Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Placenta ; 134: 1-8, 2023 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-36807998

RESUMO

INTRODUCTION: The goal of this pilot study is to determine if ferumoxytol-enhanced MR might provide a new approach to the diagnosis of placenta accreta spectrum (PAS), and if so, to identify signs of PAS. METHODS: Ten pregnant women were referred for MRI evaluation for PAS. MR studies consisted of pre-contrast SSFSE, SSFP, DWI, and ferumoxytol-enhanced sequences. Post-contrast images were rendered as MIP and MinIP images to separately display the maternal and fetal circulations respectively. Two readers examined the images for architectural changes to placentone (fetal cotyledon) that might distinguish PAS cases from normal. Attention was given to the size and morphology of the placentone, villous tree, and vascularity. In addition, the images were examined for evidence of fibrin/fibrinoid, intervillous thrombus, basal and chorionic plate bulges. Interobserver agreement was characterized with kappa coefficients and levels of confidence for feature identification was recorded on a 10-point scale. RESULTS: At delivery, there were five normal placentas and five with PAS (one accreta, two increta, two percreta). The ten changes of placental architecture in PAS included: focal/regional expansion of placentone(s); lateral displacement and compression of the villous tree; disruption of a regular pattern of normal placentones; bulging of the basal plate; bulging of the chorionic plate; transplacental stem villi; linear/nodular bands at basal plate; non-tapering villous branches; intervillous hemorrhage; and dilated subplacental vessels. All these changes were more common in PAS; the first five achieved statistical significance in this small sample. The interobserver agreement and confidence for the identification of these features was good to excellent except for dilated subplacental vessels. DISCUSSION: Ferumoxytol-enhanced MR imaging appears to depict derangements of the internal architecture of placentas with PAS, thereby suggesting a promising new strategy to diagnose PAS.


Assuntos
Placenta Acreta , Placenta Prévia , Gravidez , Feminino , Humanos , Placenta Acreta/diagnóstico , Placenta , Óxido Ferroso-Férrico , Projetos Piloto , Placenta Prévia/diagnóstico , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos
2.
Abdom Radiol (NY) ; 48(1): 377-386, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36273328

RESUMO

PURPOSE: To characterize intraplacental blood flow patterns in placenta accreta spectrum (PAS) with color and spectral Doppler imaging. METHODS: Thirty-two patients at risk for PAS underwent ultrasound imaging with both color and spectral Doppler. The placenta was inspected for areas of vascularity by color Doppler, particularly within the lower uterine segment. Spectral Doppler waveforms were obtained from these vessels and categorized as either intraplacental or subplacental (myometrial), venous or arterial, fetal or maternal (based on heart rate). Arterial waveforms were measured for heart rate, peak systolic velocity, end diastolic velocity, and resistive index. Statistical comparisons were made between cases with and without PAS using Fisher exact tests (categorical variables) and Mann-Whitney U tests (numerical indices). Interobserver agreement was characterized with kappa coefficients. RESULTS: At delivery, there were 19 cases with PAS and 13 without PAS. On ultrasound studies, clustered intraplacental vascularity was found in the lower uterine segment in 66% of cases (95% of PAS cases and 23% cases without PAS; p < 0.0001). Maternal arterial waveforms were found within the vascular cluster in 84% of PAS cases and 15% of cases without PAS (p < 0.0001). A traversing fetal artery was found within the vascular cluster in 56% of cases (84% PAS cases and 15% cases without PAS; p = 0.001). Venous waveforms were found in 84% of PAS cases and 15% of cases without PAS. Interobserver agreement was good to excellent. CONCLUSION: Intraplacental blood flow pattern in PAS is characterized by an intraplacental vascular cluster containing low-resistance maternal arterial flow and transplacental fetal arteries.


Assuntos
Placenta Acreta , Placenta Prévia , Gravidez , Feminino , Humanos , Placenta Acreta/diagnóstico por imagem , Placenta/diagnóstico por imagem , Ultrassonografia Doppler , Artérias/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos
3.
Abdom Radiol (NY) ; 48(2): 744-751, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36462034

RESUMO

PURPOSE: To elucidate ultrasound features of normal placental anatomy through correlation of gray-scale and ultrasound Doppler with ferumoxytol-enhanced MRI features using US-MR image fusion. METHODS: All patients referred to MR for ultrasound findings worrisome for PAS (placenta accreta spectrum) were included in this retrospective study. MR studies included a ferumoxytol-enhanced T1-weighted MRI. Ultrasound imaging included gray-scale, color Doppler, power Doppler, and spectral Doppler techniques. After the MR, US-MRI fusion was performed by co-registering a MR acquisition to real-time US, which allowed precise, point-to-point correlation of placental features. RESULTS: Fourteen patients at risk for PAS were studied using the US-MR image fusion. At delivery, there were six cases without PAS (gestational age range: 24 weeks 3 days to 34 weeks 0 days), and these composed the study cohort. Placental features that were on high signal intensity on post-ferumoxytol acquisitions represent spaces with maternal blood flow and corresponded to hypoechoic areas on ultrasound created by a paucity of reflective interfaces (villi). Color and spectral Doppler allowed the separation of maternal and fetal circulations in individual perfusional domains and demonstrated spiral artery inflow, circulation around the villous tree, and return of blood flow to the basal plate. Recognizable histopathologic features by ultrasound included the central cavity, villous tree, and venous return channels. CONCLUSION: Internal placental architecture can be discerned on ultrasound. This anatomy can be correlated and confirmed with ferumoxytol-MR through US-MR fusion. Understanding this structural anatomy on ultrasound could serve as a basis to identify normal and abnormal placental features.


Assuntos
Óxido Ferroso-Férrico , Placenta , Gravidez , Humanos , Feminino , Lactente , Placenta/diagnóstico por imagem , Estudos Retrospectivos , Ultrassonografia Pré-Natal/métodos , Ultrassonografia , Imageamento por Ressonância Magnética/métodos
4.
Placenta ; 131: 104-110, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36577278

RESUMO

INTRODUCTION: Placental function is vitally important, but placental assessment is limited by current imaging methods in vivo. The goal of this study is to determine if ferumoxytol-enhanced MR studies might be used to depict placental structure during pregnancy. METHODS: Ten pregnant women were referred for MRI evaluation of abnormal placentation. The study group was composed five of these patients whose placentas were normal at pathology. MR studies consisted of pre-contrast SSFSE (single-shot fast spin-echo), SSFP (steady-state free procession), diffusion, and ferumoxytol-enhanced acquisitions. The post-contrast sequences were compared to pre-contrast SSFSE, SSFP, and diffusion acquisitions for features of correspondence. MR images were also compared to histopathology for anatomic landmarks including the three-ring pattern of the functional vascular exchange unit (the placentone) created by this central cavity surrounded by a ring of clustered villi, and an outer ring of dispersed villi corresponding to the maternal venous outflow channel. The measured sizes of these features on MR were compared to reported sizes. RESULTS: Post-ferumoxytol images showed enhancement of the maternal blood within the placenta, notably the intervillous space and the myometrial vessels. The unenhanced fetal vessels were most visible on the MinIP (minimum intensity projection) images; the enhanced maternal vessels were most visible on the MIP (maximum intensity projection) images. Composite MIP/MinIP images show the relation of maternal and fetal circulations. The signal intensities replicate the relative contributions from enhanced maternal blood and unenhanced chorionic villi. DISCUSSION: Ferumoxytol-enhanced MR imaging can depict the internal anatomy of the placenta in vivo of clarity and detail. This could represent a new diagnostic approach to placental disorders.


Assuntos
Óxido Ferroso-Férrico , Placenta , Feminino , Gravidez , Humanos , Placenta/patologia , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Placentação
6.
Curr Probl Diagn Radiol ; 51(4): 639-647, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34583872

RESUMO

When first learning abdominal CT studies, residents are often given little concrete, practical direction. There is, however, a large literature from the visual and cognitive sciences that can provide guidance towards search strategies that maximize efficiency and comprehensiveness. This literature has not penetrated radiology teaching to any great extent. In this article, we will examine the current pedagogy (and why that falls short), why untutored search fails, where misses occur in abdomen/pelvis CT, why these misses occur where they do, how expert radiologists search 3d image stacks, and how novices might expedite the acquisition of expertise.


Assuntos
Abdome , Radiologia , Abdome/diagnóstico por imagem , Ciência Cognitiva , Humanos , Radiologistas , Radiologia/educação , Tomografia Computadorizada por Raios X/métodos
7.
AJR Am J Roentgenol ; 217(1): 164-171, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33978451

RESUMO

OBJECTIVE. The purpose of the present study was to identify the subset of a wide range of serial Doppler, laboratory, and clinical parameters most predictive (both individually and in combination) of TIPS dysfunction in a large patient sample. MATERIALS AND METHODS. The medical records of 189 patients who had undergone TIPS procedures were analyzed. The patients (mean age, 52 years; 62% of whom were men) had undergone 1139 Doppler studies and 323 portovenograms. Laboratory parameters included model for end-stage liver disease (MELD) scores, serum albumin levels, presence of ascites, and time since last intervention. Doppler parameters included intrashunt velocities, temporal change in intrashunt velocities, main portal vein velocity, direction of flow in the left portal hepatic vein, and venous pulsatility index. Statistical analysis used ROC, univariate, and multivariate regression models to assess the parameters both individually and in combination. Shunt dysfunction was defined by a portosystemic gradient of more than 12 mm Hg. RESULTS. The laboratory and clinical parameters of greatest predictive value included the MELD score and the time since the last intervention. The Doppler parameters that were of greatest predictive value included the change in velocity at the hepatic venous end and the left portal vein flow direction. Multivariate models produced an AUC of 0.74. Differences between functional and dysfunctional shunts were also statistically significant for absolute velocity at the hepatic venous end, the change in velocity within the stent, and the temporal change in the mid shunt velocity. CONCLUSION. The subset of serial parameters most predictive of TIPS dysfunction are the temporal change in the velocity at the hepatic venous end, the absolute velocity at the hepatic venous end, the direction of flow in the left portal venous branch, and changes in the MELD score.


Assuntos
Doença Hepática Terminal/diagnóstico , Doença Hepática Terminal/fisiopatologia , Derivação Portossistêmica Transjugular Intra-Hepática , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/fisiopatologia , Ultrassonografia Doppler/métodos , Ascite/sangue , Velocidade do Fluxo Sanguíneo/fisiologia , Doença Hepática Terminal/sangue , Feminino , Veias Hepáticas/diagnóstico por imagem , Veias Hepáticas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Veia Porta/diagnóstico por imagem , Veia Porta/fisiopatologia , Complicações Pós-Operatórias/sangue , Albumina Sérica , Fatores de Tempo
8.
AJR Am J Roentgenol ; 216(4): 1126-1133, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33624521

RESUMO

OBJECTIVE. The purpose of our study was to assess the feasibility of 2D shear wave ultrasound elastography to quantitatively measure changes of rigor mortis. SUBJECTS AND METHODS. Muscle stiffness of two live pigs and nine sacrificed pigs was measured in kilopascals using ultrasound elastography. The nine sacrificed pigs were divided into three groups of three pigs each and placed in one of three environments at 90°F (32°C), 70°F (21°C), or 34°F (1°C). Ultrasound elastography of five muscles was performed at 1- to 2-hour intervals for up to 50 hours postmortem. For each pig and muscle location, the time to start, peak intensity, duration of peak, and time to decline of rigor mortis were identified from the graphs of muscle stiffness values over time. These outcome variables were then compared across ambient temperature, body weight, and age groups using the Wilcoxon rank sum test. RESULTS. Postmortem measurements show a rise, peak, and decline of muscle stiffness after death. Rigor mortis was highly significantly affected by ambient temperature (p < .001), was significantly affected by body weight (p = .04), and was not significantly affected by animal age or muscle location (facial vs truncal vs limb) (p > .50). Peak intensity of rigor mortis developed more quickly but attained lower levels of muscle stiffness at 90°F (80-100 kPa) compared with 70°F and 34°F (280-300 kPa) (p < .001). The duration of peak rigor mortis and the time to decline of rigor mortis were significantly longer for the lower temperatures (p < .001). CONCLUSION. Two-dimensional shear wave ultrasound elastography can quantifi-ably measure the trajectory of rigor mortis in an animal model. This new approach may have direct implications for human forensic investigations.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Medicina Legal/métodos , Músculo Esquelético/diagnóstico por imagem , Rigor Mortis/diagnóstico por imagem , Fatores Etários , Animais , Peso Corporal , Modelos Animais de Doenças , Estudos de Viabilidade , Feminino , Rigor Mortis/diagnóstico , Suínos , Temperatura , Fatores de Tempo
9.
J Clin Imaging Sci ; 11: 1, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33500836

RESUMO

OBJECTIVES: The routine search patterns used by subspecialty abdominal imaging experts to inspect the image volumes of abdominal/pelvic computed tomography (CT) have not been well characterized or rendered in practical or teachable terms. The goal of this study is to describe the search patterns used by experienced subspecialty imagers when reading a normal abdominal CT at a modern picture archiving and communication system workstation, and utilize this information to propose guidelines for residents as they learn to interpret CT during training. MATERIAL AND METHODS: Twenty-two academic subspecialists enacted their routine search pattern on a normal contrast-enhanced abdominal/pelvic CT study under standardized display parameters. Readers were told that the scan was normal and then asked to verbalize where their gaze centered and moved through the axial, coronal, and sagittal image stacks, demonstrating eye position with a cursor as needed. A peer coded the reported eye gaze movements and scrilling behavior. Spearman correlation coefficients were calculated between years of professional experience and the numbers of passes through the lung bases, liver, kidneys, and bowel. RESULTS: All readers followed an initial organ-by-organ approach. Larger organs were examined by drilling, while smaller organs by oscillation or scanning. Search elements were classified as drilling, scanning, oscillation, and scrilling (scan drilling); these categories were parsed as necessary. The greatest variability was found in the examination the body wall and bowel/mesentery. Two modes of scrilling were described, and these classified as roaming and zigzagging. The years of experience of the readers did not correlated to number of passes made through the lung bases, liver, kidneys, or bowel. CONCLUSION: Subspecialty abdominal radiologists negotiate through the image stacks of an abdominal CT study in broadly similar ways. Collation of the approaches suggests a foundational search pattern for new trainees.

10.
J Ultrasound Med ; 40(2): 299-303, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32706144

RESUMO

OBJECTIVES: To determine how measurements of the internal carotid artery (ICA) cross-sectional area will differ systematically when obtained by grayscale, color Doppler, and power Doppler imaging. METHODS: A total of 451 patients had greater than 40% diameter stenosis in at least a single ICA. Anteroposterior and transverse luminal diameters were measured in 609 arteries on grayscale, color, and power Doppler transverse images of the carotid bulb and proximal and distal ICAs. Cross-sectional areas were calculated and compared by a repeated-measures analysis of variance model to assess for significant differences. RESULTS: Mean ICA cross-sectional areas ± SDs as measured by grayscale, power Doppler, and color Doppler imaging were 122 ± 81, 122 ± 79, and 125 ± 79 mm2 , respectively. The mean ICA area estimated by color Doppler imaging was significantly greater than that estimated by power Doppler imaging (P < .0001) and grayscale imaging (P = .02). Area estimates on grayscale and power Doppler images were not significantly different (P = .99). After accounting for the correlation of repeated measurements within single vessels, color Doppler estimates of the luminal area were on average 3.44 and 9.5 mm2 greater than grayscale and power Doppler estimates. Relative cross-sectional area estimates were on average 9.4% greater with color Doppler imaging at smaller luminal diameters (<60 mm2 ) compared with larger luminal diameters. CONCLUSIONS: Measurements of the ICA cross-sectional area by color Doppler imaging were significantly greater than those obtained by power Doppler or grayscale imaging. This difference should be considered when stenosis estimates are confirmed or graded by luminal measurements.


Assuntos
Artéria Carótida Interna , Estenose das Carótidas , Velocidade do Fluxo Sanguíneo , Artéria Carótida Interna/diagnóstico por imagem , Humanos , Ultrassonografia Doppler , Ultrassonografia Doppler em Cores
11.
J Ultrasound Med ; 40(2): 359-367, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32725845

RESUMO

OBJECTIVES: To characterize fluctuations in peak systolic velocities (PSVs) in Doppler waveforms of the carotid artery in patients with and without obstructive airway disease and in volunteers subjected to incremental levels of airway resistance in an experimental model. METHODS: The PSV variation in common carotid waveforms was measured in 100 patients who had had a carotid ultrasound examination and no respiratory or carotid disease. This was compared to that of patients who had this study during an admission for acute exacerbation of chronic obstructive pulmonary disease (COPD). The PSV variation was correlated with pulmonary function testing. In addition, 14 healthy volunteers were asked to breathe through 5 resistors. Simultaneous recordings were made of Doppler waveforms in the common carotid artery, cardiac activity, and respiration. Peak systolic velocity changes from inspiration to expiration were calculated. RESULTS: Of the 100 patients without respiratory disease, the magnitude of the PSV variation averaged 6.3 cm/s. Of the 33 patients with COPD, the PSV variation averaged 16.5 cm/s. Nineteen of the 33 patients with COPD had concurrent pulmonary function testing; there was a statistically significant correlation between the PSV variation and forced vital capacity and forced expiratory volume indices. For the volunteers, mean velocity changes were 7.1, 6.6, 8.3, 15.1, and 16.1 cm/s for 0.00-, 2.15-, 3.27-, 3.58-, and 5.77-cm H2 O/L/s levels of breathing resistance, respectively. There was a statistically significant relationship between an increasing airway load and the decline in PSV during inspiration (P = .02). CONCLUSIONS: The PSV variation is greater in patients with increased airway resistance. Similar changes are evident in volunteers breathing into resistors. These findings likely reflect pulsus paradoxus.


Assuntos
Estenose das Carótidas , Doença Pulmonar Obstrutiva Crônica , Velocidade do Fluxo Sanguíneo , Artéria Carótida Primitiva/diagnóstico por imagem , Humanos , Pulmão , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Respiração , Sístole , Ultrassonografia Doppler Dupla
12.
Abdom Radiol (NY) ; 46(4): 1746-1751, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33040173

RESUMO

RATIONALE AND OBJECTIVE: Variation of visual selective attention through the day has been demonstrated in several arenas of human performance, including radiology. It is uncertain whether this variation translates to an identifiable diurnal pattern of error rates for radiology interpretation. The purpose of this study was to attempt to identify particular days of the week and times of the day when radiologists might be most prone to error. MATERIALS AND METHODS: Abdomen/pelvis CT studies containing at least one major error were collected from a 10-year period from the quality assurance (QA) database at our institution. A major error was defined as a missed finding that had altered management in a way potentially detrimental to the patient. The identified studies were categorized by the day of the week and hour of the day that the study was interpreted. Study volume data over this same period was also obtained by day of the week and time of day, so to normalize the data based on case volume. Standard errors of the volume-adjusted error rates were obtained based on the binomial distribution. The null hypothesis of constant error rates over time was tested using a weighted logistic regression model with linear time as predictor. RESULTS: A total of 252 major errors were identified. More errors were made on Monday than on any other day of the week (n = 58). Major error rates increased through the mid to late morning (9 am to 12 pm), and then decreased progressively through the afternoon until 4 pm, when a rise in the error rate was seen. This pattern persisted when error rates were normalized by study volume within each hour. Overall tests of time-constancy of error rates by day and hour were statistically significant (both p-values < 0.001). CONCLUSION: Our study shows that error rates in abdominal CT do seem to vary with time of day and day of the week. During the workweek, error rates were highest in the late morning and at the close of the workday, and greater on Mondays than other days.


Assuntos
Radiologia , Abdome , Ritmo Circadiano , Humanos , Pelve/diagnóstico por imagem , Tomografia Computadorizada por Raios X
13.
J Clin Imaging Sci ; 10: 70, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33194312

RESUMO

OBJECTIVES: Radiologists reading multiplanar abdominal/pelvic computed tomography (CT) are vulnerable to oversight of specific anatomic areas, leading to perceptual errors (misses). The aims of this study are to identify common sites of major perceptual error at our institution and then to put these in context with earlier studies to produce a comprehensive overview. MATERIAL AND METHODS: We reviewed our quality assurance database over an 8-year period for cases of major perceptual error on CT examinations of the abdomen and pelvis. A major perceptual error was defined as a missed finding that had altered management in a way potentially detrimental to the patient. Record was made of patient age, gender, study indication, study priority (stat/routine), and use of IV and/or oral contrast. Anatomic locations were subdivided as lung bases, liver, pancreas, kidneys, spleen, mesentery, peritoneum, retroperitoneum, small bowel, colon, appendix, vasculature, body wall, and bones. RESULTS: A total of 216 missed findings were identified in 201 patients. The most common indication for the study was cancer follow-up (71%) followed by infection (11%) and abdominal pain (6%). The most common anatomic regions of error were the liver (15%), peritoneum (10%), body wall (9%), retroperitoneum (8%), and mesentery (6%). Data from other studies were reorganized into congruent categories for comparison. CONCLUSION: This study demonstrates that the most common sites of significant missed findings on multiplanar abdominal/pelvic CT included the mesentery, peritoneum, body wall, bowel, vasculature, and the liver in the arterial phase. Data from other similar studies were reorganized into congruent categories to provide a comprehensive overview.

14.
AJR Am J Roentgenol ; 212(3): 602-606, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30620671

RESUMO

OBJECTIVE: Radiology reports have traditionally been written for referring clinical providers. However, as patients increasingly access their radiology reports through online medical records, concerns have been raised about their ability to comprehend these complex documents. The purpose of this study was to assess the readability of lumbar spine MRI reports. MATERIALS AND METHODS: We reviewed 110 lumbar spine MRI reports dictated by 11 fellowship-trained radiologists (eight musculoskeletal radiologists and three neuroradiologists) at a single academic medical center. We evaluated each article for readability using five quantitative readability tests: the Flesch-Kincaid Grade Level, Flesch Reading Ease, Gunning Fog Index, Coleman-Liau Index, and the Simple Measure of Gobbledygook. The number of reports with readability at or below eighth-grade level (average reading ability of U.S. adults) and at or below sixth-grade level (level recommended by the National Institutes of Health and the American Medical Association for patient education materials) were determined. RESULTS: The mean readability grade level of the lumbar spine MRI reports was greater than the 12th-grade reading level for all readability scales. Only one report was written at or below eighth-grade level; no reports were written at or below sixth-grade level. CONCLUSION: Lumbar spine MRI reports are written at a level too high for the average patient to comprehend. As patients increasingly read their radiology reports through online portals, consideration should be made of patients' ability to read and comprehend these complex medical documents.


Assuntos
Compreensão , Letramento em Saúde , Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética , Doenças da Coluna Vertebral/diagnóstico por imagem , Adulto , Humanos
15.
AJR Am J Roentgenol ; 208(1): 92-100, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27726414

RESUMO

OBJECTIVE: The purpose of this study was to prospectively evaluate the accuracy of proton-density fat-fraction, single- and dual-energy CT (SECT and DECT), gray-scale ultrasound (US), and US shear-wave elastography (US-SWE) in the quantification of hepatic steatosis with MR spectroscopy (MRS) as the reference standard. SUBJECTS AND METHODS: Fifty adults who did not have symptoms (23 men, 27 women; mean age, 57 ± 5 years; body mass index, 27 ± 5) underwent liver imaging with un-enhanced SECT, DECT, gray-scale US, US-SWE, proton-density fat-fraction MRI, and MRS for this prospective trial. MRS voxels for the reference standard were colocalized with all other modalities under investigation. For SECT (120 kVp), attenuation values were recorded. For rapid-switching DECT (80/140 kVp), monochromatic images (70-140 keV) and fat density-derived material decomposition images were reconstructed. For proton-density fat fraction MRI, a quantitative chemical shift-encoded method was used. For US, echogenicity was evaluated on a qualitative 0-3 scale. Quantitative US shear-wave velocities were also recorded. Data were analyzed by linear regression for each technique compared with MRS. RESULTS: There was excellent correlation between MRS and both proton-density fat-fraction MRI (r2 = 0.992; slope, 0.974; intercept, -0.943) and SECT (r2 = 0.856; slope, -0.559; intercept, 35.418). DECT fat attenuation had moderate correlation with MRS measurements (r2 = 0.423; slope, 0.034; intercept, 8.459). There was good correlation between qualitative US echogenicity and MRS measurements with a weighted kappa value of 0.82. US-SWE velocity did not have reliable correlation with MRS measurements (r2 = 0.004; slope, 0.069; intercept, 6.168). CONCLUSION: Quantitative MRI proton-density fat fraction and SECT fat attenuation have excellent linear correlation with MRS measurements and can serve as accurate noninvasive biomarkers for quantifying steatosis. Material decomposition with DECT does not improve the accuracy of fat quantification over conventional SECT attenuation. US-SWE has poor accuracy for liver fat quantification.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Gordura Intra-Abdominal/fisiologia , Fígado/fisiologia , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Prótons por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Adiposidade/fisiologia , Feminino , Humanos , Gordura Intra-Abdominal/diagnóstico por imagem , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Am J Med Genet C Semin Med Genet ; 172(2): 190-7, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27164360

RESUMO

Neurobehavioral and developmental issues with a broad range of deficits are prominent features of Cornelia de Lange syndrome (CdLS), a disorder due to disruption of the cohesin protein complex. The etiologic relationship of these clinical findings to anatomic abnormalities on neuro-imaging studies has not, however, been established. Anatomic abnormalities in the brain and central nervous system specific to CdLS have been observed, including changes in the white matter, brainstem, and cerebellum. We hypothesize that location and severity of brain abnormalities correlate with clinical phenotype in CdLS, as seen in other developmental disorders. In this study, we retrospectively evaluated brain MRI studies of 15 individuals with CdLS and compared these findings to behavior at the time of the scan. Behavior was assessed using the Aberrant Behavior Checklist (ABC), a validated behavioral assessment tool with several clinical features. Ten of fifteen (67%) of CdLS patients had abnormal findings on brain MRI, including cerebral atrophy, white matter changes, cerebellar hypoplasia, and enlarged ventricles. Other findings included pituitary tumors or cysts, Chiari I malformation and gliosis. Abnormal behavioral scores in more than one behavioral area were seen in all but one patient. All 5 of the 15 (33%) patients with normal structural MRI studies had abnormal ABC scores. All normal ABC scores were noted in only one patient and this was correlated with moderately abnormal MRI changes. Although our cohort is small, our results suggest that abnormal behaviors can exist in individuals with CdLS in the setting of relatively normal structural brain findings. © 2016 Wiley Periodicals, Inc.


Assuntos
Encéfalo/patologia , Síndrome de Cornélia de Lange/patologia , Imageamento por Ressonância Magnética , Transtornos Mentais/diagnóstico , Adolescente , Adulto , Análise do Comportamento Aplicada , Criança , Pré-Escolar , Síndrome de Cornélia de Lange/complicações , Feminino , Humanos , Masculino , Estudos Retrospectivos , Adulto Jovem
17.
J Biomech ; 48(10): 1730-6, 2015 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-26072212

RESUMO

Ultrasound elastography is envisioned as an optional modality to augment standard ultrasound B-mode imaging and is a promising technique to aid in detecting uterine masses which cause abnormal uterine bleeding in both pre- and post-menopausal women. In order to determine the effectiveness of strain imaging, mechanical testing to establish the elastic contrast between normal uterine tissue and stiffer masses such as leiomyomas (fibroids) and between softer pathologies such as uterine cancer and adenomyosis has to be performed. In this paper, we evaluate the stiffness of normal uterine tissue, leiomyomas, and endometrial cancers using a EnduraTEC ElectroForce (ELF) system. We quantify the viscoelastic characteristics of uterine tissue and associated pathologies globally by using two mechanical testing approaches, namely a dynamic and a quasi-static (ramp testing) approach. For dynamic testing, 21 samples obtained from 18 patients were tested. The testing frequencies were set to 1, 10, 20, and 30 Hz. We also report on stiffness variations with pre-compression from 1% to 6% for testing at 2%, 3%, and 4% strain amplitude. Our results show that human uterine tissue stiffness is both dependent on percent pre-compression and testing frequencies. For ramp testing, 20 samples obtained from 14 patients were used. A constant strain rate of 0.1% was applied and comparable results to dynamic testing were obtained. The mean modulus contrast at 2% amplitude between normal uterine tissue (the background) and leiomyomas was 2.29 and 2.17, and between the background and cancer was 0.47 and 0.39 for dynamic and ramp testing, respectively.


Assuntos
Neoplasias do Endométrio/fisiopatologia , Leiomioma/fisiopatologia , Útero/fisiologia , Adulto , Elasticidade , Feminino , Humanos , Pressão , Estresse Mecânico , Viscosidade
18.
Ultrasound Med Biol ; 40(1): 78-89, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24120415

RESUMO

Instability in carotid vulnerable plaque can generate cerebral micro-emboli, which may be related to both stroke and eventual cognitive abnormality. Strain imaging to detect plaque vulnerability based on regions with large strain fluctuations, with arterial pulsation, may be able to determine the risk of cognitive impairment. Plaque instability may be characterized by increased strain variations over a cardiac cycle. Radiofrequency signals for ultrasound strain imaging were acquired from the carotid arteries of 24 human patients using a Siemens Antares with a VFX 13-5 linear array transducer. These patients underwent standardized cognitive assessment (Repeatable Battery for the Assessment of Neuropsychological Status [RBANS]). Plaque regions were segmented by a radiologist at end-diastole using the Medical Imaging Interaction Toolkit. A hierarchical block-matching motion tracking algorithm was used to estimate the cumulated axial, lateral and shear strains within the imaging plane. The maximum, minimum and peak-to-peak strain indices in the plaque computed from the mean cumulated strain over a small region of interest in the plaque with large deformations were obtained. The maximum and peak-to-peak mean cumulated strain indices over the entire plaque region were also computed. All strain indices were then correlated with RBANS Total performance. Overall cognitive performance (RBANS Total) was negatively associated with values of the maximum strain and the peak-to-peak for axial and lateral strains, respectively. There was no significant correlation between the RBANS Total score and shear strain and strain indices averaged over the entire identified plaque for this group of patients. However, correlation of maximum lateral strain was higher for symptomatic patients (r = -0.650, p = 0.006) than for asymptomatic patients (r = -0.115, p = 0.803). On the other hand, correlation of maximum axial strain averaged over the entire plaque region was significantly higher for asymptomatic patients (r = -0.817, p = 0.016) than for symptomatic patients (r = -0.224, p = 0.402). The results reveal a direct relationship between the maximum axial and lateral strain indices in carotid plaque and cognitive impairment.


Assuntos
Algoritmos , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Transtornos Cognitivos/diagnóstico por imagem , Transtornos Cognitivos/etiologia , Interpretação de Imagem Assistida por Computador/métodos , Placa Aterosclerótica/diagnóstico por imagem , Adulto , Idoso , Estenose das Carótidas/fisiopatologia , Transtornos Cognitivos/fisiopatologia , Módulo de Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/complicações , Prognóstico , Reprodutibilidade dos Testes , Medição de Risco , Sensibilidade e Especificidade , Estatística como Assunto , Estresse Mecânico
19.
J Ultrasound Med ; 32(8): 1443-50, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23887955

RESUMO

OBJECTIVES: The purpose of this study was to retrospectively review the diagnostic accuracy of sonography in the evaluation of superficial masses with surgical and histologic findings as the reference standard. METHODS: Institutional Review Board approval was obtained, informed consent was waived, and Health Insurance Portability and Accountability Act compliance was maintained. Seventy-two superficial masses in 62 patients were examined sonographically by a single radiologist (reader 1) and subsequently underwent surgical therapy. Three radiologists experienced in sonography, blinded to the original interpretation and surgical findings, retrospectively and independently reviewed the sonographic images and assigned the cases to 1 of 14 diagnostic categories. For all lesions, the rendered diagnosis was compared with the reference standard to determine concordance. For the specific diagnosis of lipoma, sensitivity, specificity, and accuracy were assessed for all readers individually and collectively. RESULTS: Surgery and histolopathologic analysis yielded 39 lipomas, 6 hernias, 4 foreign bodies, 4 hemangiomas, and 19 other nonlipomatous lesions, including 1 malignancy. The rendered diagnosis was concordant with the reference standard in 93% of cases for reader 1 and in 89% of cases for all readers. The sensitivity, specificity, and accuracy for the diagnosis of lipoma were 92%, 100%, and 96% for reader 1 and 96%, 97%, and 96% for all readers. CONCLUSIONS: Sonography has high accuracy in the evaluation of superficial masses, particularly lipomas.


Assuntos
Neoplasias de Tecidos Moles/diagnóstico por imagem , Ultrassonografia/métodos , Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
20.
J Ultrasound Med ; 31(4): 609-15, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22441918

RESUMO

In this article, we demonstrate the feasibility of saline infusion sonohysterography-based strain imaging for the determination of stiffness variations in uterine masses in vivo. Strain images are estimated using a 2-dimensional multilevel hybrid algorithm developed for sector array ultrasound transducers. Coarse displacements are initially estimated using envelope echo signals, followed by a guided finer displacement estimation using window lengths on the order of 6 wavelengths and 7 A-lines on radiofrequency data. Strain images are obtained by estimating displacement slopes using least squares estimation. In this prospective study, we show that stiffer masses such as fibroids appear darker or as regions with low strain on strain images and are thus clearly differentiated when compared to normal uterine tissue. A high strain boundary around stiffer masses referred to as a "halo" due to increased slipping or sliding of the mass during the applied deformation is also visualized. Uterine polyps, on the other hand, are visualized as masses that are brighter or regions with high strain when compared to the background myometrium, indicating the presence of a softer mass. Axial strain images provide additional new information that may supplement current clinical B-mode imaging used for the diagnosis of uterine abnormalities. Our results show the feasibility of improving clinical diagnosis based on strain imaging.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Cloreto de Sódio/administração & dosagem , Neoplasias Uterinas/diagnóstico por imagem , Adulto , Meios de Contraste/administração & dosagem , Feminino , Humanos , Infusões Parenterais , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA