Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 9(2): e13203, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36747534

RESUMO

Cellulose nanofibers (CNFs) were used to improve the fracture toughness of glass fiber reinforced epoxy composites (GFRPs). Different CNF suspensions were prepared and sprayed onto the surface of woven glass fiber laminates. The vacuum resin transfer molding (VaRTM) process was used to manufacture the GFRP composites. End notch flexure tests were conducted to evaluate the effect of CNFs on the critical energy release rate in mode II fracture toughness GIIC. The results revealed that 0.05 wt% was the optimum concentration. The interlaminar fracture toughness GIIC was improved by 28% with the addition of 0.05 wt% of CNFs to GF/epoxy composites. Whereas 0.1 wt% of CNFs resulted in decreasing GIIC due to the uncomplete impregnation of GF with epoxy resin caused by the thicker CNF layer at the interfacial laminates. The toughening mechanisms were investigated using a field-emission electron microscope. Large epoxy deformations and shear hackles were predominant for improving the interlaminar fracture toughness of GFRP composites.

2.
Appl Opt ; 53(32): 7664-76, 2014 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-25402988

RESUMO

The new Japanese x-ray astronomy satellite, ASTRO-H, will carry two identical hard x-ray telescopes (HXTs), which cover the energy range of 5 to 80 keV. The HXT mirrors employ tightly nested, conically approximated thin-foil Wolter-I optics, and the mirror surfaces are coated with Pt/C depth-graded multilayers to enhance the hard x-ray effective area by means of Bragg reflection. The HXT comprises foils 120-450 mm in diameter and 200 mm in length, with a focal length of 12 m. To obtain a large effective area, 213 aluminum foils 0.2 mm in thickness are tightly nested confocally. The requirements for HXT are a total effective area of >300 cm2 at 30 keV and an angular resolution of <1.7' in half-power diameter (HPD). Fabrication of two HXTs has been completed, and the x-ray performance of each HXT was measured at a synchrotron radiation facility, SPring-8 BL20B2 in Japan. Angular resolutions (HPD) of 1.9' and 1.8' at 30 keV were obtained for the full telescopes of HXT-1 and HXT-2, respectively. The total effective area of the two HXTs at 30 keV is 349 cm2.


Assuntos
Lentes , Astronave/instrumentação , Telescópios , Difração de Raios X/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA