Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Front Surg ; 10: 1182094, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37215348

RESUMO

Introduction: Endoscopic vacuum therapy (EVT) has emerged as a promising treatment option for upper gastrointestinal wall defects, offering benefits such as evacuation of secretions and removal of wound debris by suction, and reduction and healing of wound cavities to improve clinical outcomes. In contrast, covered stents have a high rate of migration and lack functional drainage, while endoluminal EVT devices obstruct the GI tract. The VACStent is a novel device that combines the benefits of EVT and stent placement. Its design features a fully covered Nitinol-stent within a polyurethane sponge cylinder, enabling EVT while maintaining stent patency. Methods: This study analyzes the pooled data from three different prospective study cohorts to assess the safe practicality of VACStent placement, complete leak coverage, and effective suction-treatment of esophageal leaks. By pooling the data, the study aims to provide a broader base for analysis. Results: In total, trans-nasal derivation of the catheter, suction and drainage of secretion via vacuum pump were performed without any adversity. In the pooled study cohort of 92 VACStent applications, the mean stent indwelling time was 5.2 days (range 2-8 days) without any dislocation of the device. Removal of the VACStent was done without complication, in one case the sponge was lost but subsequently fully preserved. Minor local erosions and bleeding and one subsequent hemostasis were recorded unfrequently during withdrawal of the device (5.4%, 5/92) but no perforation or pressure ulcer. Despite a high heterogeneity regarding primary disease and pretreatments a cure rate of 76% (38/50 patients) could be achieved. Discussion: In summary, insertion and release procedure was regarded as easy and simple with a low potential of dislocation. The VACStent was well tolerated by the patient while keeping the drainage function of the sponge achieving directly a wound closure by continuous suction and improving the healing process. The implantation of the VACStent provides a promising new procedure for improved clinical treatment in various indications of the upper gastrointestinal wall, which should be validated in larger clinical studies.Clinical Trial Registration: Identifier [DRKS00016048 and NCT04884334].

2.
Surg Endosc ; 37(5): 3657-3668, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36639580

RESUMO

BACKGROUND: Endoscopic treatment of esophageal leaks, mostly by covered stents or endoscopic vacuum therapy (EVT), has largely improved the clinical outcome in the last decade. However, both techniques suffer from significant limitations. Covered stents are hampered by a high rate of migration and missing functional drainage, whereas endoluminal EVT devices are limited by obstruction of the GI tract. The new design of the VACStent makes it a fully covered stent within a polyurethane sponge cylinder, allowing EVT while stent passage is still open. Initial clinical applications have demonstrated the fundamental concept of the VACStent. METHOD: A prospective multicenter open-label study was performed with the primary endpoint safe practicality, complete leak coverage, and effective suction-treatment of esophageal leaks. Secondary endpoints were prevention of septic conditions, successful leak healing, and complications, in particular stent-migration, local erosions and bleeding. RESULTS: Fifteen patients with different, mostly postoperative anastomotic leaks were enrolled in three centers. A total of 41 VACStents were implanted. The mean number of VACStents per patient was 2.7, with a mean duration of VACStent treatment of 15 days. The primary endpoint was met in all VACStent applications (41/41 implants), resulting in a leak healing rate of 80% (12/15 patients). Septic episodes were prevented in 93% (14/15 patients) and there was no mortality. There were no severe device-related adverse events (SADE) nor significant local bleeding or erosion. Minor stent-dislocation and migration, respectively, was observed in 7%. Oral intake of liquids or food was documented in 87% (13/15 patients). One anastomotic stenosis was seen during follow-up. CONCLUSIONS: VACStent treatment is a safe and effective treatment in esophageal leaks which can be covered by the sponge cylinder. Its application was described as easy and resembling that of conventional GI stents, with an impressive clinical success rate comparable to EVT outcomes. The VACStent offers a new option for clinical treatment of critical situations in esophageal perforations and anastomotic sutureline failures.


Assuntos
Perfuração Esofágica , Tratamento de Ferimentos com Pressão Negativa , Humanos , Tratamento de Ferimentos com Pressão Negativa/efeitos adversos , Estudos Prospectivos , Esôfago/cirurgia , Endoscopia/efeitos adversos , Perfuração Esofágica/cirurgia , Stents/efeitos adversos , Fístula Anastomótica/terapia , Fístula Anastomótica/cirurgia , Resultado do Tratamento , Hemorragia , Estudos Retrospectivos
3.
Trials ; 20(1): 55, 2019 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-30651127

RESUMO

BACKGROUND: Inguinal hernia repair is one of the most common surgical operations globally; more than 20 million groin herniae are repaired annually worldwide. Recurrence after an inguinal hernia operation is a considerable clinical problem. Another remaining problem after hernia surgery is the occurrence of chronic pain. Up to now, the use of synthetic meshes is the standard procedure, but there is increasing evidence that biological meshes could be advantageous concerning the occurrence of chronic pain due to different postoperative remodeling, without the disadvantages of a life-long implant. We hypothesize that the use of a biological mesh reduces postoperative pain without being inferior in terms of recurrence rate compared with a synthetic mesh. METHODS/DESIGN: The trial compares possible the advantages of biological matrices to synthetic meshes in laparo-endoscopic inguinal hernia repair. Four hundred and ninety-six patients with primary bilateral inguinal herniae in 20 German hernia centers will be enrolled. Biological mesh is used for one of the bilateral herniae, the other side will be operated on with a synthetic mesh. Randomization will preset which side is repaired with which material and trial participants will not be informed about the location of each mesh type. The primary endpoints will be intensity of postoperative local pain and the incidence of recurrent hernia after 2 years. DISCUSSION: There is no reasonably sized trial that assesses the use of biological meshes in laparo-endoscopic inguinal hernia repair. Our self-controlled trial design allows a direct comparison of the two meshes with very few confounding factors as well as minimizing the exclusion criteria. As we compare CE-certified medical devices in their designated indication the medical risk is not different compared to routine clinical care. Due to the common nature of bilateral inguinal hernia, a high recruitment rate is achievable. Because guidelines for hernia repair have stressed the need for reliable data on the already frequent use of biological meshes, we can expect our trial to have a direct implication on hernia-repair standards. TRIAL REGISTRATION: German Clinical Trials Register, ID: DRKS00010178 . Registered on 16.June.2016. BIOLAP underwent full external peer review as part of the funding process with the German Research Foundation.


Assuntos
Hérnia Inguinal/cirurgia , Herniorrafia/instrumentação , Laparoscopia/instrumentação , Telas Cirúrgicas , Desenho de Equipamento , Alemanha , Hérnia Inguinal/diagnóstico por imagem , Herniorrafia/efeitos adversos , Herniorrafia/métodos , Humanos , Laparoscopia/efeitos adversos , Estudos Multicêntricos como Assunto , Dor Pós-Operatória/etiologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Recidiva , Fatores de Tempo , Resultado do Tratamento
4.
Cell Death Differ ; 21(7): 1050-60, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24531538

RESUMO

CD8(+) T-cell functions are critical for preventing chronic viral infections by eliminating infected cells. For healthy immune responses, beneficial destruction of infected cells must be balanced against immunopathology resulting from collateral damage to tissues. These processes are regulated by factors controlling CD8(+) T-cell function, which are still incompletely understood. Here, we show that the interferon regulatory factor 4 (IRF4) and its cooperating binding partner B-cell-activating transcription factor (BATF) are necessary for sustained CD8(+) T-cell effector function. Although Irf4(-/-) CD8(+) T cells were initially capable of proliferation, IRF4 deficiency resulted in limited CD8(+) T-cell responses after infection with the lymphocytic choriomeningitis virus. Consequently, Irf4(-/-) mice established chronic infections, but were protected from fatal immunopathology. Absence of BATF also resulted in reduced CD8(+) T-cell function, limited immunopathology, and promotion of viral persistence. These data identify the transcription factors IRF4 and BATF as major regulators of antiviral cytotoxic T-cell immunity.


Assuntos
Fatores de Transcrição de Zíper de Leucina Básica/fisiologia , Linfócitos T CD8-Positivos/fisiologia , Fatores Reguladores de Interferon/fisiologia , Vírus da Coriomeningite Linfocítica/imunologia , Animais , Apoptose , Linfócitos T CD8-Positivos/virologia , Células Cultivadas , Citotoxicidade Imunológica , Memória Imunológica , Ativação Linfocitária , Camundongos Endogâmicos C57BL , Camundongos Knockout
5.
Urologe A ; 49(11): 1401-5, 2010 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-20959951

RESUMO

Targeted therapies have helped to improve the quality of life and prolong the survival of many cancer patients. This progress is based on the growing understanding of cellular signal transduction pathways and regulatory systems in human cancers. In urothelial carcinoma, a number of specific alterations have been identified. These include mutations in FGFR3, HRAS, and PIK3CA leading to overactivity of MAPK and Akt signaling pathways especially in papillary tumors. In comparison, the RB1 and p53 regulatory systems that act more directly on cell cycle control are more commonly compromised in invasive carcinomas. Nevertheless, targeted therapies have shown little efficacy in the treatment of urothelial carcinoma so far, owing presumably to our incomplete knowledge of molecular changes affecting signal transduction pathways in this cancer type. Target genes of cancer pathways are regulated by epigenetic mechanisms, which determine their inducibility. Elucidating these control mechanisms could therefore prove important for developing targeted therapies for urothelial carcinoma.


Assuntos
Biomarcadores Tumorais/metabolismo , Modelos Biológicos , Proteínas de Neoplasias/metabolismo , Transdução de Sinais , Neoplasias Urológicas/metabolismo , Urotélio/metabolismo , Animais , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA