1.
Heart Rhythm ; 2024 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-39103135

RESUMO

BACKGROUND: The PRAETORIAN score is developed as an alternative for defibrillation testing (DFT) post subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation, and assess three aspects of implant position on a bidirectional chest X-ray. The score is validated on a standard standing chest X-ray with arms elevated in the lateral view. OBJECTIVE: We aim to evaluate the effect of different anatomical positions on the PRAETORIAN score. METHODS: Thirty S-ICD patients underwent standard posterior-anterior (PA) and lateral chest X-rays, including additional lateral views in two positions: standing with arms down and supine with arms alongside the body. PRAETORIAN score and weighted kappa coefficient were calculated for each position. RESULTS: In 8 out of 30 patients the PRAETORIAN score was ≥90 in standard position. The agreement in PRAETORIAN score was substantial (κ=0.677) for the position with the arms down and fair (κ =0.399) for the supine position. In 10 patients (33%) with the arms down the PRAETORIAN score decreased, of whom 4 changed to a lower risk category. In 16 patients (53%) the PRAETORIAN score decreased in supine position, of whom 7 changed to a lower risk category of which one patient changed from high to low risk. CONCLUSION: A supine or arms-down position during chest X-rays can result in lower PRAETORIAN scores and underestimation of associated risk on DFT failure. This emphasizes the importance of correct anatomical positioning ('arms up') during chest X-rays when using the PRAETORIAN score.

2.
Neth Heart J ; 2024 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-39158682

RESUMO

INTRODUCTION: Conventional implantable cardioverter-defibrillators (ICDs) and pacemakers carry a risk of pocket- and lead-related complications in particular. To avoid these complications, extravascular devices (EVDs) have been developed, such as the subcutaneous ICD (S-ICD) and leadless pacemaker (LP). However, data on patient or centre characteristics related to the actual adoption of EVDs are lacking. OBJECTIVE: To assess real-world nationwide trends in EVD adoption in the Netherlands. METHODS: Using the Netherlands Heart Registration, all consecutive patients with a de novo S­ICD or conventional single-chamber ICD implantation between 2012-2020, or de novo LP or conventional single-chamber pacemaker implantation between 2014-2020 were included. Trends in adoption are described for various patient and centre characteristics. RESULT: From 2012-2020, 2190 S­ICDs and 10,683 conventional ICDs were implanted; from 2014-2020, 712 LPs and 11,103 conventional pacemakers were implanted. The general use has increased (S-ICDs 8 to 21%; LPs 1 to 8%), but this increase seems to have reached a plateau. S­ICD recipients were younger than conventional ICD recipients (p < 0.001) and more often female (p < 0.001); LP recipients were younger than conventional pacemaker recipients (p < 0.001) and more often male (p = 0.03). Both S­ICDs and LPs were mainly implanted in high-volume centres with cardiothoracic surgery on-site, although over time S­ICDs were increasingly implanted in centres without cardiothoracic surgery (p < 0.001). CONCLUSION: This nationwide study demonstrated a relatively quick adoption of innovative EVDs with a plateau after approximately 4 years. S­ICD use is especially high in younger patients. EVDs are mainly implanted in high-volume centres with cardiothoracic surgery back-up, but S­ICD use is expanding beyond those centres.

3.
Circulation ; 150(6): 439-450, 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-38973458

RESUMO

BACKGROUND: A dual-chamber leadless pacemaker system has been designed for atrioventricular synchronous pacing using wireless, beat-to-beat, implant-to-implant (i2i) communication between distinct atrial and ventricular leadless pacemakers. The atrioventricular synchrony achieved across various ambulatory scenarios has yet to be systematically evaluated. METHODS: A prospective, single-arm, unblinded, multicenter, international clinical trial of the leadless pacemaker system was conducted in patients with a conventional dual-chamber pacing indication enrolled from February 2022 to March 2023. Leadless pacemaker systems were implanted, and 12-lead Holter electrocardiographic recordings were collected 3 months after implantation over various postures/activities: sitting, supine, left lateral recumbent, right lateral recumbent, standing, normal walk, and fast walk. An independent Holter core laboratory performed a manual adjudication of the percent of atrioventricular synchronous beats using the standard 300-millisecond PR interval limit. Atrium-to-ventricle and ventricle-to-atrium i2i communication success rates were also assessed. Post hoc summary statistics describing the relationships between atrioventricular synchrony and i2i success, posture/activity, implantation indication, atrioventricular event, and heart rate were calculated. RESULTS: In the evaluable population (n=384 of 464 enrolled [83%]; 61% male; age, 70 years; weight, 82 kg; 60% ejection fraction; 95% of beats evaluable), the mean atrioventricular synchrony of 98% of beats observed across all postures using the standard 300-millisecond limit was greater than both atrial-to-ventricular i2i (94%) and ventricular-to-atrial i2i (94%; P<0.001), exceeding both i2i values in 95% of patients. Atrioventricular synchrony was achieved in >95% of evaluable beats across all postures/activities, implantation indications, atrioventricular paced/sensed event combinations, and heart rate ranges (including >100 bpm). CONCLUSIONS: This dual-chamber leadless pacemaker system demonstrated atrioventricular synchrony in 98% of evaluable beats at 3 months after implantation. Atrioventricular synchrony was maintained across postures/activities and remained robust for heart rates >100 bpm.


Assuntos
Marca-Passo Artificial , Humanos , Masculino , Feminino , Idoso , Estudos Prospectivos , Idoso de 80 Anos ou mais , Frequência Cardíaca , Eletrocardiografia Ambulatorial , Pessoa de Meia-Idade , Estimulação Cardíaca Artificial/métodos
4.
Heart Rhythm ; 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38908460

RESUMO

The subcutaneous implantable cardioverter-defibrillator (S-ICD) has emerged as a feasible alternative to the transvenous ICD in the treatment of ventricular tachyarrhythmias in patients without indications for pacing or cardiac resynchronization therapy. Since its introduction, numerous innovations have been made and clinical experience has been gained, leading to its adoption in current practice and preference in certain populations. Moreover, emerging technologies like the extravascular ICD and the combination of the S-ICD with the leadless pacemaker offer new possibilities for the future. These advancements underscore the evolving role of the S-ICD in management of ventricular tachyarrhythmias. This review outlines implantation considerations, patient selection, and troubleshooting advancements in the last 15 years and provides insights into future perspectives.

5.
Sci Rep ; 14(1): 14889, 2024 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-38937555

RESUMO

The efficacy of an implantable cardioverter-defibrillator (ICD) in patients with a non-ischaemic cardiomyopathy for primary prevention of sudden cardiac death is increasingly debated. We developed a multimodal deep learning model for arrhythmic risk prediction that integrated late gadolinium enhanced (LGE) cardiac magnetic resonance imaging (MRI), electrocardiography (ECG) and clinical data. Short-axis LGE-MRI scans and 12-lead ECGs were retrospectively collected from a cohort of 289 patients prior to ICD implantation, across two tertiary hospitals. A residual variational autoencoder was developed to extract physiological features from LGE-MRI and ECG, and used as inputs for a machine learning model (DEEP RISK) to predict malignant ventricular arrhythmia onset. In the validation cohort, the multimodal DEEP RISK model predicted malignant ventricular arrhythmias with an area under the receiver operating characteristic curve (AUROC) of 0.84 (95% confidence interval (CI) 0.71-0.96), a sensitivity of 0.98 (95% CI 0.75-1.00) and a specificity of 0.73 (95% CI 0.58-0.97). The models trained on individual modalities exhibited lower AUROC values compared to DEEP RISK [MRI branch: 0.80 (95% CI 0.65-0.94), ECG branch: 0.54 (95% CI 0.26-0.82), Clinical branch: 0.64 (95% CI 0.39-0.87)]. These results suggest that a multimodal model achieves high prognostic accuracy in predicting ventricular arrhythmias in a cohort of patients with non-ischaemic systolic heart failure, using data collected prior to ICD implantation.


Assuntos
Arritmias Cardíacas , Cardiomiopatias , Desfibriladores Implantáveis , Eletrocardiografia , Imageamento por Ressonância Magnética , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Cardiomiopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Idoso , Inteligência Artificial , Aprendizado Profundo , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Medição de Risco/métodos , Fatores de Risco , Curva ROC
6.
Heart Rhythm ; 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38697271

RESUMO

BACKGROUND: The first dual-chamber leadless pacemaker (DC-LP) system consists of 2 separate atrial and ventricular devices that communicate to maintain synchronous atrioventricular pacing and sensing. The initial safety and efficacy were previously reported. OBJECTIVE: The purpose of this study was to evaluate the chronic electrical performance of the DC-LP system. METHODS: Patients meeting standard dual-chamber pacing indications were enrolled and implanted with the DC-LP system (Aveir DR, Abbott), including right atrial and ventricular helix-fixation LPs (atrial leadless pacemaker [ALP], ventricular leadless pacemaker [VLP]). Pacing capture threshold, sensed amplitude, and pacing impedance were collected using the device programmer at prespecified timepoints from 0-6 months postimplant. RESULTS: De novo devices were successfully implanted in 381 patients with complete 6-month data (62% male; age 69 ± 14 years; weight 82 ± 20 kg; 65% sinus nodal dysfunction, 30% atrioventricular block). ALPs were implanted predominantly in the right atrial appendage anterior base and VLPs primarily at the mid-to-apical right ventricular septum. From implant to 1 month, pacing capture thresholds (0.4-ms pulse width) improved in both ALPs (2.4 ± 1.5 V to 0.8 ± 0.8 V; P <.001) and VLPs (0.8 ± 0.6 V to 0.6 ± 0.4 V; P <.001). Sensed amplitudes improved in both ALPs (1.8 ± 1.3 mV to 3.4 ± 1.9 mV; P <.001) and VLPs (8.8 ± 4.0 mV to 11.7 ± 4.2 mV; P <.001). Impedances were stable in ALPs (334 ± 68 Ω to 329 ± 52 Ω; P = .17) and reduced in VLPs (789 ± 351 Ω to 646 ± 190 Ω; P <.001). Electrical measurements remained relatively stable from 1-6 months postimplant. No differences in electrical metrics were observed among ALP or VLP implant locations. CONCLUSION: This first in-human evaluation of the new dual-chamber leadless pacemaker system demonstrated reliable electrical performance throughout the initial 6-month evaluation period.

8.
N Engl J Med ; 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38767244

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. METHODS: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). RESULTS: We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. CONCLUSIONS: The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).

9.
Cardiovasc Digit Health J ; 5(2): 78-84, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38765619

RESUMO

Background: Remote monitoring devices for atrial fibrillation are known to positively contribute to the diagnostic process and therapy compliance. However, automatic algorithms within devices show varying sensitivity and specificity, so manual double-checking of electrocardiographic (ECG) recordings remains necessary. Objective: The purpose of this study was to investigate the validity of the KardiaMobile algorithm within the Dutch telemonitoring program (HartWacht). Methods: This retrospective study determined the diagnostic accuracy of the algorithm using assessments by a telemonitoring team as reference. The sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), and F1 scores were determined. Results: A total of 2298 patients (59.5% female; median age 57 ± 15 years) recorded 86,816 ECGs between April 2019 and January 2021. The algorithm showed sensitivity of 0.956, specificity 0.985, PPV 0.996, NPV 0.847, and F1 score 0.976 for the detection of sinus rhythm. A total of 29 false-positive outcomes remained uncorrected within the same patients. The algorithm showed sensitivity of 0.989, specificity 0.953, PPV 0.835, NPV 0.997, and F1 score 0.906 for detection of atrial fibrillation. A total of 2 false-negative outcomes remained uncorrected. Conclusion: Our research showed high validity of the algorithm for the detection of both sinus rhythm and, to a lesser extent, atrial fibrillation. This finding suggests that the algorithm could function as a standalone instrument particularly for detection of sinus rhythm.

10.
Heart Rhythm O2 ; 5(3): 182-188, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38560377

RESUMO

Background: Recent studies suggest that participation in recreational and even competitive sports is generally safe for patients with implantable cardioverter-defibrillators (ICDs). However, these studies included only patients with implanted transvenous ICD (TV-ICD). Nowadays, subcutaneous ICD (S-ICD) is a safe and effective alternative and is increasingly implanted in younger ICD candidates. Data on the safety of sport participation for patients with implanted S-ICD systems is urgently needed. Objectives: The goal of the study is to quantify the risks (or determine the safety) of sports participation for athletes with an S-ICD, which will guide shared decision making for athletes requiring an ICD and/or wishing to return to sports after implantation. Methods: The SPORT S-ICD (Sports for Patients with Subcutaneous Implantable Cardioverter Defibrillator) study is an international, multicenter, prospective, noninterventional, observational study, designed specifically to collect data on the safety of sports participation among patients with implanted S-ICD systems who regularly engage in sports activities. Results: A total of 450 patients will undergo baseline assessment including baseline characteristics, indication for S-ICD implantation, arrhythmic history, S-ICD data and programming, and data regarding sports activities. LATITUDE Home Monitoring information will be regularly transferred to the study coordinator for analysis. Conclusion: The results of the study will aid in shaping clinical decision making, and if the tested hypothesis will be proven, it will allow the safe continuation of sports for patients with an implanted S-ICD.

11.
BJOG ; 131(9): 1290-1295, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38326282

RESUMO

OBJECTIVE: Data and guidelines are lacking, so implantable cardioverter-defibrillators (ICDs) are often deactivated during labour to prevent inappropriate shocks. This study aimed to ascertain the safety of an activated ICD during labour. DESIGN: An observational study was performed. SETTING: Dutch hospitals. POPULATION OR SAMPLE: A total of 41 childbirths were included of 26 patients who gave birth between February 2009 and November 2018 after receiving an ICD in our tertiary hospital. Five of these childbirths were attended by the research team between December 2018 and August 2020, during which the ICD remained active. METHODS: Groups were made based on ICD status during labour. Patients who gave birth with an activated ICD at least once were stratified to the activated ICD group. Patients' files were checked and patients received a questionnaire about childbirth perceptions and treatment preferences. The differences in ordinal data resulting from the questionnaire were calculated using a chi-square or Fisher's exact test. MAIN OUTCOME MEASURES: Primary outcome was inappropriate ICD therapy and occurrence of ventricular arrhythmias requiring treatment. RESULTS: During the 41 childbirths, no inappropriate shocks or ventricular arrhythmias occurred during labour. All patients in the activated ICD group (n = 13) preferred this setting, while 8 of the 13 patients in the deactivated ICD group preferred activation (p = 0.002). Reasons included avoiding hemodynamic monitoring, magnet placement, or labour induction to facilitate technician availability. CONCLUSIONS: This study shows no evidence that labour and birth in women with an activated ICD are unsafe, as there were no ventricular arrhythmias or inappropriate therapy. In addition, most patients prefer an activated ICD during labour.


Assuntos
Desfibriladores Implantáveis , Humanos , Feminino , Desfibriladores Implantáveis/efeitos adversos , Adulto , Gravidez , Países Baixos , Arritmias Cardíacas/terapia , Trabalho de Parto , Inquéritos e Questionários , Segurança do Paciente , Parto , Complicações Cardiovasculares na Gravidez/terapia
12.
Heart Rhythm ; 21(6): 836-844, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38336193

RESUMO

BACKGROUND: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. OBJECTIVE: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. METHODS: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. RESULTS: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13-279.95; P < .001). CONCLUSION: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Valor Preditivo dos Testes , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Cardioversão Elétrica/métodos , Estudos Prospectivos , Idoso , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Medição de Risco/métodos , Taquicardia Ventricular/terapia , Taquicardia Ventricular/fisiopatologia , Fibrilação Ventricular/terapia
14.
EBioMedicine ; 99: 104937, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38118401

RESUMO

BACKGROUND: Risk stratification for ventricular arrhythmias currently relies on static measurements that fail to adequately capture dynamic interactions between arrhythmic substrate and triggers over time. We trained and internally validated a dynamic machine learning (ML) model and neural network that extracted features from longitudinally collected electrocardiograms (ECG), and used these to predict the risk of malignant ventricular arrhythmias. METHODS: A multicentre study in patients implanted with an implantable cardioverter-defibrillator (ICD) between 2007 and 2021 in two academic hospitals was performed. Variational autoencoders (VAEs), which combine neural networks with variational inference principles, and can learn patterns and structure in data without explicit labelling, were trained to encode the mean ECG waveforms from the limb leads into 16 variables. Supervised dynamic ML models using these latent ECG representations and clinical baseline information were trained to predict malignant ventricular arrhythmias treated by the ICD. Model performance was evaluated on a hold-out set, using time-dependent receiver operating characteristic (ROC) and calibration curves. FINDINGS: 2942 patients (61.7 ± 13.9 years, 25.5% female) were included, with a total of 32,129 ECG recordings during a mean follow-up of 43.9 ± 35.9 months. The mean time-varying area under the ROC curve for the dynamic model was 0.738 ± 0.07, compared to 0.639 ± 0.03 for a static (i.e. baseline-only model). Feature analyses indicated dynamic changes in latent ECG representations, particularly those affecting the T-wave morphology, were of highest importance for model predictions. INTERPRETATION: Dynamic ML models and neural networks effectively leverage routinely collected longitudinal ECG recordings for personalised and updated predictions of malignant ventricular arrhythmias, outperforming static models. FUNDING: This publication is part of the project DEEP RISK ICD (with project number 452019308) of the research programme Rubicon which is (partly) financed by the Dutch Research Council (NWO). This research is partly funded by the Amsterdam Cardiovascular Sciences (personal grant F.V.Y.T).


Assuntos
Desfibriladores Implantáveis , Humanos , Feminino , Masculino , Morte Súbita Cardíaca , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Eletrocardiografia , Redes Neurais de Computação
16.
N Engl J Med ; 389(11): 1056-1057, 2023 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-37703567
17.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37712675

RESUMO

AIMS: Left ventricular ejection fraction (LVEF) is suboptimal as a sole marker for predicting sudden cardiac death (SCD). Machine learning (ML) provides new opportunities for personalized predictions using complex, multimodal data. This study aimed to determine if risk stratification for implantable cardioverter-defibrillator (ICD) implantation can be improved by ML models that combine clinical variables with 12-lead electrocardiograms (ECG) time-series features. METHODS AND RESULTS: A multicentre study of 1010 patients (64.9 ± 10.8 years, 26.8% female) with ischaemic, dilated, or non-ischaemic cardiomyopathy, and LVEF ≤ 35% implanted with an ICD between 2007 and 2021 for primary prevention of SCD in two academic hospitals was performed. For each patient, a raw 12-lead, 10-s ECG was obtained within 90 days before ICD implantation, and clinical details were collected. Supervised ML models were trained and validated on a development cohort (n = 550) from Hospital A to predict ICD non-arrhythmic mortality at three-year follow-up (i.e. mortality without prior appropriate ICD-therapy). Model performance was evaluated on an external patient cohort from Hospital B (n = 460). At three-year follow-up, 16.0% of patients had died, with 72.8% meeting criteria for non-arrhythmic mortality. Extreme gradient boosting models identified patients with non-arrhythmic mortality with an area under the receiver operating characteristic curve (AUROC) of 0.90 [95% confidence intervals (CI) 0.80-1.00] during internal validation. In the external cohort, the AUROC was 0.79 (95% CI 0.75-0.84). CONCLUSIONS: ML models combining ECG time-series features and clinical variables were able to predict non-arrhythmic mortality within three years after device implantation in a primary prevention population, with robust performance in an independent cohort.


Assuntos
Desfibriladores Implantáveis , Humanos , Feminino , Masculino , Seleção de Pacientes , Volume Sistólico , Função Ventricular Esquerda , Aprendizado de Máquina , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Prevenção Primária
18.
Circ Arrhythm Electrophysiol ; 16(10): e012232, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37767710

RESUMO

BACKGROUND: The clinical utilization of leadless pacemakers (LPs) as an alternative to traditional transvenous pacemakers is likely to increase with the advent of dual-chamber LP systems. Since device retrieval to allow LP upgrade or replacement will become an important capability, the first such dual-chamber, helix-fixation LP system (Aveir DR; Abbott, Abbott Park, IL) was specifically designed to allow catheter-based retrieval. In this study, the preclinical performance and safety of retrieving chronically implanted dual-chamber LPs was evaluated. METHODS: Atrial and ventricular LPs were implanted in the right atrial appendage and right ventricular apex of 9 healthy ovine subjects. After ≈2 years, the LPs were retrieved using a dedicated transvenous retrieval catheter (Aveir Retrieval Catheter; Abbott) by snaring, docking, and unscrewing from the myocardium. Comprehensive necropsy/histopathology studies were conducted to evaluate device- and procedure-related outcomes. RESULTS: At a median of 1.9 years postimplant (range, 1.8-2.6), all 18 of 18 (100%) LPs were retrieved from 9 ovine subjects without complications. The median retrieval procedure duration for both LPs, from first-catheter-in to last-catheter-out, was 13.3 minutes (range, 2.5-36.4). Postretrieval, all right atrial, and right ventricular implant sites demonstrated minimal tissue disruption, with intact fibrous tissue limited to the distal device body. No significant device-related trauma, perforation, pericardial effusion, right heart or tricuspid valve injury, or chronic pulmonary thromboembolism were observed at necropsy. CONCLUSIONS: This preclinical study demonstrated the safe and effective retrieval of chronically implanted, helix-fixation, dual-chamber LP systems, paving the way for clinical studies of LP retrieval.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Humanos , Ovinos , Animais , Lipopolissacarídeos , Carneiro Doméstico , Ventrículos do Coração , Desenho de Equipamento
19.
Circ Arrhythm Electrophysiol ; 16(8): 421-432, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37582163

RESUMO

BACKGROUND: This study assessed safety and feasibility of a novel extravascular implantable cardioverter defibrillator (ICD) lead when inserted anteriorly through a rib space and connected to various commercially available ICD pulse generators (PGs) placed in either a left mid-axillary or left pectoral pocket. Currently available or investigational, extravascular-ICDs include a subcutaneous or subxiphoid lead connected to customized extravascular-ICD PGs. METHODS: This novel extravascular-ICD (AtaCor Medical Inc, San Clemente, CA) employs a unique intercostal implant technique and is designed to function with commercial DF-4 ICD PGs. In this nonrandomized, single-center, acute study, 36 de novo or replacement ICD (transvenous ICD) patients enrolled to receive a concomitant extravascular-ICD lead inserted through an intercostal space along the left parasternal margin. extravascular-ICD leads were connected to DF-4 compatible ICD PGs positioned in either a left mid-axillary or pectoral pocket for acute sensing and defibrillation testing. Defibrillation testing started at 30 Joules (J) and stepped up or down in 5 to 10 joule increments depending on the success and limitations of the generator used. RESULTS: Successful acute defibrillation using ≤35 J was noted in 100% of left mid-axillary PG subjects (n=27, mean 16.3±8.6 J) and 83% of left pectoral PG subjects (n=6, mean 21.0±8.4 J). Furthermore, 24 of 27 (89%) of patients tested with a left, mid-axillary intermuscular PG had successful VF conversion with defibrillation energies at least 10 J below the maximum delivered output of the device. All evaluable episodes (n=93) were automatically sensed, detected, and shocked. No serious device-related intraoperative adverse events were observed. CONCLUSIONS: This first-in-human study documented the safe and reliable placement of a novel extravascular ICD lead with effective sensing and defibrillation of induced ventricular fibrillation using commercial DF-4 ICD PGs.


Assuntos
Desfibriladores Implantáveis , Humanos , Fibrilação Ventricular , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia
20.
Heart Rhythm ; 20(12): 1649-1656, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37579867

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) delivers 80 J shocks from an 8 cm left-parasternal coil to a 59 cm3 left lateral pulse generator (PG). A system that defibrillates with lower energy could significantly reduce PG size. Computer modeling and animal studies suggested that a second shock coil either parallel to the left-parasternal coil or transverse from the xiphoid to the PG pocket would significantly reduce the defibrillation threshold. OBJECTIVE: The purpose of this study was to acutely assess the defibrillation efficacy of parallel and transverse configurations in patients receiving an S-ICD. METHODS: Testing was performed in patients receiving a conventional S-ICD system. Success at 65 J was required before investigational testing. A second electrode was temporarily inserted from the xiphoid incision connected to the PG with an investigational Y-adapter. Phase 1 (n = 11) tested the parallel configuration. Phase 2 (n = 21) tested both parallel and transverse configurations in random order. RESULTS: This study enrolled 35 patients (28 males (80%); mean age 51 ± 17 years; left ventricular ejection fraction 40% ± 15%; body mass index 26 ± 4 kg/m2; prior myocardial infarction 46%; congestive heart failure 49%; cardiomyopathy 63%). Compared to the conventional S-ICD system, mean shock impedance decreased for both parallel (69 ± 15 Ω vs 86 ± 20 Ω; n = 33; P < .001) and transverse (56 ± 14 Ω vs 81 ± 21 Ω; n = 20; P < .001) configurations. Shock success rates at 20, 30, and 40 J were 55%, 79%, 97%, and 25%, 70%, 90% for parallel and transverse configurations, respectively. Defibrillation threshold testing was well tolerated with no serious adverse events. CONCLUSION: Adding a second shock coil, particularly in the parallel configuration, significantly reduced the impedance and had a high likelihood of defibrillation success at energies ≤40 J. This may enable the development of a smaller S-ICD.


Assuntos
Cardiomiopatias , Desfibriladores Implantáveis , Adulto , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Índice de Massa Corporal , Cardiomiopatias/etiologia , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Volume Sistólico , Fibrilação Ventricular/etiologia , Função Ventricular Esquerda