Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Burns ; 42(2): 329-35, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26839051

RESUMO

OBJECTIVE: The aim of this study was to compare the accuracy of burn size estimation using the computer-assisted software BurnCase 3D (RISC Software GmbH, Hagenberg, Austria) with that using a 2D scan, considered to be the actual burn size. METHODS: Thirty artificial burn areas were pre planned and prepared on three mannequins (one child, one female, and one male). Five trained physicians (raters) were asked to assess the size of all wound areas using BurnCase 3D software. The results were then compared with the real wound areas, as determined by 2D planimetry imaging. To examine inter-rater reliability, we performed an intraclass correlation analysis with a 95% confidence interval. RESULTS: The mean wound area estimations of the five raters using BurnCase 3D were in total 20.7±0.9% for the child, 27.2±1.5% for the female and 16.5±0.1% for the male mannequin. Our analysis showed relative overestimations of 0.4%, 2.8% and 1.5% for the child, female and male mannequins respectively, compared to the 2D scan. The intraclass correlation between the single raters for mean percentage of the artificial burn areas was 98.6%. There was also a high intraclass correlation between the single raters and the 2D Scan visible. CONCLUSION: BurnCase 3D is a valid and reliable tool for the determination of total body surface area burned in standard models. Further clinical studies including different pediatric and overweight adult mannequins are warranted.


Assuntos
Superfície Corporal , Queimaduras/diagnóstico , Diagnóstico por Computador , Variações Dependentes do Observador , Software , Adulto , Queimaduras/diagnóstico por imagem , Criança , Feminino , Humanos , Imageamento Tridimensional , Masculino , Manequins , Projetos Piloto , Reprodutibilidade dos Testes
2.
Psychiatry Res ; 206(1): 111-3, 2013 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-23078873

RESUMO

Five pathological gamblers received deep transcranial magnetic stimulation (DTMS). Evaluations included rating scales and collateral anamnesis. Despite initial improvement in ratings, collateral anamnesis demonstrated failure to respond. DTMS to the pre-frontal cortex using an H1 coil was an ineffective treatment. Our study is preliminary, and additional studies are required.


Assuntos
Lobo Frontal/fisiologia , Jogo de Azar/terapia , Estimulação Magnética Transcraniana/métodos , Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Resultado do Tratamento
3.
Ann Gen Psychiatry ; 11: 13, 2012 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-22559192

RESUMO

BACKGROUND: About 25% of schizophrenia patients with auditory hallucinations are refractory to pharmacotherapy and electroconvulsive therapy. We conducted a deep transcranial magnetic stimulation (TMS) pilot study in order to evaluate the potential clinical benefit of repeated left temporoparietal cortex stimulation in these patients. The results were encouraging, but a sham-controlled study was needed to rule out a placebo effect. METHODS: A total of 18 schizophrenic patients with refractory auditory hallucinations were recruited, from Beer Yaakov MHC and other hospitals outpatient populations. Patients received 10 daily treatment sessions with low-frequency (1 Hz for 10 min) deep TMS applied over the left temporoparietal cortex, using the H1 coil at the intensity of 110% of the motor threshold. Procedure was either real or sham according to patient randomization. Patients were evaluated via the Auditory Hallucinations Rating Scale, Scale for the Assessment of Positive Symptoms-Negative Symptoms, Clinical Global Impressions, and Quality of Life Questionnaire. RESULTS: In all, 10 patients completed the treatment (10 TMS sessions). Auditory hallucination scores of both groups improved; however, there was no statistical difference in any of the scales between the active and the sham treated groups. CONCLUSIONS: Low-frequency deep TMS to the left temporoparietal cortex using the protocol mentioned above has no statistically significant effect on auditory hallucinations or the other clinical scales measured in schizophrenic patients. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT00564096.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA