Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
2.
Rev Sci Instrum ; 91(8): 083503, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32872937

RESUMO

Coated glass targets are a key component of the Wendelstein 7-X laser blow-off system that is used for impurity transport studies. The preparation and analysis of these glass targets as well as their performance is examined in this paper. The glass targets have a high laser damage threshold and are coated via physical vapor deposition with µm thick films. In addition, nm-thin layers of Ti are used as an interface layer for improved ablation efficiency and reduced coating stress. Hence, the metallic or ceramic coating has a lateral homogeneity within 2% and contaminants less than 5%, being optimal for laser ablation processing. With this method, a short (few ms) and well defined pulse of impurities with about 1017 particles can be injected close to the last closed flux surface of Wendelstein 7-X. In particular, a significant amount of atoms with a velocity of about 1 km/s enters the plasma within 1 ms. The atoms are followed by a negligible concentration of slower clusters and macro-particles. This qualifies the use of the targets and applied laser settings for impurity transport studies with the laser blow-off system in Wendelstein 7-X.

3.
Rev Sci Instrum ; 89(7): 073505, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30068134

RESUMO

We present a detailed overview and first results of the new laser blow-off system on the stellarator Wendelstein 7-X. The system allows impurity transport studies by the repetitive and controlled injection of different tracer ions into the plasma edge. A Nd:YAG laser is used to ablate a thin metal film, coated on a glass plate, with a repetition rate of up to 20 Hz. A remote-controlled adjustable optical system allows the variation of the laser spot diameter and enables the spot positioning to non-ablated areas on the target between laser pulses. During first experiments, clear spectral lines from higher ionization stages of the tracer ions have been observed in the X-ray to the extreme ultraviolet spectral range. The temporal behavior of the measured emission allows the estimate of transport properties, e.g., impurity transport times in the order of 100 ms. Although the strong injection of impurities is well detectable, the global plasma parameters are barely changed.

5.
Rev Sci Instrum ; 89(4): 043509, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29716310

RESUMO

Diagnostic alkali atom (e.g., lithium) beams are routinely used to diagnose magnetically confined plasmas, namely, to measure the plasma electron density profile in the edge and the scrape off layer region. A light splitting optics system was installed into the observation system of the lithium beam emission spectroscopy diagnostic at the Joint European Torus (JET) tokamak, which allows simultaneous measurement of the beam light emission with a spectrometer and a fast avalanche photodiode (APD) camera. The spectrometer measurement allows density profile reconstruction with ∼10 ms time resolution, absolute position calculation from the Doppler shift, spectral background subtraction as well as relative intensity calibration of the channels for each discharge. The APD system is capable of measuring light intensities on the microsecond time scale. However ∼100 µs integration is needed to have an acceptable signal to noise ratio due to moderate light levels. Fast modulation of the beam up to 30 kHz is implemented which allows background subtraction on the 100 µs time scale. The measurement covers the 0.9 < ρpol < 1.1 range with 6-10 mm optical resolution at the measurement location which translates to 3-5 mm radial resolution at the midplane due to flux expansion. An automated routine has been developed which performs the background subtraction, the relative calibration, and the comprehensive error calculation, runs a Bayesian density reconstruction code, and loads results to the JET database. The paper demonstrates the capability of the APD system by analyzing fast phenomena like pellet injection and edge localized modes.

6.
Rev Sci Instrum ; 89(1): 013502, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29390718

RESUMO

A special video camera has been developed for the 10-camera overview video system of the Wendelstein 7-X (W7-X) stellarator considering multiple application needs and limitations resulting from this complex long-pulse superconducting stellarator experiment. The event detection intelligent camera (EDICAM) uses a special 1.3 Mpixel CMOS sensor with non-destructive read capability which enables fast monitoring of smaller Regions of Interest (ROIs) even during long exposures. The camera can perform simple data evaluation algorithms (minimum/maximum, mean comparison to levels) on the ROI data which can dynamically change the readout process and generate output signals. Multiple EDICAM cameras were operated in the first campaign of W7-X and capabilities were explored in the real environment. Data prove that the camera can be used for taking long exposure (10-100 ms) overview images of the plasma while sub-ms monitoring and even multi-camera correlated edge plasma turbulence measurements of smaller areas can be done in parallel. These latter revealed that filamentary turbulence structures extend between neighboring modules of the stellarator. Considerations emerging for future upgrades of this system and similar setups on future long-pulse fusion experiments such as ITER are discussed.

7.
Rev Sci Instrum ; 87(11): 11D304, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910389

RESUMO

Wendelstein 7-X, a superconducting optimized stellarator built in Greifswald/Germany, started its first plasmas with the last closed flux surface (LCFS) defined by 5 uncooled graphite limiters in December 2015. At the end of the 10 weeks long experimental campaign (OP1.1) more than 20 independent diagnostic systems were in operation, allowing detailed studies of many interesting plasma phenomena. For example, fast neutral gas manometers supported by video cameras (including one fast-frame camera with frame rates of tens of kHz) as well as visible cameras with different interference filters, with field of views covering all ten half-modules of the stellarator, discovered a MARFE-like radiation zone on the inboard side of machine module 4. This structure is presumably triggered by an inadvertent plasma-wall interaction in module 4 resulting in a high impurity influx that terminates some discharges by radiation cooling. The main plasma parameters achieved in OP1.1 exceeded predicted values in discharges of a length reaching 6 s. Although OP1.1 is characterized by short pulses, many of the diagnostics are already designed for quasi-steady state operation of 30 min discharges heated at 10 MW of ECRH. An overview of diagnostic performance for OP1.1 is given, including some highlights from the physics campaigns.

8.
Rev Sci Instrum ; 87(2): 023508, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931850

RESUMO

Experiments have been performed at ASDEX Upgrade, aiming to investigate the impact of lithium in an all-metal-wall tokamak and attempting to enhance the pedestal operational space. For this purpose, a lithium pellet injector has been developed, capable of injecting pellets carrying a particle content ranging from 1.82 × 10(19) atoms (0.21 mg) to 1.64 × 10(20) atoms (1.89 mg). The maximum repetition rate is about 2 Hz. Free flight launch from the torus outboard side without a guiding tube was realized. In such a configuration, angular dispersion and speed scatter are low, and a transfer efficiency exceeding 90% was achieved in the test bed. Pellets are accelerated in a gas gun; hence special care was taken to avoid deleterious effects by the propellant gas pulse. Therefore, the main plasma gas species was applied as propellant gas, leading to speeds ranging from 420 m/s to 700 m/s. In order to minimize the residual amount of gas to be introduced into the plasma vessel, a large expansion volume equipped with a cryopump was added into the flight path. In view of the experiments, an optimal propellant gas pressure of 50 bars was chosen for operation, since at this pressure maximum efficiency and low propellant gas flux coincide. This led to pellet speeds of 585 m/s ± 32 m/s. Lithium injection has been achieved at ASDEX Upgrade, showing deep pellet penetration into the plasma, though pedestal broadening has not been observed yet.

9.
Bone Joint J ; 98-B(3): 374-80, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26920963

RESUMO

AIMS: Glenoid bone loss can be a challenging problem when revising a shoulder arthroplasty. Precise pre-operative planning based on plain radiographs or CT scans is essential. We have investigated a new radiological classification system to describe the degree of medialisation of the bony glenoid and that will indicate the amount of bone potentially available for supporting a glenoid component. It depends on the relationship between the most medial part of the articular surface of the glenoid with the base of the coracoid process and the spinoglenoid notch: it classifies the degree of bone loss into three types. It also attempts to predict the type of glenoid reconstruction that may be possible (impaction bone grafting, structural grafting or simple non-augmented arthroplasty) and gives guidance about whether a pre-operative CT scan is indicated. PATIENTS AND METHODS: Inter-method reliability between plain radiographs and CT scans was assessed retrospectively by three independent observers using data from 39 randomly selected patients. Inter-observer reliability and test-retest reliability was tested on the same cohort using Cohen's kappa statistics. Correlation of the type of glenoid with the Constant score and its pain component was analysed using the Kruskal-Wallis method on data from 128 patients. Anatomical studies of the scapula were reviewed to explain the findings. RESULTS: Excellent inter-method reliability, inter-observer and test-retest reliability were seen. The system did not correlate with the Constant score, but correlated well with its pain component. TAKE HOME MESSAGE: Our system of classification is a helpful guide to the degree of glenoid bone loss when embarking on revision shoulder arthroplasty.


Assuntos
Artroplastia de Substituição/métodos , Cavidade Glenoide/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Articulação do Ombro/cirurgia , Transplante Ósseo/métodos , Humanos , Variações Dependentes do Observador , Cuidados Pré-Operatórios/métodos , Reoperação/métodos , Reprodutibilidade dos Testes , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X
10.
Bone Joint J ; 97-B(1): 83-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25568418

RESUMO

The LockDown device (previously called Surgilig) is a braided polyester mesh which is mostly used to reconstruct the dislocated acromioclavicular joint. More than 11,000 have been implanted worldwide. Little is known about the tissue reaction to the device nor to its wear products when implanted in an extra-articular site in humans. This is of importance as an adverse immunological reaction could result in osteolysis or damage to the local tissues, thereby affecting the longevity of the implant. We analysed the histology of five LockDown implants retrieved from five patients over the last seven years by one of the senior authors. Routine analysis was carried out in all five cases and immunohistochemistry in one. The LockDown device acts as a scaffold for connective tissue which forms an investing fibrous pseudoligament. The immunological response at the histological level seems favourable with a limited histiocytic and giant cell response to micron-sized wear particles. The connective tissue envelope around the implant is less organised than a native ligament.


Assuntos
Articulação Acromioclavicular/cirurgia , Ligamentos Articulares/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Falha de Prótese , Articulação Acromioclavicular/fisiopatologia , Adulto , Remoção de Dispositivo , Análise de Falha de Equipamento , Feminino , Humanos , Imuno-Histoquímica , Luxações Articulares/cirurgia , Masculino , Pessoa de Meia-Idade , Poliésteres/efeitos adversos , Próteses e Implantes , Procedimentos de Cirurgia Plástica/efeitos adversos , Reoperação/métodos , Estudos de Amostragem , Sensibilidade e Especificidade
11.
Rev Sci Instrum ; 85(11): 11D818, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430231

RESUMO

An overview of the diagnostics which are essential for the first operational phase of Wendelstein 7-X and the set of diagnostics expected to be ready for operation at this time are presented. The ongoing investigations of how to cope with high levels of stray Electron Cyclotron Resonance Heating (ECRH) radiation in the ultraviolet (UV)/visible/infrared (IR) optical diagnostics are described.

12.
Rev Sci Instrum ; 83(10): 10D730, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126902

RESUMO

The critical issues in the development of diagnostics, which need to work robust and reliable under quasi-steady state conditions for the discharge durations of 30 min and which cannot be maintained throughout the one week duration of each operation phase of the Wendelstein 7-X stellarator, are being discussed.

13.
Rev Sci Instrum ; 81(10): 10E133, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033995

RESUMO

The status of the diagnostic developments for the quasistationary operable stellarator Wendelstein 7-X (maximum pulse length of 30 min at 10 MW ECRH heating at 140 GHz) will be reported on. Significant emphasis is being given to the issue of ECRH stray radiation shielding of in-vessel diagnostic components, which will be critical at high density operation requiring O2 and OXB heating.

14.
Phys Rev Lett ; 104(18): 185003, 2010 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-20482186

RESUMO

We report the identification of a localized current structure inside the JET plasma. It is a field-aligned closed helical ribbon, carrying current in the same direction as the background current profile (cocurrent), rotating toroidally with the ion velocity (corotating). It appears to be located at a flat spot in the plasma pressure profile, at the top of the pedestal. The structure appears spontaneously in low density, high rotation plasmas, and can last up to 1.4 s, a time comparable to a local resistive time. It considerably delays the appearance of the first edge localized mode.

15.
Rev Sci Instrum ; 79(10): 10F337, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044644

RESUMO

The stellarator Wendelstein 7-X will allow for quasicontinuous operation with the duration only being limited to two 30 min discharges per day, at a continuous heating power of 10 MW electron cyclotron resonance heating (ECRH) at 140 GHz, by the capacity of the cooling water reservoir. This will result in high thermal loads on all plasma facing components of 50-100 kW/m(2) from radiation alone and of up to about 500 kW/m(2) on components additionally exposed to convective loads. In high density scenarios toroidally varying ECRH stray radiation levels of 50-200 kW/m(2) need to be coped with, requiring careful material selection and different shielding and hardening techniques. Furthermore, a gradual buildup of coatings on plasma facing optical components, which without any measures being taken, would lead to high transmission losses already within a few days of long pulse operation (equivalent to about 1 year of operation in pulsed devices like JET or ASDEX-upgrade) and therefore needs to be prevented as much as possible. In addition in situ cleaning as well as absolute calibration techniques need to be developed for all plasma facing optical systems. Here we report about some of our efforts to find, for various types of diagnostics, ways to cope with these adverse effects. Moreover, we give a few examples for individual diagnostic specific issues with respect to quasicontinuous operation, such as the development of a special integrator for the magnetic diagnostics as well as special interferometer types which can cope with unavoidable vibrations and slow path length changes due to, e.g., thermal expansion of the plasma vessel.

16.
Rev Sci Instrum ; 79(3): 033501, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18377004

RESUMO

In situ commissioning of the Blower-gun injector for launching cryogenic deuterium pellets at ASDEX Upgrade tokamak was performed. This injector is designed for high repetitive launch of small pellets for edge localised modes pacing experiments. During the investigation the final injection geometry was simulated with pellets passing to the torus through a 5.5 m long guiding tube. For investigation of pellet quality at launch and after tube passage laser flash camera shadowgraphy diagnostic units before and after the tube were installed. As indicator of pellet quality we adopted the pellet mass represented by the volume of the main remaining pellet fragment. Since only two-dimensional (2D) shadow images were obtained, a reconstruction of the full three-dimensional pellet body had to be performed. For this the image was first converted into a 1-bit version prescribing an exact 2D contour. From this contour the expected value of the volume was calculated by Bayesian analysis taking into account the likely cylindrical shape of the pellet. Under appropriate injection conditions sound pellets with more than half of their nominal mass are detected after acceleration; the passage causes in average an additional loss of about 40% to the launched mass. Analyzing pellets arriving at tube exit allowed for deriving the injector's optimized operational conditions. For these more than 90% of the pellets were arriving with sound quality when operating in the frequency range 5-50 Hz.

17.
Rev Sci Instrum ; 78(2): 023504, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17578110

RESUMO

One of the main challenges posed recently on pellet launcher systems in fusion-oriented plasma physics is the control of the plasma edge region. Strong energy bursts ejected from the plasma due to edge localized modes (ELMs) can form a severe threat for in-vessel components but can be mitigated by sufficiently frequent triggering of the underlying instabilities using hydrogen isotope pellet injection. However, pellet injection systems developed mainly for the task of ELM control, keeping the unwanted pellet fueling minimized, are still missing. Here, we report on a novel system developed under the premise of its suitability for control and mitigation of plasma edge instabilities. The system is based on the blower gun principle and is capable of combining high repetition rates up to 143 Hz with low pellet velocities. Thus, the flexibility of the accessible injection geometry can be maximized and the pellet size kept low. As a result the new system allows for an enhancement in the tokamak operation as well as for more sophisticated experiments investigating the underlying physics of the plasma edge instabilities. This article reports on the design of the new system, its main operational characteristics as determined in extensive test bed runs, and also its first test at the tokamak experiment ASDEX Upgrade.

18.
J Chromatogr Sci ; 42(5): 259-62, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15189599

RESUMO

A method is presented for the routine analysis of amphetamine, methamphetamine, and related compounds in urine with gas chromatography coupled with mass spectrometry operated in the selective ion monitoring mode. The analytes are isolated by liquid-liquid extraction and are derivatized with trifluoroacetic anhydride. 3,4-Methylenedioxy-methamphetamine-D(5) is employed as the internal standard. Standard solutions are prepared using spiked urine samples, which are subjected to all phases of sample preparation. Disposable deactivated glass containers are employed throughout the process.


Assuntos
Anfetaminas/urina , Cromatografia Gasosa-Espectrometria de Massas/métodos , Metanfetamina/urina , Detecção do Abuso de Substâncias/métodos , Humanos , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Can J Gastroenterol ; 14(7): 588-92, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10978945

RESUMO

BACKGROUND: Ultrasound can visualize significant portions of the upper and lower esophagus; it is without any instrumental interference in real conditions and displays events in motion. PURPOSE: To study the events that occur during swallowing and gastroesophageal reflux. PATIENTS AND METHODS: Group 1 comprised 25 patients with retrosternal complaints, selected for esophageal surface ultrasonography for endoscopic signs of esophagitis. Group 2 comprised 25 patients who underwent initial transabdominal ultrasonography. For 3 to 6 h before ultrasonography, nothing was given by mouth to the 50 patients labelled as having gastroesophageal reflux disease (GERD). Ultrasonography was then performed for 15 to 20 mins after drinking one mouthful of water or tea, or swallowing some saliva to provoke reflux. The events were recorded on videotape rolls. Endoscopy was carried out in all 50 cases; in 46 cases (21 and 25 from groups 1 and 2, respectively), gastric acidity and bacteriology were subsequently examined (test meal). Manometry and pH were not measured to avoid provocation of reflux by the instruments. Thirty patients without any esophageal complaints or signs of esophagitis (though suffering from gastric and duodenal diseases) were designated as the control group (group 3). The available results were compared. RESULTS: In 32 of 46 patients diagnosed with GERD (69.5% in groups 1 and 2), a special kind of reflux was observed by ultrasonography: a slow, trickling reflux of the gastric content was seen, mostly after swallowing. A fast clearance followed four to six episodes of the trickling reflux, only after an interval of 0.5 to 2 mins. Only fast refluxes and immediate clearance were observed in the control group. CONCLUSIONS: The observations above may indicate a special form of gastroesophageal reflux, namely, a slow, trickling form of it. It can be responsible for the development of GERD. Fast reflux and immediate clearance are common; however, this special trickling form was observed only in GERD patients. This may explain a number of often contradictory measurements and can make the effect of cisapride more understandable. A test meal is always necessary to distinguish a bilious reflux from an acidic one, because only the latter may require aggressive antacidic treatment.


Assuntos
Esôfago/fisiopatologia , Refluxo Gastroesofágico/diagnóstico por imagem , Refluxo Gastroesofágico/fisiopatologia , Adulto , Biópsia , Endoscopia do Sistema Digestório , Esôfago/diagnóstico por imagem , Esôfago/patologia , Feminino , Refluxo Gastroesofágico/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Peristaltismo , Ultrassonografia
20.
Fogorv Sz ; 90(11): 327-32, 1997 Nov.
Artigo em Húngaro | MEDLINE | ID: mdl-9424441

RESUMO

The authors reviewed the adverse effects. The main effects are: demineralisation; gingivitis hyperplastica, mucogingival and marginal attachment bone loss, long-term-effects; pulp damage and devitalisation of teeth; apical and marginal root resorption; temporomandibular dysfunction.


Assuntos
Ortodontia Corretiva/efeitos adversos , Hiperplasia Gengival/etiologia , Gengivite/etiologia , Humanos , Reabsorção da Raiz/etiologia , Síndrome da Disfunção da Articulação Temporomandibular/etiologia , Desmineralização do Dente/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA