1.
Neurosurgery ; 66(2): 274-83, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20087126

RESUMO

OBJECTIVE: Medically refractory epilepsy is amenable to neurosurgical intervention if the epileptogenic focus is accurately localized. If the scalp video-electroencephalography (EEG) and magnetic resonance imaging are nonlateralizing, yet a single focus is suspected, video-EEG monitoring with bilateral intracranial electrode placement is helpful to lateralize the ictal onset zone. We describe the indications, risks, and utility of such bilateral surveys at our institution. METHODS: We retrospectively reviewed 26 patients with medically refractory seizures who were treated over a 5-year period and underwent bilateral placement of intracranial electrodes. Subdural strips were used in all cases, and additional stereotactic implantation of depth electrodes into mesial temporal lobes occurred in 50%. The mean patient age was 37.7 years, and 65.4% of patients were male. RESULTS: The most common indication for bilateral invasive monitoring was bilateral ictal onsets on surface video-EEG (76.9%), followed by frequent interictal spikes contralateral to a single ictal focus (7.7%). Intracranial monitoring lasted an average of 8.2 days, with ictal events recorded in all cases. Ten patients (38.5%) subsequently underwent more extensive unilateral monitoring via implantation of subdural and depth electrodes through a craniotomy. A therapeutic procedure was performed in 17 patients (65.4%), whereas 1 patient underwent a palliative corpus callosotomy (3.8%). Nine patients underwent a resection without unilateral invasive mapping. Reasons for no therapeutic surgery (n = 8) included multifocal onsets, failing the Wada test, refusal of further treatment, and negative intraoperative electrocorticogram. There was 1 surgical complication, involving a retained electrode fragment that was removed in a separate minor procedure. Of the 26 patients, 15 (57.7%) are now seizure-free or have seizure disorders that have substantially improved (modified Engel classes I and II). Of the 17 patients who underwent a potentially curative surgery, 13 (76.5%) were Engel classes I and II. CONCLUSION: Bilateral placement of subdural strip and depth electrodes for epilepsy monitoring in patients with nonlateralizing scalp EEG and/or discordant imaging studies but clinical suspicion for focal seizure origin is both safe and effective. Given the safety and efficacy of this procedure, epileptologists should have a low threshold to consider bilateral implants for suitable patients.


Assuntos
Estimulação Encefálica Profunda/métodos , Eletrodos Implantados , Epilepsia/terapia , Lateralidade Funcional/fisiologia , Adulto , Craniotomia/métodos , Eletroencefalografia/métodos , Epilepsia/fisiopatologia , Feminino , Humanos , Estudos Longitudinais , Imageamento por Ressonância Magnética , Masculino , Monitorização Fisiológica , Psicocirurgia , Estudos Retrospectivos , Lobo Temporal/fisiologia , Tomógrafos Computadorizados , Resultado do Tratamento , Gravação de Videoteipe
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA