Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Eur Heart J Cardiovasc Imaging ; 25(10): 1415-1422, 2024 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-38801398

RESUMO

AIMS: As transcatheter mitral valve (MV) interventions are expanding and more device types and sizes become available, a tool supporting operators in pre-procedural planning and the clinical decision-making process is highly desirable. We sought to develop a finite element computational simulation model to predict the results of transcatheter edge-to-edge repair (TEER) interventions. METHODS AND RESULTS: We prospectively enrolled patients with secondary mitral regurgitation (MR) referred for a clinically indicated TEER. The 3D trans-oesophageal echocardiograms performed at the beginning of the procedure were used to perform the simulation. On the 3D dynamic model of the MV that was first obtained, we simulated the clip implantation using the same clip type, size, number, and implantation location that was used during the intervention. The 3D model of the MV obtained after the simulation of the clip implantation was compared with the clinical results obtained at the end of the intervention. We analysed the degree and location of residual MR and the shape and area of the diastolic MV area. We performed computational simulation on five patients. Overall, the simulated models predicted well the degree and location of the residual regurgitant orifice(s) but tended to underestimate the diastolic mitral orifice area. CONCLUSION: In this proof-of-concept study, we present preliminary results on our algorithm simulating clip implantation in five patients with functional MR. We show promising results regarding the feasibility and accuracy in terms of predicting residual MR and the need to improve the estimation of the diastolic MV area.


Assuntos
Cateterismo Cardíaco , Simulação por Computador , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Insuficiência da Valva Mitral , Estudo de Prova de Conceito , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Feminino , Masculino , Estudos Prospectivos , Idoso , Cateterismo Cardíaco/métodos , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia
2.
Cardiovasc Diagn Ther ; 14(1): 59-71, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38434560

RESUMO

Background: Endomyocardial biopsies (EMB) are recommended for the detection of acute cardiac rejection (ACR) despite limited sensitivity. We report the long-term post-transplant results of Doppler echocardiography as a noninvasive alternative of routine EMB. Methods: Two cohorts of heart transplantation (HT) recipients were chronologically defined as follows: the Dual Monitoring Cohort (DMC) from January 1990 to December 1997 included patients who underwent routine EMB and Doppler echocardiography within 24 hours for ACR surveillance; and the "Echo-First Cohort" (EFC), including patients transplanted from January 1998 to December 2018 with Doppler echocardiography as first-line approach for ACR surveillance. Echocardiographic measurements of interest were collected: early diastolic (E) wave peak velocity; pressure half time (PHT) and isovolumetric relaxation time (IVRT). Post-transplant outcomes were reviewed and the Kaplan-Meier approach was used for survival estimates. Inter-operator variability for ultrasound measurements was investigated. Data were collected from medical records from January 2019 to December 2020. Results: A total of 228 patients were included, 99 patients in the DMC and 129 in the EFC. Overall, 5-, 10- and 15-year survival rates were 65.4%, 55.5% and 44.1% respectively, without any significant difference between the two cohorts (log rank test, P=0.71). Echocardiography variables and EMB findings were associated with a mean area under the receiver operating characteristic curve (AUC-ROC) of 0.73 [95% confidence interval (CI): 0.54-0.91], 0.74 (95% CI: 0.54-0.94) and 0.75 (95% CI: 0.57-0.94) respectively for E wave, PHT and IVRT. IVRT and PHT were significantly decreased, and E wave significantly increased, in case of histologically proven ACR. Inter-operator variability was not significant for E wave and IVRT measurements (P=0.13 and 0.30 respectively). Conclusions: Doppler echocardiography as a first-line method for surveillance of ACR did not impair long-term results after HT. These findings suggest that this non-invasive approach might be a reasonable alternative to systematic EMB, limiting risk and improving the quality of life.

3.
Circ Cardiovasc Interv ; 15(10): e012193, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36256693

RESUMO

BACKGROUND: Transcatheter closure of a symptomatic prosthetic paravalvular leak (PVL) is feasible, but there is presently no conclusive evidence to show consistent efficacy. We aimed to identify predictors of clinical success after transcatheter PVL closure. METHODS: Consecutive patients referred to 24 European centers for transcatheter PVL closure in 2017 to 2019 were included in a prospective registry (Fermeture de Fuite ParaProthétique, FFPP). Clinical success was absence of any of the following within 1 month: re-admission for heart failure, blood transfusion, open-heart valvular surgery, and death. RESULTS: We included 216 symptomatic patients, who underwent 238 percutaneous PVL closure procedures on the mitral (64.3%), aortic (34.0%), or tricuspid (1.7%) valve. Symptoms were heart failure, hemolytic anemia, or both in 48.9%, 7.8%, and 43.3% of patients, respectively. One, 2, and 3 leaks were treated during the same procedure in 69.6%, 26.6%, and 3.8% of patients, respectively. The PVL was pinpoint or involved 1/8 or 1/4 of the valve circumference in 18.6%, 52.4%, and 28.1% of cases, respectively. The most frequently used devices were the Vascular Plug 3, Ventricular Septal Defect Occluder, Vascular Plug 2, and Paravalvular Leak Device (45.0%, 16.6%, 14.2%, and 13.6% of cases, respectively). Successful device(s) implantation with leak reduction to ≤grade 2 was obtained in 85.0% of mitral and 91.4% of aortic procedures, respectively (P=0.164); with major periprocedural adverse event rates of 3.3% and 1.2%, respectively (P=0.371); and clinical success rates of 70.3% and 88.0%, respectively (P=0.004). By multivariate analysis, technical failure, mechanical valve, and hemolytic anemia were independently associated with absence of clinical success (odds ratios [95% CIs], 7.7 [2.0-25.0]; P=0.002; 3.6 [1.1-11.1]; P=0.036; and 3.7 [1.2-11.9]; P=0.025; respectively). CONCLUSIONS: Transcatheter PVL closure is efficient and safe in symptomatic patients but is associated with a lower clinical success rate in patients with hemolysis and/or a mechanical valve. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifiers: NCT05089136.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Sistema de Registros , Insuficiência Cardíaca/etiologia , Cateterismo Cardíaco , Falha de Prótese
5.
ESC Heart Fail ; 8(2): 1509-1521, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33619905

RESUMO

AIMS: Iron deficiency (ID) occurs in about 50% of patients with heart failure (HF). The European Society of Cardiology (ESC) recommends ID diagnostic testing in newly diagnosed patients with HF and during follow-up, with intravenous iron supplementation (IS) only recommended in patients with HF with reduced ejection fraction (HFrEF). This study aimed to assess prevalence, clinical characteristics, and application of ESC guidelines for ID and IS in patients with HF in the real-life clinical setting. METHODS AND RESULTS: The French transversal multicentre OFICSel registry (300 cardiologists) conducted in 2017 included patients hospitalized for HF at least once in the previous 5 years. Diverse adult patients were eligible including inpatients and outpatients and those with acute and chronic HF. Data were collected from cardiologists and patients using study-specific surveys. Data included demographic and clinical data, as well as HF and ID management data. Overall, 2822 patients, mainly male (69.3%) with a median age of 69 years (interquartile range 58-78), were included. A total of 1075 patients (38.1%) were tested for ID, with 364 (33.9%) diagnosed. Of these, 168 (46.2%) received IS: 128 (76.2%) intravenous IS and 40 (23.8%) oral. Among the 201 patients with HFrEF diagnosed with ID, 99 (49.3%) received IS: 79 (79.8%) intravenous IS and 20 (20.2%) oral. CONCLUSIONS: In clinical practice, only one-third of patients with HF had a diagnostic test for ID. In patients with ID with HFrEF, only 39.3% received intravenous IS as recommended. Thus, in general, cardiologists should be encouraged to follow the ESC guidelines to ensure optimal treatment for patients with HF.


Assuntos
Anemia Ferropriva , Insuficiência Cardíaca , Adulto , Idoso , Anemia Ferropriva/diagnóstico , Anemia Ferropriva/tratamento farmacológico , Anemia Ferropriva/epidemiologia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Humanos , Ferro , Masculino , Sistema de Registros , Volume Sistólico
6.
Clin Transplant ; 35(1): e14146, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33175401

RESUMO

Antihuman leukocyte antigen (HLA) antibodies restrict the access to cardiac allografts. Desensitization therapy is a major challenge in patients with cardiogenic shock waiting for urgent heart transplantation (HT). We retrospectively reviewed six patients (mean age of 37.5 years [16-70]) who underwent plasmapheresis (PP) under extracorporeal membrane oxygenation (ECMO) before transplant between January 2017 and September 2018. The average duration of follow-up was 25 months [20-32]. Mean fluorescence intensity (MFI) of HLA-specific antibodies was reported as follows: score 4 for MFI < 1000, score 6 for 1000 < MFI < 3000 and score 8 for MFI > 3000. The mean duration of ECMO support was 29 days [1-74] and 6.8 [1-29] PP sessions were performed per patient before transplant. The mean number of HLA-specific antibodies before HT was 9.6 for score 6 [4-13] and 5.8 for score 8 [1-12]. Four patients had major complications after transplantation (2 hemorrhagic shocks, 5 infectious events). Mean MFI reduction rate was 94% [79-100] for Class I and 44.2% for Class II [0-83]. Hospital survival was 100%, and early antibody-mediated rejection was diagnosed in one patient at 7 days after HT. Plasmapheresis under ECMO support was associated with favorable early outcomes in highly sensitized candidates for urgent heart transplantation.


Assuntos
Oxigenação por Membrana Extracorpórea , Transplante de Coração , Adulto , Antígenos HLA , Humanos , Estudos Retrospectivos , Choque Cardiogênico/terapia
7.
Eur J Cardiothorac Surg ; 58(1): 112-120, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32298439

RESUMO

OBJECTIVES: Our goal was to provide a picture of left ventricular assist device (LVAD) activity in France between 2007 and 2016 based on the multicentric ASSIST-ICD registry. METHODS: We retrospectively collected 136 variables including in-hospital data, follow-up survival rates and adverse events from 671 LVAD recipients at 20 out of 24 LVAD implant centres in France. The average follow-up time was 1.2 years (standard deviation: 1.4); the total follow-up time was 807.5 patient-years. RESULTS: The included devices were the HeartMate II®, HeartWare LVAS® or Jarvik 2000®. The overall likelihood of being alive while on LVAD support or having a transplant (primary end point) at 1, 2, 3 and 5 years postimplantation was 65.2%, 59.7%, 55.9% and 47.7%, respectively, given a cumulative incidence of 29.2% of receiving a transplant at year 5. At implantation, 21.5% of patients were on extracorporeal life support. The overall rate of cardiogenic shock at implantation was 53%. The major complications were driveline infection (26.1%), pump pocket or cannula infection (12.6%), LVAD thrombosis (12.2%), ischaemic (12.8%) or haemorrhagic stroke (5.4%; all strokes 18.2%), non-cerebral haemorrhage (9.1%) and LVAD exchange (5.2%). The primary end point (survival) was stratified by age at surgery and by the type of device used, with inference from baseline profiles. The primary end point combined with an absence of complications (secondary end point) was also stratified by device type. CONCLUSIONS: The ASSIST-ICD registry provides a real-life picture of LVAD use in 20 of the 24 implant centres in France. Despite older average age and a higher proportion of patients chosen for destination therapy, survival rates improved compared to those in previous national registry results. This LVAD registry contrasts with other international registries because patients with implants have more severe disease, and the national policy for graft attribution is distinct. We recommend referring patients for LVAD earlier and suggest a discussion of the optimal timing of a transplant for bridged patients (more dismal results after the second year of support?).


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , França/epidemiologia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
8.
J Artif Organs ; 23(2): 180-182, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31555999

RESUMO

We herein report an unusual life-threatening complication with the Hearmate 3 centrifugal ventricular assist device: proximal outflow graft extrinsic compression due to external thrombus leading to pump dysfunction and urgent heart transplantation. Low flow alarms without other abnormalities lead to the diagnosis of outflow occlusion. There was no evidence for a twist of the outflow graft, and no evidence for outflow thrombosis. The location of the outflow occlusion was particularly difficult to diagnose due to metallic artifacts around the pump. This report underscores that this complication should be screened in case of persistent low-flow alarms with the Heartmate 3 centrifugal pump.


Assuntos
Cardiomiopatias/cirurgia , Insuficiência Cardíaca/cirurgia , Transplante de Coração , Coração Auxiliar/efeitos adversos , Trombose/etiologia , Adulto , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento
10.
Arch Cardiovasc Dis ; 111(6-7): 421-431, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29937207

RESUMO

BACKGROUND: Percutaneous paravalvular leak (PVL) closure has emerged as a palliative alternative to surgical management in selected high-risk patients. Percutaneous procedures are challenging, especially for mitral PVL. Accurate imaging of the morphologies of the defects is mandatory, together with precise guidance in the catheterization laboratory to enhance success rates. AIMS: To describe imaging modalities used in clinical practice to guide percutaneous PVL closure and assess the potential of new imaging tools. METHODS: Data from the 'Fermeture de Fuite paraprothétique' (FFPP) register were used. The FFPP register is an international multi-institutional collaborative register started in 2017 with a retrospective and a prospective part. A descriptive analysis of multimodality imaging used to guide PVL closure in clinical practice was performed. RESULTS: Data from 173 procedures performed in 19 centres from three countries (France, Belgium and Poland) were collected, which included eight cases of PVL following transcatheter valve replacement. Transoesophageal echocardiography was used in 167 cases (96.5%) and 3D echocardiography in 87.4% of cases. In one case, 3D-echocardiography was fused with fluoroscopy images in real time using echonavigator software. Details about multimodality imaging were available from a sample of 31 patients. Cardiac computed tomography (CT) was performed before 10 of the procedures. In one case, fusion between preprocedural cardiac CT angiography data and fluoroscopy data was used. In two cases, a 3D model of the valve with PVL was printed. CONCLUSION: Echocardiography, particularly the 3D mode, is the cornerstone of PVL imaging. Other imaging modalities, such as cardiac CT and cardiac magnetic resonance imaging, may be of complementary interest. New techniques such as imaging fusion and printing may further facilitate the percutaneous approach of PVLs.


Assuntos
Insuficiência da Valva Aórtica/terapia , Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/terapia , Valva Mitral/cirurgia , Imagem Multimodal/métodos , Radiografia Intervencionista/métodos , Ultrassonografia de Intervenção/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Angiografia por Tomografia Computadorizada , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Europa (Continente) , Feminino , Fluoroscopia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Impressão Tridimensional , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA