Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Infection ; 52(1): 93-104, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37434025

RESUMO

BACKGROUND: The severe acute respiratory syndrome corona virus 2 (SARS-CoV-2) pandemic causes a high burden of acute and long-term morbidity and mortality worldwide despite global efforts in containment, prophylaxis, and therapy. With unprecedented speed, the global scientific community has generated pivotal insights into the pathogen and the host response evoked by the infection. However, deeper characterization of the pathophysiology and pathology remains a high priority to reduce morbidity and mortality of coronavirus disease 2019 (COVID-19). METHODS: NAPKON-HAP is a multi-centered prospective observational study with a long-term follow-up phase of up to 36 months post-SARS-CoV-2 infection. It constitutes a central platform for harmonized data and biospecimen for interdisciplinary characterization of acute SARS-CoV-2 infection and long-term outcomes of diverging disease severities of hospitalized patients. RESULTS: Primary outcome measures include clinical scores and quality of life assessment captured during hospitalization and at outpatient follow-up visits to assess acute and chronic morbidity. Secondary measures include results of biomolecular and immunological investigations and assessment of organ-specific involvement during and post-COVID-19 infection. NAPKON-HAP constitutes a national platform to provide accessibility and usability of the comprehensive data and biospecimen collection to global research. CONCLUSION: NAPKON-HAP establishes a platform with standardized high-resolution data and biospecimen collection of hospitalized COVID-19 patients of different disease severities in Germany. With this study, we will add significant scientific insights and provide high-quality data to aid researchers to investigate COVID-19 pathophysiology, pathology, and chronic morbidity.


Assuntos
COVID-19 , Humanos , COVID-19/epidemiologia , SARS-CoV-2 , Pandemias/prevenção & controle , Qualidade de Vida , Alemanha/epidemiologia , Estudos Observacionais como Assunto
2.
Clin Infect Dis ; 76(6): 1050-1058, 2023 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-36318608

RESUMO

BACKGROUND: The microbial etiology of prosthetic valve infective endocarditis (PVE) can be difficult to identify. Our aim was to investigate the benefit of molecular imaging technique fluorescence in situ hybridization (FISH) combined with 16S rRNA-gene polymerase chain reaction (PCR) and sequencing (FISHseq) for the analysis of infected prosthetic heart valves. METHODS: We retrospectively evaluated the diagnostic outcome of 113 prosthetic valves from 105 patients with suspected PVE, treated in 2003-2013 in the Department of Cardiac Surgery, Charité University Medicine Berlin. Each prosthetic valve underwent cultural diagnostics and was routinely examined by FISH combined with 16S rRNA gene PCR and sequencing. We compared classical microbiological culture outcomes (blood and valve cultures) with FISHseq results and evaluated the diagnostic impact of the molecular imaging technique. RESULTS: Conventional microbiological diagnostic alone turned out to be insufficient, as 67% of preoperative blood cultures were noninformative (negative, inconclusive, or not obtained) and 67% of valve cultures remained negative. FISHseq improved the conventional cultural diagnostic methods in PVE in 30% of the cases and increased diagnostic accuracy. Of the valve culture-negative PVE cases, FISHseq succeeded in identifying the causative pathogen in 35%. CONCLUSIONS: FISHseq improves PVE diagnostics, complementing conventional cultural methods. In addition to species identification, FISH provides information about the severity of PVE and state of the pathogens (eg, stage of biofilm formation, activity, and localization on and within the prosthetic material). As a molecular imaging technique, FISHseq enables the unambiguous discrimination of skin flora as contaminant or infectious agent.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Humanos , Endocardite Bacteriana/microbiologia , Próteses Valvulares Cardíacas/efeitos adversos , Estudos Retrospectivos , Hibridização in Situ Fluorescente , RNA Ribossômico 16S/genética , Infecções Relacionadas à Prótese/microbiologia , Endocardite/etiologia , Imagem Molecular
3.
BMC Cardiovasc Disord ; 22(1): 271, 2022 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-35710343

RESUMO

BACKGROUND: Various randomized multicenter studies have shown that percutaneous left atrial appendage closure (LAAC) is not inferior in stroke prevention compared to vitamin K antagonists (VKA) and can be performed safely and effectively. AIMS: The prospective multicenter ORIGINAL registry in the Free State of Saxony (saxOnian RegIstry analyzinG and followINg left atrial Appendage cLosure) investigated the efficiency and safety of LAAC with Watchman or Amulet device in a real word setting. A special focus was put on the influence of LAAC frequency on periprocedural efficiency and safety. METHODS AND RESULTS: The total of 482 consecutive patients (Abbott Amulet N = 93 and Boston Scientific Watchman N = 389) were included in the periinterventional analyses. After 6 weeks, 353 patients completed the first follow-up including transoesophageal echocardiography (TEE) (73.2%). Successful LAAC could be performed in more than 94%. The complication rate does not significantly differ between device types (p = 0.92) according to Fischer test and comprised 2.2% in the Amulet and 2.3% in the Watchman group. The kind of device and the frequency of LAAC per study center had no influence on the success and complication rates. Device related thrombus could be revealed more frequently in the Watchman group (4.5%) than in the Amulet group (1.4%) but this difference is still not significant in Fisher test (p = 0.14). Same conclusion can be made about residual leakage 1.1% versus 0% [not significant in Fisher test (p = 0.26)]. Dual antiplatelet therapy followed the intervention in 64% and 22% of patients were discharged under a combination of an anticoagulant (VKA/DOAC/Heparin) and one antiplatelet agent. CONCLUSIONS: The ORIGINAL registry supports the thesis from large, randomized trials that LAAC can be performed with a very high procedural success rate in the everyday clinical routine irrespective of the used LAA device (Watchman or Amulet). The postprocedural antithrombotic strategy differs widely among the participating centers. Trial registration Name of the registry: "saxOnian RegIstry analyzinG and followINg left atrial Appendage cLosure", Trial registration number: DRKS00023803; Date of registration: 15/12/2020 'Retrospectively registered'; URL of trial registry record: https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00023803 .


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Anticoagulantes/efeitos adversos , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Cateterismo Cardíaco/efeitos adversos , Fibrinolíticos/uso terapêutico , Humanos , Estudos Prospectivos , Sistema de Registros , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
4.
BMC Cardiovasc Disord ; 21(1): 235, 2021 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-33975538

RESUMO

BACKGROUND: The study analyzes changes in lung function, pulmonary pressure and diffusing capacity of the lung in patients with mitral valve regurgitation (MR) treated by MitraClip implantation. METHODS: A total of 43 patients (19 women and 24 men with an average age of 78.0 ± 6.6 years) who were able to perform pulmonary function testing including diffusing capacity of the lung for carbon monoxide (DLCO), vital capacity (VC), total lung capacity (TLC), residual volume (RV) and forced expiratory volume in 1 s (FEV1) before and 6 weeks after MitraClip implantation participated in this study. Furthermore, clinical and echocardiographic parameters including systolic pulmonary artery pressure (sPAP), left ventricular ejection fraction (LVEF) and left atrial diameter (LAD) measurements were recorded in all patients. RESULTS: The procedure was performed successfully in all 43 patients leading to a reduction of MR in 97.7% of cases. One patient died on day 4 after the intervention most likely due to pulmonary artery embolism. Six weeks after the implantation 79.1% of patients showed a MR of at most mild to moderate. Furthermore, we could demonstrate a significant reduction of systolic pulmonary artery pressure during follow-up (from 48.8 ± 11.4 mmHg to 42.9 ± 9.0 mmHg (t(41) = - 2.6, p = 0.01). However, no changes in LVEF were detected. Comparing pre and post implant lung function tests, no significant alterations were seen for VC, TLC, DLCO and FEV1. Though, in a subgroup of patients with moderate to severe preexisting deterioration of DLCO at the baseline (max. 50%) the MitraClip procedure resulted in a significant improvement in DLCO (37.8% ± 9.0 to 41.6% ± 10.0, p < 0.001). CONCLUSIONS: Treatment of MR with the MitraClip system successfully reduces MR severity in the vast majority of patients. Consecutively, a reduction in pulmonary pressure could be observed, however no changes in LVEF were obvious. Lung function tests remained unaltered during follow-up. However, in a subgroup of patients with severe preexisting deterioration of DLCO the MitraClip procedure resulted in a significant improvement in DLCO. TRIAL REGISTRATION: Name of the registry: Die Auswirkung der interventionellen Mitralklappenreparatur mit MitraClip-System auf die Ergebnisse der Lungenfunktionsmessung. TRIAL REGISTRATION NUMBER: DRKS00022435; Date of registration: 09/07/2020 'Retrospectively registered'; URL of trial registry record: https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00022435 .


Assuntos
Pressão Arterial , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Pulmão/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Artéria Pulmonar/fisiopatologia , Capacidade de Difusão Pulmonar , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Artéria Pulmonar/diagnóstico por imagem , Recuperação de Função Fisiológica , Sistema de Registros , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
6.
Strahlenther Onkol ; 197(4): 288-295, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33067652

RESUMO

PURPOSE: To quantify mean heart dose (MHD) and doses to the left anterior descending artery (LAD) and left ventricle (LV) in a retrospective series of patients who underwent perioperative accelerated partial breast irradiation with multicatheter interstitial brachytherapy (MIB-APBI). METHODS: Sixty-eight patients with low-risk left breast cancer were treated with MIB-APBI at our institution between 2012 and 2017. Interstitial tubes were inserted during the tumorectomy and sentinel node biopsy and APBI was started 6 days later. The prescribed dose was 34 Gy in 10 fractions (twice a day) to the clinical target volume (CTV). The heart, LAD, and LV were contoured and the distance between each structure and the CTV was measured. The MHD, mean and maximum LAD doses (LAD mean/max), and mean LV doses (LV mean) were calculated and corrected to biologically equivalent doses in 2­Gy fractionation (EQD2). We also evaluated the impact of the distance between the cardiac structures and the CTV and of the volume receiving the prescribed dose (V100) and high-dose volume (V150) on heart dosimetry. RESULTS: Mean EQD2 for MHD, LAD mean/max, and mean LV were 0.9 ± 0.4 Gy (range 0.3-2.2), 1.6 ± 1.1 Gy (range, 0.4-5.6), 2.6 ± 1.9 Gy (range, 0.7-9.2), and 1.3 ± 0.6 Gy (range, 0.5-3.4), respectively. MHD, LAD mean/max, and LV mean significantly correlated with the distance between the CTV and these structures, but all doses were below the recommended limits (German Society of Radiation Oncology; DEGRO). The MHD and LV mean were significantly dependent on V100. CONCLUSION: Perioperative MIB-APBI resulted in low cardiac doses in our study. This finding provides further support for the value of this technique in well-selected patients with early-stage left breast cancer.


Assuntos
Braquiterapia/métodos , Neoplasias da Mama/radioterapia , Mama/efeitos da radiação , Coração/efeitos da radiação , Feminino , Humanos , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Estudos Retrospectivos
7.
Infection ; 48(4): 619-626, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32535877

RESUMO

PURPOSE: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has spread worldwide causing a global health emergency. Pa-COVID-19 aims to provide comprehensive data on clinical course, pathophysiology, immunology and outcome of COVID-19, to identify prognostic biomarkers, clinical scores, and therapeutic targets for improved clinical management and preventive interventions. METHODS: Pa-COVID-19 is a prospective observational cohort study of patients with confirmed SARS-CoV-2 infection treated at Charité - Universitätsmedizin Berlin. We collect data on epidemiology, demography, medical history, symptoms, clinical course, and pathogen testing and treatment. Systematic, serial blood sampling will allow deep molecular and immunological phenotyping, transcriptomic profiling, and comprehensive biobanking. Longitudinal data and sample collection during hospitalization will be supplemented by long-term follow-up. RESULTS: Outcome measures include the WHO clinical ordinal scale on day 15 and clinical, functional, and health-related quality-of-life assessments at discharge and during follow-up. We developed a scalable dataset to (i) suit national standards of care, (ii) facilitate comprehensive data collection in medical care facilities with varying resources, and (iii) allow for rapid implementation of interventional trials based on the standardized study design and data collection. We propose this scalable protocol as blueprint for harmonized data collection and deep phenotyping in COVID-19 in Germany. CONCLUSION: We established a basic platform for harmonized, scalable data collection, pathophysiological analysis, and deep phenotyping of COVID-19, which enables rapid generation of evidence for improved medical care and identification of candidate therapeutic and preventive strategies. The electronic database accredited for interventional trials allows fast trial implementation for candidate therapeutic agents. TRIAL REGISTRATION: Registered at the German registry for clinical studies (DRKS00021688).


Assuntos
Infecções por Coronavirus/fisiopatologia , Pneumonia Viral/fisiopatologia , Sistema de Registros , Berlim/epidemiologia , Betacoronavirus , Bancos de Espécimes Biológicos , COVID-19 , Infecções por Coronavirus/epidemiologia , Gerenciamento Clínico , Humanos , Estudos Observacionais como Assunto , Pandemias , Fenótipo , Pneumonia Viral/epidemiologia , Estudos Prospectivos , Medição de Risco , Fatores de Risco , SARS-CoV-2 , Fatores de Tempo , Resultado do Tratamento , Organização Mundial da Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA