2.
J Med Syst ; 40(3): 58, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26660689

RESUMO

In 2010, the Addendum D to ASHRAE Standard 170, "Ventilation of healthcare facilities," lowered the minimum relative humidity (RH) requirement of anesthetizing locations (including operating rooms, operating/surgical cystoscopic rooms, delivery rooms (Caesarean), recovery rooms, critical and intensive care, newborn intensive care, treatment rooms, trauma rooms (crisis or shock), laser eye rooms, newborn nursery suites, and endoscopy rooms) from 30 % to 20 %. The new minimum limit was adopted based on the results of a review paper that suggested that lowering humidity levels will have little or no impact on providing a safe environment for patients, staff, or medical equipment. That review paper reached this conclusion by assuming that there were no medical device failures due to electrostatic discharge (ESD). However, in an examination of the FDA's MAUDE database of reported defects and recalls, we identified numerous medical device failures explicitly due to ESD. This paper presents technical reliability and safety concerns regarding the new guidelines and recommends that such changes should not be implemented and that the guidelines should be revoked.


Assuntos
Falha de Equipamento , Umidade/normas , Salas Cirúrgicas/normas , Eletricidade Estática/efeitos adversos , Ventilação/normas , Humanos , Reprodutibilidade dos Testes
3.
Stud Health Technol Inform ; 184: 225-9, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23400161

RESUMO

This paper introduces three geometric features, from deformed shape of a soft tissue, which demonstrate good correlation with probing force and maximum local stress. Using FEM simulation, 2D and 3D model of an in vivo porcine liver was built for different probing tasks. Maximum deformation angle, maximum deformation depth and width of displacement constraint of the reconstructed shape of the deformed body were calculated. Two neural networks were trained from these features and the calculated interaction forces. The features are shown to have high potential to provide force estimation either for haptic devices or to assess the damage to the tissue in large deformations of up to 40%.


Assuntos
Hepatectomia/métodos , Laparoscopia/instrumentação , Fígado/anatomia & histologia , Fígado/fisiologia , Modelos Biológicos , Cirurgia Assistida por Computador/métodos , Interface Usuário-Computador , Simulação por Computador , Dureza/fisiologia , Humanos , Laparoscopia/métodos , Estresse Mecânico