Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Int J Cardiovasc Imaging ; 40(4): 733-743, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38289428

RESUMO

BACKGROUND: Mitral annular calcification (MAC) poses many challenges to the evaluation of diastolic function using standard echocardiography. Left atrial (LA) strain and left ventricular early diastolic strain rate (DSr) measured by speckle-tracking echocardiography (STE) are emerging techniques in the noninvasive evaluation of diastolic function. We aim to evaluate the utility of LA strain and early DSr in predicting elevated left ventricular filling pressures (LVFP) in patients with MAC and compare their effectiveness to ratio of mitral inflow velocity in early and late diastole (E/A). METHODS: We included adult patients with MAC who presented between January 1 and December 31, 2014 and received a transthoracic echocardiogram (TTE) and cardiac catheterization with measurement of LVFP within a 24-h period. We used Spearman's rank correlation coefficient to assess associations of LA reservoir strain and average early DSr with LVFP. Receiver operating characteristic (ROC) curves were computed to assess the effectiveness of LA strain and DSr in discriminating elevated LVFP as a dichotomized variable and to compare their effectiveness with E/A ratio categorized according to grade of diastolic dysfunction. RESULTS: Fifty-five patients were included. LA reservoir strain demonstrated poor correlation with LVFP (Spearman's rho = 0.03, p = 0.81) and poor discriminatory ability for detecting elevated LVFP (AUC = 0.54, 95% CI 0.38-0.69). Categorical E/A ratio alone also demonstrated poor discriminatory ability (AUC = 0.53, 95% CI 0.39-0.67), and addition of LA reservoir strain did not significantly improve effectiveness (AUC = 0.58, 95% CI 0.42-0.74, p = 0.56). Average early DSr also demonstrated poor correlation with LVFP (Spearman's rho = -0.19, p = 0.16) and poor discriminatory ability for detecting elevated LVFP (AUC = 0.59, 95% CI 0.44-0.75). Addition of average early DSr to categorical E/A ratio failed to improve effectiveness (AUC = 0.62, 95% CI 0.46-0.77 vs. AUC = 0.54, 95% CI 0.39-0.69, p = 0.38). CONCLUSIONS: In our sample, LA reservoir strain and DSr do not accurately predict diastolic filling pressure. Further research is required before LA strain and early DSr can be routinely used in clinical practice to assess filling pressure in patients with MAC.


Assuntos
Função do Átrio Esquerdo , Calcinose , Diástole , Valva Mitral , Valor Preditivo dos Testes , Disfunção Ventricular Esquerda , Função Ventricular Esquerda , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Valva Mitral/diagnóstico por imagem , Idoso , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Calcinose/fisiopatologia , Calcinose/diagnóstico por imagem , Reprodutibilidade dos Testes , Pressão Ventricular , Cateterismo Cardíaco , Doenças das Valvas Cardíacas/fisiopatologia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/complicações , Área Sob a Curva , Estudos Retrospectivos , Fenômenos Biomecânicos , Ecocardiografia Doppler
2.
J Ultrasound Med ; 41(12): 2939-2953, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35305032

RESUMO

OBJECTIVES: One of the problems for the clinician who desires to measure the interventricular septum (IVS) in a high-risk fetus is to know where to make the measurement. The purpose of this study was to use speckle-tracking analysis to measure the IVS area, 24-segment widths, and length at end-diastole (ED) and end-systole (ES) in normal fetuses. METHODS: From the 4-chamber view, speckle-tracking analysis was performed at ED and ES on the IVS in 200 normal fetuses. The following were computed and regressed against gestational age (GA) and fetal biometric (FB) measurements: area, length, and the 24-segment transverse widths from the apex to the crux. The 24-segment width/length ratio was also measured. The speckle-tracking measurements of the ED area and length were compared using a point-to-point measurement tool available on all ultrasound machines. RESULTS: The ED and ES areas, lengths, and 24-segment widths increased with GA and FB. The ED and ES areas were virtually identical. The 24-segment width/length ratio decreased from the apex to the crux of the septum. There was no significant difference in the measurement of the ED area and the length between speckle-tracking and the point-to-point measurements. CONCLUSIONS: Measurement of the area and length of the IVS are simple to obtain and provide a new diagnostic tool to evaluate the fetus at risk for IVS hypertrophy which may be observed in fetuses of mothers with pregestational and gestational diabetes.


Assuntos
Coração Fetal , Septo Interventricular , Feminino , Gravidez , Humanos , Coração Fetal/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Septo Interventricular/diagnóstico por imagem , Idade Gestacional , Hipertrofia , Ventrículos do Coração/diagnóstico por imagem
3.
J Ultrasound Med ; 41(8): 2041-2057, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34825711

RESUMO

OBJECTIVES: The purpose of this study was to use speckle tracking analysis to evaluate the size, shape, and function of the atrial chambers in normal fetuses and develop a z-score calculator that can be used in future studies in fetuses at risk for cardiovascular disease. METHODS: The control group consisted of 200 normal fetuses examined between 20 and 40 weeks of gestation in which speckle tracking analysis of right (RA) and left (LA) atrial chambers was performed. The atrial end-diastolic and end-systolic endocardial borders for each chamber were identified from which measurements of atrial length, width, area, and volume were computed. Equations were derived using fractional polynomial regression analysis to compute z-score equations. RESULTS: The LA end-diastolic volume, RA and LA end-diastolic area, length, base width, and mid-chamber widths increased with gestational age and fetal size. Left atrial emptying and ejection volumes increased with gestational age and fetal size. The fractional area change was significantly less for the RA than the LA. The LA base and mid-chamber fractional shortening were significantly greater than the RA. There was a significant difference between the RA and LA global contractile strain. CONCLUSION: Mean and standard deviation equations for each of the measurements described in this study were computed to create a z-score calculator that can be utilized in the clinical environment when evaluating fetuses with suspected atrial pathology that could alter the size, shape, and function of the atrial chambers.


Assuntos
Átrios do Coração , Ultrassonografia Pré-Natal , Diástole , Feminino , Feto , Idade Gestacional , Átrios do Coração/diagnóstico por imagem , Humanos , Gravidez
4.
Echocardiography ; 37(7): 1021-1029, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32562443

RESUMO

BACKGROUND: Atrial function has a close interdependence with ventricular function and plays a central role in maintaining optimal cardiac function. There are two well-defined timing methods used to determine the start point. The aim of this prospective study was to objectively assess the influence of gating method selection on reported left and right strain values within the same group of healthy subjects. METHODS: 101 volunteers (44 male, 57 female) had adequate tracking for analysis on TomTec Imaging Systems (Unterschleissheim, Germany). The median age was 41 years (range 19-79 years, interquartile range 30-52 years). Atrial strain by 2D-speckle tracking echocardiography was evaluated using two commonly applied zero baseline time reference methods: R-R gating and P-P gating, in addition to volume gating (defining end-systole at the atrial maximum and end-diastole at the atrial minimum). RESULTS: True atrial minimum occurred prior to the onset of the QRS in most healthy volunteers. There was a significant difference for LA and RA reservoir strain between volume gating and R-R gating (mean difference, 4.63%; P < .001 for LA; mean difference, 4.23%; P < .001 for RA), as well as volume gating and P-P gating (mean difference, 5.26%; P < .001 for LA; mean difference, 6.24%; P < .001 for RA). Noticeably, reservoir strain was comparable between R-R gating and P-P gating (mean difference, 0.58%, P = .06) in LA, but not on RA (mean difference, 2.02%, P < .001). CONCLUSIONS: There was variability in atrial strain values depending on the zero baseline time reference method used.


Assuntos
Função do Átrio Esquerdo , Átrios do Coração , Adulto , Idoso , Ecocardiografia , Feminino , Alemanha , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
5.
Circ J ; 84(2): 235-244, 2020 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-31932561

RESUMO

BACKGROUND: Right ventricular (RV) volumetric and functional assessments are both crucial for the management of patients with hypoplastic left heart syndrome (HLHS). 3-dimensional echocardiography (3DE) for volume measurements and 2D speckle-tracking echocardiography (2D-STE) for strain analysis are performed separately. 3D-STE is capable of evaluating those parameters simultaneously and providing principal strain (PS), unifying the concepts of myofiber orientation and contraction into a single, maximal contractile direction. However, the application of 3D-STE to HLHS has not been studied and so became the aim of our study.Methods and Results:64 HLHS patients after Fontan palliation underwent 3D-STE analysis measuring RV end-diastolic volume index (EDVi), ejection fraction (EF), global PS (GPS), global circumferential strain (GCS), and global longitudinal strain (GLS). Volume measurements were compared between 3D-STE and 3DE, and strains were compared between 3D- and 2D-STE. EDVi and EF showed strong correlations between 3D-STE and 3DE (r=0.93 and 0.87, respectively). GCS and GLS showed moderate correlations between 3D- and 2D-STE (r=0.65 and 0.61, respectively). GPS showed highest magnitude and excellent correlation with EF (r=-0.95). CONCLUSIONS: Simultaneous volumetric and functional assessment by 3D-STE was a useful method in this HLHS cohort. PS is a promising parameter for evaluating the RV function of HLHS, which could be useful during longitudinal follow-up.


Assuntos
Ecocardiografia Tridimensional , Técnica de Fontan , Ventrículos do Coração/cirurgia , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Cuidados Paliativos , Função Ventricular Direita , Adolescente , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Ventrículos do Coração/anormalidades , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico por imagem , Síndrome do Coração Esquerdo Hipoplásico/fisiopatologia , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento
6.
Echocardiography ; 36(8): 1581-1585, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31393624

RESUMO

Massive and submassive pulmonary thromboembolism carry significant morbidity and mortality. We present an elderly female who was diagnosed with a submassive pulmonary embolism by computed tomographic angiography and treated with ultrasound-facilitated thrombolysis (UFT). This case demonstrates the usefulness of right ventricular longitudinal strain measurements by two-dimensional speckle tracking echocardiography in the evaluation of right ventricular function before and after UFT. Evaluation of right ventricle longitudinal strain by speckle tracking echocardiography may supplement other parameters in the assessment of right ventricular function in these patients.


Assuntos
Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico , Terapia Assistida por Computador/métodos , Terapia Trombolítica/métodos , Ativador de Plasminogênio Tecidual/uso terapêutico , Ultrassonografia/métodos , Angiografia por Tomografia Computadorizada , Ecocardiografia , Feminino , Fibrinolíticos/uso terapêutico , Humanos , Pessoa de Meia-Idade , Embolia Pulmonar/tratamento farmacológico
7.
J Ultrasound Med ; 38(5): 1209-1221, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30244474

RESUMO

OBJECTIVES: This study was conducted to evaluate left ventricular (LV) size and function in healthy fetuses and to test a cohort of fetuses at risk for abnormal function using speckle-tracking software. METHODS: Two hundred control fetuses were examined between 20 and 40 weeks' gestation. With the use of offline speckle-tracking software, the end-diastolic and end-systolic volumes were measured and the following computed: stroke volume (SV), SV per kilogram, cardiac output (CO), CO per kilogram, and ejection fraction. These were regressed against 7 independent variables related to the size, weight, and age of the fetuses. Five fetuses with risk factors for LV dysfunction were examined to sample the validity of the data from the control group. RESULTS: The R2 values for measurements of the end-diastolic volume, SV, and CO correlated with the 7 independent variables of fetal size and age (0.7-0.78), whereas the SV/kg, CO/kg, and ejection fraction had lower R2 values (0.02-0.1). The measurements were normally distributed (Shapiro-Wilke > 0.5). The 5 fetuses at risk for abnormal LV function had measurements of LV size and function that were consistent with the expected pathologic condition. CONCLUSIONS: Speckle tracking can provide a comprehensive evaluation of the size and function of the fetal LV.


Assuntos
Ecocardiografia/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Ultrassonografia Pré-Natal/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/embriologia , Estudos de Coortes , Estudos Transversais , Feminino , Coração Fetal/diagnóstico por imagem , Coração Fetal/patologia , Coração Fetal/fisiopatologia , Cardiopatias Congênitas/patologia , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/embriologia , Ventrículos do Coração/patologia , Humanos , Tamanho do Órgão , Gravidez , Estudos Prospectivos , Fatores de Risco , Disfunção Ventricular Esquerda/patologia
8.
J Ultrasound Med ; 38(4): 1039-1047, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30280404

RESUMO

INTRODUCTION: This study was conducted to evaluate the 24-segment transverse widths of the right and left ventricles distributed from the base to the apex of the ventricular chambers and compute the right ventricular (RV)/left ventricular (LV) ratios for each segment. METHODS: Two hundred control fetuses were examined between 20 and 40 weeks' gestation. Using offline speckle-tracking software, the 24 end-diastolic transverse widths were computed and the RV/LV ratios were regressed against 7 independent variables related to the size, weight, and age of the fetuses. Five fetuses with coarctation of the aorta and 5 fetuses with pulmonary stenosis were examined to exemplify the utility of these measurements. FINDINGS: The 24-segment transverse widths were associated with changes in fetal size, weight, and age. Regression equations were developed to describe these changes with R2 values between .5 and .82. The measurements were normally distributed (Shapiro-Wilk > 0.5). The RV/LV ratio for the 24 segments did not strongly correlate (R2 = .001 to -.2) with fetal size, weight, or gestational age. Fetuses with coarctation of the aorta and pulmonary stenosis demonstrated characteristic changes in the 24-segment transverse widths and the RV/LV ratios in the basal (segments 1-8), mid (segments 9-16) and apical (segments 17-24) sections of the ventricles. CONCLUSIONS: The 24-segment transverse widths of the right and left ventricles and the RV/LV ratios provide a comprehensive method to examine the width of the ventricular chambers.


Assuntos
Ecocardiografia/métodos , Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Feminino , Coração Fetal/embriologia , Coração Fetal/fisiopatologia , Cardiopatias Congênitas/embriologia , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/embriologia , Ventrículos do Coração/fisiopatologia , Humanos , Gravidez
9.
J Ultrasound Med ; 38(5): 1309-1318, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30208238

RESUMO

OBJECTIVE: Annular plane systolic excursion (APSE) has been evaluated for the right (RV) and left (LV) ventricles using M-mode echocardiography. This study examined APSE using 2-dimensional speckle tracking (2DST) of the lateral and septal annuli of the RV and LV in normal fetuses. METHODS: Two hundred normal fetuses were prospectively examined between 20 and 40 weeks' gestation, in which the end-diastolic and end-systolic lengths were measured from the apex to the insertion of the annuli into the lateral and septal walls of the RV and LV using 2DST. Subtracting the end-systolic from the end-diastolic length resulted in the APSE measurement. The APSE values from the ventricular and septal locations were regressed against biometric and gestational age independent variables, and the mean and standard deviation computed using fractional polynomial analysis. Within-subject repeated measures of variance were used to compare results within and between the right ventricular and left ventricular basal APSE values. RESULTS: When regressed against the independent variables the R2 for the APSE of the right ventricular lateral wall ranged from 0.39 to 0.40, the left ventricular lateral wall 0.29 to 0.31, the right ventricular septal wall 0.22 to 0.40, and the left ventricular septal wall 0.05 to 0.07. There was a significant difference (P < .001) for APSE between the right ventricular and left ventricular lateral wall and their respective septal annuli, the left ventricular and right ventricular lateral wall annuli, and the left ventricular and right ventricular septal annuli. CONCLUSIONS: The right ventricular and left ventricular lateral and septal wall APSE can be computed using 2DST and are associated with changing fetal biometric and age measurements.


Assuntos
Ecocardiografia/métodos , Ventrículos do Coração/embriologia , Função Ventricular/fisiologia , Feminino , Coração Fetal/embriologia , Coração Fetal/fisiologia , Idade Gestacional , Humanos , Gravidez , Estudos Prospectivos , Sístole
10.
Echocardiography ; 36(1): 150-163, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30592784

RESUMO

The usefulness of two-dimensional transthoracic echocardiography (2DTTE) in the assessment of right heart compression and dysfunction produced by pectus excavatum chest wall deformity has been well described in the literature by several investigators. However, there is a paucity of reports describing incremental value of live/real time three-dimensional transthoracic echocardiography (3DTTE) over the two-dimensional technique in the evaluation of right heart function in these patients. We present a severe case of pectus excavatum chest wall deformity in a young male, in whom 3DTTE provided incremental value over standard 2DTTE in assessing compression of the right heart before surgery and marked improvement in right heart function parameters following surgical repair. In addition, an updated summary of salient features of this deformity, including 2D and 3DTTE findings as well as right heart echocardiographic parameters by both 2D and 3DTTE in normal/healthy subjects summarized from the literature have been provided in a tabular form for comparison.


Assuntos
Ecocardiografia Tridimensional/métodos , Tórax em Funil/complicações , Disfunção Ventricular Direita/etiologia , Adulto , Ecocardiografia/métodos , Tórax em Funil/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Disfunção Ventricular Direita/cirurgia , Adulto Jovem
11.
Pediatr Cardiol ; 39(6): 1172-1180, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29644405

RESUMO

Left ventricular (LV) dysfunction is a risk factor for adverse outcomes in older children and adults with repaired Tetralogy of Fallot (rToF). Pulmonary regurgitation (PR), right ventricular (RV) dilation, and dysfunction have been shown to result in abnormal LV myocardial mechanics and dysfunction. The aim of our study was to evaluate LV rotational mechanics, especially apical rotation in young children with rToF with and without RV dilation. This is a retrospective, single center study in 28 asymptomatic young children with rToF (16 with RV dilation; 12 without RV dilation); 29 age-matched normal controls. RV and LV systolic and diastolic function was studied using conventional two-dimensional echocardiography (2DE) and speckle tracking echocardiography (STE). Rotational mechanics studied included basal and apical rotation (BR, AR), peak twist (calculated by difference between the apical and basal rotation), twist rate (TR), and untwist rate (UnTR). The mean age of the cohort was 4.7 years (± 2.3). Abnormal AR, BR, TR, and UnTR were noted in patients with rToF. The abnormalities were significant in magnitude as well as the direction of rotation; more pronounced in the absence of RV dilation. LV systolic and diastolic dysfunction as evidenced by abnormal AR and degree of untwist is inherent in rToF and not associated with RV dilation in rToF children. Abnormal BR may reflect a lack of maturation to adult type of rotational mechanics. Further longitudinal studies are required to study the progression of these abnormalities and their correlation with clinical outcomes.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ventrículos do Coração/fisiopatologia , Tetralogia de Fallot/cirurgia , Disfunção Ventricular/fisiopatologia , Criança , Pré-Escolar , Estudos Transversais , Ecocardiografia/métodos , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Insuficiência da Valva Pulmonar/fisiopatologia , Estudos Retrospectivos , Fatores de Risco , Rotação , Tetralogia de Fallot/complicações , Função Ventricular/fisiologia
12.
J Ultrasound Med ; 37(5): 1129-1141, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29068072

RESUMO

OBJECTIVES: Because of various fetal and maternal disease states, this study was conducted to evaluate the fractional shortening of 24 transverse segments distributed from the base to the apex of the ventricular chambers. METHODS: Two hundred control fetuses were examined between 20 and 40 weeks' gestation. The transverse displacement of the ventricular endocardium during the cardiac cycle was computed by using offline software. From the output of the analysis, 24 end-diastolic and end-systolic segments were measured from the base (segment 1) to the apex (segment 24) of the right and left ventricles, and the fractional shortening was computed: [(end-diastolic length - end-systolic length)/end-diastolic length] × 100. Examples of fetal cardiovascular abnormalities were selected to demonstrate the utility of this technique. RESULTS: The fractional shortening for each segment was independent of gestational age and fetal biometric measurements. There was no significant difference in fractional shortening for segments 1 to 5 between the right and left ventricles. However, the fractional shortening of the left ventricle was significantly greater (P < .0001) than that of the right ventricle for segments 6 to 24, suggesting that the mid and apical segments of the left ventricle have increased displacement toward the center of the chamber compared to the right ventricle. Fetuses with various cardiac structural abnormalities had abnormal fractional shortening values. CONCLUSIONS: The fractional shortening of 24 segments of the right and left ventricles provides a comprehensive method to examine the contractility of the ventricular chambers.


Assuntos
Ecocardiografia/métodos , Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Ultrassonografia Pré-Natal/métodos , Feminino , Coração Fetal/fisiopatologia , Ventrículos do Coração/embriologia , Ventrículos do Coração/fisiopatologia , Humanos , Contração Miocárdica/fisiologia , Gravidez
13.
J Ultrasound Med ; 37(5): 1159-1171, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29086430

RESUMO

OBJECTIVES: The purpose of this study was to compare a new technique that measures the midventricular basal-apical longitudinal diastolic and systolic lengths, computes the longitudinal displacement fractional shortening, and compares it to global strain. METHODS: Two hundred control fetuses were examined between 20 and 40 weeks' gestation, in whom the longitudinal displacement fractional shortening was computed from end-diastolic and end-systolic lengths measured from the apex to the mid portion of the distance between the level of the basal lateral and septal walls using 2-dimnsional speckle tracking. In addition, global strain was computed using speckle tracking. A correlation analysis was used to compare the longitudinal displacement fractional shortening to global strain. The longitudinal displacement fractional shortening of the right ventricle (RV) and left ventricle (LV) was measured in 10 fetuses with heart abnormalities. RESULTS: The longitudinal displacement fractional shortening for the RV (mean ± SD, 22.94% ± 4.73%) and LV (21.05% ± 4.21%) was independent of gestational age and other biometric growth parameters, as was global strain (RV, -22.7% ± 4.07%); LV, -22.93% ± 3.52%). The RV longitudinal displacement fractional shortening was greater than that of the LV (P < .024). The correlations between the longitudinal displacement fractional shortening and global strain were 0.95 for the RV and 0.97 for the LV. Comparing the longitudinal displacement fractional shortening and global strain in fetuses with abnormal cardiac findings showed concordant findings in 9 of 10 fetuses. CONCLUSIONS: The RV and LV longitudinal displacement fractional shortening can be computed from 2-dimensional images of the 4-chamber view and correlated with global strain. The longitudinal displacement fractional shortening was significantly greater for the RV than the LV and was abnormal in fetuses with RV and LV cardiac abnormalities.


Assuntos
Ecocardiografia/métodos , Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Ultrassonografia Pré-Natal/métodos , Disfunção Ventricular/diagnóstico por imagem , Diástole , Feminino , Coração Fetal/fisiopatologia , Cardiopatias Congênitas/embriologia , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Gravidez , Sístole , Disfunção Ventricular/embriologia , Disfunção Ventricular/fisiopatologia
14.
Prenat Diagn ; 37(12): 1203-1212, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29023931

RESUMO

INTRODUCTION: The purpose of this study was to simultaneously measure with speckle tracking software the end-diastolic ventricular area (A), basal transverse width (BW), mid-chamber transverse width (MW), and basal-apical length (BAL) in normal fetuses and those with pathology. METHODS: The 4-chamber view of the fetal heart was obtained in 200 control fetuses between 20 and 40 weeks of gestation and in 9 third-trimester fetuses with heart malformations. The mean and standard deviation for the A, BW, MW, and BAL were computed from the control fetuses and Z scores computed from the 9 fetuses with cardiac malformations. RESULTS: The A, BAL, BW, and MW were correlated with 7 somatic and age-independent variables (R2  = .63-.85). The highest R2 values occurred for the head circumference, estimated fetal weight, and ultrasound mean gestational age (.82-.85). Z-score values and centiles from the 9 fetuses with cardiac malformations suggested that the A, BW, MW, and BAL were below or above the 5th and 95th centiles as expected for the corresponding ventricular pathology. CONCLUSIONS: This study reports an integrated approach to evaluate the end-diastolic size of the right and left ventricular chambers and demonstrated clinical utility in fetuses with cardiac malformations.


Assuntos
Técnicas de Imagem Cardíaca , Cardiopatias Congênitas/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Adulto , Estudos de Casos e Controles , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Gravidez , Valores de Referência
15.
J Am Soc Echocardiogr ; 30(8): 773-780.e1, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28599825

RESUMO

BACKGROUND: The authors investigated left ventricular (LV) rotational indices, twist, and torsion in a large cohort of fetuses using two-dimensional speckle-tracking echocardiography. METHODS: Pregnant women (N = 102) were prospectively recruited for fetal two-dimensional speckle-tracking echocardiography. Because of variable fetal position, ventricular orientation was established using the location of the liver and LV position in relation to the right ventricle. Twist measurements required correction to account for fetal position, reconciling directionality across all fetal orientations. Peak apical and basal rotations, global longitudinal strain, global circumferential strain (GCS), longitudinal strain rate, circumferential strain rate (CSR), twist, and torsion were reported and tested for associations with gestational age (GA) and estimated fetal weight (EFW). RESULTS: Measurement of rotational indices was feasible in 175 examinations (73%). The mean maternal age was 31 ± 6 years, the mean GA 24 ± 6 weeks, and the EFW 1.0 ± 1.0 kg. Mean peak apical rotation, basal rotation, twist, and torsion were 9.5 ± 2.0°, -4.4 ± 1.1°, 13.1 ± 2.3°, and 7.9 ± 3.4°/cm, respectively. Mean global longitudinal strain, GCS, longitudinal strain rate, and CSR were -22.3 ± 4.3%, -25.0 ± 6.1%, -1.4 ± 0.5 sec-1, and -1.6 ± 0.5 sec-1, respectively. Absolute GCS, CSR, apical rotation, and twist declined moderately with GA and EFW (P < .05). There were strong negative nonlinear correlations of torsion with GA and EFW: torsion = 1,104 × GA-1.591 (r2 = 0.760, P < .001); torsion = 115.88 × EFW-0.427 (r2 = 0.772, P < .001). CONCLUSIONS: Determination of fetal LV rotational mechanics is feasible and reproducible using two-dimensional speckle-tracking echocardiography. Basal rotation, longitudinal strain, and strain rate vary little with EFW and GA. Interpretation of LV apical rotation, twist, torsion, GCS, and CSR, however, must take GA or EFW into account. These data form the basis for comparison with findings in fetuses with abnormal cardiac anatomy and function.


Assuntos
Ecocardiografia/métodos , Coração Fetal/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Anormalidade Torcional/diagnóstico , Ultrassonografia Pré-Natal/métodos , Função Ventricular Esquerda/fisiologia , Adulto , Feminino , Coração Fetal/embriologia , Seguimentos , Idade Gestacional , Ventrículos do Coração/embriologia , Humanos , Gravidez , Curva ROC , Reprodutibilidade dos Testes , Anormalidade Torcional/embriologia , Adulto Jovem
16.
J Am Soc Echocardiogr ; 29(2): 119-31, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26678319

RESUMO

BACKGROUND: Cardiac magnetic resonance imaging (CMR) is the gold standard for the quantification of global and regional myocardial function and can detect subclinical myocardial dysfunction in anthracycline-induced cardiomyopathy. The aim of this study was to ascertain reliable echocardiographic parameters that can be used for the early identification of cancer therapeutics-related cardiac dysfunction, compared with CMR. METHODS: Fifty-seven pediatric cancer survivors, 10 to 42 years of age, with cumulative anthracycline doses ≥ 200 mg/m(2), were studied with transthoracic echocardiography and CMR 2.4 to 26.9 years after chemotherapy. RESULTS: Three-dimensional echocardiography had the highest sensitivity in identifying subjects with CMR-derived ejection fractions < 55%. Subjects with end-systolic volume index values > 29 mL/m(2) were more likely to have CMR-derived ejection fractions < 55%. Three-dimensional speckle-tracking echocardiographic peak global longitudinal strain magnitude < -17.5% best identified subjects with abnormal peak midwall longitudinal strain magnitude by CMR. A decrease in early atrial myocardial velocity of <10 cm/sec at the interventricular septum also identified subjects with lower average peak midwall longitudinal strain and peak midwall circumferential strain magnitudes by CMR. CONCLUSIONS: Three-dimensional echocardiographic ejection fraction < 55%, end-systolic volume index > 29 mL/m(2), three-dimensional speckle-tracking echocardiographic peak global longitudinal strain magnitude < -17.5%, and a decrease in early atrial myocardial velocity at the interventricular septum of <10 cm/sec by Doppler tissue imaging are the most sensitive transthoracic echocardiographic parameters to identify subjects with subclinical myocardial dysfunction by CMR.


Assuntos
Antraciclinas/efeitos adversos , Antineoplásicos/efeitos adversos , Cardiopatias/induzido quimicamente , Cardiopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Antraciclinas/administração & dosagem , Antineoplásicos/administração & dosagem , Criança , Ecocardiografia Tridimensional , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Estudos Prospectivos
17.
J Am Soc Echocardiogr ; 28(10): 1161-1170, e2, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26123011

RESUMO

BACKGROUND: Clinical experience suggests that measurement of left ventricular (LV) ejection fraction (EF) using two-dimensional echocardiography (2DE) is often at variance with results of three-dimensional echocardiography (3DE) in patients who have undergone heart transplantation (HT). The aim of this study was to test the hypothesis that LV mechanical dyssynchrony and abnormal regional strain are present in asymptomatic pediatric HT patients and that they promote errors in the measurement of LV function when 2DE is used. METHODS: HT subjects and normal volunteer children were prospectively enrolled. All had normal estimated right ventricular systolic pressure and function. LV EF, global and regional strain, and systolic dyssynchrony index (SDI) were quantified using real time 3DE. SDI was determined from volume-time curves of the 16 LV segments and expressed as the standard deviation of the heart rate-corrected time to reach minimal segmental systolic volume. Septal strain was defined as the average of five segments in the interventricular septum. In addition to 3DE, the Teichholz, biplane Simpson, and bullet (5/6 area-length) methods were used to measure EF using 2DE in each subject. Ninety-three examinations were done: 40 in the 40 normal control subjects (mean age, 14.6 ± 10.6 years; 10 male) and 53 in 36 HT subjects (mean age, 10.3 ± 6.2 years; 21 male). RESULTS: SDI was greater in HT patients (mean, 6.2 ± 4.3%) than in normal controls (mean, 2.2 ± 1.1%) (P < .0001). Global and septal strain was lower in HT patients than in normal controls. EF divergence (absolute difference between two- and three-dimensional EFs) was greater in HT patients (mean, 3.8 ± 2.2%) than in normal controls (mean, 0.7 ± 0.5%) (P < .0001). EF divergence had a strong positive correlation with SDI (adjusted r² = 0.46, P < .001) and negative correlations with all measures of strain (range of adjusted r² values, 0.13-0.32). SDI had no particular relation to LV mass or to QRS duration. CONCLUSIONS: Children after HT have abnormal LV mechanics characterized by greater dyssynchrony and lower strain. These features correlate with, and possibly contribute to differences between measurements by 2DE and 3DE. EF should be calculated using 3DE in this population and others with dyssynchrony and regional strain abnormalities.


Assuntos
Ecocardiografia Tridimensional , Transplante de Coração/métodos , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adolescente , Estudos de Casos e Controles , Criança , Pré-Escolar , Ecocardiografia/métodos , Feminino , Seguimentos , Rejeição de Enxerto/diagnóstico por imagem , Rejeição de Enxerto/epidemiologia , Transplante de Coração/efeitos adversos , Humanos , Masculino , Variações Dependentes do Observador , Pediatria , Estudos Prospectivos , Valores de Referência , Análise de Regressão , Medição de Risco , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Sístole/fisiologia , Disfunção Ventricular Esquerda/fisiopatologia
18.
Echocardiography ; 32(5): 848-54, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25827179

RESUMO

We report a case of a right atrial thrombus traversing a patent foramen ovale into the left atrium, where three-dimensional transesophageal echocardiography provided considerable incremental value over two-dimensional transesophageal echocardiography in its assessment. As well as allowing us to better spatially characterize the thrombus, three-dimensional transesophageal echocardiography provided a more quantitative assessment through estimation of total thrombus burden.


Assuntos
Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Forame Oval Patente/complicações , Cardiopatias/diagnóstico por imagem , Trombose/complicações , Trombose/diagnóstico por imagem , Idoso , Feminino , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/cirurgia , Cardiopatias/complicações , Cardiopatias/cirurgia , Humanos , Trombose/cirurgia
19.
J Am Soc Echocardiogr ; 26(11): 1282-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24044977

RESUMO

BACKGROUND: Contrast echocardiography (CE) provides closer agreement with magnetic resonance imaging (MRI) for left ventricular (LV) volumes and ejection fraction (EF) than noncontrast echocardiography. However, the feasibility and role of myocardial deformation analysis on contrast echocardiographic images have not been well established. The aim of this study was to assess the feasibility of deformation analysis on CE using a new software tool that provides simultaneous measurements for LV volumes and EF. METHODS: Data from 52 patients who were recruited for the Alberta Heart Failure Etiology and Analysis Research Team Study (34 men; mean age, 64 ± 9 years) and underwent CE and MRI were considered. Contrast bolus injections were administered for optimal endocardial definition. Offline LV volume analysis was performed by standard manual tracing. A single frame was traced manually for two-dimensional (2D) cardiac performance analysis (CPA), which automatically calculated LV volumes, EF, and global longitudinal strain (GLS). Volumes obtained with 2D CPA were compared with those measured with standard CE and MRI. GLS from noncontrast echocardiographic recordings was also calculated with 2D CPA and compared with CE-derived and MRI-derived GLS. RESULTS: Tracing of contrast echocardiographic images with 2D CPA was possible in 49 out of 52 patients, and measurements correlated well with standard CE and MRI (EF: r = 0.93, P < .001, and r = 0.85, P < .001, respectively). Mean GLS from noncontrast echocardiographic and contrast echocardiographic recordings was -13.4 ± 5.8 and -15.3 ± 4.64, respectively (P = .056), and the latter correlated well with MRI-derived GLS (r = 0.78 vs 0.81, respectively). CONCLUSIONS: Simultaneous volumetric and deformation analysis on contrast echocardiographic recordings is feasible and reproducible. While volumes and EF obtained with the new software compare well with those obtained from standard CE and MRI, GLS from CE shows a good correlation with strain measured with MRI.


Assuntos
Ecocardiografia/métodos , Técnicas de Imagem por Elasticidade/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Idoso , Meios de Contraste , Módulo de Elasticidade , Feminino , Dureza , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
J Am Soc Echocardiogr ; 26(8): 853-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23791113

RESUMO

BACKGROUND: Three-dimensional (3D) strain analysis may help overcome the limitations of Doppler and two-dimensional strain analysis for the left ventricle and become the method of choice for left ventricular (LV) systolic function. The aims of this study were to evaluate the feasibility and reproducibility of LV global 3D systolic strain by real-time 3D speckle-tracking echocardiography (STE) in children and to establish their maturational growth patterns and normal values. METHODS: A prospective study was conducted in 256 consecutive healthy subjects using real-time 3D echocardiography. Full-volume 3D data were acquired using a 3D matrix-array transducer. Three-dimensional LV peak systolic global strain (GS), global longitudinal strain (GLS), global radial strain (GRS), and global circumferential strain (GCS) values were determined using real-time 3D STE. RESULTS: A total of 228 patients (89%) met the criteria for analysis; 28 (11%) were excluded. The correlations between age and strain variables by real-time 3D STE were poor (R(2) = 0.01-0.05, P < .05). The differences in GLS and GCS among the five age groups were statistically significant but clinically irrelevant. There were no statistical differences in GRS and GS values among the age groups, nor were there statistical differences between the genders for all 3D strain parameters. Intraobserver and interobserver variability ranged from 5.0 ± 4.3% to 10.1 ± 8.5% versus 6.9 ± 6.1% to 17.0 ± 16.2% for coefficients of variation, respectively. Interclass correlation coefficients ranged from 0.78 to 0.87 and from 0.75 to 0.79 for intraobserver and interobserver measurements for GS, GLS, GCS, and GRS, respectively. CONCLUSIONS: LV global 3D systolic strain analysis using the new 3D STE is feasible and reproducible in the pediatric population. There are small maturational changes in GLS and GCS, but not in GRS and GS, that are statistically significant but probably clinically irrelevant. Further investigation is warranted for potential clinical application of this new technology in a pediatric population.


Assuntos
Envelhecimento/fisiologia , Ecocardiografia Tridimensional/estatística & dados numéricos , Técnicas de Imagem por Elasticidade/estatística & dados numéricos , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia , Adolescente , Distribuição por Idade , Criança , Pré-Escolar , China/epidemiologia , Sistemas Computacionais , Ecocardiografia Tridimensional/normas , Módulo de Elasticidade , Estudos de Viabilidade , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Variações Dependentes do Observador , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA