Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Phys Imaging Radiat Oncol ; 29: 100539, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38303923

RESUMO

Background and Purpose: To improve radiotherapy (RT) planning efficiency and plan quality, knowledge-based planning (KBP) and deep learning (DL) solutions have been developed. We aimed to make a direct comparison of these models for breast cancer planning using the same training, validation, and testing sets. Materials and Methods: Two KBP models were trained and validated with 90 RT plans for left-sided breast cancer with 15 fractions of 2.6 Gy. The versions either used the full dataset (non-clean model) or a cleaned dataset (clean model), thus eliminating geometric and dosimetric outliers. Results were compared with a DL U-net model (previously trained and validated with the same 90 RT plans) and manually produced RT plans, for the same independent dataset of 15 patients. Clinically relevant dose volume histogram parameters were evaluated according to established consensus criteria. Results: Both KBP models underestimated the mean heart and lung dose equally 0.4 Gy (0.3-1.1 Gy) and 1.4 Gy (1.1-2.8 Gy) compared to the clinical plans 0.8 Gy (0.5-1.8 Gy) and 1.7 Gy (1.3-3.2 Gy) while in the final calculations the mean lung dose was higher 1.9-2.0 Gy (1.5-3.5 Gy) for both KPB models. The U-Net model resulted in a mean planning target volume dose of 40.7 Gy (40.4-41.3 Gy), slightly higher than the clinical plans 40.5 Gy (40.1-41.0 Gy). Conclusions: Only small differences were observed between the estimated and final dose calculation and the clinical results for both KPB models and the DL model. With a good set of breast plans, the data cleaning module is not needed and both KPB and DL models lead to clinically acceptable results.

2.
Z Med Phys ; 33(4): 601-617, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37202239

RESUMO

The SSRMP recommendations on reference dosimetry in kilovolt beams as used in radiation therapy were revised to establish current practice in Switzerland. The recommendations specify the dosimetry formalism, reference class dosimeter systems and conditions used for the calibration of low and medium energy x-ray beams. Practical guidance is provided on the determination of the beam quality specifier and all corrections required for converting instrument readings to absorbed dose to water. Guidance is also provided on the determination of relative dose under non-reference conditions and on the cross calibration of instruments. The effect of lack of electron equilibrium and influence of contaminant electrons when using thin window plane parallel chambers at x-ray tube potentials higher than 50kV is elaborated in an appendix. In Switzerland the calibration of the reference system used for dosimetry is regulated by law. METAS and IRA are the authorities providing this calibration service to the radiotherapy departments. The last appendix of these recommendations summarise this calibration chain.


Assuntos
Radiometria , Radioterapia de Alta Energia , Raios X , Planejamento da Radioterapia Assistida por Computador , Radiografia , Calibragem , Água
3.
Radiother Oncol ; 174: 101-108, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35839937

RESUMO

PURPOSE: This study aims to investigate the efficiency and the geometric as well as the dosimetric benefit of magnetic-resonance guided beam gating for stereotactic treatments in moving organs. METHOD: Patients treated with MR-guided (MRIdian system) SBRT for lung (n = 10) and liver (n = 10) targets were analyzed. Breath-hold gating was performed based on lesion tracking in sagittal cine MRI images. The target offset from the geometric center of the gating window with and without gating was evaluated. A dose reconstruction workflow based on convolution of these 2D position-probability maps and the daily 3D dose distribution was used to estimate the daily delivered dose including motion. The dose to the clinical target volume (CTV) and to a 2-cm ring structure around the planning target volume were evaluated. RESULTS: The applied gating protocol resulted in a mean (±standard deviation) gating efficiency of 55%±16%. Over all patients, the mean target offset (2D-root-mean-square error) was 8.3 ± 4.3 mm, which reduced to 2.4 ± 0.6 mm during gating. The dose reconstruction showed a mean deviation in CTV coverage (D95) from the static plans of -1.7%±1.8% with gating and -12.0%±8.4% if no gating would have been used. The mean dose (Dmean) in the ring structure, with respect to the static plans, showed mean deviations of -0.1%±0.3% with gating and -1.6%±1.8% without gating. CONCLUSION: The MRIdian system enables gating based on the inner anatomy and the implemented dose reconstruction workflow demonstrated geometric robust delivery of the planned radiation doses.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Fígado/diagnóstico por imagem , Pulmão , Radiometria , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
4.
Radiat Oncol ; 16(1): 217, 2021 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-34775998

RESUMO

BACKGROUND: Main purpose was to describe procedures and identify challenges in the implementation process of adaptive and non-adaptive MR-guided radiotherapy (MRgRT), especially new risks in workflow due to the new technique. We herein report the single center experience for the implementation of (MRgRT) and present an overview on our treatment practice. METHODS: Descriptive statistics were used to summarize clinical and technical characteristics of treatment and patient characteristics including sites treated between April 2019 and end of March 2020 after ethical approval. A risk analysis was performed to identify risks of the online adaptive workflow. RESULTS: A summary of the processes on the MR-Linac including workflows, quality assurance and possible pitfalls is presented. 111 patients with 124 courses were treated during the first year of MR-guided radiotherapy. The most commonly treated site was the abdomen (42% of all treatment courses). 73% of the courses were daily online adapted and a high number of treatment courses (75%) were treated with stereotactic body irradiation. Only 4/382 fractions could not be treated due to a failing online adaptive quality assurance. In the risk analysis for errors, the two risks with the highest risk priority number were both in the contouring category, making it the most critical step in the workflow. CONCLUSION: Although challenging, establishment of MRgRT as a routinely used technique at our department was successful for all sites and daily o-ART was feasible from the first day on. However, ongoing research and reports will have to inform us on the optimal indications for MRgRT because careful patient selection is necessary as it continues to be a time-consuming treatment technique with restricted availability. After risk analysis, the most critical workflow category was the contouring process, which resembles the need of experienced staff and safety check paths.


Assuntos
Implementação de Plano de Saúde , Neoplasias/patologia , Seleção de Pacientes , Garantia da Qualidade dos Cuidados de Saúde/normas , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Terapia Combinada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias/radioterapia , Neoplasias/cirurgia , Órgãos em Risco/efeitos da radiação , Prognóstico , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Reirradiação , Estudos Retrospectivos , Gestão de Riscos
5.
Phys Imaging Radiat Oncol ; 16: 109-112, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33458353

RESUMO

The introduction of real-time imaging by magnetic resonance guided linear accelerators (MR-Linacs) enabled adaptive treatments and gating on the tumor position. Different end-to-end tests monitored the accuracy of our MR-Linac during the first year of clinical operation. We report on the stability of these tests covering a static, adaptive and gating workflow. Film measurements showed gamma passing rates of 96.4% ± 3.4% for the static tests (five measurements) and for the two adaptive tests 98.9% and 99.99%, respectively (criterion 2%/2mm). The gated point dose measurements in the breathing phantom were 2.7% lower than in the static phantom.

6.
Front Oncol ; 8: 551, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30524969

RESUMO

Purpose: Stereotactic radiosurgery (SRS) is the preferred primary treatment option for patients with a limited number of asymptomatic brain metastases. In case of relapse after initial SRS the optimal salvage treatment is not well defined. Within this retrospective analysis, we investigated the feasibility of repeated courses of SRS to defer Whole-Brain Radiation Therapy (WBRT) and aimed to derive prognostic factors for patient selection. Materials and Methods: From 2014 until 2017, 42 patients with 197 brain metastases have been treated with multiple courses of SRS at our institution. Treatment was delivered as single fraction (18 or 20 Gy) or hypo-fractionated (6 fractions with 5 Gy) radiosurgery. Regular follow-up included clinical examination and contrast-enhanced cMRI at 3-4 months' intervals. Besides clinical and treatment related factors, brain metastasis velocity (BMV) as a newly described clinical prognostic metric was included and calculated between first and second treatment. Results: A median number of 1 lesion (range: 1-13) per course and a median of 2 courses (range: 2-6) per patient were administered resulting in a median of 4 (range: 2-14) metastases treated over time per patient. The median interval between SRS courses was 5.8 months (range: 0.9-35 months). With a median follow-up of 17.4 months (range: 4.6-45.5 months) after the first course of treatment, a local control rate of 84% was observed after 1 year and 67% after 2 years. Median time to out-of-field-brain-failure (OOFBF) was 7 months (95%CI 4-8 months). WBRT as a salvage treatment was eventually required in 7 patients (16.6%). Median overall survival (OS) has not been reached. Grouped by ds-GPA (≤ 2 vs. >2) the survival curves showed a significant split (p = 0.039). OS differed also significantly between BMV-risk groups when grouped into low vs. intermediate/high risk groups (p = 0.025). No grade 4 or 5 acute or late toxicity was observed. Conclusion: In selected patients with relapse after SRS for brain metastases, repeat courses of SRS were safe and minimized the need for rescue WBRT. The innovative, yet easy to calculate metric BMV may facilitate treatment decisions as a prognostic factor for OS.

7.
Environ Toxicol Chem ; 27(6): 1399-407, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18220443

RESUMO

Herbicide concentrations fluctuate in rivers following crop application and can reach high levels after rain events, yet the duration of these pulses is short. In the present study, we assessed the effect of atrazine and isoproturon pulse exposure on Scenedesmus vacuolatus (Chlorophyceae; strain 211-8b, Kessler) as well as the recovery in the postexposure period. We further explored whether the time-dependent toxicity is similar for herbicides inhibiting the photosystem II (PSII). The growth rate was assessed for different exposure durations, and in addition the inhibition of the effective quantum yield of PSII was measured to monitor the response at the target site. Atrazine and isoproturon did not have similar time-dependent effects on growth rate, despite their same primary mode of action on PSII. Atrazine was less toxic than isoproturon after 10 h of exposure, but the toxicity of both herbicides was similar after 48 h of exposure. However, both compounds inhibited the PSII effective quantum yield within 1 h following exposure. Similarly, the effective quantum yield recovered completely within 4 h after removal of the toxicants, leading to rapid recovery of algal growth. The rapid onset of effects of isoproturon on the growth of the alga during exposure suggests that a single pulse to this herbicide is likely to induce greater effects than an atrazine pulse at the same concentration, even if these effects are reversible. The information gained in the present study should support the effect assessment of sequential exposures as well as the risk evaluation of fluctuating herbicidal exposure.


Assuntos
Inibidores Enzimáticos/toxicidade , Herbicidas/administração & dosagem , Herbicidas/toxicidade , Complexo de Proteína do Fotossistema II/antagonistas & inibidores , Complexo de Proteína do Fotossistema II/metabolismo , Scenedesmus/efeitos dos fármacos , Scenedesmus/enzimologia , Inibidores Enzimáticos/administração & dosagem , Scenedesmus/crescimento & desenvolvimento , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA