2.
J Am Heart Assoc ; 13(20): e036921, 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-39392163

RESUMO

BACKGROUND: Genetic testing is a cornerstone in the assessment of many cardiac diseases. However, variants are frequently classified as variants of unknown significance, limiting the utility of testing. Recently, the DeepMind group (Google) developed AlphaMissense, a unique artificial intelligence-based model, based on language model principles, for the prediction of missense variant pathogenicity. We aimed to report on the performance of AlphaMissense, accessed by VarCardio, an open web-based variant annotation engine, in a real-world cardiovascular genetics center. METHODS AND RESULTS: All genetic variants from an inherited arrhythmia program were examined using AlphaMissense via VarCard.io and compared with the ClinVar variant classification system, as well as another variant classification platform (Franklin by Genoox). The mutation reclassification rate and genotype-phenotype concordance were examined for all variants in the study. We included 266 patients with heritable cardiac diseases, harboring 339 missense variants. Of those, 230 (67.8%) were classified by ClinVar as either variants of unknown significance or nonclassified. Using VarCard.io, 198 variants of unknown significance (86.1%, 95% CI, 80.9-90.3) were reclassified to either likely pathogenic or likely benign. The reclassification rate was significantly higher for VarCard.io than for Franklin (86.1% versus 34.8%, P<0.001). Genotype-phenotype concordance was highly aligned using VarCard.io predictions, at 95.9% (95% CI, 92.8-97.9) concordance rate. For 109 variants classified as pathogenic, likely pathogenic, benign, or likely benign by ClinVar, concordance with VarCard.io was high (90.5%). CONCLUSIONS: AlphaMissense, accessed via VarCard.io, may be a highly efficient tool for cardiac genetic variant interpretation. The engine's notable performance in assessing variants that are classified as variants of unknown significance in ClinVar demonstrates its potential to enhance cardiac genetic testing.


Assuntos
Mutação de Sentido Incorreto , Humanos , Predisposição Genética para Doença , Cardiopatias/genética , Fenótipo , Bases de Dados Genéticas , Testes Genéticos/métodos , Anotação de Sequência Molecular , Variação Genética , Inteligência Artificial
3.
Am Heart J Plus ; 44: 100421, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39070127

RESUMO

Background: Catheter ablation (CA) for ventricular tachycardia (VT) can be a useful treatment strategy, however, few studies have compared CA to medical therapy (MT) in the sarcoidosis population. Objective: To assess in-hospital outcomes and unplanned readmissions following CA for VT compared to MT in patients with sarcoidosis. Methods: Data was obtained from the Nationwide Readmissions Database between 2010 and 2019 to identify patients with sarcoidosis admitted for VT either undergoing CA or MT during elective and non-elective admission. Primary endpoints were a composite endpoint of inpatient mortality, cardiogenic shock, cardiac arrest and 30-day hospital readmissions. Procedural complications at index admission and causes of readmission were also identified. Results: Among 1581 patients, 1217 with sarcoidosis and VT underwent MT compared to 168 with CA during non-elective admission. 63 patients admitted electively underwent CA compared with 129 managed medically. There was no difference in the composite outcome for patients undergoing catheter ablation or medical therapy during both non-elective (9.0 % vs 12.0 %, p = 0.312) and elective admission (3.2 % vs. 7.8 %, p = 0.343). The most common cause of readmission were ventricular arrhythmias (VA) in both groups, however, those undergoing elective CA were less likely to be readmitted for VA compared to non-elective CA. The most common complication in the CA group was cardiac tamponade (4.8 %). Conclusion: VT ablation is associated with similar rates of 30-day readmission compared to MT and does not confer increased risk of harm with respect to inpatient mortality, cardiogenic shock or cardiac arrest. Further research is warranted to determine if a subgroup of sarcoidosis patients admitted with VT are better served with an initial conservative management strategy followed by VT ablation.

4.
Heart Rhythm ; 21(8): 1308-1316, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-38490597

RESUMO

BACKGROUND: Many patients with mildly to moderately reduced left ventricular ejection fraction (LVEF) who require permanent pacemaker (PPM) implantation do not have a concurrent indication for implantable cardioverter-defibrillator (ICD) therapy. However, the risk of ventricular tachycardia/ventricular fibrillation (VT/VF) in this population is unknown. OBJECTIVE: The aim of this study was to describe the risk of VT/VF after PPM implantation in patients with mildly to moderately reduced LVEF. METHODS: Retrospective analysis was performed of 243 patients with LVEF between 35% and 49% who underwent PPM placement and did not meet indications for an ICD. The primary end point was occurrence of sustained VT/VF. Competing risks regression was performed to calculate subhazard ratios for the primary end point. RESULTS: Median follow-up was 27 months; 73% of patients were male, average age was 79 ± 10 years, average LVEF was 42% ± 4%, and 70% were New York Heart Association class II or above. Most PPMs were implanted for sick sinus syndrome (34%) or atrioventricular block (50%). Of 243 total patients, 11 (4.5%) met the primary end point of VT/VF. Multivessel coronary artery disease (CAD) was associated with significantly higher rates of VT/VF, with a subhazard ratio of 5.4 (95% CI, 1.5-20.1; P = .01). Of patients with multivessel CAD, 8 of 82 (9.8%) patients met the primary end point for an annualized risk of 4.3% per year. CONCLUSION: Patients with mildly to moderately reduced LVEF and multivessel CAD undergoing PPM implantation are at increased risk for the development of malignant ventricular arrhythmias. Patients in this population may benefit from additional risk stratification for VT/VF and consideration for upfront ICD implantation.


Assuntos
Marca-Passo Artificial , Volume Sistólico , Taquicardia Ventricular , Humanos , Masculino , Feminino , Volume Sistólico/fisiologia , Idoso , Estudos Retrospectivos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Seguimentos , Medição de Risco/métodos , Fatores de Risco , Desfibriladores Implantáveis , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/terapia , Função Ventricular Esquerda/fisiologia , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/terapia
6.
J Interv Card Electrophysiol ; 67(1): 203-210, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36952090

RESUMO

OBJECTIVES: We investigated characteristics of left atrial conduction in patients with HCM, paroxysmal AF and normal bipolar voltage. BACKGROUND: Patients with hypertrophic cardiomyopathy (HCM) exhibit abnormal cardiac tissue arrangement. The incidence of atrial fibrillation (AF) is increased fourfold in patients with HCM and confers a fourfold increased risk of death. Catheter ablation is less effective in HCM, with twofold increased risk of AF recurrence. The mechanisms of AF perpetuation in HCM are poorly understood. METHODS: We analyzed 20 patients with HCM and 20 controls presenting for radiofrequency ablation of paroxysmal AF normal left atrial voltage(> 0.5 mV). Intracardiac electrograms were extracted from the CARTO mapping system and analyzed using Matlab/Python code interfacing with Core OpenEP software. Conduction velocity maps were calculated using local activation time gradients. RESULTS: There were no differences in baseline demographics, atrial size, or valvular disease between HCM and control patients. Patients with HCM had significantly reduced atrial conduction velocity compared to controls (0.44 ± 0.17 vs 0.56 ± 0.10 m/s, p = 0.01), despite no significant differences in bipolar voltage amplitude (1.23 ± 0.38 vs 1.20 ± 0.41 mV, p = 0.76). There was a statistically significant reduction in conduction velocity in the posterior left atrium in HCM patients relative to controls (0.43 ± 0.18 vs 0.58 ± 0.10 m/s, p = 0.003), but not in the anterior left atrium (0.46 ± 0.17 vs 0.55 ± 0.10 m/s, p = 0.05). There was a significant association between conduction velocity and interventricular septal thickness (slope = -0.013, R2 = 0.13, p = 0.03). CONCLUSIONS: Atrial conduction velocity is significantly reduced in patients with HCM and paroxysmal AF, possibly contributing to arrhythmia persistence after catheter ablation.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cardiomiopatia Hipertrófica , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/cirurgia , Cardiomiopatia Hipertrófica/complicações , Apêndice Atrial/cirurgia , Ablação por Cateter/efeitos adversos
7.
J Cardiovasc Electrophysiol ; 34(4): 942-946, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36738141

RESUMO

INTRODUCTION: Radiofrequency ablation (RFA) slow pathway modification for catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT) is traditionally performed using a 4-mm nonirrigated (NI) RF ablation catheter. Slow pathway modification using irrigated, contact-force sensing (ICFS) RFA catheters has been described in case reports, but the outcomes have not been systematically evaluated. METHODS: Acute procedural outcomes of 200 consecutive patients undergoing slow pathway modification for AVNRT were analyzed. A 3.5-mm ICFS RFA catheter (ThermoCool SmartTouch STSF, Biosense Webster, Inc.) was utilized in 134 patients, and a 4-mm NI RFA catheter (EZ Steer, Biosense Webster, Inc.) was utilized in 66 patients. Electroanatomic maps were retrospectively analyzed in a blinded fashion to determine the proximity of ablation lesions to the His region. RESULTS: The baseline characteristics of patients in both groups were similar. Total RF time was significantly lower in the ICFS group compared to the NI group (5.53 ± 4.6 vs. 6.24 ± 4.9 min, p = 0.03). Median procedure time was similar in both groups (ICFS, 108.0 (87.5-131.5) min vs. NI, 100.0 (85.0-125.0) min; p = 0.2). Ablation was required in closer proximity to the His region in the NI group compared to the ICFS group (14.4 ± 5.9 vs. 16.7 ± 6.4 mm, respectively, p = 0.01). AVNRT was rendered noninducible in all patients, and there was no arrhythmia recurrence during follow-up in both groups. Catheter ablation was complicated by AV block in one patient in the NI group. CONCLUSION: Slow pathway modification for catheter ablation of AVNRT using an ICFS RFA catheter is feasible, safe, and may facilitate shorter duration ablation while avoiding ablation in close proximity to the His region.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Taquicardia por Reentrada no Nó Atrioventricular , Humanos , Estudos Retrospectivos , Catéteres
8.
J Cardiovasc Electrophysiol ; 34(4): 800-807, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36738147

RESUMO

INTRODUCTION: Radiofrequency ablation technology for treating atrial fibrillation (AF) has evolved rapidly over the past decade. We investigated the impact of technological and procedural advances on procedure times and ablation outcomes at a major academic medical center over a 10-year period. METHODS: Clinical data was collected from patients who presented to NYU Langone Health between 2011 and 2021 for a first-time AF ablation. Time to redo AF ablation or direct current cardioversion (DCCV) for recurrent AF during a 3-year follow-up period was determined and correlated with ablation technology and practices, antiarrhythmic medications, and patient comorbid conditions. RESULTS: From 2011 to 2021, the cardiac electrophysiology lab adopted irrigated-contact force ablation catheters, high-power short duration ablation lesions, steady-pacing, jet ventilation, and eliminated stepwise linear ablation for AF ablation. During this time the number of first time AF ablations increased from 403 to 1074, the percentage of patients requiring repeat AF-related intervention within 3-years of the index procedure dropped from 22% to 14%, mean procedure time decreased from 271 ± 65 to 135 ± 36 min, and mean annual major adverse event rate remained constant at 1.1 ± 0.5%. Patient comorbid conditions increased during this time period and antiarrhythmic use was unchanged. CONCLUSION: Rates of redo-AF ablation or DCCV following an initial AF ablation at a single center decreased 36% over a 10-year period. Procedural and technological changes likely contributed to this improvement, despite increased AF related comorbidities.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Antiarrítmicos/uso terapêutico , Fatores de Tempo , Ablação por Cateter/métodos
9.
J Cardiovasc Electrophysiol ; 34(3): 575-582, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36511474

