Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Diagn Interv Imaging ; 102(1): 35-44, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33012693

RESUMO

PURPOSE: To evaluate the potential of imaging criteria in predicting overall survival of patients with hepatocellular carcinoma (HCC) after a first transcatheter arterial yttrium-90 radioembolization (TARE) MATERIALS AND METHODS: From October 2013 to July 2017, 37 patients with HCC were retrospectively included. There were 34 men and 3 women with a mean age of 60.5±10.2 (SD) years (range: 32.7-78.9 years). Twenty-five patients (68%) were Barcelona Clinic Liver Cancer (BCLC) C and 12 (32%) were BCLC B. Twenty-four primary index tumors (65%) were>5cm. Three radiologists evaluated tumor response on pre- and 4-7 months post-TARE magnetic resonance imaging or computed tomography examinations, using Response Evaluation Criteria in Solid Tumors (RECIST) 1.1, modified RECIST (mRECIST), European Association for Study of the Liver (EASL), volumetric RECIST (vRECIST), quantitative EASL (qEASL) and the Liver Imaging Reporting and Data System treatment response algorithm. Kaplan-Meier survival curves were used to compare responders and non-responders for each criterion. Univariate and multivariate Cox proportional hazard ratio (HR) analysis were used to identify covariates associated with overall survival. Fleiss kappa test was used to assess interobserver agreement. RESULTS: At multivariate analysis, RECIST 1.1 (HR: 0.26; 95% confidence interval [95% CI]: 0.09-0.75; P=0.01), mRECIST (HR: 0.22; 95% CI: 0.08-0.59; P=0.003), EASL (HR: 0.22; 95% CI: 0.07-0.63; P=0.005), and qEASL (HR: 0.30; 95% CI: 0.12-0.80; P=0.02) showed a significant difference in overall survival between responders and nonresponders. RECIST 1.1 had the highest interobserver reproducibility. CONCLUSION: RECIST and mRECIST seem to be the best compromise between reproducibility and ability to predict overall survival in patients with HCC treated with TARE.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Adulto , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/radioterapia , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Radioisótopos de Ítrio/uso terapêutico
2.
Diagn Interv Imaging ; 101(9): 589-598, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32107198

RESUMO

PURPOSE: To retrospectively assess immediate and 1-year success rate of type 2 endoleak (T2E) treatment with ethylene-vinyl-alcohol-polymer using three-dimensional (3D) image fusion guidance with cone beam computed tomography via trans-arterial embolization (TAE) or direct percutaneous sac injection (DPSI). MATERIALS AND METHODS: A total of 37 patients with T2E who were treated either using TAE (34/37; 92%) or DPSI (9/37; 8%) were included. There were 34 men and 3 women with a mean age of 86±9 (SD) years (range: 67-104years). Mean aneurysm diameter was 67±14 (SD) mm (range: 42-101mm) at pre-procedure evaluation. Immediate success was complete embolization of the sac and feeding artery. 1-year success was reduction or stability of the aneurysmal sac diameter based on pre-procedure and 12-month follow-up examinations. Safety (treatment-related complications), patient demographics, duration of procedure and contrast volume were reported. RESULTS: Immediate and 1-year successful outcomes were reported in 94% (n=32) and 88% (n=28) of patients after TAE and 100% (n=9) and 89% (n=8) after DPSI. T2E treatments were immediately successful for 95% of the procedures (41/43) and for 88% (36/41) at 1year. Overall, T2E treatment was effective in 33 patients (89%). No major complications occurred. Mean procedure time and contrast volume were significantly different between the 2 techniques with respectively 87±16 (SD) min (range: 65-120min) and 75±26 (SD) mL (range: 40-130mL) for TAE and 32±10 (SD) min (range: 20-50min) (P<0.01) and 6±6 (SD) mL (range: 2-22mL) (P<0.01) for DPSI. Mean aneurysm diameter at 1-year was 68±17 (SD) mm (range: 43-101mm). No significant differences in the pre-procedure sac diameter were found at long-term follow-up between patients without T2E and those with persistent T2E (P=0.1) in the successful embolization group (n=33). CONCLUSION: TAE or DPSI treatments of T2E with ethylene-vinyl-alcohol-polymer using 3D-image fusion guidance were immediately successful for 95% of the procedures and remained effective for 88%. Longer follow-up is necessary to assess sac stability in the case of persistent endoleak.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Embolização Terapêutica , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Endoleak/diagnóstico por imagem , Endoleak/terapia , Feminino , Humanos , Imageamento Tridimensional , Masculino , Estudos Retrospectivos , Resultado do Tratamento
3.
Diagn Interv Imaging ; 99(9): 527-535, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29609903

RESUMO

PURPOSE: To report current practices of transarterial chemoembolization (TACE) by interventional radiologists (IR) for hepatocellular carcinoma (HCC) through a French national survey. MATERIALS AND METHODS: An electronic survey was sent by e-mail to 232 IRs performing TACE in 32 private or public centers. The survey included 66 items including indications for TACE, technical aspects of TACE, other locally available treatments for HCC, follow-up imaging and general aspects of interventional radiology practices. RESULTS: A total of 64 IRs (64/232; 27%) answered the survey. Each IR performed a mean of 49±45 (SD) TACE procedures per year. Marked variations in indications for TACE in HCC were observed. Six percent of IRs (4/64) treated only patients with Barcelona Clinic Liver Cancer (BCLC) stage B HCC. Antibioprophylaxis was not used by 43/64 of IRs (67%). The number of HCC nodules was considered to select conventional TACE versus drug-eluting beadsTACE (DEB-TACE) by 17/49 IRs (35%) followed by patient performance status and Child-Pugh score by 6/49 IRs (12%). Seventy-three percent of IRs (45/62) treated nodules selectively in patients with unilobar disease with cTACE. Thirty-three percent of IRs (21/64) planned systematically a second TACE session. Doxorubicin was the most frequently used drug (52/64; 81%) and 15/64 IRs (23%) used gelatine sponge as the only embolic agent. For DEB-TACE, 100-300µm beads were used by 26/49 IRs (53%) and no additional embolization was performed by 19/48 IRs (39%). Monopolar radiofrequency technique was widely available (59/63; 94%) compared to selective internal radiation therapy (37/64; 58%). Magnetic resonance imaging was used for follow-up by 13/63 IRs (20%). CONCLUSION: Current practices of TACE for HCC varied widely among IRs suggesting a need for more standardized practices.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Quimioembolização Terapêutica/estatística & dados numéricos , Neoplasias Hepáticas/terapia , Padrões de Prática Médica/estatística & dados numéricos , Antibioticoprofilaxia/estatística & dados numéricos , Antibióticos Antineoplásicos/administração & dosagem , Carcinoma Hepatocelular/diagnóstico por imagem , Tomada de Decisão Clínica , Doxorrubicina/administração & dosagem , França , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/estatística & dados numéricos , Recidiva Local de Neoplasia/terapia , Inquéritos e Questionários
5.
Diagn Interv Imaging ; 98(2): 125-132, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27692958

RESUMO

PURPOSE: To detect if a difference of T2 ratio, defined as the signal intensity (SI) of the myocardium divided by the SI of the skeletal muscle on T2-weigthed cardiac magnetic resonance (CMR) imaging, exists between patients with systemic amyloidosis, by comparison to control subjects. To determine if a relationship exists between T2 ratio and the overall mortality. MATERIALS AND METHODS: CMR imaging examinations of 73 consecutive patients (48 men, 25 women; mean age, 63 years±15[SD]) with amyloidosis and suspicion of CA and 27 control subjects were retrospectively analyzed after institutional review board approval. Final diagnosis of CA was retained in case of histological confirmation of CA, typical pattern of CA on imaging and/or positivity of 99Technetium-hydroxymethylene diphosphonate scintigraphy. Patients were divided in 2 groups according to the presence or the absence of CA. T2 ratios were calculated in patients with and those without CA and in control subjects with using analysis of variance. Prognostic value of T2 ratio was studied with a Kaplan-Meier curve. RESULTS: Thirty-five patients (51%) had CA and 33 (49%) were free from CA. T2 ratio was lower in patients with CA (1.18±0.29) than in patients without cardiac involvement (1.37±0.35) (P=0.03) and control subjects (1.45±0.24) (P=0.004). A T2 ratio of 1.36 was the best threshold value for predicting CA with a sensitivity of 63% and a specificity of 73%. Kaplan-Meier analysis showed a significant relationship between a shortened overall survival and a T2 ratio<1.36. CONCLUSION: Patients with CA exhibit lower T2 ratio on CMR imaging by comparison with patients free of CA and control subjects.


Assuntos
Amiloidose/diagnóstico por imagem , Cardiopatias/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Meios de Contraste , Feminino , Humanos , Imageamento Tridimensional , Masculino , Meglumina , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio , Compostos Organometálicos , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Sensibilidade e Especificidade , Medronato de Tecnécio Tc 99m/análogos & derivados
7.
Eur J Vasc Endovasc Surg ; 50(5): 583-92, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26259766

RESUMO

OBJECTIVES: The aim was to determine whether physician modified stent grafts (PMSGs) are safe and effective for the treatment of high risk patients with thoraco-abdominal aortic aneurysms (TAAAs). DESIGN: This was a retrospective single institution study. MATERIAL: Consecutive patients with TAAA undergoing endovascular repair using a PMSG between January 2012 and June 2014 were evaluated. METHODS: Fenestrations to preserve branch vessels were created in TX2 thoracic (Cook Medical) stent grafts. Pre- intra- and post-operative data were recorded by means of a prospectively maintained database. RESULTS: Eleven high risk patients with TAAA (type I, n = 4; type III, n = 3; type IV, n = 3; type V, n = 1) underwent fenestrated endovascular repair using PMSGs. Indications were painful aneurysm (n = 5), >70 mm rapidly enlarging aneurysm (n = 4), saccular aneurysm (n = 1), and visceral patch false aneurysm after open repair of a type IV TAAA (n = 1). In four asymptomatic patients, an additional fenestration was created for temporary selective sac perfusion and occluded 2-4 weeks later. Median duration for stent graft modifications was 2 hours (range 1-3 hours). The median number of fenestrations was three (range 2-4). One patient died during the post-operative period from colonic ischemia, giving a 9% in hospital mortality rate. Four (36%) patients presented with moderate to severe complications. One (9%) patient presented with a paraparesis that resolved completely after spinal fluid drainage. Among surviving patients, four required early endovascular re-intervention for type III endoleak (n = 2), type Ia endoleak (n = 1), or target vessel cannulation failure (n = 1). The median follow up time was 6 months (range 3-20 months). During follow up, no other complications occurred and all target vessels remained patent. One patient presented with a persistent type II endoleak. CONCLUSION: PMSGs provided acceptable short-term results and may be a management option for the treatment of TAAA in selected high risk patients. Durability concerns need to be assessed in additional studies with long-term follow up.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Stents , Idoso , Idoso de 80 Anos ou mais , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
8.
Diagn Interv Imaging ; 96(7-8): 833-40, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26138359

RESUMO

Following interventional radiology procedures, bleeding can occur in 0.5 to 4% of the cases. Risk factors are related to the patient, to the procedure, and to the end organ. Bleeding is treated usually by interventional radiologists and consists mainly of embolization. Bleeding complications are preventable: before the procedure by checking hemostasis, during the procedure by ensuring the accurate puncture site (with ultrasound or fluoroscopy guidance) or by treating the puncture path using gelatin sponge, curaspon(®), biological glue or thermocoagulation, and after the procedure by carefully monitoring the patients.


Assuntos
Hemorragia/etiologia , Idoso , Falso Aneurisma/etiologia , Falso Aneurisma/prevenção & controle , Falso Aneurisma/terapia , Biópsia/efeitos adversos , Ablação por Cateter , Cateterismo/efeitos adversos , Cateterismo/métodos , Quimioembolização Terapêutica , Embolização Terapêutica/métodos , Feminino , Artéria Femoral , Hemorragia/prevenção & controle , Hemorragia/terapia , Humanos , Masculino , Punções , Radiologia Intervencionista/métodos , Fatores de Risco , Tomografia Computadorizada por Raios X
9.
Diagn Interv Imaging ; 96(7-8): 797-806, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26054246

RESUMO

Visceral artery aneurysms are rare but their estimated mortality due to rupture ranges between 25 and 70%. Treatment of visceral artery aneurysm rupture is usually managed by interventional radiology. Specific embolization techniques depend on the location, affected organ, locoregional arterial anatomy, and interventional radiologist skill. The success rate following treatment by interventional radiology is greater than 90%. The main complication is recanalization of the aneurysm, showing the importance of post-therapeutic monitoring, which should preferably be performed using MR imaging.


Assuntos
Aneurisma Roto/diagnóstico , Aneurisma Roto/terapia , Embolização Terapêutica , Serviços Médicos de Emergência , Vísceras/irrigação sanguínea , Aneurisma Roto/mortalidade , Angiografia , Comportamento Cooperativo , Humanos , Comunicação Interdisciplinar , Imageamento por Ressonância Magnética , Tomografia Computadorizada Multidetectores , Prognóstico , Análise de Sobrevida
10.
Eur J Vasc Endovasc Surg ; 50(3): 303-10, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26001320

RESUMO

OBJECTIVES/BACKGROUND: ECAR (Endovasculaire ou Chirurgie dans les Anévrysmes aorto-iliaques Rompus) is a prospective multicentre randomized controlled trial including consecutive patients with ruptured aorto-iliac aneurysms (rAIA) eligible for treatment by either endovascular (EVAR) or open surgical repair (OSR). Inclusion criteria were hemodynamic stability and computed tomography scan demonstrating aorto-iliac rupture. METHODS: Randomization was done by week, synchronously in all centers. The primary end point was 30 day mortality. Secondary end points were post-operative morbidity, length of stay in the intensive care unit (ICU), amount of blood transfused (units) and 6 month mortality. RESULTS: From January 2008 to January 2013, 107 patients (97 men, 10 women; median age 74.4 years) were enrolled in 14 centers: 56 (52.3%) in the EVAR group and 51 (47.7%) in the OSR group. The groups were similar in terms of age, sex, consciousness, systolic blood pressure, Hardman index, IGSII score, type of rupture, use of endoclamping balloon, and levels of troponin, creatinine, and hemoglobin. Delay to treatment was higher in the EVAR group (2.9 vs. 1.3 hours; p < .005). Mortality at 30 days and 1 year were not different between the groups (18% in the EVAR group vs. 24% in the OSR group at 30 days, and 30% vs. 35%, respectively, at 1 year). Total respiratory support time was lower in the EVAR group than in the OSR group (59.3 hours vs. 180.3 hours; p = .007), as were pulmonary complications (15.4% vs. 41.5%, respectively; p = .050), total blood transfusion (6.8 vs. 10.9, respectively; p = .020), and duration of ICU stay (7 days vs. 11.9 days, respectively; p = .010). CONCLUSION: In this study, EVAR was found to be equal to OSR in terms of 30 day and 1 year mortality. However, EVAR was associated with less severe complications and less consumption of hospital resources than OSR.


Assuntos
Aneurisma Roto/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco/cirurgia , Idoso , Idoso de 80 Anos ou mais , Aneurisma Roto/diagnóstico , Aneurisma Roto/economia , Aneurisma Roto/mortalidade , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/economia , Aneurisma da Aorta Abdominal/mortalidade , Ruptura Aórtica/diagnóstico , Ruptura Aórtica/economia , Ruptura Aórtica/mortalidade , Transfusão de Sangue , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/economia , Implante de Prótese Vascular/mortalidade , Análise Custo-Benefício , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/economia , Procedimentos Endovasculares/mortalidade , Feminino , França , Custos Hospitalares , Mortalidade Hospitalar , Humanos , Aneurisma Ilíaco/diagnóstico , Aneurisma Ilíaco/economia , Aneurisma Ilíaco/mortalidade , Estimativa de Kaplan-Meier , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
11.
Eur J Vasc Endovasc Surg ; 27(3): e21-e23, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24920877

RESUMO

INTRODUCTION: Chronic mesenteric ischemia (CMI) is a challenging problem, with revascularization the mainstay of treatment. Management of CMI is especially challenging in the patient with superior mesenteric artery (SMA) and celiac artery (CA) occlusions. REPORT: We report a case series of four patients with chronic mesenteric ischemia who were not candidates for CA or SMA revascularization who were successfully treated with inferior mesenteric artery (IMA) angioplasty and stent placement to improve collateral circulation and palliate symptoms. DISCUSSION: To our knowledge, this is the largest case series to date reporting the use of an IMA stent to improve collateral circulation in patients with CMI.

12.
Diagn Interv Imaging ; 95(5): 505-12, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24794793

RESUMO

The management of colorectal intrahepatic metastases before resection is multidisciplinary and radiologists and nuclear medicine specialists play a major role. In accordance with the French National Guide for appropriate use of diagnostic imaging, the approach should be multimodal: a chest-abdomen and pelvic (CAP) CT scan and hepatic MRI are mandatory while PET-CT provides important additional information, in particular on intra-abdominal extrahepatic metastases. This multimodal approach emphasizes the importance of early and appropriate use of imaging in these patients, as well as the central role of multidisciplinary meetings in oncology.


Assuntos
Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/terapia , Diagnóstico por Imagem/métodos , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/terapia , Neoplasias Colorretais/patologia , Terapia Combinada , Comportamento Cooperativo , Progressão da Doença , Humanos , Comunicação Interdisciplinar , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Prognóstico , Tomografia Computadorizada por Raios X/métodos
13.
Eur J Vasc Endovasc Surg ; 47(1): 45-52, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24268517

RESUMO

BACKGROUND: Several studies have examined inter-observer variability in measurements for standard EVAR, but little is known about measurements for complex aortic aneurysm. METHODS: Two independent observers reviewed all preoperative CT scans of 268 patients in a French trial of fenestrated and/or branched aortic stent-grafts (f/b-EVAR). Those data were compared with those obtained (1) by investigators (extent of aneurysm, target vessel stenosis, and aortic diameters), and (2) from manufacturers (proximal landing zone, device diameter, and target vessel position). We assessed the reproducibility using kappa statistics for qualitative data and both Bland-Altman plot and Passing-Bablok regression analysis for quantitative data. RESULTS: Reproducibility was moderate to almost perfect for all factors. However, a few critical discrepancies were found, such as target vessel clock position (≥45 minutes) and location (≥5 mm), level of proximal landing zone, and diameters of the endograft. CONCLUSIONS: This is the first large-scale analysis focused on inter-observer variability in sizing for f/b-EVAR. The measurement data showed good agreement, but there were some critical discrepancies between observers that may affect clinical results.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aortografia/métodos , França , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
14.
J Radiol ; 92(7-8): 688-700, 2011.
Artigo em Francês | MEDLINE | ID: mdl-21819911

RESUMO

PURPOSE: To validate the 2010 diagnostic criteria from the American Association for the Study of Liver Diseases (AASLD) for hepatocellular carcinoma (HCC) on MRI using the surgical liver specimen as a gold standard. PATIENTS AND METHODS: A total of 21 liver transplant recipients were retrospectively included. Each underwent surgery because of HCC between January 2007 and January 2008. Pre-transplant MRI was performed on a 1.5 Tesla MR unit. The T1W and T2W signal and kinetic contrast enhancement were correlated for each lesion with the surgical specimen. Lesion diameters between MRI and specimen were compared (Spearman). A multivariate model was created (R statistics software package) to predict the presence and grade of tumor differentiation (WHO, Edmonson Steiner). RESULTS: A total of 71 nodules were detected at histology, including 54 HCC (mean size: 25.3mm) compared to 68 on MRI. There was moderate agreement (r=0.58, P<0.001) between the maximum lesion diameters measured on MRI and at histology. Wash-out on MRI provided an accuracy of 75 % for the detection of HCC (sensitivity=75 %, specificity=76 %). Adding T2W hyperintensity to the AASLD criteria increased the sensitivity of MRI from 70.3 % to 77.7 % for the diagnosis of HCC and from 67.6 % to 79 % for nodules less than 20mm in diameter, without affecting specificity. On multivariate analysis, wash out as a single variable was significantly associated with a diagnosis of HCC (P<0.01, odds ratio 12.0, CI 95 % [2.6-55.5]). T1W hyperintensity (P=0.04, odds ratio 5.4) and loss of signal on opposed-phase images (P=0.02, odds ratio 9.2) were predictive of good differentiation. CONCLUSION: On MRI, the AASLD criteria or presence of wash out within a liver nodule in patients with underlying chronic hepatocellular disease are suggestive of tumoral transformation. The addition of T2W hyperintensity to the AASLD criteria increases the detection of HCC, especially nodules smaller than 20mm.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/patologia , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/patologia , Transplante de Fígado , Imageamento por Ressonância Magnética , Idoso , Algoritmos , Carcinoma Hepatocelular/cirurgia , Transformação Celular Neoplásica/patologia , Meios de Contraste/administração & dosagem , Feminino , França , Humanos , Neoplasias Hepáticas/cirurgia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Retrospectivos , Sensibilidade e Especificidade , Sociedades Médicas , Estatística como Assunto , Carga Tumoral
15.
Eur J Vasc Endovasc Surg ; 42(3): 340-6, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21628100

RESUMO

INTRODUCTION: Splanchnic and renal artery aneurysms (SRAAs) are uncommon but potentially life-threatening in case of rupture. Whether these aneurysms are best treated by open repair or endovascular intervention is unknown. The aim of this retrospective study is to report the results of open and endovascular repairs in two European institutions over a fifteen-year period. We have reviewed the available literature published over the 10 last years. METHODS: All patients with SRAAs diagnosed from 1995 to 2010 in St Marys Hospital (London, UK) and Henri Mondor Hospital (Créteil, France) were reviewed. Preoperative clinical and anatomical data, operative management and outcomes were recorded from the charts and analyzed. RESULTS: 40 patients with 51 SRAAs were identified. There were 21 males and 19 females with a mean age of 57 ± 14.9 years. The aneurysms locations were: 14 (27%) renal, 11 (22%) splenic, 7 (14%) celiac trunk, 7 (14%) superior mesenteric artery, 4 (8%) hepatic, 4 (8%) pancreaticoduodenal arcades, 3 (6%) left gastric and 1 (2%) gastroduodenal. 4 patients presented with a ruptured SRAA. 17 SRAAs in 16 patients were treated by open repair, 15 in 15 patients were treated endoluminally and 17 (mean diameter: 18 mm, range: 8-75 mm) were managed conservatively. One patient with metastatic pulmonary cancer with two mycotic aneurysms of the superior mesenteric artery (75 mm) and celiac trunk (15 mm) was palliated. After endovascular treatment, the immediate technical success rate was 100%. There was no significant difference between open repair and endovascular patients in terms of 30-day post-operative mortality rate and peri-operative complications. No in-hospital death occurred in patients treated electively. Postoperatively, four patients (1 ruptured and 3 elective) suffered non-lethal mild to severe complication in the open repair group, as compared with one in the endovascular group (p = .34). The mean length of stay was significantly higher after open repair as compared with endovascular repair (17 days, range: 8-56 days vs. 4 days, range: 2-6; p < .001). The mean follow-up time was 17.8 months (range: 0-143 months) after open repair, 15.8 months (range: 0-121 months) after endovascular treatment, and 24.8 (range: 3-64 months) for patient being managed conservatively. No late death related to the VAA occurred. In each group, 2 successful reoperations were deemed necessary. In the endovascular group, two patients presented a reperfusion of the aneurysmal sac at 6 and 24 months respectively. CONCLUSION: No significant difference in term of 30-day mortality and post-operative complication rates could be identified between open repair and endovascular treatment in the present series. Endovascular treatment is a safe alternative to open repair but patients are exposed to the risk of aneurysmal reperfusion. This mandates careful long-term imaging follow up in patients treated endoluminally.


Assuntos
Aneurisma/cirurgia , Artéria Renal , Circulação Esplâncnica , Adulto , Idoso , Implante de Prótese Vascular , Procedimentos Endovasculares , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Reino Unido
16.
Eur J Vasc Endovasc Surg ; 40(3): 340-7, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20619704

RESUMO

PURPOSE: Anatomy of the aortic arch is highly variable and can be drastically altered by surgical or endovascular procedures. Detailed analysis of computed tomography (CT) scans is facilitated by reconstruction techniques such as virtual angioscopy (VA). In the present study, we have evaluated the benefit of VA for the assessment of aortic arch abnormalities in patients with prior surgical or endovascular procedures. MATERIAL AND METHODS: We analysed post-procedural CT scans available in 103 patients who underwent thoracic aortic procedures between 2006 and 2009 at our institution. Patients were classified into three groups: surgical (group A, n = 26), hybrid (group B, n = 27) and endovascular (group C, n = 50), procedures. A 64 LightSpeed volume computed tomography (VCT) multidetector-row computed tomography was used, allowing maximal intensity projection, maximal projection rendering imaging and three-dimensional (3D) rendering of images. VA reconstruction was performed by applying volume-rendered thresholds and spatial rendering to generate endoluminal views. RESULTS: Multiplanar reformations (MPRs) detected 46 abnormalities in 39 patients: inadequate apposition of the proximal rim of a stent-graft (n = 21), abnormalities of the stent-graft itself (n = 11), aortic aneurysm (n = 6), residual intimal tears (n = 5) and secondary dissection (n = 3). VA provided additional information in 76% of cases (35/46) and was more contributive after endovascular repair than after open repair (group A: 54% (7/14), group B: 75% (9/12), group C: 95% (19/20)). VA improved localisation of abnormalities with respect to supra-aortic vessels, measured inadequate stent-graft apposition in relation to the aortic wall and precisely analysed kinking or inadequate apposition of overlapping stent grafts. VA diagnosed three additional abnormalities: two false aneurysms and one retrograde dissection developed on a suture line. CONCLUSIONS: VA conceptualises planar images by 3D reconstruction. It provides additional information in comparison with conventional CT scans by allowing precise localisation of abnormalities with respect to the aortic wall itself and supra-aortic vessels. Furthermore, it facilitates analysis of abnormalities in case of overlapping stent grafts.


Assuntos
Angioscopia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/cirurgia , Implante de Prótese Vascular , Imageamento Tridimensional , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reoperação , Estudos Retrospectivos , Stents , Resultado do Tratamento
17.
J Radiol ; 91(1 Pt 1): 47-51, 2010 Jan.
Artigo em Francês | MEDLINE | ID: mdl-20212376

RESUMO

PURPOSE: Conventional balloon angioplasty of anastomotic stenosis following bypass surgery is insufficient at mid- and long-term. However, short-term results with cutting balloon angioplasty (CBA) are satisfactory. The purpose of this study is to determine the long-term results using this technique. Materials and methods. Between January 2002 and January 2006, all patients with anastomotic stenosis more than one month after bypass surgery, shorter than 2 cm and>50%, were referred without randomisation to CBA. RESULTS: A total of 19 patients with mean age of 63.5 years (55-82 years), 14 males and 5 females, were included. Twenty stenoses (femoral n=15, popliteal n=4 and calf n=1) managed with CBA affected 17 infrainguinal and 2 suprainguinal bypasses. One patient had anastomotic stenoses at both extremities. The rate of technical success aws 100%. Mean follow-up was 32 months (12-42). Three deaths occurred during follow-up. One patient presented with restenosis at 3 months, successfully treated with repeat CBA. No thrombosis or infection was observed. CONCLUSION: The results with CBA appear persistent and compete favorably with results from surgical repair. A randomized trial would be necessary to confirm these results.


Assuntos
Anastomose Cirúrgica/métodos , Angioplastia com Balão/métodos , Derivação Arteriovenosa Cirúrgica/métodos , Oclusão de Enxerto Vascular/cirurgia , Isquemia/cirurgia , Perna (Membro)/irrigação sanguínea , Complicações Pós-Operatórias/cirurgia , Idoso , Idoso de 80 Anos ou mais , Angiografia , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Humanos , Isquemia/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem
19.
Eur Radiol ; 18(10): 2303-10, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18463875

RESUMO

The goal of this study was to assess the changes of water diffusion during contraction and elongation of calf muscles using diffusion tensor (DT) MRI in normal volunteers. Twenty volunteers (mean age, 29+/-4 years) underwent DT MRI examination of the right calf. Echo planar imaging sequence was performed at rest, during dorsal flexion and during plantar flexion. The three eigenvalues (lambda1, lambda2, and lambda3), apparent diffusion coefficient (ADC) and fractional anisotropy (FA) of the diffusion tensor were calculated for medial gastrocnemius (mGM) and tibialis anterior (TA). A fiber tractography was performed on both muscles. Non-parametric Wilcoxon and Mann Whitney tests were used for statistical evaluation. At rest, lambda1, lambda2 and ADC of mGM were higher than their counterparts of TA (P<0.01). During dorsal flexion, the three eigenvalues and ADC of TA significantly increased (P<0.05) as their counterparts of mGM slightly decreased (P=NS). Opposite variations were detected during plantar flexion of the foot. Visual analysis evidenced a relationship between 3D representations of MRI fibers and physiological state of muscles. Contraction of calf muscles produces changes in DT parameters, which are related to the physiological state of the muscle.


Assuntos
Água Corporal/fisiologia , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Perna (Membro)/fisiologia , Contração Muscular/fisiologia , Músculo Esquelético/anatomia & histologia , Músculo Esquelético/fisiologia , Adulto , Feminino , Humanos , Perna (Membro)/anatomia & histologia , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego
20.
J Cardiovasc Surg (Torino) ; 49(2): 199-206, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18431340

RESUMO

AIM: Aneurysm shrinkage is an expected outcome after stent-grafting for abdominal aortic aneurysm (AAA). A worrying problem following repair is progressive enlargement indicating persistent sac pressurization: in this setting not all grafts are equal. The Cook Zenith device (CZ) became available on the European market in 1999. While multicenter studies on the device have shown favorable clinical results at mid-term follow-up, few have focused on sac behavior. This study evaluated AAA sac behavior and predictive factors of its evolution by assessing the five-year results obtained with the CZ graft in a single-institution experience. METHODS: All consecutive elective surgery patients treated with a CZ graft for infrarenal aortic or aortoiliac aneurysm repair from January 2000 to November 2004 in our institution were included prospectively in the study and followed at 1, 6, 12, 18, 24 months and yearly thereafter. Pre-, intra- and postoperative data were recorded in a computerized database. Computed tomography (CT) scans were reviewed by a senior radiologist to identify any abnormalities including endoleak and graft malfunction. Pre- and postoperative maximum sac diameters were derived from measurements of CT findings and then compared. A change of at least 8 mm in sac size was considered significant. Overall results are expressed according to the Committee on Reporting Standards of AAA treatment. Factors that may have influenced sac behavior were analyzed by dividing the patients into 3 groups according to whether the sac diameter remained unchanged (group 1), had increased (group 2) or regressed (group 3). Statistical analysis of the demographic and CT-scan data was then performed. RESULTS: The study sample was 212 consecutive patients (mean age 72.8+/-9.0 years); the mean aneurysm diameter before treatment was 55.5+/-9.8 mm. All stent grafts were successfully implanted. The 30-day mortality rate was 0.94% (2/212); the morbidity rate was 11.7% (25/212). The primary technical success rate was 93.40%; the assisted primary technical success and secondary technical success rates were 96.63% and 99.52%, respectively. The mean follow-up period was 17.7+/-14.7 (1-60) months. The cumulative survival probability was 94%, 84.2%, and 72.9% at 12, 24, and 36 months, respectively. The endoleak-free survival probabilities at 12 and 24 months were 75.7% and 62.8%, respectively. The free of intervention survival rates were 82.1%, 68.9% and 60.6% at 12, 24 and 38 months, respectively. At five years follow-up, the overall clinical success rate was 49.5%. If changes in sac diameter occurred, they were noted at 13 months on average. Sac size remained unchanged in 115 (54.3%) patients (group 1), increased in 9 (4.2%) (group 2), and regressed in 88 (41.5%) (group 3). Neither preoperative patient demographics nor aneurysm characteristics were found to be predictive of sac behavior. Aortouniliac graft configuration was predictive of sac shrinkage (P=0.020). Endoleak was more frequent among patients in groups 1 (27/115; 23%) and 2 (5/9; 56%) than among those in group 3 (9/88;10%) (P=0.001). Reduction in aneurysm sac diameter was less marked in patients with any type of endoleak (P=0.0003). CONCLUSION: The CZ grafts offered satisfactory overall results up to five years of follow-up; nevertheless, sac diameter increased in 4.25% of patients. Endoleak was a predictive factor of a lack of sac shrinkage, while aortouniliac graft configuration was predictive of sac shrinkage.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Prótese Vascular , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/patologia , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Stents , Análise de Sobrevida , Taxa de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA