect SARS-CoV-2 and influenza virus A/B.


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , Reação em Cadeia da Polimerase em Tempo Real/métodos , SARS-CoV-2/genética , Benchmarking , COVID-19/virologia , Teste de Ácido Nucleico para COVID-19/instrumentação , Humanos , Nasofaringe/virologia , Estudos Prospectivos , Reação em Cadeia da Polimerase em Tempo Real/instrumentação , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade
15.
J Infect Chemother ; 27(8): 1238-1243, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33722464

RESUMO

Although a variety of microorganisms have caused infective endocarditis, Nocardia species have rarely been reported as a causative agent of the disease. We describe a case of nocardial endocarditis, occurring to a 22-year-old Japanese woman during long-term corticosteroid therapy for adult-onset Still's disease and diagnosed after the rupture of cerebral mycotic aneurysm. Echocardiography showed that the causative organism, isolated from the blood and identified as Nocardia nova with an analysis of 16S ribosomal RNA sequences, affected the posterior papillary muscle of the left ventricle. Nocardia-like organisms were also detected in the pus around the raptured aneurysm. After treatment with imipenem/cilastatin plus amikacin for 3 months followed by oral trimethoprim/sulfamethoxazole for 1 year, no relapse of nocardiosis occurred during a follow-up for 3 years. To our knowledge, the present case is the first reported endocarditis due to N. nova.


Assuntos
Endocardite Bacteriana , Nocardiose , Nocardia , Adulto , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/tratamento farmacológico , Feminino , Humanos , Nocardia/genética , Nocardiose/diagnóstico , Nocardiose/tratamento farmacológico , Combinação Trimetoprima e Sulfametoxazol/uso terapêutico , Adulto Jovem
16.
J Infect Chemother ; 26(5): 475-482, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31924521

RESUMO

We examined microbiological and clinical characteristics of invasive Acinetobacter infection occurring in four hospitals located in the Minami-Ibaraki Area. Glucose-non-fermentative Gram-negative bacilli isolated from the blood and the cerebrospinal fluid in independent cases between 2001 and 2014 were consecutively collected and those possibly to be Acinetobacter species were re-identified using molecular methods. Of 158 strains identified as Acinetobacter species, 155 were classified into 16 officially designated species, including 42 Acinetobacter pittii and 40 Acinetobacter baumannii. Imipenem non-susceptibility was detected only in 4 strains, none of which demonstrated multidrug resistance. Retrospective analyses of 154 cases for which medical records were fully available showed that the most common cause of infection was primary bloodstream infection (134 cases), of which 128 were related to intravascular catheter use. The mortality on day 28 after the onset was independently associated with cerebrovascular disease, moderate to severe renal disease, the Pitt bacteremia score, and infection other than primary bloodstream infection but not with appropriate empiric antimicrobial therapy. Isolation of A. baumannii was significantly associated with septic shock but not with the 28-day mortality. These findings, obtained in a region where drug-resistant Acinetobacter strains were much less prevailing, indicated that non-baumannii Acinetobacter species were common pathogens, that the most predominant cause of invasive Acinetobacter infection was intravascular catheter-related infection, that virulence of A. baumannii might be higher than those of other species but its association with mortality was unclear, and that administration of broad-spectrum antibiotics targeting Acinetobacter species might be deferrable in a certain situation.


Assuntos
Infecções por Acinetobacter/microbiologia , Acinetobacter/genética , Acinetobacter/isolamento & purificação , Infecções por Acinetobacter/tratamento farmacológico , Infecções por Acinetobacter/genética , Infecções por Acinetobacter/mortalidade , Acinetobacter baumannii/genética , Acinetobacter baumannii/isolamento & purificação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Bacteriemia/tratamento farmacológico , Bacteriemia/microbiologia , Infecções Relacionadas a Cateter/tratamento farmacológico , Infecções Relacionadas a Cateter/microbiologia , Criança , Pré-Escolar , Farmacorresistência Bacteriana , Feminino , Humanos , Imipenem/uso terapêutico , Lactente , Recém-Nascido , Japão , Masculino , Meningite/tratamento farmacológico , Meningite/microbiologia , Testes de Sensibilidade Microbiana , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Choque Séptico/tratamento farmacológico , Choque Séptico/microbiologia , Adulto Jovem
17.
J Infect Chemother ; 23(12): 833-836, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28803866

RESUMO

Campylobacter fetus is an organism residing primarily in the gastrointestinal tracts of cattle and sheep and transmitting to humans through ingestion of contaminated food products or surface water. The organism has caused various extraintestinal infections but, to date, purulent pericarditis due to the organism has rarely been described. We report a case of purulent pericarditis due to C. fetus subsp. fetus, occurring in a patient having several predisposing conditions, including receiving hemodialysis therapy, recent surgery for cecal cancer, and administration of esomeprazole. The patient mentioned having eaten homemade raw beef liver two weeks before the onset, suggesting that the ingested food product was contaminated with C. fetus and the organism transmitted to the pericardium through the bloodstream although blood culture was negative. The causative organism, recovered from the pericardial effusion, was unidentifiable with commercial systems but determinable with molecular methods at the subspecies level. The patient fully improved with pericardiocentesis and subsequent administration of ciprofloxacin, to which the organism was considered susceptible, for a total of four weeks. This is the first case of C. fetus pericarditis in which a history of ingesting a raw food product was clearly mentioned.


Assuntos
Infecções por Campylobacter/microbiologia , Campylobacter fetus/isolamento & purificação , Pericardite/microbiologia , Alimentos Crus/microbiologia , Animais , Antibacterianos/administração & dosagem , Sequência de Bases/genética , Infecções por Campylobacter/tratamento farmacológico , Campylobacter fetus/genética , Bovinos , Ciprofloxacina/administração & dosagem , Trato Gastrointestinal/microbiologia , Humanos , Fígado/microbiologia , Masculino , Pessoa de Meia-Idade , Pericardite/tratamento farmacológico , Pericárdio/microbiologia , Ovinos
18.
J Infect Chemother ; 18(2): 255-7, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21918819

RESUMO

A 49-year-old, human immunodeficiency virus-1-infected Asian woman developed Fanconi syndrome-like tubular acidosis while taking tenofovir disoproxil fumarate (TDF)/emtricitabine plus lopinavir/ritonavir for 9 months. All of her symptoms and abnormalities in laboratory tests resolved completely after switching TDF/emtricitabine to zidovudine and lamivudine. We consider that TDF caused symptomatic tubular acidosis in the present case, one of the few that has been reported in Japan to date.


Assuntos
Adenina/análogos & derivados , Fármacos Anti-HIV/efeitos adversos , Síndrome de Fanconi/induzido quimicamente , Infecções por HIV/tratamento farmacológico , Organofosfonatos/efeitos adversos , Inibidores da Transcriptase Reversa/efeitos adversos , Adenina/efeitos adversos , Adenina/uso terapêutico , Fármacos Anti-HIV/uso terapêutico , Terapia Antirretroviral de Alta Atividade , Desoxicitidina/análogos & derivados , Desoxicitidina/uso terapêutico , Quimioterapia Combinada , Emtricitabina , Feminino , Infecções por HIV/virologia , HIV-1/efeitos dos fármacos , Humanos , Pessoa de Meia-Idade , Organofosfonatos/uso terapêutico , Inibidores da Transcriptase Reversa/uso terapêutico , Tenofovir
19.
Proc Natl Acad Sci U S A ; 104(46): 18235-40, 2007 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-17991777

RESUMO

Influenza viruses infect vertebrates, including mammals and birds. Influenza virus reverse-genetics systems facilitate the study of the structure and function of viral factors. In contrast, less is known about host factors involved in the replication process. Here, we developed a replication and transcription system of the negative-strand RNA genome of the influenza virus in Saccharomyces cerevisiae, which depends on viral RNAs, viral RNA polymerases, and nucleoprotein (NP). Disruption of SUB2 encoding an orthologue of human RAF-2p48/UAP56, a previously identified viral RNA synthesis stimulatory host factor, resulted in reduction of the viral RNA synthesis rate. Using a genome-wide set of yeast single-gene deletion strains, we found several host factor candidates affecting viral RNA synthesis. We found that among them, Tat-SF1, a mammalian homologue of yeast CUS2, was a stimulatory host factor in influenza virus RNA synthesis. Tat-SF1 interacted with free NP, but not with NP associated with RNA, and facilitated formation of RNA-NP complexes. These results suggest that Tat-SF1 may function as a molecular chaperone for NP, as does RAF-2p48/UAP56. This system has proven useful for further studies on the mechanism of influenza virus genome replication and transcription.


Assuntos
Orthomyxoviridae/genética , RNA Viral/biossíntese , Replicon , Saccharomyces cerevisiae/genética , Transativadores/genética , Genoma Viral , Humanos , Orthomyxoviridae/fisiologia , Replicação Viral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA