Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 194: 110707, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36787679

RESUMO

Dose-rate monitoring instruments measure the ambient dose equivalent and hence are crucial for protecting workers from radiation exposure. Although plastic scintillation detectors (PSDs) are ideal equipment for dosimetry, they are rarely used owing to the lower detection efficiency than other scintillation detectors. In this study, we acquired ten types of G(E) functions to utilize a PSD in spectroscopic dosimetry using the least-square and first-order methods. The energy response of PSD was much improved in terms of dose evaluation.

2.
Sensors (Basel) ; 21(21)2021 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-34770347

RESUMO

There has been considerable interest in inorganic scintillators based on lutetium due to their favorable physical properties. Despite their advantages, lutetium-based scintillators could face issues because of the natural occurring radioisotope of 176Lu that is contained in natural lutetium. In order to mitigate its potential shortcomings, previous works have studied to understand the energy spectrum of the intrinsic radiation of 176Lu (IRL). However, few studies have focused on the various principal types of photon interactions with matter; in other words, only the full-energy peak according to the photoelectric effect or internal conversion have been considered for understanding the energy spectrum of IRL. Thus, the approach we have used in this study considers other principal types of photon interactions by convoluting each energy spectrum with combinations for generating the spectrum of the intrinsic radiation of 176Lu. From the results, we confirm that the method provides good agreement with the experiment. A significant contribution of this study is the provision of a new approach to process energy spectra induced by mutually independent radiation interactions as a single spectrum.

3.
Opt Express ; 29(24): 39323-39341, 2021 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-34809299

RESUMO

We propose a Bayesian denoising method to improve the quality of ghost imaging. The proposed method achieved the highest PSNR and SSIM in both binary and gray-scale targets with fewer measurements. Experimentally, it obtained a reconstructed image of a USAF target where the PSNR and SSIM of the image were up to 12.80 dB and 0.77, respectively, whereas those of traditional ghost images were 7.24 dB and 0.28 with 3000 measurements. Furthermore, it was robust against additive Gaussian noise. Thus, this method could make the ghost imaging technique more feasible as a practical application.

4.
Sensors (Basel) ; 20(1)2019 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-31877932

RESUMO

Obtaining the in-depth information of radioactive contaminants is crucial for determining the most cost-effective decommissioning strategy. The main limitations of a burial depth analysis lie in the assumptions that foreknowledge of buried radioisotopes present at the site is always available and that only a single radioisotope is present. We present an advanced depth estimation method using Bayesian inference, which does not rely on those assumptions. Thus, we identified low-level radioactive contaminants buried in a substance and then estimated their depths and activities. To evaluate the performance of the proposed method, several spectra were obtained using a 3 × 3 inch hand-held NaI (Tl) detector exposed to Cs-137, Co-60, Na-22, Am-241, Eu-152, and Eu-154 sources (less than 1µCi) that were buried in a sandbox at depths of up to 15 cm. The experimental results showed that this method is capable of correctly detecting not only a single but also multiple radioisotopes that are buried in sand. Furthermore, it can provide a good approximation of the burial depth and activity of the identified sources in terms of the mean and 95% credible interval in a single measurement. Lastly, we demonstrate that the proposed technique is rarely susceptible to short acquisition time and gain-shift effects.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA