Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Cureus ; 13(10): e18473, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34754638

RESUMO

PURPOSES: To evaluate whether the auto-planning (AP) module can achieve clinically acceptable treatment plans for lung stereotactic body radiotherapy (SBRT) and to evaluate the effectiveness of a dose prediction model. METHODS: Twenty lung SBRT cases planned manually with 50 Gy in five fractions were replanned using the Pinnacle (Philips Radiation Oncology Systems, Fitchburg, WI) AP module according to the dose constraint tables from the Radiation Therapy Oncology Group (RTOG) 0813 protocol. Doses to the organs at risk (OAR) were compared between the manual and AP plans. Using a dose prediction model from a commercial product, PlanIQ (Sun Nuclear Corporation, Melbourne, FL), we also compared OAR doses from AP plans with predicted doses. RESULTS: All manual and AP plans achieved clinically required dose coverage to the target volumes. The AP plans achieved equal or better OAR sparing when compared to the manual plans, most noticeable in the maximum doses of the spinal cord, ipsilateral brachial plexus, esophagus, and trachea. Predicted doses to the heart, esophagus, and trachea were highly correlated with the doses of these OARs from the AP plans with the highest correlation coefficient of 0.911, 0.823, and 0.803, respectively. CONCLUSION: Auto-planning for lung SBRT improved OAR sparing while keeping the same dose coverage to the tumor. The dose prediction model can provide useful planning dose guidance.

2.
Pract Radiat Oncol ; 7(3): e215-e222, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28110939

RESUMO

PURPOSE: Process consistency in planning and delivery of radiation therapy is essential to maintain patient safety and treatment quality and efficiency. Ensuring the timely completion of each critical clinical task is one aspect of process consistency. The purpose of this work is to report our experience in implementing a quantitative metric and automatic auditing program (QMAP) with a goal of improving the timely completion of critical clinical tasks. METHODS AND MATERIALS: Based on our clinical electronic medical records system, we developed a software program to automatically capture the completion timestamp of each critical clinical task while providing frequent alerts of potential delinquency. These alerts were directed to designated triage teams within a time window that would offer an opportunity to mitigate the potential for late completion. Since July 2011, 18 metrics were introduced in our clinical workflow. We compared the delinquency rates for 4 selected metrics before the implementation of the metric with the delinquency rate of 2016. One-tailed Student t test was used for statistical analysis RESULTS: With an average of 150 daily patients on treatment at our main campus, the late treatment plan completion rate and late weekly physics check were reduced from 18.2% and 8.9% in 2011 to 4.2% and 0.1% in 2016, respectively (P < .01). The late weekly on-treatment physician visit rate was reduced from 7.2% in 2012 to <1.6% in 2016. The yearly late cone beam computed tomography review rate was reduced from 1.6% in 2011 to <0.1% in 2016. CONCLUSIONS: QMAP is effective in reducing late completions of critical tasks, which can positively impact treatment quality and patient safety by reducing the potential for errors resulting from distractions, interruptions, and rush in completion of critical tasks.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde/métodos , Radioterapia (Especialidade)/métodos , Radioterapia (Especialidade)/organização & administração , Software , Registros Eletrônicos de Saúde , Humanos , Segurança do Paciente , Médicos , Planejamento da Radioterapia Assistida por Computador/métodos , Fluxo de Trabalho
3.
Pract Radiat Oncol ; 5(5): e437-e442, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25899222

RESUMO

PURPOSE: To ascertain the safety and efficacy of permanent prostate brachytherapy (PPB) in early prostate cancer patients who have undergone previous total proctocolectomy and J-pouch anastomosis for inflammatory bowel disease. METHODS AND MATERIALS: We identified 10 patients with a previous history of prostate cancer and J-pouch anastomosis from our institutional review board-approved database. Seven patients had PPB and 3 had prostatectomy. Only patients treated with PPB were included. Patient records were reviewed to collect data on treatment-related toxicity and oncological outcomes. RESULTS: All 7 patients who underwent PPB had low- to intermediate-risk prostate cancer. The mean prostatic volume was 24.40 mL and the average number of iodine-125 seeds implanted was 84. Postimplant dosimetric calculations showed a mean prostate volume receiving 100% of the prescribed dose (V100) of 88.76%, V150 of 45.23%, V200 of 16.79%, radiation dose delivered to 90% of the prostate of 147.89 Gy, volume of ileal pouch receiving 100% of the prescribed dose of 0.164 mL, and volume of ileal pouch receiving 50% of the prescribed dose of 1.38 mL. After a mean follow-up of 19 months, none of the patients had evidence of biochemical failure or clinical failure. There were no long-term genitourinary side effects detected. Two patients had Common Terminology Criteria for Adverse Events version 4.0 grade II gastrointestinal side effects, of which symptoms resolved to baseline in 1 patient, whereas the other patient progressed to chronic active enteritis (pouchitis). CONCLUSION: Low- to intermediate-risk prostate cancer patients with J-pouch anastomosis after total colectomy for inflammatory bowel disease are candidates for definitive treatment with PPB. Caution should be exercised while deploying the most posterior row of seeds to minimize enteral pouch radiation doses.


Assuntos
Braquiterapia/métodos , Colectomia/métodos , Colite Ulcerativa/terapia , Iodo/uso terapêutico , Neoplasias da Próstata/complicações , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/radioterapia
4.
Brachytherapy ; 12(4): 382-6, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23664645

RESUMO

PURPOSE: To apply failure modes and effects analysis to high-dose-rate treatment planning to identify the most likely and significant sources of error in the process. METHODS: We have made a list of 25 failure modes grouped into six categories (imaging, catheter reconstruction, dwell position activity, dose points/normalization, optimization/dose, and evaluation). Each mode was rated on a one to five scale for severity, likelihood of occurrence, and probability of escaping detection. An overall ranking was formed from the product of the three scores. The authors assigned scores independently and the resulting rankings were averaged. We also analyzed 44 reported medical events related to high-dose-rate treatment planning listed on the Nuclear Regulatory Commission Web site and compared them with our own rankings. RESULTS: Failure modes associated with image sets, catheter reconstruction, indexer length, and incorrect dose points had the highest ranking in our analysis (scores higher than 20). The most often cited failure modes in the Nuclear Regulatory Commission reports examined were indexer length (20/44) and incorrect dose points (6/44). Several of our high-ranking modes are not associated with reported events. CONCLUSION: It is a useful exercise to identify failure modes locally and analyze the efficacy of the local quality assurance program. Comparison with nationally reported failures can help direct the local analysis, but the absence or small number of reports for failure modes with a high score may be owing to low detectability. Such modes obviously cannot be ignored.


Assuntos
Braquiterapia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Catéteres , Humanos , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA