Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
AJNR Am J Neuroradiol ; 40(7): 1112-1116, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31221634

RESUMO

BACKGROUND AND PURPOSE: Previous studies have suggested that gadolinium enhancement of the wall of unruptured intracranial aneurysms on MR imaging may reflect aneurysm wall instability. However, all previous studies were cross-sectional. In this longitudinal study, we investigated whether aneurysm wall enhancement is associated with an increased risk of aneurysm instability. MATERIALS AND METHODS: We included all patients 18 years of age or older with ≥1 unruptured aneurysm from the University Medical Center Utrecht, the Netherlands, who were included in 2 previous studies with either 3T or 7T aneurysm wall MR imaging and for whom it was decided not to treat the aneurysm but to monitor it with follow-up imaging. We investigated the risk of growth or rupture during follow-up of aneurysms with and without gadolinium enhancement of the aneurysm wall at baseline and calculated the risk difference between the 2 groups with corresponding 95% confidence intervals. RESULTS: We included 57 patients with 65 unruptured intracranial aneurysms. After a median follow-up of 27 months (interquartile range, 20-31 months), growth (n = 2) or rupture (n = 2) was observed in 4 of 19 aneurysms (21%; 95% CI, 6%-54%) with wall enhancement and in zero of 46 aneurysms (0%; 95% CI, 0%-8%) without enhancement (risk difference, 21%; 95% CI, 3%-39%). CONCLUSIONS: Gadolinium enhancement of the aneurysm wall on MR imaging is associated with an increased risk of aneurysm instability. The absence of wall enhancement makes it unlikely that the aneurysm will grow or rupture in the short term. Larger studies are needed to investigate whether aneurysm wall enhancement is an independent predictor of aneurysm instability.


Assuntos
Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/patologia , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Adolescente , Adulto , Idoso , Algoritmos , Meios de Contraste , Feminino , Seguimentos , Gadolínio , Humanos , Interpretação de Imagem Assistida por Computador , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Países Baixos
2.
AJNR Am J Neuroradiol ; 39(4): 713-719, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29472302

RESUMO

BACKGROUND AND PURPOSE: Aneurysm volume pulsation is a potential predictor of intracranial aneurysm rupture. We evaluated whether 7T MR imaging can quantify aneurysm volume pulsation. MATERIALS AND METHODS: In Stage I of the study, 10 unruptured aneurysms in 9 patients were studied using a high-resolution (0.6-mm, isotropic) 3D gradient-echo sequence with cardiac gating. Semiautomatic segmentation was used to measure aneurysm volume (in cubic millimeters) per cardiac phase. Aneurysm pulsation was defined as the relative increase in volume between the phase with the smallest volume and the phase with the largest volume. The accuracy and precision of the measured volume pulsations were addressed by digital phantom simulations and a repeat image analysis. In Stage II, the imaging protocol was optimized and 9 patients with 9 aneurysms were studied with and without administration of a contrast agent. RESULTS: The mean aneurysm pulsation in Stage I was 8% ± 7% (range, 2%-27%), with a mean volume change of 15 ± 14 mm3 (range, 3-51 mm3). The mean difference in volume change for the repeat image analysis was 2 ± 6 mm3. The artifactual volume pulsations measured with the digital phantom simulations were of the same magnitude as the volume pulsations observed in the patient data, even after protocol optimization in Stage II. CONCLUSIONS: Volume pulsation quantification with the current imaging protocol on 7T MR imaging is not accurate due to multiple imaging artifacts. Future studies should always include aneurysm-specific accuracy analysis.


Assuntos
Aneurisma Intracraniano/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Adulto , Idoso , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Fluxo Pulsátil
3.
AJNR Am J Neuroradiol ; 37(7): 1310-7, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26892986

RESUMO

BACKGROUND AND PURPOSE: Both hemodynamics and aneurysm wall thickness are important parameters in aneurysm pathophysiology. Our aim was to develop a method for semi-quantitative wall thickness assessment on in vivo 7T MR images of intracranial aneurysms for studying the relation between apparent aneurysm wall thickness and wall shear stress. MATERIALS AND METHODS: Wall thickness was analyzed in 11 unruptured aneurysms in 9 patients who underwent 7T MR imaging with a TSE-based vessel wall sequence (0.8-mm isotropic resolution). A custom analysis program determined the in vivo aneurysm wall intensities, which were normalized to the signal of nearby brain tissue and were used as measures of apparent wall thickness. Spatial wall thickness variation was determined as the interquartile range in apparent wall thickness (the middle 50% of the apparent wall thickness range). Wall shear stress was determined by using phase-contrast MR imaging (0.5-mm isotropic resolution). We performed visual and statistical comparisons (Pearson correlation) to study the relation between wall thickness and wall shear stress. RESULTS: 3D colored apparent wall thickness maps of the aneurysms showed spatial apparent wall thickness variation, which ranged from 0.07 to 0.53, with a mean variation of 0.22 (a variation of 1.0 roughly means a wall thickness variation of 1 voxel [0.8 mm]). In all aneurysms, apparent wall thickness was inversely related to wall shear stress (mean correlation coefficient, -0.35; P < .05). CONCLUSIONS: A method was developed to measure the wall thickness semi-quantitatively, by using 7T MR imaging. An inverse correlation between wall shear stress and apparent wall thickness was determined. In future studies, this noninvasive method can be used to assess spatial wall thickness variation in relation to pathophysiologic processes such as aneurysm growth and rupture.


Assuntos
Imageamento Tridimensional/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Idoso , Feminino , Hemodinâmica/fisiologia , Humanos , Aneurisma Intracraniano/patologia , Masculino , Pessoa de Meia-Idade , Estresse Mecânico
4.
Transpl Infect Dis ; 12(1): 23-30, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19744284

RESUMO

Cytomegalovirus (CMV) is a major cause of infectious complications following cardiac transplantation, severely affecting short- and long-term outcomes. A 12-month, multicenter, randomized, open-label study in de novo cardiac transplant patients was undertaken to compare the efficacy, renal function, and safety of everolimus plus reduced cyclosporine versus mycophenolate mofetil (MMF) plus standard cyclosporine (ClinicalTrials.gov NCT00150046). CMV-specific data was prospectively collected on infections, laboratory evidence, CMV syndrome, and CMV disease. In total, 176 patients were randomized (everolimus 92; MMF 84). Use of CMV prophylaxis was similar between groups (everolimus 20.8%; MMF 24.0%). Patients in the everolimus arm had a significantly lower incidence of any CMV event (8.8% versus 32.5% with MMF, P<0.001), CMV infection as an adverse event (4.4% versus 16.9%, P=0.011), laboratory evidence of CMV (antigenemia 7.7% versus 27.7%, P<0.001; polymerase chain reaction assay 2.2% versus 12.0%, P=0.015), and CMV syndrome (1.1% versus 8.4%, P=0.028). In the donor (D)+/recipient (R)+and D-/R+ subgroups, even after adjusting for use of prophylaxis, the CMV event rate remained significantly lower with everolimus than with MMF (P=0.0015 and P=0.0381, respectively). In conclusion, de novo cardiac transplant recipients experienced lower rates of CMV infection, CMV syndrome, or organ involvement on an everolimus-based immunosuppressant regimen compared with MMF.


Assuntos
Infecções por Citomegalovirus/epidemiologia , Transplante de Coração/efeitos adversos , Imunossupressores , Ácido Micofenólico/análogos & derivados , Sirolimo/análogos & derivados , Adulto , Ciclosporina/administração & dosagem , Ciclosporina/efeitos adversos , Ciclosporina/uso terapêutico , Citomegalovirus/efeitos dos fármacos , Infecções por Citomegalovirus/diagnóstico , Infecções por Citomegalovirus/prevenção & controle , Quimioterapia Combinada , Everolimo , Feminino , Rejeição de Enxerto/epidemiologia , Transplante de Coração/imunologia , Humanos , Imunossupressores/administração & dosagem , Imunossupressores/efeitos adversos , Imunossupressores/uso terapêutico , Incidência , Testes de Função Renal , Masculino , Pessoa de Meia-Idade , Ácido Micofenólico/administração & dosagem , Ácido Micofenólico/efeitos adversos , Ácido Micofenólico/uso terapêutico , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Sirolimo/uso terapêutico , Resultado do Tratamento
5.
Cardiovasc J S Afr ; 11(2): 82-85, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11447468

RESUMO

The internal thoracic artery (ITA) is used extensively for coronary revascularisation. Clinical observations suggest an inter-ethnic difference in ITA morphometry between Indians and whites presenting for coronary artery bypass surgery. However, accurate morphometric data comparing these ethnic groups were not available. This study analyses the morphometry of the left and right ITAs in 60 cadavers (43 blacks, 9 whites, 8 Indians). The lengths of the arteries were measured and the external diameters were recorded at the origin of the 1st, 4th and 6th costal cartilages. Significant differences in length and diameter on the right and left sides between ethnic groups were demonstrated. In particular, these differences were marked between the white and Indian groups. Clinically, these differences can be so marked that in some instances the left ITA in Indian patients is so small at the distal point of take-down as to be unsuitable for use as an arterial conduit. This is one of the reasons that has prompted the use of the ITA as a composite graft. Our study appears to be the first to highlight this inter-ethnic difference and to support the clinical impression.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA