Magn Reson Med ; 92(1): 346-360, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38394163

RESUMO

PURPOSE: To introduce alternating current-controlled, conductive ink-printed marker that could be implemented with both custom and commercial interventional devices for device tracking under MRI using gradient echo, balanced SSFP, and turbo spin-echo sequences. METHODS: Tracking markers were designed as solenoid coils and printed on heat shrink tubes using conductive ink. These markers were then placed on three MR-compatible test samples that are typically challenging to visualize during MRI scans. MRI visibility of markers was tested by applying alternating and direct current to the markers, and the effects of applied current parameters (amplitude, frequency) on marker artifacts were tested for three sequences (gradient echo, turbo spin echo, and balanced SSFP) in a gel phantom, using 0.55T and 1.5T MRI scanners. Furthermore, an MR-compatible current supply circuit was designed, and the performance of the current-controlled markers was tested in one postmortem animal experiment using the current supply circuit. RESULTS: Direction and parameters of the applied current were determined to provide the highest conspicuity for all three sequences. Marker artifact size was controlled by adjusting the current amplitude, successfully. Visibility of a custom-designed, 20-gauge nitinol needle was increased in both in vitro and postmortem animal experiments using the current supply circuit. CONCLUSION: Current-controlled conductive ink-printed markers can be placed on custom or commercial MR-compatible interventional tools and can provide an easy and effective solution to device tracking under MRI for three sequences by adjusting the applied current parameters with respect to pulse sequence parameters using the current supply circuit.


Assuntos
Desenho de Equipamento , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Animais , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Artefatos , Imagem por Ressonância Magnética Intervencionista/instrumentação
2.
Biomed Eng Online ; 22(1): 113, 2023 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-38044423

RESUMO

BACKGROUND: Understanding the hemodynamics of an abdominal aortic aneurysm (AAA) is crucial for risk assessment and treatment planning. This study introduces a low-cost, patient-specific in vitro AAA model to investigate hemodynamics using particle image velocimetry (PIV) and flow-simulating circuit, validated through fluid-structure interaction (FSI) simulations. METHODS: In this study, 3D printing was employed to manufacture a flexible patient-specific AAA phantom using a lost-core casting technique. A pulsatile flow circuit was constructed using off-the-shelf components. A particle image velocimetry (PIV) setup was built using an affordable laser source and global shutter camera, and finally, the flow field inside the AAA was analyzed using open-source software. Fluid-structure interaction (FSI) simulations were performed to enhance our understanding of the flow field, and the results were validated by PIV analysis. Both steady-state and transient flow conditions were investigated. RESULTS: Our experimental setup replicated physiological conditions, analyzing arterial wall deformations and flow characteristics within the aneurysm. Under constant flow, peak wall deformations and flow velocities showed deviations within - 12% to + 27% and - 7% to + 5%, respectively, compared to FSI simulations. Pulsatile flow conditions further demonstrated a strong correlation (Pearson coefficient 0.85) in flow velocities and vectors throughout the cardiac cycle. Transient phenomena, particularly the formation and progression of vortex structures during systole, were consistently depicted between experimental and numerical models. CONCLUSIONS: By bridging high-fidelity experimental observations with comprehensive computational analyses, this study underscores the potential of integrated methodologies in enhancing our understanding of AAA pathophysiology. The convergence of realistic AAA phantoms, precise PIV measurements at affordable cost point, and validated FSI models heralds a new paradigm in vascular research, with significant implications for personalized medicine and bioengineering innovations.


Assuntos
Aneurisma da Aorta Abdominal , Hemodinâmica , Humanos , Velocidade do Fluxo Sanguíneo , Artérias/fisiologia , Reologia , Modelos Cardiovasculares
3.
Med Eng Phys ; 115: 103981, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37120176

RESUMO

Critical limb ischemia (CLI) is the most severe form of peripheral arterial disease (PAD) which induces extremity rest pain, extremity gangrene or ulcers that mostly might lead to limb loss. One of the most common criteria of CLI is 50 mmHg or less systolic ankle arterial pressure. In this study, a custom made three-lumen catheter (9 Fr) including a distal inflatable balloon in between the inflow and outflow lumen holes was designed and fabricated based on the patented design of Hyper Perfusion Catheter. The proposed catheter design aims to increase ankle systolic pressure to 60 mmHg or more to promote healing and/or alleviating severe pain due to intractable ischemia for patients with CLI. To simulate the blood circulation of related anatomy, in vitro CLI model phantom was designed and constructed by using a modified hemodialysis circuit, a hemodialysis pump and a tube set for cardio-pulmonary bypass surgery. A blood mimicking fluid (BMF) with dynamic viscosity of 4.1 mPa.s was used at 22 ºC to prime the phantom. The data was collected by a custom-made circuit design in real time and all measurements were verified with commercial certificated medical devices. The results of in vitro CLI model phantom experiments have shown that it is feasible to elevate the pressure distal to the occlusion (representing ankle pressure) above 80 mmHg without affecting the systemic pressure.


Assuntos
Extremidade Inferior , Doença Arterial Periférica , Humanos , Isquemia/terapia , Doença Arterial Periférica/complicações , Doença Arterial Periférica/terapia , Dor , Catéteres , Resultado do Tratamento
4.
Magn Reson Med ; 89(2): 845-858, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36198118

RESUMO

PURPOSE: We describe a clinical grade, "active", monopole antenna-based metallic guidewire that has a continuous shaft-to-tip image profile, a pre-shaped tip-curve, standard 0.89 mm (0.035″) outer diameter, and a detachable connector for catheter exchange during cardiovascular catheterization at 0.55T. METHODS: Electromagnetic simulations were performed to characterize the magnetic field around the antenna whip for continuous tip visibility. The active guidewire was manufactured using medical grade materials in an ISO Class 7 cleanroom. RF-induced heating of the active guidewire prototype was tested in one gel phantom per ASTM 2182-19a, alone and in tandem with clinical metal-braided catheters. Real-time MRI visibility was tested in one gel phantom and in-vivo in two swine. Mechanical performance was compared with commercial equivalents. RESULTS: The active guidewire provided continuous "profile" shaft and tip visibility in-vitro and in-vivo, analogous to guidewire shaft-and-tip profiles under X-ray. The MRI signal signature matched simulation results. Maximum unscaled RF-induced temperature rise was 5.2°C and 6.5°C (3.47 W/kg local background specific absorption rate), alone and in tandem with a steel-braided catheter, respectively. Mechanical characteristics matched commercial comparator guidewires. CONCLUSION: The active guidewire was clearly visible via real-time MRI at 0.55T and exhibits a favorable geometric sensitivity profile depicting the guidewire continuously from shaft-to-tip including a unique curved-tip signature. RF-induced heating is clinically acceptable. This design allows safe device navigation through luminal structures and heart chambers. The detachable connector allows delivery and exchange of cardiovascular catheters while maintaining guidewire position. This enhanced guidewire design affords the expected performance of X-ray guidewires during human MRI catheterization.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Suínos , Humanos , Animais , Cateterismo Cardíaco/métodos , Desenho de Equipamento , Cateteres Cardíacos , Imagens de Fantasmas
5.
Micromachines (Basel) ; 13(9)2022 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-36144087

RESUMO

Molecularly imprinted polymers (MIPs) continue to gain increasing attention as functional materials due to their unique characteristics such as higher stability, simple preparation, robustness, better binding capacity, and low cost. In particular, MIP-coated inorganic nanoparticles have emerged as a promising platform for various biomedical applications ranging from drug delivery to bioimaging. The integration of MIPs with inorganic nanomaterials such as silica (SiO2), iron oxide (Fe3O4), gold (Au), silver (Ag), and quantum dots (QDs) combines several attributes from both components to yield highly multifunctional materials. These materials with a multicomponent hierarchical structure composed of an inorganic core and an imprinted polymer shell exhibit enhanced properties and new functionalities. This review aims to provide a general overview of key recent advances in the fabrication of MIPs-coated inorganic nanoparticles and highlight their biomedical applications, including drug delivery, biosensor, bioimaging, and bioseparation.

6.
Magn Reson Med ; 86(3): 1786-1801, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33860962

RESUMO

PURPOSE: This work aims to fabricate RF antenna components on metallic needle surfaces using biocompatible polyester tubing and conductive ink to develop an active interventional MRI needle for clinical use at 0.55 Tesla. METHODS: A custom computer numeric control-based conductive ink printing method was developed. Based on electromagnetic simulation results, thin-film RF antennas were printed with conductive ink and used to fabricate a medical grade, 20-gauge (0.87 mm outer diameter), 90-mm long active interventional MRI needle. The MRI visibility performance of the active needle prototype was tested in vitro in 1 gel phantom and in vivo in 1 swine. A nearly identical active needle constructed using a 44 American Wire Gauge insulated copper wire-wound RF receiver antenna was a comparator. The RF-induced heating risk was evaluated in a gel phantom per American Society for Testing and Materials (ASTM) 2182-19. RESULTS: The active needle prototype with printed RF antenna was clearly visible both in vitro and in vivo under MRI. The maximum RF-induced temperature rise of prototypes with printed RF antenna and insulated copper wire antenna after a 3.96 W/kg, 15 min. long scan were 1.64°C and 8.21°C, respectively. The increase in needle diameter was 98 µm and 264 µm for prototypes with printed RF antenna and copper wire-wound antenna, respectively. CONCLUSION: The active needle prototype with conductive ink printed antenna provides distinct device visibility under MRI. Variations on the needle surface are mitigated compared to use of a 44 American Wire Gauge copper wire. RF-induced heating tests support device RF safety under MRI. The proposed method enables fabrication of small diameter active interventional MRI devices having complex geometries, something previously difficult using conventional methods.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Animais , Condutividade Elétrica , Desenho de Equipamento , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Suínos , Temperatura
7.
Magn Reson Med ; 85(5): 2904-2914, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33347642

RESUMO

PURPOSE: This work aims to demonstrate the use of an "active" acousto-optic marker with enhanced visibility and reduced radiofrequency (RF) -induced heating for interventional MRI. METHODS: The acousto-optic marker was fabricated using bulk piezoelectric crystal and π-phase shifted fiber Bragg grating (FBGs) and coupled to a distal receiver coil on an 8F catheter. The received MR signal is transmitted over an optical fiber to mitigate RF-induced heating. A photodetector converts the optical signal into electrical signal, which is used as the input signal to the MRI receiver plug. Acousto-optic markers were characterized in phantom studies. RF-induced heating risk was evaluated according to ASTM 2182 standard. In vivo real-time tracking capability was tested in an animal model under a 0.55T scanner. RESULTS: Signal-to-noise ratio (SNR) levels suitable for real-time tracking were obtained by using high sensitivity FBG and piezoelectric transducer with resonance matched to Larmor frequency. Single and multiple marker coils integrated to 8F catheters were readout for position and orientation tracking by a single acousto-optic sensor. RF-induced heating was significantly reduced compared to a coax cable connected reference marker. Real-time distal tip tracking of an active device was demonstrated in an animal model with a standard real-time cardiac MR sequence. CONCLUSION: Acousto-optic markers provide sufficient SNR with a simple structure for real-time device tracking. RF-induced heating is significantly reduced compared to conventional active markers. Also, multiple RF receiver coils connected on an acousto-optic modulator can be used on a single catheter for determining catheter orientation and shape.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Imageamento por Ressonância Magnética , Animais , Catéteres , Desenho de Equipamento , Imagens de Fantasmas
8.
Magn Reson Imaging ; 77: 14-20, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33309924

RESUMO

INTRODUCTION: Visualization of passive devices during MRI-guided catheterizations often relies on a susceptibility artifact from the device itself or added susceptibility markers that impart a unique imaging signature. High-performance low field MRI systems offer reduced RF-induced heating of metallic devices during MRI-guided invasive procedures, but susceptibility artifacts are expected to diminish with field strength, reducing device visualization. In this study, field strength and orientation dependence of artifacts from susceptibility markers and metallic guidewires were evaluated using a prototype high-performance 0.55 T MRI system. MATERIALS AND METHODS: Artifact volume from nitinol and stainless steel passive susceptibility markers was quantified using histogram analysis of pixel intensities from three-dimensional gradient echo images at 0.55 T, 1.5 T and 3 T. In addition, visibility of commercially available clinical catheterization devices was compared between 0.55 T and 1.5 T using real-time bSSFP in phantoms and in vivo. RESULTS: A low-tensile strength stainless-steel marker produced field strength- and orientation-dependent artifact size (1.7 cm3, 1.95 cm3, 2.21 cm3 at 0.55 T, 1.5 T, 3 T, respectively). Whereas, a high-tensile strength steel marker, of the same alloy, produced field strength- and orientation-independent artifact size (3.35 cm3, 3.41 cm3, 3.42 cm3 at 0.55 T, 1.5 T, 3 T, respectively). Visibility of commercially available nitinol guidewires was reduced at 0.55 T, but imaging signature could be maintained using high-susceptibility stainless steel markers. DISCUSSION AND CONCLUSION: High-susceptibility stainless-steel markers generate field-independent artifacts between 0.55 T, 1.5 T and 3 T, indicating magnetic saturation at fields <0.55 T. Thus, artifact size can be tailored such that interventional devices produce identical imaging signatures across field strengths.


Assuntos
Artefatos , Cateterismo Cardíaco/instrumentação , Imageamento por Ressonância Magnética/métodos , Metais , Ligas , Humanos , Imagens de Fantasmas
9.
Ultrasonics ; 110: 106274, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33130362

RESUMO

Tissue-mimicking materials (TMMs) play a key role in the quality assurance of ultrasound diagnostic equipment and should have acoustic properties similar to human tissues. We propose a method to quantify the acoustic properties of TMM samples through the use of an 80 MHz Scanning Acoustic Microscopy (SAM), which provides micrometer resolution and fast data recording. We produced breast TMM samples in varying compositions that resulted in acoustic impedance values in the range of 1.373 ± 0.031 and 1.707 ± 0.036 MRayl. Additionally, liver TMM and blood mimicking fluid (BMF) samples were prepared that had acoustic impedance values of 1.693 ± 0.085 MRayl and 1.624 ± 0.006 MRayl, respectively. The characterization of the TMMs by SAM may provide reproducible and uniform acoustic reference data for tissue substitutes in a single-run microscopy experiment.


Assuntos
Materiais Biomiméticos , Microscopia Acústica/métodos , Acústica , Imagens de Fantasmas
10.
OSA Contin ; 3(3): 447-458, 2020 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-32457936

RESUMO

Fiber Bragg grating (FBG) based sensors have recently been introduced to the field of magnetic resonance imaging (MRI). Real-time MRI applications demand highly amplitude and phase sensitive MRI compatible sensors. Thus, a model and detailed analysis of FBG based ultrasound detection are required for designing better performing sensors. A hybrid FBG model incorporating numerical and FEA methods was developed and used for sensitivity and linearity analysis. The transfer matrix method was used for the modeling of optical modulation whereas FEA was used for pressure field calculations within the grating. The model was verified through reflection spectrum and acoustic pressure sensitivity testing of two π-phase shifted FBGs in a side slope read-out configuration. The sensitivity curves with respect to the operation point on the side slope was characterized in terms of amplitude and phase, and nonlinearity of the phase response has been quantified. Lastly, the impact of phase linearity of the FBG based acousto-optic sensor was tested under MRI when the sensor was used as a position marker and an analog phase shifter based solution was demonstrated.

11.
Med Biol Eng Comput ; 58(7): 1431-1443, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32319031

RESUMO

To the best of the authors' knowledge, testing the biocompatibility of graphene coatings can be considered as the first to demonstrate human carotid endothelial cell (HCtAEC) proliferation on Au, graphene oxide-coated Au (Au/GO), and reduced graphene oxide-coated Au (Au/rGO) surfaces. We hypothesized that stent material modified with graphene (G)-based coatings could be used as electrodes for electrical impedance spectroscopy (EIS) in monitoring cell cultures, i.e., endothelialization. Alamar Blue cell viability assay and cell staining and cell counting with optical images were performed. For EIS analysis, an EIS sensor consisting of Au surface electrodes was produced by the photolithographic technique. Surface characterizations were performed by considering scanning electron microscope (SEM) and water contact angle analyses. Results showed that GO and rGO coatings did not prevent neither the electrical measurements nor the cell proliferation and that rGO had a positive effect on HCtAEC proliferation. The rate of increase of impedance change from day 1 to day 10 was nearly fivefold for all electrode surfaces. Alamar Blue assay performed to monitor cell proliferation rates between groups, and rGO has shown the highest Alamar Blue reduction value of 43.65 ± 8.79%. Graphical abstract.


Assuntos
Artérias Carótidas/citologia , Técnicas de Cultura de Células/métodos , Espectroscopia Dielétrica/métodos , Ouro , Grafite , Adesão Celular , Técnicas de Cultura de Células/instrumentação , Proliferação de Células , Sobrevivência Celular , Espectroscopia Dielétrica/instrumentação , Células Endoteliais , Grafite/química , Humanos , Microscopia Eletrônica de Varredura
12.
J Cardiovasc Magn Reson ; 21(1): 16, 2019 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-30841903

RESUMO

BACKGROUND: Catheter designs incorporating metallic braiding have high torque control and kink resistance compared with unbraided alternatives. However, metallic segments longer than a quarter wavelength (~ 12 cm for 1.5 T scanner) are prone to radiofrequency (RF) induced heating during cardiovascular magnetic resonance (CMR) catheterization. We designed a braid-reinforced catheter with interrupted metallic segments to mitigate RF-induced heating yet retain expected mechanical properties for CMR catheterization. METHODS: We constructed metal wire braided 6 Fr catheter shaft subassemblies using electrically insulated stainless-steel wires and off-the-shelf biocompatible polymers. The braiding was segmented, in-situ, using lasers to create non-resonant wire lengths. We compared the heating and mechanical performance of segmented- with un-segmented- metal braided catheter shaft subassemblies. RESULTS: The braiding segmentation procedure did not significantly alter the structural integrity of catheter subassemblies, torque response, push-ability, or kink resistance compared with non-segmented controls. Segmentation shortened the electrical length of individually insulated metallic braids, and therefore inhibited resonance during CMR RF excitation. RF-induced heating was reduced below 2 °C under expected use conditions in vitro. CONCLUSION: We describe a simple modification to the manufacture of metallic braided catheters that will allow CMR catheterization without RF-induced heating under contemporary scanning conditions at 1.5 T. The proposed segmentation pattern largely preserves braid structure and mechanical integrity while interrupting electrical resonance. This inexpensive design may be applicable to both diagnostic and interventional catheters and will help to enable a range of interventional procedures using real time CMR.


Assuntos
Materiais Biocompatíveis , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Temperatura Alta , Imagem por Ressonância Magnética Intervencionista/instrumentação , Aço Inoxidável , Animais , Desenho de Equipamento , Falha de Equipamento , Teste de Materiais , Modelos Animais , Estresse Mecânico , Suínos , Porco Miniatura , Torque
13.
Biomed Opt Express ; 10(1): 242-251, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30775097

RESUMO

Biopsy needles with embedded force sensors can eliminate the needle deflection and the needle targeting failure risks during MRI guided biopsy procedures. Fabry-Pérot interferometry (FPI) based sensors are small, compact and immune to electromagnetic and RF interferences, and therefore they are suitable for needle guidance under MRI. In this work, an FPI based fiber optic force sensor design and its integration to an 18-gauge MRI compatible biopsy needle are presented. The custom designed FPI sensor provides a force measurement range up to 13 N with a resolution of 0.1 N through benchtop experiments. The MRI compatibility of the sensor was evaluated using a commercially available prostate phantom under MRI.

14.
IEEE Trans Biomed Eng ; 66(4): 1148-1154, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30188810

RESUMO

OBJECTIVE: The objective of this paper is to introduce an acousto-optic optical fiber sensor for tracking catheter position during interventional magnetic resonance imaging (MRI) to overcome RF induced heating of active markers. METHODS: The sensor uses a miniature coil coupled to a piezoelectric transducer, which is in turn mechanically connected to an optical fiber. The piezoelectric transducer converts the RF signal to acoustic waves in the optical fiber over a region including a fiber Bragg grating (FBG). The elastic waves in the fiber modulates the FBG geometry and hence the reflected light in the optical fiber. Since the coil is much smaller than the RF wavelength and the signal is transmitted on the dielectric optical fiber, the sensor effectively reduces RF induced heating risk. Proof of concept prototypes of the sensor are implemented using commercially available piezoelectric transducers and optical fibers with FBGs. The prototypes are characterized in a 1.5 T MRI system in comparison with an active tracking marker. RESULTS: Acousto-optical sensor shows linear response with flip angle and it can be used to detect signals from multiple coils for potential orientation detection. It has been successfully used to detect the position of a tacking coil in phantom in an imaging experiment. CONCLUSION: Acousto-optical sensing is demonstrated for tracking catheters during interventional MRI. Real-time operation of the sensor requires sensitivity improvements like using a narrow band FBG. SIGNIFICANCE: Acousto-optics provides a compact solution to sense RF signals in MRI with dielectric transmission lines.


Assuntos
Catéteres , Imagem por Ressonância Magnética Intervencionista/métodos , Fibras Ópticas , Desenho de Equipamento , Imagem por Ressonância Magnética Intervencionista/instrumentação , Imagens de Fantasmas , Transdutores
15.
MAGMA ; 30(1): 93-101, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27605033

RESUMO

OBJECTIVES: A new microfabrication method to produce low profile radio frequency (RF) resonant markers on catheter shafts was developed. A semi-active RF resonant marker incorporating a solenoid and a plate capacitor was constructed on the distal shaft of a 5 Fr guiding catheter. The resulting device can be used for interventional cardiovascular MRI procedures. MATERIALS AND METHODS: Unlike current semi-active device visualization techniques that require rigid and bulky analog circuit components (capacitor and solenoid), we fabricated a low profile RF resonant marker directly on guiding the catheter surface by thin film metal deposition and electroplating processes using a modified physical vapor deposition system. RESULTS: The increase of the overall device profile thickness caused by the semi-active RF resonant marker (130 µm thick) was lowered by a factor of 4.6 compared with using the thinnest commercial non-magnetic and rigid circuit components (600 µm thick). Moreover, adequate visibility performance of the RF resonant marker in different orientations and overall RF safety were confirmed through in vitro experiments under MRI successfully. CONCLUSION: The developed RF resonant marker on a clinical grade 5 Fr guiding catheter will enable several interventional congenital heart disease treatment procedures under MRI.


Assuntos
Coração/diagnóstico por imagem , Imagem por Ressonância Magnética Intervencionista/instrumentação , Imagem por Ressonância Magnética Intervencionista/métodos , Materiais Biocompatíveis/química , Catéteres , Capacitância Elétrica , Galvanoplastia , Desenho de Equipamento , Humanos , Miocárdio/patologia , Imagens de Fantasmas , Polímeros/química , Ondas de Rádio , Xilenos/química
17.
JACC Basic Transl Sci ; 1(5): 376-383, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27631028

RESUMO

BACKGROUND: Diagnostic yield of endomyocardial biopsy is low, particularly in disease that affects the myocardium in a non-uniform distribution. We hypothesized that real-time MRI guidance could improve the yield through targeted biopsy of focal myocardial pathology. METHODS: An animal model of focal myocardial pathology was created by infusing 3mL of fluorescent microspheres (NuFlow Hydrocoat, 15µm diameter, 5 million spheres/mL) followed by 2mL of 100% ethanol to a branch coronary artery. Animals were survived for minimum 14days, before undergoing MRI guided endomyocardial biopsy using a custom 6.5Fr active visualization MRI-conditional bioptome and X-ray guided biopsy using a commercial bioptome. Specimens were analyzed using a dissecting microscope under ultraviolet light to determine the proportion of 'on-target' specimens containing fluorescent microspheres. RESULTS: A total of 77 specimens were obtained using real-time MRI guidance and 87 using X-ray guidance, in five animals. Specimens obtained with the MRI-conditional bioptome were smaller compared with the commercial X-ray bioptome. Real-time MRI guidance significantly increased the diagnostic yield of endomyocardial biopsy (82% vs. 56% on-target biopsy specimens with real-time MRI vs. X-ray guidance, p<0.01). CONCLUSIONS: Endomyocardial biopsy performed using real-time MRI guidance is feasible and significantly improves the diagnostic yield compared with X-ray fluoroscopy guidance.

18.
An Bras Dermatol ; 91(4): 442-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27579738

RESUMO

BACKGROUND: Vitiligo is an acquired pigmentary skin disorder affecting 0.1-4% of the general population. The nails may be affected in patients with an autoimmune disease such as psoriasis, and in those with alopecia areata. It has been suggested that nail abnormalities should be apparent in vitiligo patients. OBJECTIVE: We sought to document the frequency and clinical presentation of nail abnormalities in vitiligo patients compared to healthy volunteers. We also examined the correlations between nail abnormalities and various clinical parameters. METHODS: This study included 100 vitiligo patients and 100 healthy subjects. Full medical histories were collected from the subjects, who underwent thorough general and nail examinations. All nail changes were noted. In the event of clinical suspicion of a fungal infection, additional mycological investigations were performed. RESULTS: Nail abnormalities were more prevalent in the patients (78%) than in the controls (55%) (p=0.001). Longitudinal ridging was the most common finding (42%), followed by (in descending order): leukonychia, an absent lunula, onycholysis, nail bed pallor, onychomycosis, splinter hemorrhage and nail plate thinning. The frequency of longitudinal ridging was significantly higher in patients than in controls (p<0.001). CONCLUSIONS: Nail abnormalities were more prevalent in vitiligo patients than in controls. Systematic examination of the nails in such patients is useful because nail abnormalities are frequent. However, the causes of such abnormalities require further study. Longitudinal ridging and leukonychia were the most common abnormalities observed in this study.


Assuntos
Unhas Malformadas/epidemiologia , Vitiligo/epidemiologia , Adolescente , Adulto , Idoso , Estudos de Casos e Controles , Criança , Pré-Escolar , Feminino , Humanos , Hipopigmentação/epidemiologia , Masculino , Pessoa de Meia-Idade , Doenças da Unha/congênito , Doenças da Unha/epidemiologia , Unhas Malformadas/etiologia , Unhas Malformadas/patologia , Prevalência , Estatísticas não Paramétricas , Turquia/epidemiologia , Vitiligo/complicações , Vitiligo/patologia , Adulto Jovem
19.
An. bras. dermatol ; 91(4): 442-445, July-Aug. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-792432

RESUMO

Abstract: Background: Vitiligo is an acquired pigmentary skin disorder affecting 0.1-4% of the general population. The nails may be affected in patients with an autoimmune disease such as psoriasis, and in those with alopecia areata. It has been suggested that nail abnormalities should be apparent in vitiligo patients. Objective: We sought to document the frequency and clinical presentation of nail abnormalities in vitiligo patients compared to healthy volunteers. We also examined the correlations between nail abnormalities and various clinical parameters. Methods: This study included 100 vitiligo patients and 100 healthy subjects. Full medical histories were collected from the subjects, who underwent thorough general and nail examinations. All nail changes were noted. In the event of clinical suspicion of a fungal infection, additional mycological investigations were performed. Results: Nail abnormalities were more prevalent in the patients (78%) than in the controls (55%) (p=0.001). Longitudinal ridging was the most common finding (42%), followed by (in descending order): leukonychia, an absent lunula, onycholysis, nail bed pallor, onychomycosis, splinter hemorrhage and nail plate thinning. The frequency of longitudinal ridging was significantly higher in patients than in controls (p<0.001). Conclusions: Nail abnormalities were more prevalent in vitiligo patients than in controls. Systematic examination of the nails in such patients is useful because nail abnormalities are frequent. However, the causes of such abnormalities require further study. Longitudinal ridging and leukonychia were the most common abnormalities observed in this study.


Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Adulto Jovem , Vitiligo/epidemiologia , Unhas Malformadas/epidemiologia , Turquia/epidemiologia , Vitiligo/complicações , Vitiligo/patologia , Estudos de Casos e Controles , Prevalência , Hipopigmentação/epidemiologia , Estatísticas não Paramétricas , Doenças da Unha/congênito , Doenças da Unha/epidemiologia , Unhas Malformadas/etiologia , Unhas Malformadas/patologia
20.
JACC Cardiovasc Interv ; 9(9): 959-70, 2016 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-27085581

RESUMO

OBJECTIVES: The aim of this study was to test the hypothesis that real-time magnetic resonance imaging (MRI) would enable closed-chest percutaneous cavopulmonary anastomosis and shunt by facilitating needle guidance along a curvilinear trajectory, around critical structures, and between a superior vena cava "donor" vessel and a pulmonary artery "target." BACKGROUND: Children with single-ventricle physiology require multiple open heart operations for palliation, including sternotomies and cardiopulmonary bypass. The reduced morbidity of a catheter-based approach would be attractive. METHODS: Fifteen naive swine underwent transcatheter cavopulmonary anastomosis and shunt creation under 1.5-T MRI guidance. An MRI antenna-needle was advanced from the superior vena cava into the target pulmonary artery bifurcation using real-time MRI guidance. In 10 animals, balloon-expanded off-the-shelf endografts secured a proximal end-to-end caval anastomosis and a distal end-to-side pulmonary anastomosis that preserved blood flow to both branch pulmonary arteries. In 5 animals, this was achieved with a novel, purpose-built, self-expanding device. RESULTS: Real-time MRI needle access of target vessels (pulmonary artery), endograft delivery, and superior vena cava shunt to pulmonary arteries were successful in all animals. All survived the procedure without complications. Intraprocedural real-time MRI, post-procedural MRI, x-ray angiography, computed tomography, and necropsy showed patent shunts with bidirectional pulmonary artery blood flow. CONCLUSIONS: MRI guidance enabled a complex, closed-chest, beating-heart, pediatric, transcatheter structural heart procedure. In this study, MRI guided trajectory planning and reproducible, reliable bidirectional cavopulmonary shunt creation.


Assuntos
Cateterismo Cardíaco , Derivação Cardíaca Direita/métodos , Imagem por Ressonância Magnética Intervencionista , Artéria Pulmonar/diagnóstico por imagem , Veia Cava Superior/diagnóstico por imagem , Animais , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Estudos de Viabilidade , Derivação Cardíaca Direita/instrumentação , Imagem por Ressonância Magnética Intervencionista/instrumentação , Modelos Animais , Desenho de Prótese , Stents , Sus scrofa , Fatores de Tempo