RESUMO

INTRODUCTION: Patients with HIV infection have increased risk of atrial fibrillation, but the pathophysiologic mechanisms and the utility of catheter ablation in this population are not well-studied. We aimed to characterize outcomes of atrial fibrillation ablation and left atrial substrate in patients with HIV. METHODS: The study was a retrospective propensity score-matched analysis of patients with and without HIV undergoing atrial fibrillation ablation. A search was performed in the electronic medical record for all patients with HIV who received initial atrial fibrillation ablation from 2011 to 2020. After calculating propensity scores for HIV, matching was performed with patients without HIV by using nearest-neighbor matching without replacement in a 1:2 ratio. The primary outcome was freedom from atrial arrhythmia and secondary outcomes were freedom from atrial fibrillation, freedom from atrial tachycardia, and freedom from repeat ablation, compared by log-rank analysis. The procedures of patients with HIV who underwent repeat ablation at our institution were further analyzed for etiology of recurrence. To further characterize the left atrial substrate, a subsequent case-control analysis was then performed for a set of randomly chosen 10 patients with HIV matched with 10 without HIV to compare minimum and maximum voltage at nine pre-specified regions of the left atrium. RESULTS: Twenty-seven patients with HIV were identified. All were prescribed antiretroviral therapy at time of ablation. These patients were matched with 54 patients without HIV by propensity score. 86.4% of patients with HIV and 76.9% of controls were free of atrial fibrillation or atrial tachycardia at 1 year (p = .509). Log-rank analysis showed no difference in freedom from atrial arrhythmia (p value .971), atrial fibrillation (p-value .346), atrial tachycardia (p value .306), or repeat ablation (p value .401) after initial atrial fibrillation ablation in patients with HIV compared to patients without HIV. In patients with HIV with recurrent atrial fibrillation, the majority had pulmonary vein reconnection (67%). There were no significant differences in minimum or maximum voltage at any of the nine left atrial regions between the matched patients with and without HIV. CONCLUSIONS: Ablation to treat atrial fibrillation in patients with HIV, but without overt AIDS is frequently successful therapy. The majority of patients with recurrence of atrial fibrillation had pulmonary vein reconnection, suggesting infrequent nonpulmonary vein substrate. In this population, the left atrial voltage in patients with HIV is similar to that of patients without HIV. These findings suggest that the pulmonary veins remain a critical component to the initiation and maintenance of atrial fibrillation in patients with HIV.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Infecções por HIV , Veias Pulmonares , Taquicardia Supraventricular , Humanos , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Infecções por HIV/complicações , Infecções por HIV/cirurgia , Resultado do Tratamento , Átrios do Coração , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Recidiva
11.
Heart Rhythm ; 19(5): 759-767, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35038570

RESUMO

BACKGROUND: Hypertrophic cardiomyopathy (HCM) is the most prevalent inherited cardiomyopathy. The implantable cardioverter-defibrillator (ICD) is important for prevention of sudden cardiac death (SCD) in patients at high risk. In recent years, the subcutaneous implantable cardioverter-defibrillator (S-ICD) has emerged as a viable alternative to the transvenous implantable cardioverter-defibrillator (TV-ICD). The S-ICD does not require intravascular access; however, it cannot provide antitachycardia pacing (ATP) therapy. OBJECTIVE: The purpose of this study was to assess the real-world incidence of ICD therapy in patients with HCM implanted with TV-ICD vs S-ICD. METHODS: We compared the incidence of ATP and shock therapies among all HCM patients with S-ICD and TV-ICD enrolled in the Boston Scientific ALTITUDE database. Cumulative Kaplan-Meier incidence was used to compare therapy-free survival, and Cox proportional hazard ratios were calculated. We performed unmatched as well as propensity match analyses. RESULTS: We included 2047 patients with TV-ICD and 626 patients with S-ICD, followed for an average of 1650.5 ± 1038.5 days and 933.4 ± 550.6 days, respectively. Patients with HCM and TV-ICD had a significantly higher rate of device therapy compared to those with S-ICD (32.7 vs 14.5 therapies per 100 patient-years, respectively; P <.001), driven by a high incidence of ATP therapy in the TV-ICD group, which accounted for >67% of therapies delivered. Shock incidence was similar between groups, both in the general and the matched cohorts. CONCLUSION: Patients with HCM and S-ICD had a significantly lower therapy rate than patients with TV-ICD without difference in shock therapy, suggesting potentially unnecessary ATP therapy. Empirical ATP programming in patients with HCM may be unbeneficial.


Assuntos
Cardiomiopatia Hipertrófica , Desfibriladores Implantáveis , Trifosfato de Adenosina , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Humanos , Resultado do Tratamento
12.
J Cardiovasc Electrophysiol ; 33(2): 209-217, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34911157

RESUMO

INTRODUCTION: Prior studies have shown that addition of posterior wall isolation (PWI) may reduce atrial fibrillation recurrence in patients with persistent atrial fibrillation. No data on PWI in paroxysmal AF (pAF) patients with normal left atrial voltage is available, to date. OBJECTIVE: This study sought to evaluate the efficacy of PWI in addition to pulmonary vein isolation (PVI) in patients presenting with pAF and normal left atrial voltage. METHODS: Consecutive patient registry analysis was performed on all patients with pAF and normal left atrial voltage undergoing initial radiofrequency ablation from November 1, 2018 to November 15, 2019. Primary endpoint was recurrence of atrial arrhythmia including AF, atrial tachycardia (AT), or atrial flutter (AFL). RESULTS: A total of 321 patients were studied, 214 in the PVI group and 107 in the PWI + PVI group. Recurrence of any atrial arrhythmia occurred in 18.2% of patients in the PVI group and 16.8% in the PVI + PWI cohort (p = 0.58). At 1 year, recurrence was 14.0% in the PVI group and 15.0% in the PWI + PVI group (p = 0.96). There was a lower AT/AFL recurrence in the PVI + PWI group, not reaching significance (3.7% in the PWI + PVI group vs. 7.9% in PVI group, p = 0.31). Need for carina lesions predicted recurrence in the PVI-only group. CONCLUSIONS: Addition of PWI to PVI in pAF patients undergoing their first ablation did not reduce the frequency of atrial arrhythmia recurrence. This warrants further study in a prospective trial.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
13.
J Interv Card Electrophysiol ; 63(1): 97-101, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33543350

RESUMO

PURPOSE: Catheter ablation procedures for atrial fibrillation (AF) were significantly curtailed during the peak of coronavirus disease 2019 (COVID-19) pandemic to conserve healthcare resources and limit exposure. There is little data regarding peri-procedural outcomes of medical procedures during the COVID-19 pandemic. We enacted protocols to safely reboot AF ablation while limiting healthcare resource utilization. We aimed to evaluate acute and subacute outcomes of protocols instituted for reboot of AF ablation during the COVID-19 pandemic. METHODS: Perioperative healthcare utilization and acute procedural outcomes were analyzed for consecutive patients undergoing AF ablation under COVID-19 protocols (2020 cohort; n=111) and compared to those of patients who underwent AF ablation during the same time period in 2019 (2019 cohort; n=200). Newly implemented practices included preoperative COVID-19 testing, selective transesophageal echocardiography (TEE), utilization of venous closure, and same-day discharge when clinically appropriate. RESULTS: Pre-ablation COVID-19 testing was positive in 1 of 111 patients. There were 0 cases ablation-related COVID-19 transmission and 0 major complications in either cohort. Pre-procedure TEE was performed in significantly fewer 2020 cohort patients compared to the 2019 cohort patients (68.4% vs. 97.5%, p <0.001, respectively) despite greater prevalence of persistent arrhythmia in the 2020 cohort. Same-day discharge was achieved in 68% of patients in the 2020 cohort, compared to 0% of patients in the 2019 cohort. CONCLUSIONS: Our findings demonstrate the feasibility of safe resumption of complex electrophysiology procedures during the COVID-19 pandemic, reducing healthcare utilization and maintaining quality of care. Protocols instituted may be generalizable to other types of procedures and settings.


Assuntos
Fibrilação Atrial , COVID-19 , Ablação por Cateter , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Teste para COVID-19 , Humanos , Pandemias , SARS-CoV-2 , Resultado do Tratamento
14.
Int J Cardiol Heart Vasc ; 37: 100908, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34765721

RESUMO

BACKGROUND: There is limited information on the long-term outcomes of ICDs in patients with inherited arrhythmia syndromes. METHODS: Prospective registry study of inherited arrhythmia patients with an ICD. Incidence of therapies and complications were measured as 5-year cumulative incidence proportions and analyzed with the Kaplan-Meier method. Incidence was compared by device indication, diagnosis type and device type. Cox-regression analysis was used to identify predictors of appropriate shock and device complication. RESULTS: 123 patients with a mean follow up of 6.4 ± 4.8 years were included. The incidence of first appropriate shock was 56.52% vs 24.44%, p < 0.05 for cardiomyopathy and channelopathy patients, despite similar ejection fraction (61% vs 60%, p = 0.6). The incidence of first inappropriate shock was 13.46% vs 56.25%, p < 0.01 for single vs. multi-lead devices. The incidence of first lead complication was higher for multi-lead vs. single lead devices, 43.75% vs. 17.31%, p = 0.04. Patients with an ICD for secondary prevention were more likely to receive an appropriate shock than those with primary prevention indication (HR 2.21, CI 1.07-4.56, p = 0.03). Multi-lead devices were associated with higher risk of inappropriate shock (HR 3.99, CI 1.27-12.52, p = 0.02), with similar appropriate shock risk compared to single lead devices. In 26.5% of patients with dual chamber devices, atrial sensing or pacing was not utilized. CONCLUSION: The rate of appropriate therapies and ICD complications in patients with inherited arrhythmia is high, particularly in cardiomyopathies with multi-lead devices. Risk-benefit ratio should be carefully considered when assessing the indication and type of device in this population.

15.
Heart Rhythm ; 18(12): 2110-2114, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34517119

RESUMO

BACKGROUND: More than 3 million cardiovascular implantable electronic devices (CIEDs) are implanted annually. There are minimal data regarding the timing of diagnosis of acute complications after implantation. It remains unclear whether patients can be safely discharged less than 24 hours postimplantation. OBJECTIVE: The purpose of this study was to determine the precise timing of acute complication diagnosis after CIED implantation and optimal timing for same-day discharge. METHODS: A retrospective cohort analysis of adults 18 years or older who underwent CIED implantation at a large urban quaternary care medical center between June 1, 2015, and March 30, 2020, was performed. Standard of care included overnight observation and chest radiography 6 and 24 hours postprocedure. Medical records were reviewed for the timing of diagnosis of acute complications. Acute complications included pneumothorax, hemothorax, pericardial effusion, lead dislodgment, and implant site hematoma requiring surgical intervention. RESULTS: A total of 2421 patients underwent implantation. Pericardial effusion or cardiac tamponade was diagnosed in 13 patients (0.53%), pneumothorax or hemothorax in 19 patients (0.78%), lead dislodgment in 11 patients (0.45%), and hematomas requiring surgical intervention in 5 patients (0.2%). Of the 48 acute complications, 43 (90%) occurred either within 6 hours or more than 24 hours after the procedure. Only 3 acute complications identified between 6 and 24 hours required intervention during the index hospitalization (0.12% of all cases). CONCLUSION: Most acute complications are diagnosed either within the first 6 hours or more than 24 hours after implantation. With rare exception, patients can be considered for discharge after 6 hours of appropriate monitoring.


Assuntos
Tamponamento Cardíaco , Desfibriladores Implantáveis/efeitos adversos , Intervenção Médica Precoce , Hematoma , Hemotórax , Marca-Passo Artificial/efeitos adversos , Complicações Pós-Operatórias , Implantação de Prótese , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Tamponamento Cardíaco/epidemiologia , Tamponamento Cardíaco/terapia , Unidades de Observação Clínica/estatística & dados numéricos , Diagnóstico Precoce , Intervenção Médica Precoce/métodos , Intervenção Médica Precoce/normas , Intervenção Médica Precoce/estatística & dados numéricos , Feminino , Hematoma/epidemiologia , Hematoma/terapia , Hemotórax/epidemiologia , Hemotórax/terapia , Humanos , Masculino , Complicações Pós-Operatórias/classificação , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Implantação de Prótese/métodos , Radiografia Torácica/métodos , Estudos Retrospectivos , Padrão de Cuidado , Tempo para o Tratamento/organização & administração
16.
Prog Cardiovasc Dis ; 66: 86-91, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34332664

RESUMO

This article reviews and compares the rationale and evidence supporting high-power, short-duration radiofrequency (RF) ablation with those of conventional-power, conventional-duration RF ablation for atrial fibrillation (AF). The pros and cons of each approach, biophysics of ablation, pre-clinical studies informing clinical utilization, and the accumulated clinical evidence are presented. Both conventional-power, conventional-duration RF ablation and high-power, short-duration ablation are similarly safe, and effective approaches for AF ablation. Theoretical advantages of high-power, short-duration ablation, including greater procedure efficiency and limited conductive heating of collateral structures, must be weighed against the narrower safety margin related to rapid energy delivery during high power ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/cirurgia , Potenciais de Ação , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Tomada de Decisão Clínica , Frequência Cardíaca , Humanos , Veias Pulmonares/fisiopatologia , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
Front Cardiovasc Med ; 8: 636073, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33604358

RESUMO

Background: The COVID-19 pandemic has resulted in worldwide morbidity at unprecedented scale. Troponin elevation is a frequent laboratory finding in hospitalized patients with the disease, and may reflect direct vascular injury or non-specific supply-demand imbalance. In this work, we assessed the correlation between different ranges of Troponin elevation, Electrocardiographic (ECG) abnormalities, and mortality. Methods: We retrospectively studied 204 consecutive patients hospitalized at NYU Langone Health with COVID-19. Serial ECG tracings were evaluated in conjunction with laboratory data including Troponin. Mortality was analyzed in respect to the degree of Troponin elevation and the presence of ECG changes including ST elevation, ST depression or T wave inversion. Results: Mortality increased in parallel with increase in Troponin elevation groups and reached 60% when Troponin was >1 ng/ml. In patients with mild Troponin rise (0.05-1.00 ng/ml) the presence of ECG abnormality and particularly T wave inversions resulted in significantly greater mortality. Conclusion: ECG repolarization abnormalities may represent a marker of clinical severity in patients with mild elevation in Troponin values. This finding can be used to enhance risk stratification in patients hospitalized with COVID-19.

18.
J Cardiovasc Electrophysiol ; 31(12): 3117-3123, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33022816

RESUMO

OBJECTIVE: To compare multiple-procedure catheter ablation outcomes of a stepwise approach versus left atrial posterior wall isolation (LA PWI) in patients undergoing nonparoxysmal atrial fibrillation (NPAF) ablation. BACKGROUND: Unfavorable outcomes for stepwise ablation of NPAF in large clinical trials may be attributable to proarrhythmic effects of incomplete ablation lines. It is unknown if a more extensive initial ablation strategy results in improved outcomes following multiple ablation procedures. METHODS: Two hundred twenty two consecutive patients with NPAF underwent first-time ablation using a contact-force sensing ablation catheter utilizing either a stepwise (Group 1, n = 111) or LA PWI (Group 2, n = 111) approach. The duration of follow-up was 36 months. The primary endpoint was freedom from atrial arrhythmia >30 s. Secondary endpoints were freedom from persistent arrhythmia, repeat ablation, and recurrent arrhythmia after repeat ablation. RESULTS: There was similar freedom from atrial arrhythmias after index ablation for both stepwise and LA PWI groups at 36 months (60% vs. 69%, p = .1). The stepwise group was more likely to present with persistent recurrent arrhythmia (29% vs. 14%, p = .005) and more likely to undergo second catheter ablation (32% vs. 12%, p < .001) compared to LA PWI patients. Recurrent arrhythmia after repeat ablation was more likely in the stepwise group compared to the LA PWI group (15% vs. 4%, p = .003). CONCLUSIONS: Compared to a stepwise approach, LA PWI for patients with NPAF resulted in a similar incidence of any atrial arrhythmia, lower incidence of persistent arrhythmia, and fewer repeat ablations. Results for repeat ablation were not improved with a more extensive initial approach.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
19.
Heart Rhythm ; 17(9): 1425-1433, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32407884

RESUMO

Background: There is no known effective therapy for patients with coronavirus disease 2019 (COVID-19). Initial reports suggesting the potential benefit of hydroxychloroquine/azithromycin (HY/AZ) have resulted in massive adoption of this combination worldwide. However, while the true efficacy of this regimen is unknown, initial reports have raised concerns about the potential risk of QT interval prolongation and induction of torsade de pointes (TdP). Objective: The purpose of this study was to assess the change in corrected QT (QTc) interval and arrhythmic events in patients with COVID-19 treated with HY/AZ. Methods: This is a retrospective study of 251 patients from 2 centers who were diagnosed with COVID-19 and treated with HY/AZ. We reviewed electrocardiographic tracings from baseline and until 3 days after the completion of therapy to determine the progression of QTc interval and the incidence of arrhythmia and mortality. Results: The QTc interval prolonged in parallel with increasing drug exposure and incompletely shortened after its completion. Extreme new QTc interval prolongation to >500 ms, a known marker of high risk of TdP, had developed in 23% of patients. One patient developed polymorphic ventricular tachycardia suspected as TdP, requiring emergent cardioversion. Seven patients required premature termination of therapy. The baseline QTc interval of patients exhibiting extreme QTc interval prolongation was normal. Conclusion: The combination of HY/AZ significantly prolongs the QTc interval in patients with COVID-19. This prolongation may be responsible for life-threatening arrhythmia in the form of TdP. This risk mandates careful consideration of HY/AZ therapy in light of its unproven efficacy. Strict QTc interval monitoring should be performed if the regimen is given.


Assuntos
Azitromicina/uso terapêutico , Betacoronavirus , Infecções por Coronavirus/tratamento farmacológico , Hidroxicloroquina/uso terapêutico , Síndrome do QT Longo/epidemiologia , Pneumonia Viral/tratamento farmacológico , Torsades de Pointes/epidemiologia , Idoso , Antibacterianos/uso terapêutico , Antimaláricos/uso terapêutico , COVID-19 , Infecções por Coronavirus/complicações , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Pandemias , Estudos Retrospectivos , SARS-CoV-2 , Tratamento Farmacológico da COVID-19
20.
Heart Rhythm ; 17(5 Pt A): 721-727, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31978595

RESUMO

BACKGROUND: Increased peak luminal esophageal temperature (LET) is associated with increased risk of esophageal injury after left atrial posterior wall (LAPW) ablation. The magnitude, distribution, and risk factors of LET increase with high-power short-duration (HPSD) LAPW ablation are not well understood. OBJECTIVE: The purpose of this study was to describe the spatial and temporal characteristics of LET changes associated with HPSD LAPW radiofrequency (RF) ablation. METHODS: LET was sampled at 20 Hz using a 12-point esophageal temperature monitor (CIRCA S-CATH; Circa Scientific, Inc) in 16 patients undergoing LAPW ablation. Esophageal temperature sensor position and lesion locations were recorded using an electroanatomic mapping system with fluoroscopic integration (CARTO 3, CARTOUNIVU; Biosense Webster, Inc). Point-by-point LAPW ablation was performed at 50 W for 6 seconds. The first 20 LAPW lesions were individually analyzed in each patient. RESULTS: LET increase ≥4°C (8 lesions: max LET 5.8°C), 2°-4°C (34 lesions), and 1°-2°C (58 lesions) occurred at 9 ± 2 mm, 8 ± 2 mm, and 13 ± 2 mm from sensors, respectively. Lesions placed >20 mm from a temperature sensor did not result in an LET increase ≥2°C. Temperature resolution to within 1°C of baseline occurred ∼60 seconds after cessation of RF application. Consecutive lesions resulting in additive heating of at least 1°C occurred in 17 lesion pairs with an interlesion distance of 9 ± 4 mm and interlesion time of 21 ± 4 seconds. CONCLUSION: HPSD LAPW ablation can result in severe esophageal temperature increases. Significant LET increase will be undetected when lesions are >20 mm away from a temperature sensor. Additive LET increase was observed with consecutive lesions placed <20 mm apart within 60 seconds.


Assuntos
Fibrilação Atrial/cirurgia , Temperatura Corporal/fisiologia , Esôfago/fisiopatologia , Monitorização Intraoperatória/métodos , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/métodos , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS