Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Heart Rhythm ; 2024 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-38286245

RESUMO

BACKGROUND: Differentiating between atypical atrioventricular nodal reentrant tachycardia (AVNRT) and orthodromic reciprocating tachycardia utilizing a septal accessory pathway is a complex challenge. OBJECTIVE: The purpose of this study was to describe the "local VA index," a straightforward method based on signals from the coronary sinus catheter, to distinguish between these arrhythmias during tachycardia and entrainment. The ventriculoatrial (VA) interval on the coronary sinus catheter is measured during tachycardia and entrainment, at the site of earliest atrial activity. The difference between these 2 situations defines the "local VA index." We also propose a mechanism to clarify the limitations of historical pacing maneuvers, such as postpacing interval minus tachycardia cycle length (PPI-TCL) and stimulus-atrial interval minus ventriculoatrial interval (SA-VA), by examining nodal decrement and intraventricular conduction delay. METHODS: In a retrospective study of 75 patients referred for supraventricular tachycardia evaluation, 37 were diagnosed with atrioventricular reentrant tachycardia (AVRT) with orthodromic reciprocating tachycardia, and 38 with AVNRT (27 typical, 11 atypical). RESULTS: In comparison to AVRT patients, AVNRT patients exhibited longer PPI-TCL (176 ± 47 ms vs 113 ± 42 ms; P <.01) and SA-VA (138 ± 47 ms vs 64 ± 28 ms; P <.01). The AVRT group had mean local VA index of -1 ± 13 ms, whereas the AVNRT group had a significantly longer index of 91 ± 46 ms (P <.01). An optimal threshold for differentiation was a local VA index of 40 ms. Importantly, there was no significant correlation between pacing cycle length and nodal decrement as well as intraventricular delay related to pathway location. This interindividual variability might explain misleading interpretations of PPI-TCL and SA-VA. CONCLUSION: This novel approach is advantageous because of its simplicity and effectiveness, requiring only 2 diagnostic catheters. A local VA interval difference <40 ms provides a clear distinction for AVRT.

3.
Heart Rhythm ; 20(10): 1370-1377, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37414109

RESUMO

BACKGROUND: Omnipolar technology (OT) was recently proposed to generate electroanatomic voltage maps with orientation-independent electrograms. We describe the first cohort of patients undergoing ventricular tachycardia (VT) ablation guided by OT. OBJECTIVE: The purpose of this study was to compare omnipolar and bipolar high-density maps with regard to voltage amplitude, late potential (LP) annotation, and isochronal late activation mapping distribution. METHODS: A total of 24 patients (16 [66%] ischemic cardiomyopathy and 12 [50%] redo cases) underwent VT ablation under OT guidance. Twenty-seven sinus rhythm substrate maps and 10 VT activation maps were analyzed. Omnipolar and bipolar (HD Wave Solution algorithm, Abbott, Abbott Park, IL) voltages were compared. Areas of LPs were correlated with the VT isthmus areas, and late electrogram misannotation was evaluated. Deceleration zones based on isochronal late activation maps were analyzed by 2 blinded operators and compared to the VT isthmuses. RESULTS: OT maps had higher point density (13.8 points/cm2 vs 8.0 points/cm2). Omnipolar points had 7.1% higher voltages than bipolar points within areas of dense scar and border zone. The number of misannotated points was significantly lower for OT maps (6.8% vs 21.9%; P = .01), showing comparable sensitivity (53% vs 59%) but higher specificity (79% vs 63%). The sensitivity and specificity of detection of the VT isthmus in the deceleration zones were, respectively, 75% and 65% for OT and 35% and 55% for bipolar mapping. At 8.4 months, 71% freedom from VT recurrence was achieved. CONCLUSION: OT is a valuable tool for guiding VT ablation, providing more accurate identification of LPs and isochronal crowding due to slightly higher voltages.

4.
J Cardiovasc Electrophysiol ; 34(6): 1395-1404, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37232426

RESUMO

AIM: Ventricular arrhythmias (VAs) are the most common cause of death in patients with repaired Tetralogy of Fallot (rTOF). However, risk stratifying remains challenging. We examined outcomes following programmed ventricular stimulation (PVS) with or without subsequent ablation in patients with rTOF planned for pulmonary valve replacement (PVR). METHODS: We included all consecutive patients with rTOF referred to our institution from 2010 to 2018 aged ≥18 years for PVR. Right ventricular (RV) voltage maps were acquired and PVS was performed from two different sites at baseline, and if non-inducible under isoproterenol. Catheter and/or surgical ablation was performed when patients were inducible or when slow conduction was present in anatomical isthmuses (AIs). Postablation PVS was undertaken to guide implantable cardioverter-defibrillator (ICD) implantation. RESULTS: Seventy-seven patients (36.2 ± 14.3 years old, 71% male) were included. Eighteen were inducible. In 28 patients (17 inducible, 11 non-inducible but with slow conduction) ablation was performed. Five had catheter ablation, surgical cryoablation in 9, both techniques in 14. ICDs were implanted in five patients. During a follow-up of 74 ± 40 months, no sudden cardiac death occurred. Three patients experienced sustained VAs, all were inducible during the initial EP study. Two of them had an ICD (low ejection fraction for one and important risk factor for arrhythmia for the second). No VAs were reported in the non-inducible group (p < .001). CONCLUSION: Preoperative EPS can help identifying patients with rTOF at risk for VAs, providing an opportunity for targeted ablation and may improve decision-making regarding ICD implantation.


Assuntos
Implante de Prótese de Valva Cardíaca , Valva Pulmonar , Taquicardia Ventricular , Tetralogia de Fallot , Humanos , Masculino , Adolescente , Adulto , Adulto Jovem , Pessoa de Meia-Idade , Feminino , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Tetralogia de Fallot/complicações , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia
6.
Curr Cardiol Rep ; 25(6): 535-542, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37115434

RESUMO

PURPOSE OF REVIEW: Imaging plays a crucial role in the therapy of ventricular tachycardia (VT). We offer an overview of the different methods and provide information on their use in a clinical setting. RECENT FINDINGS: The use of imaging in VT has progressed recently. Intracardiac echography facilitates catheter navigation and the targeting of moving intracardiac structures. Integration of pre-procedural CT or MRI allows for targeting the VT substrate, with major expected impact on VT ablation efficacy and efficiency. Advances in computational modeling may further enhance the performance of imaging, giving access to pre-operative simulation of VT. These advances in non-invasive diagnosis are increasingly being coupled with non-invasive approaches for therapy delivery. This review highlights the latest research on the use of imaging in VT procedures. Image-based strategies are progressively shifting from using images as an adjunct tool to electrophysiological techniques, to an integration of imaging as a central element of the treatment strategy.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas , Coração , Frequência Cardíaca , Ablação por Cateter/métodos , Resultado do Tratamento
9.
Herzschrittmacherther Elektrophysiol ; 33(1): 26-33, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35137276

RESUMO

The quantity of data produced and captured in medicine today is unprecedented. Technological improvements and automation have expanded the traditional statistical methods and enabled the analysis of Big Data. This has permitted the discovery of new associations with a granularity that was previously hidden to human eyes. In the first part of this review, the authors would like to provide an overview of basic Machine Learning (ML) principles and techniques in order to better understand their application in recent publications about cardiac arrhythmias. In the second part, ML-enabled advances in disease detection and diagnosis, outcome prediction, and novel disease characterization in topics like electrocardiography, atrial fibrillation, ventricular arrhythmias, and cardiac devices are presented. Finally, the limitations and challenges of applying ML in clinical practice, such as validation, replication, generalizability, and regulatory issues, are discussed. More carefully designed studies and collaborations are needed for ML to become feasible, trustworthy, accurate, and reproducible and to reach its full potential for patient-oriented precision medicine.


Assuntos
Fibrilação Atrial , Big Data , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Eletrofisiologia Cardíaca , Eletrocardiografia , Humanos , Aprendizado de Máquina
10.
Herz ; 46(4): 305-311, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34104977

RESUMO

Mechanisms sustaining atrial fibrillation are yet to be clarified. This article focuses on milestones in the theory of atrial fibrillation and addresses the different leading hypotheses concerning atrial fibrillation mechanisms. We start off with electric potential originating from the pulmonary vein, which triggers atrial fibrillation, discuss classic activation mapping and phase mapping as well as computer models, which have contributed to the our understanding of atrial fibrillation, and end with new mapping methods and studies highlighting the advantages and disadvantages of current mechanistic hypotheses. The technical evolution of mapping atrial fibrillation has led to new insights into the potential mechanisms underlying atrial fibrillation. A comparison between methods is essential for understanding the advantages and disadvantages of each method when mapping atrial fibrillation. Ultimately, the combination of several methods might shed light on the underlying mechanisms of atrial fibrillation and lead to a better understanding of atrial fibrillation and subsequently improve treatment of this condition.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento
11.
Pacing Clin Electrophysiol ; 43(3): 269-277, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31868241

RESUMO

BACKGROUND: Cryoballoon apposition is crucial for durable pulmonary vein isolation (PVI) in atrial fibrillation, yet the balloon is difficult to visualize by conventional mapping systems, and pulmonary venography may miss small or out-of-plane leaks. We report a novel imaging system that offers real-time 3D navigation of the cryoballoon within atrial anatomy that may circumvent these issues. METHODS AND RESULTS: A novel overlay guidance system (OGS) registers already-acquired segmented atrial cardiac tomography (CT) with fluoroscopy, enabling real-time visualization of the cryoballoon within tomographic left atrial imaging during PVI. Phantom experiments in a patient-specific 3D printed left atrium showed feasibility for confirming PV apposition and leaks. We applied OGS prospectively to 68 PVs during PVI in 17 patients. The cryoballoon was successfully reconstructed in all cases, and its apposition was compared to concurrent PV venography. The OGS uncovered leaks undetected by venography in nine veins (eight cases), which enabled repositioning, confirming apposition in remaining 68 veins. Concordance of OGS to venography was 83.8% (χ2 , P < .01) CONCLUSIONS: We report a new system for real-time imaging of cryoballoon catheters to ensure PV apposition within the tomography of the left atrium. While providing high concordance with other imaging modalities for confirming balloon apposition or leak, the system also identified leaks missed by venography. Future studies should determine if this tool can provide a new reference for cryoballoon positioning.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Imageamento Tridimensional , Veias Pulmonares/cirurgia , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Criocirurgia/instrumentação , Estudos de Viabilidade , Feminino , Humanos , Masculino , Imagens de Fantasmas , Flebografia
12.
Circ Arrhythm Electrophysiol ; 11(6): e005846, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29884620

RESUMO

BACKGROUND: Mechanisms for persistent atrial fibrillation (AF) are unclear. We hypothesized that putative AF drivers and disorganized zones may interact dynamically over short time scales. We studied this interaction over prolonged durations, focusing on regions where ablation terminates persistent AF using 2 mapping methods. METHODS: We recruited 55 patients with persistent AF in whom ablation terminated AF prior to pulmonary vein isolation from a multicenter registry. AF was mapped globally using electrograms for 360±45 cycles using (1) a published phase method and (2) a commercial activation/phase method. RESULTS: Patients were 62.2±9.7 years, 76% male. Sites of AF termination showed rotational/focal patterns by methods 1 and 2 (51/55 vs 55/55; P=0.13) in spatially conserved regions, yet fluctuated over time. Time points with no AF driver showed competing drivers elsewhere or disordered waves. Organized regions were detected for 61.6±23.9% and 70.6±20.6% of 1 minute per method (P=nonsignificant), confirmed by automatic phase tracking (P<0.05). To detect AF drivers with >90% sensitivity, 8 to 32 s of AF recordings were required depending on driver definition. CONCLUSIONS: Sites at which persistent AF terminated by ablation show organized activation that fluctuate over time, because of collision from concurrent organized zones or fibrillatory waves, yet recur in conserved spatial regions. Results were similar by 2 mapping methods. This network of competing mechanisms should be reconciled with existing disorganized or driver mechanisms for AF, to improve clinical mapping and ablation of persistent AF. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02997254.


Assuntos
Potenciais de Ação , Fibrilação Atrial/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Feminino , Alemanha , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
13.
Circ Arrhythm Electrophysiol ; 11(5): e006119, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29743170

RESUMO

BACKGROUND: The outcomes from pulmonary vein isolation (PVI) for atrial fibrillation (AF) are suboptimal, but the benefits of additional lesion sets remain unproven. Recent studies propose ablation of AF drivers improves outcomes over PVI, yet with conflicting reports in the literature. We undertook a systematic literature review and meta-analysis to determine outcomes from ablation of AF drivers in addition to PVI or as a stand-alone procedure. METHODS: Database search was done using the terms atrial fibrillation and ablation or catheter ablation and driver or rotor or focal impulse or FIRM (Focal Impulse and Rotor Modulation). We pooled data using random effects model and assessed heterogeneity with I2 statistic. RESULTS: Seventeen studies met inclusion criteria, in a cohort size of 3294 patients. Adding AF driver ablation to PVI reported freedom from AF of 72.5% (confidence interval [CI], 62.1%-81.8%; P<0.01) and from all arrhythmias of 57.8% (CI, 47.5%-67.7%; P<0.01). AF driver ablation when added to PVI or as stand-alone procedure compared with controls produced an odds ratio of 3.1 (CI, 1.3-7.7; P=0.02) for freedom from AF and an odds ratio of 1.8 (CI, 1.2-2.7; P<0.01) for freedom from all arrhythmias in 4 controlled studies. AF termination rate was 40.5% (CI, 30.6%-50.9%) and predicted favorable outcome from ablation(P<0.05). CONCLUSIONS: In controlled studies, the addition of AF driver ablation to PVI supports the possible benefit of a combined approach of AF driver ablation and PVI in improving single-procedure freedom from all arrhythmias. However, most studies are uncontrolled and are limited by substantial heterogeneity in outcomes. Large multicenter randomized trials are needed to precisely define the benefits of adding driver ablation to PVI.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/cirurgia , Potenciais de Ação , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
14.
Circ Arrhythm Electrophysiol ; 11(1): e005258, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29330332

RESUMO

BACKGROUND: The mechanisms by which persistent atrial fibrillation (AF) terminates via localized ablation are not well understood. To address the hypothesis that sites where localized ablation terminates persistent AF have characteristics identifiable with activation mapping during AF, we systematically examined activation patterns acquired only in cases of unequivocal termination by ablation. METHODS AND RESULTS: We recruited 57 patients with persistent AF undergoing ablation, in whom localized ablation terminated AF to sinus rhythm or organized tachycardia. For each site, we performed an offline analysis of unprocessed unipolar electrograms collected during AF from multipolar basket catheters using the maximum -dV/dt assignment to construct isochronal activation maps for multiple cycles. Additional computational modeling and phase analysis were used to study mechanisms of map variability. At all sites of AF termination, localized repetitive activation patterns were observed. Partial rotational circuits were observed in 26 of 57 (46%) cases, focal patterns in 19 of 57 (33%), and complete rotational activity in 12 of 57 (21%) cases. In computer simulations, incomplete segments of partial rotations coincided with areas of slow conduction characterized by complex, multicomponent electrograms, and variations in assigning activation times at such sites substantially altered mapped mechanisms. CONCLUSIONS: Local activation mapping at sites of termination of persistent AF showed repetitive patterns of rotational or focal activity. In computer simulations, complete rotational activation sequence was observed but was sensitive to assignment of activation timing particularly in segments of slow conduction. The observed phenomena of repetitive localized activation and the mechanism by which local ablation terminates putative AF drivers require further investigation.


Assuntos
Fibrilação Atrial/diagnóstico , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Fatores de Tempo , Resultado do Tratamento
15.
J Cardiovasc Electrophysiol ; 29(5): 687-695, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29377478

RESUMO

OBJECTIVE: To investigate mechanisms by which atrial fibrillation (AF) may terminate during ablation near the pulmonary veins before the veins are isolated (PVI). INTRODUCTION: It remains unstudied how AF may terminate during ablation before PVs are isolated, or how patients with PV reconnection can be arrhythmia-free. We studied patients in whom PV antral ablation terminated AF before PVI, using two independent mapping methods. METHODS: We studied patients with AF referred for ablation, in whom biatrial contact basket electrograms were studied by both an activation/phase mapping method and by a second validated mapping method reported not to create false rotational activity. RESULTS: In 22 patients (age 60.1 ± 10.4, 36% persistent AF), ablation at sites near the PVs terminated AF (77% to sinus rhythm) prior to PVI. AF propagation revealed rotational (n  =  20) and focal (n  =  2) patterns at sites of termination by mapping method 1 and method 2. Both methods showed organized sites that were spatially concordant (P < 0.001) with similar stability (P < 0.001). Vagal slowing was not observed at sites of AF termination. DISCUSSION: PV antral regions where ablation terminated AF before PVI exhibited rotational and focal activation by two independent mapping methods. These data provide an alternative mechanism for the success of PVI, and may explain AF termination before PVI or lack of arrhythmias despite PV reconnection. Mapping such sites may enable targeted PV lesion sets and improved freedom from AF.


Assuntos
Potenciais de Ação , Fibrilação Atrial/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
16.
Rev Port Cardiol ; 36 Suppl 1: 9-17, 2017 Nov.
Artigo em Inglês, Português | MEDLINE | ID: mdl-29126896

RESUMO

Pulmonary vein isolation (PVI) is central to ablation approaches for atrial fibrillation (AF), yet many patients still have arrhythmia recurrence after one or more procedures despite the latest technology for PVI. Ablation of rotational or focal sources for AF, which lie outside the pulmonary veins in many patients, is a practical approach that has been shown to improve success by many groups. Localized sources lie in atrial regions shown mechanistically to sustain AF in optical mapping and clinical studies of human AF, as well as computational and animal studies. Because they arise in localized atrial regions, AF sources may explain central paradoxes in clinical practice - such as how limited ablation in patient specific sites can terminate persistent AF yet extensive anatomical ablation at stereotypical locations, which should extinguish disordered waves, does not improve success in clinical trials. Ongoing studies may help to resolve many controversies in the field of rotational sources for AF. Studies now verify rotational activation by multiple mapping approaches in the same patients, at sites where ablation terminates persistent AF. However, these studies also show that certain mapping methods are less effective for detecting AF sources than others. It is also recognized that the success of AF source ablation is technique dependent. This review article provides a mechanistic and clinical rationale to ablate localized sources (rotational and focal), and describes successful techniques for their ablation as well as pitfalls to avoid. We hope that this review will serve as a platform for future improvements in the patient-tailored ablation for complex arrhythmias.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Humanos
17.
Europace ; 19(5): 769-774, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28339546

RESUMO

AIMS: Focal Impulse and Rotor Modulation (FIRM) uses 64-electrode basket catheters to identify atrial fibrillation (AF)-sustaining sites for ablation, with promising results in many studies. Accordingly, new basket designs are being tested by several groups. We set out to determine the procedural safety of adding basket mapping and map-guided ablation to conventional pulmonary vein isolation (PVI). METHODS AND RESULTS: We collected 30 day procedural safety data in five US centres for consecutive patients undergoing FIRM plus PVI (FIRM-PVI) compared with contemporaneous controls undergoing PVI without FIRM. A total of 625 cases were included in this analysis: 325 FIRM-PVI and 300 PVI-controls. FIRM-PVI patients were more likely than PVI-controls to be male (83% vs. 66%, P < 0.001) and have long-standing persistent AF (26% vs. 13%, P < 0.001) reflecting patients referred for FIRM. Total ablation time was greater for FIRM-PVI (62 ± 22 min) vs. PVI-controls (52 ± 18 min, P = 0.03). The complication rate for FIRM-PVI procedures (4.3%) was similar to controls (4.0%, P = 1) for both major and minor complications; no deaths were reported. The rate of complications potentially attributable to the basket catheter was small and did not differ between basket types (Constellation 2.8% vs. FIRMap 1.8%, P = 0.7) or between cases in which basket catheters were and were not used (P = 0.5). Complication rates did not differ between centres (P = 0.6). CONCLUSIONS: Procedural complications from the use of the basket catheters for AF mapping are low, and thus procedural safety appears similar between FIRM-PVI and PVI-controls in a large multicentre cohort. Future studies are required to determine the optimal approach to maximize the efficacy of FIRM-guided ablation.


Assuntos
Fibrilação Atrial/mortalidade , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/mortalidade , Ablação por Cateter/mortalidade , Ablação por Cateter/estatística & dados numéricos , Complicações Pós-Operatórias/mortalidade , Cirurgia Assistida por Computador/mortalidade , Fibrilação Atrial/diagnóstico por imagem , Mapeamento Potencial de Superfície Corporal/métodos , Mapeamento Potencial de Superfície Corporal/estatística & dados numéricos , Ablação por Cateter/métodos , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Prevalência , Fatores de Risco , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/estatística & dados numéricos , Taxa de Sobrevida , Resultado do Tratamento , Estados Unidos/epidemiologia
18.
J Cardiovasc Electrophysiol ; 28(6): 615-622, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28185348

RESUMO

INTRODUCTION: The mechanisms for atrial fibrillation (AF) are unclear in part because diverse mapping techniques yield diverse maps, ranging from stable organized sources to highly disordered waves. We hypothesized that AF mechanisms may be clarified if mapping techniques were compared in the same patients, and referenced to a clinical endpoint. We compared two independent AF mapping techniques in patients in whom ablation terminated persistent AF before pulmonary vein isolation (PVI). METHODS AND RESULTS: We identified 12 patients with persistent AF (61.2 ± 10.8 years, four female) in whom mapping with 64 pole baskets and technique 1 (activation/phase mapping, FIRM) identified rotational activation patterns during at least 50% of the 4-second mapping interval and targeted ablation at these rotational sites terminated AF to sinus rhythm (n = 10) or atrial tachycardia. We analyzed the unipolar electrograms of these patients to determine phase maps of activation by an independent technique 2 (Kuklik, Schotten et al., IEEE Trans Biomed Eng 2015). Compared to technique 1, technique 2 revealed a source in 12 of 12 (100%) cases with spatial concordance in all cases (P <0.05) and similar rotational characteristics. CONCLUSION: At sites where ablation terminated persistent AF, two independent mapping techniques identified stable rotational activation for multiple cycles that drove peripheral disorder. Future comparative studies referenced to a clinical endpoint may help reconcile if discrepancies between AF mapping studies reports represent techniques, patient populations or models of AF, and improve mapping to better guide ablation.


Assuntos
Potenciais de Ação , Fibrilação Atrial/diagnóstico , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração/fisiopatologia , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/fisiopatologia , Veias Pulmonares/cirurgia , Processamento de Sinais Assistido por Computador , Resultado do Tratamento
20.
Int J Biomed Imaging ; 2016: 7690391, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27051412

RESUMO

For augmented fluoroscopy during cardiac ablation, a preoperatively acquired 3D model of a patient's left atrium (LA) can be registered to X-ray images recorded during a contrast agent (CA) injection. An automatic registration method that works also for small amounts of CA is desired. We propose two similarity measures: The first focuses on edges of the patient anatomy. The second computes a contrast agent distribution estimate (CADE) inside the 3D model and rates its consistency with the CA as seen in biplane fluoroscopic images. Moreover, temporal filtering on the obtained registration results of a sequence is applied using a Markov chain framework. Evaluation was performed on 11 well-contrasted clinical angiographic sequences and 10 additional sequences with less CA. For well-contrasted sequences, the error for all 73 frames was 7.9 ± 6.3 mm and it dropped to 4.6 ± 4.0 mm when registering to an automatically selected, well enhanced frame in each sequence. Temporal filtering reduced the error for all frames from 7.9 ± 6.3 mm to 5.7 ± 4.6 mm. The error was typically higher if less CA was used. A combination of both similarity measures outperforms a previously proposed similarity measure. The mean accuracy for well contrasted sequences is in the range of other proposed manual registration methods.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA