1.
J Chromatogr A ; 1375: 76-81, 2015 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-25497579

RESUMO

The performance of curtain flow chromatography column technology with MS detection was evaluated for the analysis of labile compounds. The curtain flow column design allows for separations that are faster and/or more sensitive than conventional columns, depending on how exactly the curtain flow column is configured. For example, when mass spectral detection is employed, the curtain flow column can yield separations that are 5-times faster than conventional columns when the curtain flow and the conventional columns have the same internal diameter. Or when the internal diameter of the conventional column is reduced in order to yield the same analytical through-put as the curtain flow column, the sensitivity on the curtain flow column can be as much as 66-fold higher than the conventional column. As a consequence of the higher analytical through-put less standardization is required in the analysis of labile compounds because less sample degradation is apparent. Consequently the sample integrity is preserved yielding data of a higher quality.


Assuntos
Aminoácidos/análise , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida/métodos
2.
J Chromatogr A ; 1305: 102-8, 2013 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-23891379

RESUMO

A preliminary investigation was undertaken to assess the performance of a new chromatography column technology in applications involving liquid chromatography coupled to mass spectrometry. The new column design allows mobile phase and solute to be extracted from the radial central region of the column, which reduces the solvent load to the mass spectrometer and improves separation efficiency. Effectively the column functions as a 'wall-less' column. The advantages of this design is that the analysis through-put can be increased by a factor of five, while at the same time there is a reduction in baseline noise, which results in an increase in the signal to noise response by up to 10-fold in comparison to standard columns with the same internal diameter and approaching 66-fold in comparison to standard columns with the same virtual internal diameter.


Assuntos
Aminoácidos Essenciais/isolamento & purificação , Cromatografia Líquida de Alta Pressão/instrumentação , Espectrometria de Massas em Tandem/métodos , Limite de Detecção