Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
BMC Infect Dis ; 24(1): 845, 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39169302

RESUMO

In 2023, passive laboratory-based surveillance showed an increase in hepatitis A virus (HAV) infection. We investigated hepatitis A incidence using the notifiable medical condition surveillance system (NMCSS) data and molecularly characterised positive blood samples from the Western Cape province for 2023. All HAV IgM seropositive cases from the NMCSS from 1 January to 31 October 2023 in South Africa were investigated. HAV RNA from blood samples that had tested positive for HAV IgM from Western Cape was amplified in the VP1/P2B junction and sequenced (3500Xl Genetic Analyser). Sequences were assembled, aligned (Sequencher) and analysed (Aliview 1.27 and MEGA11). Statistical analysis was performed using Excel and the CuSum2 Threshold to determine suspected outbreaks. In 2023, the incidence of HAV IgM was 6.28/100,000 in South Africa, with the highest incidence in Western Cape province (15.86/100,000). Children aged 5 to 14 years were affected the most in the Western Cape. The positive cases in the Western Cape were above the CuSum2 threshold from January to May 2023, with the highest incidence observed in the City of Cape Town Metropolitan (14.8/100,000). Genotyping was successfully performed on 92.7% (139/150) of serum samples, for which the IB sub-genotype was detected. Three primary mutations R63K, R71S and M104I were observed in more than 49% of the samples. Most of the samples sequenced belonged to patients residing in areas close to each other within the City of Cape Town Southern, Western, and Mitchells Plain sub-districts. The CuSum2 threshold method allowed the identification of suspected HAV outbreaks in the districts within the Western Cape in 2023 while genotyping identified clusters of sub-genotype IB. Genotyping could assist with determining the common source of infection during an outbreak, especially if coupled with epidemiological and geographical data. Further active surveillance can assist in investigating the HAV risk factors for targeted public health responses.


Assuntos
Hepatite A , Filogenia , RNA Viral , Humanos , África do Sul/epidemiologia , Hepatite A/epidemiologia , Hepatite A/virologia , Pré-Escolar , Criança , Adolescente , Masculino , Adulto , Feminino , Adulto Jovem , Pessoa de Meia-Idade , Incidência , Lactente , RNA Viral/genética , Genótipo , Imunoglobulina M/sangue , Vírus da Hepatite A/genética , Vírus da Hepatite A/classificação , Vírus da Hepatite A/isolamento & purificação , Idoso , Surtos de Doenças , Anticorpos Anti-Hepatite A/sangue
2.
Afr J Lab Med ; 13(1): 2364, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38840959

RESUMO

Background: Understanding factors that impact HIV viral load (VL) accuracy in resource-limited settings is key to quality improvement. Objective: We evaluated whether testing delay and specimen storage between 25 °C and 30 °C before testing affected results. Methods: Between November 2019 and June 2023, 249 individuals on antiretroviral therapy, or with newly diagnosed HIV, were recruited from clinics in Cape Town and Gqeberha, South Africa, and three plasma preparation tubes were collected. One tube was tested within 24 h, while the others were stored uncentrifuged at ambient temperatures before testing. Centrifugation and testing of matched samples were performed on Day 4 and Day 7 after collection. Results: Time delay and ambient storage had minimal impact in specimens with a Day 1 VL of > 100 copies/mL. When grouped by Day 1 VL range, 96% - 100% of specimens at Day 4 and 93% - 100% at Day 7 had VLs within 0.5 log copies/mL of the first result. The greatest variability at Days 4 and 7 was observed when the Day 1 VL was < 100 copies/mL. However, there was no trend of increasing difference over time. Of Day 1 specimens with undetectable VL, or VL < 50 copies/mL, 80% had concordant results at Day 4 and 78% at Day 7. Conclusion: These results show that VL is stable in plasma preparation tubes for 7 days when stored at room temperature. There is significant variability in specimens with low VL, but variability is not affected by testing delay. What this study adds: Ideal HIV VL testing conditions are frequently unachievable in resource-limited settings. Data are needed on whether this impacts on the validity of test results. Our results provide reassurance that storage at ambient temperature for up to 7 days before testing does not substantially affect the VL result.

3.
Diagnostics (Basel) ; 13(15)2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37568938

RESUMO

The epidemiology of human parainfluenza viruses (HPIV), particularly its role as a cause of acute respiratory infection (ARI) in infants, has not been formally studied in South Africa. We evaluated HPIV prevalence in diagnostic samples from hospitalized children from public sector hospitals in the Western Cape between 2014 and 2022. HPIV infection was detected in 2-10% of patients, with the majority of infections detected in children less than 1 year of age. Prior to 2020, HPIV 4 (40%) and HPIV 3 (34%) were the most prevalent types, with seasonal peaks in late winter/spring for HPIV 3 and autumn/winter for HPIV 4. HPIV 4A and 4B co-circulated during the seasonal activity between 2014 and 2017. Pandemic restrictions in 2020 had a profound effect on HPIV circulation and the rebound was dominated by waves of HPIV 3, accounting for 66% of detections and a sustained decline in the circulation of HPIV 1, 2 and 4. An immunity gap could account for the surge in HPIV 3 infections, but the decline in prior HPIV 4 dominance is unexplained and requires further study.

4.
Int J Infect Dis ; 118: 150-154, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35235826

RESUMO

BACKGROUND: At present, it is unclear whether the extent of reduced risk of severe disease seen with SARS-Cov-2 Omicron variant infection is caused by a decrease in variant virulence or by higher levels of population immunity. METHODS: RdRp target delay (RTD) in the Seegene AllplexTM 2019-nCoV PCR assay is a proxy marker for the Delta variant. The absence of this proxy marker in the transition period was used to identify suspected Omicron infections. Cox regression was performed for the outcome of hospital admission in those who tested positive for SARS-CoV-2 on the Seegene AllplexTM assay from November 1 to December 14, 2021 in the Western Cape Province, South Africa, in the public sector. Adjustments were made for vaccination status and prior diagnosis of infection. RESULTS: A total of 150 cases with RTD and 1486 cases without RTD were included. Cases without RTD had a lower hazard of admission (adjusted hazard ratio [aHR], 0.56; 95% confidence interval [CI], 0.34-0.91). Complete vaccination was protective against admission, with an aHR of 0.45 (95% CI, 0.26-0.77). CONCLUSION: Omicron has resulted in a lower risk of hospital admission compared with contemporaneous Delta infection, when using the proxy marker of RTD. Under-ascertainment of reinfections with an immune escape variant remains a challenge to accurately assessing variant virulence.


Assuntos
COVID-19 , Hepatite D , COVID-19/diagnóstico , Humanos , Reação em Cadeia da Polimerase , RNA Polimerase Dependente de RNA , SARS-CoV-2/genética , África do Sul/epidemiologia , Análise de Sobrevida
5.
BMC Infect Dis ; 22(1): 45, 2022 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-35016628

RESUMO

BACKGROUND: While some evidence has been demonstrated the cost-effectiveness of routine hepatitis A vaccination in middle-income countries, the evidence is still limited in other settings including in South Africa. Given this, the evidence base around the cost of care for hepatitis A needs to be developed towards considerations of introducing hepatitis A vaccines in the national immunisation schedule and guidelines. OBJECTIVES: To describe the severity, clinical outcomes, and cost of hepatitis A cases presenting to two tertiary healthcare centers in Cape Town, South Africa. METHODS: We conducted a retrospective folder review of patients presenting with hepatitis A at two tertiary level hospitals providing care for urban communities of metropolitan Cape Town, South Africa. Patients included in this folder review tested positive for hepatitis A immunoglobulin M between 1 January 2008 and 1 March 2018. RESULTS: In total, 239 folders of hepatitis A paediatric patients < 15 years old and 212 folders of hepatitis A adult patients [Formula: see text] 15 years old were included in the study. Before presenting for tertiary level care, more than half of patients presented for an initial consultation at either a community clinic or general physician. The mean length of hospital stay was 7.45 days for adult patients and 3.11 days for paediatric patients. Three adult patients in the study population died as a result of hepatitis A infection and 29 developed complicated hepatitis A. One paediatric patient in the study population died as a result of hepatitis A infection and 27 developed complicated hepatitis A, including 4 paediatric patients diagnosed with acute liver failure. The total cost per hepatitis A hospitalisation was $1935.41 for adult patients and $563.06 for paediatric patients, with overhead costs dictated by the length of stay being the largest cost driver. CONCLUSION: More than 1 in every 10 hepatitis A cases (13.3%) included in this study developed complicated hepatitis A or resulted in death. Given the severity of clinical outcomes and high costs associated with hepatitis A hospitalisation, it is important to consider the introduction of hepatitis A immunisation in the public sector in South Africa to potentially avert future morbidity, mortality, and healthcare spending.


Assuntos
Hepatite A , Adolescente , Adulto , Criança , Análise Custo-Benefício , Hepatite A/epidemiologia , Humanos , Estudos Retrospectivos , África do Sul/epidemiologia , Vacinação
6.
J Virol Methods ; 302: 114471, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35051442

RESUMO

Routine SARS-CoV-2 surveillance in the Western Cape region of South Africa (January-August 2021) found a reduced RT-PCR amplification efficiency of the RdRp-gene target of the Seegene, Allplex 2019-nCoV diagnostic assay from June 2021 when detecting the Delta variant. We investigated whether the reduced amplification efficiency denoted by an increased RT-PCR cycle threshold value (RΔE) can be used as an indirect measure of SARS-CoV-2 Delta variant prevalence. We found a significant increase in the median RΔE for patient samples tested from June 2021, which coincided with the emergence of the SARS-CoV-2 Delta variant within our sample set. Whole genome sequencing on a subset of patient samples identified a highly conserved G15451A, non-synonymous mutation exclusively within the RdRp gene of Delta variants, which may cause reduced RT-PCR amplification efficiency. While whole genome sequencing plays an important in identifying novel SARS-CoV-2 variants, monitoring RΔE value can serve as a useful surrogate for rapid tracking of Delta variant prevalence.


Assuntos
Teste de Ácido Nucleico para COVID-19 , COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , COVID-19/virologia , Testes Diagnósticos de Rotina , Humanos , RNA , RNA Polimerase Dependente de RNA , SARS-CoV-2/genética
7.
Gates Open Res ; 6: 117, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37994361

RESUMO

Background: The SARS-CoV-2 Delta variant (B.1.617.2) has been associated with more severe disease, particularly when compared to the Alpha variant. Most of this data, however, is from high income countries and less is understood about the variant's disease severity in other settings, particularly in an African context, and when compared to the Beta variant. Methods: A novel proxy marker, RNA-dependent RNA polymerase (RdRp) target delay in the Seegene Allplex TM 2019-nCoV (polymerase chain reaction) PCR assay, was used to identify suspected Delta variant infection in routine laboratory data. All cases diagnosed on this assay in the public sector in the Western Cape, South Africa, from 1 April to 31 July 2021, were included in the dataset provided by the Western Cape Provincial Health Data Centre (PHDC). The PHDC collates information on all COVID-19 related laboratory tests, hospital admissions and deaths for the province. Odds ratios for the association between the proxy marker and death were calculated, adjusted for prior diagnosed infection and vaccination status. Results: A total of 11,355 cases with 700 deaths were included in this study. RdRp target delay (suspected Delta variant) was associated with higher mortality (adjusted odds ratio [aOR] 1.45; 95% confidence interval [CI]: 1.13-1.86), compared to presumptive Beta infection. Prior diagnosed infection during the previous COVID-19 wave, which was driven by the Beta variant, was protective (aOR 0.32; 95%CI: 0.11-0.92) as was vaccination (aOR [95%CI] 0.15 [0.03-0.62] for complete vaccination [≥28 days post a single dose of Ad26.COV2.S or ≥14 days post second BNT162b2 dose]). Conclusion: RdRp target delay, a proxy for infection with the Delta variant, is associated with an increased risk of mortality amongst those who were tested for COVID-19 in our setting.

8.
J Clin Virol ; 139: 104845, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33962182

RESUMO

BACKGROUND: Enteroviruses are amongst the most common causes of aseptic meningitis. Between November 2018 and May 2019, an outbreak of enterovirus-associated aseptic meningitis cases was noted in the Western and Eastern Cape Provinces, South Africa. OBJECTIVES: To describe the epidemiology and phylogeography of enterovirus infections during an aseptic meningitis outbreak in the Western and Eastern Cape Provinces of South Africa. METHODS: Cerebrospinal fluid samples from suspected cases were screened using a polymerase chain reaction targeting the 5'UTR. Confirmed enterovirus-associated meningitis samples underwent molecular typing through species-specific VP1/VP2 primers and pan-species VP1 primers. RESULTS: Between November 2018 and May 2019, 3497 suspected cases of aseptic meningitis were documented in the Western and Eastern Cape Provinces. Median age was 8 years (range 0-61), interquartile range (IQR=4-13 years), 405/735 (55%) male. 742/3497 (21%) cases were laboratory - confirmed enterovirus positive by routine diagnostic PCR targeting the 5'UTR. 128/742 (17%) underwent molecular typing by VP1 gene sequencing. Echovirus 4 (E4) was detected in 102/128 (80%) cases. Echovirus 9 was found in 7%, Coxsackievirus A13 in 3%. 10 genotypes contributed to the remaining 10% of cases. Synonymous mutations were found in most cases, with sporadic amino acid changes in 13 (12.7%) cases. CONCLUSION: The aseptic meningitis outbreak was associated with echovirus 4. Stool samples are valuable for molecular typing in CSF confirmed EV-associated aseptic meningitis.


Assuntos
Infecções por Enterovirus , Enterovirus , Meningite Asséptica , Adolescente , Adulto , Criança , Pré-Escolar , Surtos de Doenças , Enterovirus/genética , Enterovirus Humano B/genética , Infecções por Enterovirus/epidemiologia , Humanos , Lactente , Recém-Nascido , Masculino , Meningite Asséptica/epidemiologia , Pessoa de Meia-Idade , Filogenia , RNA Viral/genética , África do Sul/epidemiologia , Adulto Jovem
9.
Nature ; 592(7854): 438-443, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33690265

RESUMO

Continued uncontrolled transmission of SARS-CoV-2 in many parts of the world is creating conditions for substantial evolutionary changes to the virus1,2. Here we describe a newly arisen lineage of SARS-CoV-2 (designated 501Y.V2; also known as B.1.351 or 20H) that is defined by eight mutations in the spike protein, including three substitutions (K417N, E484K and N501Y) at residues in its receptor-binding domain that may have functional importance3-5. This lineage was identified in South Africa after the first wave of the epidemic in a severely affected metropolitan area (Nelson Mandela Bay) that is located on the coast of the Eastern Cape province. This lineage spread rapidly, and became dominant in Eastern Cape, Western Cape and KwaZulu-Natal provinces within weeks. Although the full import of the mutations is yet to be determined, the genomic data-which show rapid expansion and displacement of other lineages in several regions-suggest that this lineage is associated with a selection advantage that most plausibly results from increased transmissibility or immune escape6-8.


Assuntos
COVID-19/virologia , Mutação , Filogenia , Filogeografia , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , COVID-19/epidemiologia , COVID-19/imunologia , COVID-19/transmissão , Análise Mutacional de DNA , Evolução Molecular , Aptidão Genética , Humanos , Evasão da Resposta Imune , Modelos Moleculares , SARS-CoV-2/imunologia , SARS-CoV-2/patogenicidade , Seleção Genética , África do Sul/epidemiologia , Glicoproteína da Espícula de Coronavírus/química , Glicoproteína da Espícula de Coronavírus/genética , Glicoproteína da Espícula de Coronavírus/metabolismo , Fatores de Tempo
10.
PLoS One ; 16(1): e0245189, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33428663

RESUMO

Automated testing of HIV serology on clinical chemistry analysers has become common. High sample throughput, high HIV prevalence and instrument design could all contribute to sample cross-contamination by microscopic droplet carry-over from seropositive samples to seronegative samples resulting in false positive low-reactive results. Following installation of an automated shared platform at our public health laboratory, we noted an increase in low reactive and false positive results. Subsequently, we investigated HIV serology screening test results for a period of 21 months. Of 485 initially low positive or equivocal samples 411 (85%) tested negative when retested using an independently collected sample. As creatinine is commonly requested with HIV screening, we used it as a proxy for concomitant clinical chemistry testing, indicating that a sample had likely been tested on a shared high-throughput instrument. The contamination risk was stratified between samples passing the clinical chemistry module first versus samples bypassing it. The odds ratio for a false positive HIV serology result was 4.1 (95% CI: 1.69-9.97) when creatinine level was determined first, versus not, on the same sample, suggesting contamination on the chemistry analyser. We subsequently issued a notice to obtain dedicated samples for HIV serology and added a suffix to the specimen identifier which restricted testing to a dedicated instrument. Low positive and false positive rates were determined before and after these interventions. Based on measured rates in low positive samples we estimate that before the intervention, of 44 117 HIV screening serology samples, 753 (1.71%) were false positive, declining to 48 of 7 072 samples (0.68%) post-intervention (p<0.01). Our findings showed that automated high throughput shared diagnostic platforms are at risk of generating false-positive HIV test results, due to sample contamination and that measures are required to address this. Restricting HIV serology samples to a dedicated platform resolved this problem.


Assuntos
Sorodiagnóstico da AIDS , Infecções por HIV , HIV-1 , Programas de Rastreamento , Reações Falso-Positivas , Feminino , Infecções por HIV/sangue , Infecções por HIV/diagnóstico , Infecções por HIV/epidemiologia , Humanos , Masculino , Prevalência
11.
IDCases ; 21: e00849, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32514397

RESUMO

The consequences of falsely reactive HIV test results can be significant, for patients and healthcare providers. This case describes a diagnostic investigation of a patient with pronounced discordant HIV serological results, to determine HIV status. The fourth generation serological screening assay (Roche COBAS Elecsys HIV combiPT) had high positive results but confirmatory testing was negative (Abbott HIV Ag/Ab Combo). Five separate samples over 13 days were tested using multiple fourth generation HIV immunoassays and molecular tests for HIV-1 and HIV-2. Potential causes of falsely reactive serological results were investigated. Samples were sent to the manufacturer for analysis. The screening assay was positive on all samples with a very high signal to cut-off ratio (S/CO) of greater than 400. However, multiple serological and molecular assays did not detect HIV-1 or HIV-2 specific antibodies, antigen or nucleic acid. A recombinant immunochromatographic assay had faint reactivity to gp41 peptide and the manufacturer investigation reported cross-reactivity to one of the screening assay's synthetic peptides. Possible causes of the false positive result include cross reactivity to other antigens, including prior schistosomiasis infection, or the patient's previously excised ameloblastoma (a rare germ cell tumor of the jaw). This is a rare case of false high positive results on fourth-generation HIV serology testing due to high level non-specific reactivity to an isolated synthetic peptide component of the assay. It highlights the need for confirmatory testing even in settings with HIV high prevalence and awareness that false-positive serological results may have a high S/CO.

12.
PLoS One ; 14(7): e0219381, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31269089

RESUMO

BACKGROUND: Viral load testing is key to monitoring response to anti-retroviral therapy (ART). However, in lower and middle income countries with large epidemics, pre-analytical challenges threaten the quality of testing. It is unknown how much delayed processing and adverse storage affects the validity of results. The aim of this study was to determine the impact of delayed testing and warmer storage conditions on HIV RNA stability in diagnostic samples. METHODS: 1194 samples, collected in EDTA or plasma preparation (PPT) tubes, were studied. Immediately after initial testing, primary tubes were stored for 72, 96 or 168 hours at 4°C, 20°C or 30°C. The viral load was then repeated and the 2 results were compared. RESULTS: Viral loads were very stable, with <0.5 log copies/ml median difference noted between paired tests for all storage times and temperatures. The viral load in samples stored for up to a week reliably differentiated between ART-suppressed and failing patients in 98.83% of instances. However, re-centrifugation immediately prior to repeat testing was essential to avoid falsely elevated readings, probably due to contamination of plasma with cell-associated viral nucleic acids. Approximately 20% of samples with initially undetectable viral loads were weakly positive (<100 copies/mL) on repeat. This was not exacerbated by duration or temperature of storage. CONCLUSION: Viral RNA in diagnostic samples is stable well beyond currently recommended limits. However, when testing stored primary samples, contamination of plasma with cellular material easily occurs. Low viral loads (<100copies/mL) in samples stored in this way should be interpreted with caution.


Assuntos
Testes Diagnósticos de Rotina , Infecções por HIV/sangue , Infecções por HIV/virologia , Carga Viral , Centrifugação , RNA Viral/genética , Reprodutibilidade dos Testes , Temperatura , Fatores de Tempo
13.
BMC Infect Dis ; 18(1): 709, 2018 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-30594238

RESUMO

BACKGROUND: Human enteroviruses (HEVs) are common causal agents of aseptic meningitis in young children. Laboratory and syndromic surveillance during December 2015 and January 2016 noted an unusually high number of paediatric aseptic meningitis cases at a hospital in Mossel Bay, Western Cape Province, South Africa. HEV was detected in clinical samples, prompting an outbreak investigation. METHODS: Epidemiological investigations were conducted to ascertain possible linkage between cases. Amplification, sequencing and phylogenetic analysis of the 5'UTR and VP1 regions was undertaken to determine the HEV serotype associated with the outbreak as well as other cases of aseptic meningitis in the area in the preceding 6 weeks. RESULTS: Over the 2-month period, 63 CSF samples were available for testing. A total of 43 outbreak cases (68.3%) were observed, and the 26 (60.5%) that could be typed were coxsackie virus A9 (CVA9). Children attending three crèche facilities were epidemiologically linked, accounting for 60.5% (26/43) of the CVA9 cases. The majority of patients were under 10 years of age (55/63, 87.3%) and there was a male predominance (66%). Nucleotide sequence analysis of the 5'UTR and VP1 regions identified 2 lineages of CVA9 co-circulating during the outbreak, although the VP1 capsid protein sequence was identical as all nucleotide differences were synonymous. There was a unique isoleucine at position 64 and all outbreak viruses had a valine to threonine change in the hypervariable BC loop of VP1. Other HEV types circulating in the preceding period were echovirus 30 (n = 4), echovirus 5 (n = 3) and 1 each of echovirus 6, echovirus 9 and echovirus 15. CONCLUSION: CVA9 was identified as the pathogen responsible for the large outbreak of aseptic meningitis, with 2 distinct co-circulating lineages.


Assuntos
Surtos de Doenças , Infecções por Enterovirus/epidemiologia , Enterovirus/genética , Enterovirus/isolamento & purificação , Meningite Viral/epidemiologia , Adolescente , Adulto , Criança , Pré-Escolar , Enterovirus/classificação , Enterovirus Humano B/genética , Infecções por Enterovirus/complicações , Infecções por Enterovirus/virologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Meningite Viral/virologia , Tipagem Molecular , Filogenia , RNA Viral/análise , Vigilância de Evento Sentinela , África do Sul/epidemiologia , Adulto Jovem
14.
PLoS One ; 12(7): e0182167, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28759622

RESUMO

INTRODUCTION: In South Africa where the prevalence of HIV infection is very high, 4th generation HIV antibody/p24 antigen combo immunoassays are the tests of choice for laboratory based screening. Testing is usually performed in clinical pathology laboratories on automated analysers. To investigate the cause of false positive results on 4th generation HIV testing platforms in public sector laboratories, the performance of two automated platforms was compared in a clinical pathology setting, firstly on routine diagnostic specimens and secondly on known sero-negative samples. METHODS: Firstly, 1181 routine diagnostic specimens were sequentially tested on Siemens and Roche automated 4th generation platforms. HIV viral load, western blot and follow up testing were used to determine the true status of inconclusive specimens. Subsequently, known HIV seronegative samples from a single donor were repeatedly tested on both platforms and an analyser was tested for surface contamination with HIV positive serum to identify how suspected specimen contamination could be occurring. RESULTS: Serial testing of diagnostic specimens yielded 163 weakly positive or discordant results. Only 3 of 163 were conclusively shown to indicate true HIV infection. Specimen contamination with HIV antibody was suspected, based on the following evidence: the proportion of positive specimens increased on repeated passage through the analysers; viral loads were low or undetectable and western blots negative or indeterminate on problem specimens; screen negative, 2nd test positive specimens tested positive when reanalysed on the screening assay; follow up specimens (where available) were negative. Similarly, an increasing number of known negative specimens became (repeatedly) sero-positive on serial passage through one of the analysers. Internal and external analyser surfaces were contaminated with HIV serum, evidence that sample splashes occur during testing. CONCLUSIONS: Due to the extreme sensitivity of these assays, contamination with minute amounts of HIV antibody can cause a negative sample to test positive. Better contamination control measures are needed on analysers used in clinical pathology environments, especially in regions where HIV sero-prevalence is high.


Assuntos
Sorodiagnóstico da AIDS/normas , Automação Laboratorial/normas , Contaminação de Equipamentos , Infecções por HIV/sangue , Sorodiagnóstico da AIDS/instrumentação , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Automação Laboratorial/instrumentação , Reações Falso-Positivas , HIV/imunologia , Infecções por HIV/epidemiologia , Humanos , Prevalência , África do Sul
15.
World J Gastroenterol ; 22(44): 9853-9859, 2016 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-27956810

RESUMO

AIM: To conduct a prospective assessment of anti-hepatitis E virus (HEV) IgG seroprevalence in the Western Cape Province of South Africa in conjunction with evaluating risk factors for exposure. METHODS: Consenting participants attending clinics and wards of Groote Schuur, Red Cross Children's Hospital and their affiliated teaching hospitals in Cape Town, South Africa, were sampled. Healthy adults attending blood donor clinics were also recruited. Patients with known liver disease were excluded and all major ethnic/race groups were included to broadly represent local demographics. Relevant demographic data was captured at the time of sampling using an interviewer-administered confidential questionnaire. Human immunodeficiency virus (HIV) status was self-disclosed. HEV IgG testing was performed using the Wantai® assay. RESULTS: HEV is endemic in the region with a seroprevalence of 27.9% (n = 324/1161) 95%CI: 25.3%-30.5% (21.9% when age-adjusted) with no significant differences between ethnic groups or HIV status. Seroprevalence in children is low but rapidly increases in early adulthood. With univariate analysis, age ≥ 30 years old, pork and bacon/ham consumption suggested risk. In the multivariate analysis, the highest risk factor for HEV IgG seropositivity (OR = 7.679, 95%CI: 5.38-10.96, P < 0.001) was being 30 years or older followed by pork consumption (OR = 2.052, 95%CI: 1.39-3.03, P < 0.001). A recent clinical case demonstrates that HEV genotype 3 may be currently circulating in the Western Cape. CONCLUSION: Hepatitis E seroprevalence was considerably higher than previously thought suggesting that hepatitis E warrants consideration in any patient presenting with an unexplained hepatitis in the Western Cape, irrespective of travel history, age or ethnicity.


Assuntos
Anticorpos Anti-Hepatite/sangue , Vírus da Hepatite E/imunologia , Hepatite E/epidemiologia , Imunoglobulina G/sangue , Adolescente , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Estudos de Casos e Controles , Criança , Pré-Escolar , Feminino , Hepatite E/sangue , Hepatite E/diagnóstico , Vírus da Hepatite E/patogenicidade , Humanos , Recém-Nascido , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Estudos Soroepidemiológicos , Testes Sorológicos , África do Sul/epidemiologia , Adulto Jovem
17.
J Virol Methods ; 193(1): 166-8, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23792685

RESUMO

CMV is a common cause of disease in immunocompromised patients. Because sampling of the diseased organ can be invasive, markers of systemic CMV reactivation such as pp65 and CMV viral load are commonly used to monitor patients at risk of CMV disease. In this retrospective analysis, the performance of these markers was compared in solid organ transplant recipients, patients with haematological malignancies and HIV infection. Both assays were sensitive markers of reactivation, however, the predictive value for disease of a positive result for both was low. Compared to viral load, the pp65 assay was a less sensitive marker of CMV reactivation. It was only positive when the viral load was greater than 3 log (10) copies/ml whole blood and was negative in 10 instances when the viral load was between 3 and 5 logs. In concordantly positive samples, the number of pp65 positive cells varied widely relative to the viral load and the number of positive cells counted could not be used to predict disease likelihood with any certainty. To conclude, CMV viral load provides a more consistent guide to determine likelihood of disease than pp65 count and is a more sensitive marker of CMV reactivation.


Assuntos
Técnicas de Laboratório Clínico/métodos , Infecções por Citomegalovirus/diagnóstico , Citomegalovirus/isolamento & purificação , Fosfoproteínas/sangue , Carga Viral , Proteínas da Matriz Viral/sangue , Infecções por Citomegalovirus/virologia , Infecções por HIV/complicações , Neoplasias Hematológicas/complicações , Humanos , Transplante de Órgãos/efeitos adversos , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Transplante , Ativação Viral
18.
Recurso na Internet em Inglês | LIS - Localizador de Informação em Saúde | ID: lis-15748

RESUMO

It's a medical textbook that provides a comprehensive overview of epidemic and pandemic influenza. Croatian, German, Indonesian and Mongolian reports are in pdf format; Acrobat Reader needed. Chinese, Serbian and Slovenian versions are also available in html format.


Assuntos
Influenza Humana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA