1.
Hum Exp Toxicol ; 38(1): 11-24, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29766753

RESUMO

Little is known on the toxicity of nanomaterials in the user phase. Inclusion of nanomaterials in paints is a common nanotechnology application. This study focuses on the toxicity of dusts from sanding of paints containing nanomaterials. We compared the toxicity of titanium dioxide nanomaterials (TiO2NMs) and dusts generated by sanding boards coated with paints with different amounts of two different types of uncoated TiO2NMs (diameters:10.5 nm and 38 nm). Mice were intratracheally instilled with a single dose of 18, 54 and 162 µg of TiO2NMs or 54, 162 and 486 µg of sanding dusts. At 1, 3 and 28 days post-instillation, we evaluated pulmonary inflammation, liver histology and DNA damage in lung and liver. Pulmonary exposure to both pristine TiO2NMs and sanding dusts with different types of TiO2NMs resulted in dose-dependently increased influx of neutrophils into the lung lumen. There was no difference between the sanding dusts from the two paints. For all exposures but not in vehicle controls, mild histological lesions were observed in the liver. Pulmonary exposure to pristine TiO2NMs and paint dusts with TiO2NMs caused similar type of histological lesions in the liver.


Assuntos
Poeira , Nanoestruturas/toxicidade , Pintura , Titânio/toxicidade , Animais , Líquido da Lavagem Broncoalveolar/citologia , Contagem de Células , Ensaio Cometa , Dano ao DNA , Feminino , Fígado/efeitos dos fármacos , Fígado/patologia , Pulmão/efeitos dos fármacos , Pulmão/imunologia , Camundongos Endogâmicos C57BL , Neutrófilos/efeitos dos fármacos , Neutrófilos/imunologia
2.
Regul Toxicol Pharmacol ; 94: 252-270, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29444452

RESUMO

The typical insulation rock, slag and glass wool fibers are high volume materials. Current exposure levels in industry (generally ≤ 1 fiber/cm3 with a median diameter ∼1 µm and length ≥10 µm) are not considered carcinogenic or causing other types of severe lung effects. However, epidemiological studies are not informative on effects in humans at fiber levels >1 fiber/cm3. Effects may be inferred from valid rat studies, conducted with rat respirable fibers (diameter ≤ 1.5 µm). Therefore, we estimate delivery and deposition in human and rat airways of the industrial fibers. The deposition fractions in humans head regions by nasal (∼0.20) and by mouth breathing (≤0.08) are lower than in rats (0.50). The delivered dose into the lungs per unit lung surface area during a 1-day exposure at a similar air concentration is estimated to be about two times higher in humans than in rats. The deposition fractions in human lungs by nasal (∼0.20) and by mouth breathing (∼0.40) are higher than in rats (∼0.04). The human lung deposition may be up to three times by nasal breathing and up to six times higher by oral breathing than in rats, qualifying assessment factor setting for deposition.


Assuntos
Poluentes Ocupacionais do Ar/farmacocinética , Vidro , Fibras Minerais , Sistema Respiratório/metabolismo , Animais , Simulação por Computador , Humanos , Masculino , Modelos Biológicos , Exposição Ocupacional , Ratos
3.
J Appl Microbiol ; 124(4): 990-1000, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28921812

RESUMO

AIMS: The aim of this study was to identify the most efficient sampling method for quantitative PCR-based detection of airborne human norovirus (NoV). METHODS AND RESULTS: A comparative experiment was conducted in an aerosol chamber using aerosolized murine norovirus (MNV) as a surrogate for NoV. Sampling was performed using a nylon (NY) filter in conjunction with four kinds of personal samplers: Gesamtstaubprobenahme sampler (GSP), Triplex-cyclone sampler (TC), 3-piece closed-faced Millipore cassette (3P) and a 2-stage NIOSH cyclone sampler (NIO). In addition, sampling was performed using the GSP sampler with four different filter types: NY, polycarbonate (PC), polytetrafluoroethylene (PTFE) and gelatine (GEL). The sampling efficiency of MNV was significantly influenced by both sampler and filter type. The GSP sampler was found to give significantly (P < 0·05) higher recovery of aerosolized MNV than 3P and NIO. A higher recovery was also found for GSP compared with TC, albeit not significantly. Finally, recovery of aerosolized MNV was significantly (P < 0·05) higher using NY than PC, PTFE and GEL filters. CONCLUSIONS: The GSP sampler combined with a nylon filter was found to be the best method for personal filter-based sampling of airborne NoV. SIGNIFICANCE AND IMPACT OF THE STUDY: The identification of a suitable NoV air sampler is an important step towards studying the association between exposure to airborne NoV and infection.


Assuntos
Aerossóis/análise , Microbiologia do Ar , Monitoramento Ambiental/métodos , Norovirus/isolamento & purificação , Monitoramento Ambiental/instrumentação , Humanos , Norovirus/classificação , Norovirus/genética
4.
Environ Sci Process Impacts ; 17(1): 62-73, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25407261

RESUMO

A Near Field/Far Field (NF/FF) model is a well-accepted tool for precautionary exposure assessment but its capability to estimate particulate matter (PM) concentrations is not well studied. The main concern is related to emission source characterization which is not as well defined for PM emitters compared to e.g. for solvents. One way to characterize PM emission source strength is by using the material dustiness index which is scaled to correspond to industrial use by using modifying factors, such as handling energy factors. In this study we investigate how well the NF/FF model predicts PM concentration levels in a paint factory. PM concentration levels were measured during big bag and small bag powder pouring. Rotating drum dustiness indices were determined for the specific powders used and applied in the NF/FF model to predict mass concentrations. Modeled process specific concentration levels were adjusted to be similar to the measured concentration levels by adjusting the handling energy factor. The handling energy factors were found to vary considerably depending on the material and process even-though they have the same values as modifying factors in the exposure models. This suggests that the PM source characteristics and process-specific handling energies should be studied in more detail to improve the model-based exposure assessment.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar/estatística & dados numéricos , Monitoramento Ambiental , Resíduos Industriais/análise , Modelos Químicos , Material Particulado/análise , Pintura
5.
Environ Int ; 68: 209-18, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24769411

RESUMO

Emissions of volatile organic compounds and ultrafine particles from a kitchen cleaning agent (cream) and plug-in air freshener were investigated in a 20 m(3) walk-in climate chamber at low (~5 ppb) and high ozone (~50 ppb) test concentrations and 0.6 air exchange rate. The products emitted terpenes, inter alia limonene, dihydromyrcenol, geraniol, linalool, and glycol ethers. The ozone-initiated reaction products of these compounds were measured by air sampling on Tenax TA followed by thermal desorption GC-MS and air sampling on DNPH cartridges followed by liquid extraction and HPLC-UV analysis. Particle formation was monitored simultaneously. A number of oxygenated and poly-oxygenated reaction products were identified and risk assessed for acute airway effects: formaldehyde, acetaldehyde, acetone, 4-acetyl-1-methylcyclohexene, 6-methyl-5-heptene-2-one, 3-isopropenyl-6-oxo-heptanal, and 4-oxo-pentanal. These compounds generally increased initially at the high ozone concentration, while the terpenes decayed, concurrent with their consumption of ozone. At high ozone concentration, the plug-in air freshener resulted in concentrations of formaldehyde and 4-oxopentanal that may give rise to concern about sensory irritation and airflow limitation, respectively. At high ozone concentration, the kitchen cleaning agent and air freshener resulted in peak particle mass concentrations at 81 µg/m(3) (8.5×10(5) #/cm(3)) and 24 µg/m(3) (2.3×10(4) #/cm(3)), respectively. At low ozone concentration, the particle concentration peaked at 4 µg/m(3) (1.0×10(5) #/cm(3)) after the application of the kitchen cleaning agent, while no increase was observed for the air freshener. The particles, in view of their organic composition and concentration, are not considered to cause acute airway effects. Testing under realistic conditions that mimic user pattern behavior is warranted to obtain acute and longer-term exposure data at realistic indoor ozone concentrations.


Assuntos
Poluentes Atmosféricos/análise , Detergentes/química , Ozônio/química , Material Particulado/análise , Doenças Respiratórias/induzido quimicamente , Compostos Orgânicos Voláteis/análise , Adsorção , Poluentes Atmosféricos/química , Poluentes Atmosféricos/isolamento & purificação , Cromatografia Líquida de Alta Pressão , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Material Particulado/química , Medição de Risco , Espectrofotometria Ultravioleta , Compostos Orgânicos Voláteis/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA