Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 18(2): e0279956, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36735683

RESUMO

BACKGROUND: Real-world performance of COVID-19 diagnostic tests under Emergency Use Authorization (EUA) must be assessed. We describe overall trends in the performance of serology tests in the context of real-world implementation. METHODS: Six health systems estimated the odds of seropositivity and positive percent agreement (PPA) of serology test among people with confirmed SARS-CoV-2 infection by molecular test. In each dataset, we present the odds ratio and PPA, overall and by key clinical, demographic, and practice parameters. RESULTS: A total of 15,615 people were observed to have at least one serology test 14-90 days after a positive molecular test for SARS-CoV-2. We observed higher PPA in Hispanic (PPA range: 79-96%) compared to non-Hispanic (60-89%) patients; in those presenting with at least one COVID-19 related symptom (69-93%) as compared to no such symptoms (63-91%); and in inpatient (70-97%) and emergency department (93-99%) compared to outpatient (63-92%) settings across datasets. PPA was highest in those with diabetes (75-94%) and kidney disease (83-95%); and lowest in those with auto-immune conditions or who are immunocompromised (56-93%). The odds ratios (OR) for seropositivity were higher in Hispanics compared to non-Hispanics (OR range: 2.59-3.86), patients with diabetes (1.49-1.56), and obesity (1.63-2.23); and lower in those with immunocompromised or autoimmune conditions (0.25-0.70), as compared to those without those comorbidities. In a subset of three datasets with robust information on serology test name, seven tests were used, two of which were used in multiple settings and met the EUA requirement of PPA ≥87%. Tests performed similarly across datasets. CONCLUSION: Although the EUA requirement was not consistently met, more investigation is needed to understand how serology and molecular tests are used, including indication and protocol fidelity. Improved data interoperability of test and clinical/demographic data are needed to enable rapid assessment of the real-world performance of in vitro diagnostic tests.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Estados Unidos/epidemiologia , COVID-19/diagnóstico , COVID-19/epidemiologia , Teste para COVID-19 , Técnicas de Laboratório Clínico/métodos , Testes Sorológicos
2.
PLoS One ; 18(2): e0281365, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36763574

RESUMO

BACKGROUND: As diagnostic tests for COVID-19 were broadly deployed under Emergency Use Authorization, there emerged a need to understand the real-world utilization and performance of serological testing across the United States. METHODS: Six health systems contributed electronic health records and/or claims data, jointly developed a master protocol, and used it to execute the analysis in parallel. We used descriptive statistics to examine demographic, clinical, and geographic characteristics of serology testing among patients with RNA positive for SARS-CoV-2. RESULTS: Across datasets, we observed 930,669 individuals with positive RNA for SARS-CoV-2. Of these, 35,806 (4%) were serotested within 90 days; 15% of which occurred <14 days from the RNA positive test. The proportion of people with a history of cardiovascular disease, obesity, chronic lung, or kidney disease; or presenting with shortness of breath or pneumonia appeared higher among those serotested compared to those who were not. Even in a population of people with active infection, race/ethnicity data were largely missing (>30%) in some datasets-limiting our ability to examine differences in serological testing by race. In datasets where race/ethnicity information was available, we observed a greater distribution of White individuals among those serotested; however, the time between RNA and serology tests appeared shorter in Black compared to White individuals. Test manufacturer data was available in half of the datasets contributing to the analysis. CONCLUSION: Our results inform the underlying context of serotesting during the first year of the COVID-19 pandemic and differences observed between claims and EHR data sources-a critical first step to understanding the real-world accuracy of serological tests. Incomplete reporting of race/ethnicity data and a limited ability to link test manufacturer data, lab results, and clinical data challenge the ability to assess the real-world performance of SARS-CoV-2 tests in different contexts and the overall U.S. response to current and future disease pandemics.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Estados Unidos/epidemiologia , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/epidemiologia , RNA , Pandemias , Teste para COVID-19
3.
NPJ Digit Med ; 5(1): 27, 2022 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-35260762

RESUMO

Diagnosis codes are used to study SARS-CoV2 infections and COVID-19 hospitalizations in administrative and electronic health record (EHR) data. Using EHR data (April 2020-March 2021) at the Yale-New Haven Health System and the three hospital systems of the Mayo Clinic, computable phenotype definitions based on ICD-10 diagnosis of COVID-19 (U07.1) were evaluated against positive SARS-CoV-2 PCR or antigen tests. We included 69,423 patients at Yale and 75,748 at Mayo Clinic with either a diagnosis code or a positive SARS-CoV-2 test. The precision and recall of a COVID-19 diagnosis for a positive test were 68.8% and 83.3%, respectively, at Yale, with higher precision (95%) and lower recall (63.5%) at Mayo Clinic, varying between 59.2% in Rochester to 97.3% in Arizona. For hospitalizations with a principal COVID-19 diagnosis, 94.8% at Yale and 80.5% at Mayo Clinic had an associated positive laboratory test, with secondary diagnosis of COVID-19 identifying additional patients. These patients had a twofold higher inhospital mortality than based on principal diagnosis. Standardization of coding practices is needed before the use of diagnosis codes in clinical research and epidemiological surveillance of COVID-19.

4.
medRxiv ; 2021 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-34013299

RESUMO

OBJECTIVE: Real-world data have been critical for rapid-knowledge generation throughout the COVID-19 pandemic. To ensure high-quality results are delivered to guide clinical decision making and the public health response, as well as characterize the response to interventions, it is essential to establish the accuracy of COVID-19 case definitions derived from administrative data to identify infections and hospitalizations. METHODS: Electronic Health Record (EHR) data were obtained from the clinical data warehouse of the Yale New Haven Health System (Yale, primary site) and 3 hospital systems of the Mayo Clinic (validation site). Detailed characteristics on demographics, diagnoses, and laboratory results were obtained for all patients with either a positive SARS-CoV-2 PCR or antigen test or ICD-10 diagnosis of COVID-19 (U07.1) between April 1, 2020 and March 1, 2021. Various computable phenotype definitions were evaluated for their accuracy to identify SARS-CoV-2 infection and COVID-19 hospitalizations. RESULTS: Of the 69,423 individuals with either a diagnosis code or a laboratory diagnosis of a SARS-CoV-2 infection at Yale, 61,023 had a principal or a secondary diagnosis code for COVID-19 and 50,355 had a positive SARS-CoV-2 test. Among those with a positive laboratory test, 38,506 (76.5%) and 3449 (6.8%) had a principal and secondary diagnosis code of COVID-19, respectively, while 8400 (16.7%) had no COVID-19 diagnosis. Moreover, of the 61,023 patients with a COVID-19 diagnosis code, 19,068 (31.2%) did not have a positive laboratory test for SARS-CoV-2 in the EHR. Of the 20 cases randomly sampled from this latter group for manual review, all had a COVID-19 diagnosis code related to asymptomatic testing with negative subsequent test results. The positive predictive value (precision) and sensitivity (recall) of a COVID-19 diagnosis in the medical record for a documented positive SARS-CoV-2 test were 68.8% and 83.3%, respectively. Among 5,109 patients who were hospitalized with a principal diagnosis of COVID-19, 4843 (94.8%) had a positive SARS-CoV-2 test within the 2 weeks preceding hospital admission or during hospitalization. In addition, 789 hospitalizations had a secondary diagnosis of COVID-19, of which 446 (56.5%) had a principal diagnosis consistent with severe clinical manifestation of COVID-19 (e.g., sepsis or respiratory failure). Compared with the cohort that had a principal diagnosis of COVID-19, those with a secondary diagnosis had a more than 2-fold higher in-hospital mortality rate (13.2% vs 28.0%, P<0.001). In the validation sample at Mayo Clinic, diagnosis codes more consistently identified SARS-CoV-2 infection (precision of 95%) but had lower recall (63.5%) with substantial variation across the 3 Mayo Clinic sites. Similar to Yale, diagnosis codes consistently identified COVID-19 hospitalizations at Mayo, with hospitalizations defined by secondary diagnosis code with 2-fold higher in-hospital mortality compared to those with a primary diagnosis of COVID-19. CONCLUSIONS: COVID-19 diagnosis codes misclassified the SARS-CoV-2 infection status of many people, with implications for clinical research and epidemiological surveillance. Moreover, the codes had different performance across two academic health systems and identified groups with different risks of mortality. Real-world data from the EHR can be used to in conjunction with diagnosis codes to improve the identification of people infected with SARS-CoV-2.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA