Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Thorac Cardiovasc Surg ; 164(6): 1922-1930.e2, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-33581897

RESUMO

OBJECTIVE: Patients with a continuous-flow left ventricular assist device may show recovery of myocardial function with unloading. Identifying candidates for and predicting clinical and hemodynamic stability after left ventricular assist device explantation remain challenging. METHODS: Retrospective analysis of patients who underwent evaluation for left ventricular assist device explantation following a standardized protocol from January 2016 to March 2020. Patients who met screening criteria underwent echocardiography under "baseline," "minimal net flow," and "pump stop" conditions. If the protocol criteria were met, right heart catheterization with left ventricular assist device stoppage and occlusion of the outflow graft with a balloon catheter were performed. In patients with pulmonary capillary wedge pressure less than 16 mm Hg, explantation was performed under "pump stop" conditions. RESULTS: A total of 544 patients were screened. Of these, 57 (10.5%) underwent a total of 73 echocardiography under "baseline" "minimal net flow" and "pump stop" conditions and 46 underwent left ventricular assist device stoppage and occlusion of the outflow graft with balloon catheter maneuvers. Complications during the procedure were rare. Ultimately, 21 patients (3.9%) underwent explantation. The left ventricular ejection fraction at baseline was 55.5% ± 6.5%. The mean pulmonary capillary wedge pressure was 8.1 ± 2.6 mm Hg and increased to 10.7 ± 2.9 mm Hg under left ventricular assist device stoppage and occlusion of the outflow graft with a balloon catheter. A nonischemic cause of cardiomyopathy was more likely to be found in patients who underwent explantation (20/21 patients [95%], P = .020). The survival 1 year after explantation was 95.2%, with 1 death occurring 222 days after left ventricular assist device explantation. At follow-up (median 24.9 months [interquartile range, 16.4-43.1 months]), patients were in New York Heart Association class 1 (61.9%), 2 (28.6%), and 3 (9.5%). CONCLUSIONS: Our 4-year experience with a standardized protocol for left ventricular assist device explantation showed a low rate of adverse events. If all criteria are met, explantation can be performed safely and with an excellent survival and functional class.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Volume Sistólico , Função Ventricular Esquerda , Estudos Retrospectivos , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA