Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38969963

RESUMO

BACKGROUND: The clinical impact of Periprocedural myocardial injury (PMI) in patients undergoing permanent pacemaker implantation with Left Bundle Branch Area Pacing (LBBAP) is unknown. METHODS: 130 patients undergoing LBBAP from January 2020 to June 2021 and completing 12 months follow up were enrolled to assess the impact of PMI on composite clinical outcome (CCO) defined as any of the following: all-cause death, hospitalization for heart failure (HHF), hospitalization for acute coronary syndrome (ACS) and ventricular arrhythmias (VAs). High sensitivity Troponin T (HsTnT) was measured up to 24-h after intervention to identify the peak HsTnT values. PMI was defined as increased peak HsTnT values at least > 99th percentile of the upper reference limit (URL: 15 pg/ml) in patients with normal baseline values. RESULTS: PMI occurred in 72 of 130 patients (55%). ROC analysis yielded a post-procedural peak HsTnT cutoff of fourfold the URL for predicting the CCO (AUC: 0.692; p = 0.023; sensitivity 73% and specificity 71%). Of the enrolled patients, 20% (n = 26) had peak HsTnT > fourfold the URL. Patients with peak HsTnT > fourfold the URL exhibited a higher incidence of the CCO than patients with peak HsTnT ≤ fourfold the URL (31% vs. 10%; p = 0.005), driven by more frequent hospitalizations for ACS (15% vs. 3%; p = 0.010). Multiple (> 2) lead repositions attempts, the use of septography and stylet-driven leads were independent predictors of higher risk of PMI with peak HsTnT > fourfold the URL. CONCLUSIONS: PMI seems common among patients undergoing LBBAP and may be associated with an increased risk of clinical outcomes in case of more pronounced (peak HsTnT > fourfold the URL) myocardial damage occurring during the procedure.

2.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38885309

RESUMO

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) have become established in preventing sudden cardiac death, with some advantages over transvenous defibrillator systems, including a lower incidence of lead failures. Despite technological advancements, S-ICD carriers may suffer from significant complications, such as premature battery depletion (PBD), that led to an advisory for nearly 40 000 patients. This multicentre study evaluated the incidence of PBD in a large set of S-ICD patients. METHODS AND RESULTS: Data from patients implanted with S-ICD models A209 and A219 between October 2012 and July 2023 across nine centres in Europe and the USA were reviewed. Incidence and implications of PBD, defined as clinically observed sudden drop in battery longevity, were analysed and compared to PBD with the definition of battery depletion within 60 months. Prospectively collected clinical data were obtained retrospectively from medical records, device telemetry, and manufacturer reports. This registry is listed on ClinicalTrials.gov (NCT05713708). Of the 1112 S-ICD devices analysed, 547 (49.2%) were equipped with a potentially affected capacitor linked to PBD occurrence, currently under Food and Drug Administration advisory. The median follow-up time for all patients was 46 [inter-quartile range (IQR) 24-63] months. Clinically suspected PBD was observed in 159 (29.1%) of cases, with a median time to generator removal or replacement of 65 (IQR 55-72) months, indicative of significant deviations from expected battery lifespan. Manufacturer confirmation of PBD was made in 91.7% of devices returned for analysis. No cases of PBD were observed in devices that were not under advisory. CONCLUSION: This manufacturer-independent analysis highlights a notable incidence of PBD in patients equipped with S-ICD models under advisory, and the rate of PBD in this study corresponds to the rate currently estimated by the manufacturer. To the best of our knowledge, this provides the largest contemporary peer-reviewed study cohort investigating the actual incidence of PBD in S-ICD patients. These findings emphasize the importance of post-market registries in collaboration between clinicians and the manufacturer to optimize safety and efficacy in S-ICD treatment.


Assuntos
Desfibriladores Implantáveis , Fontes de Energia Elétrica , Sistema de Registros , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Estados Unidos/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/epidemiologia , Europa (Continente)/epidemiologia , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Falha de Equipamento/estatística & dados numéricos , Fatores de Tempo , Análise de Falha de Equipamento/estatística & dados numéricos , Adulto
3.
Europace ; 26(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38861398

RESUMO

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) offer potentially distinct advantages over transvenous defibrillator systems. Recent randomized trials showed significantly lower lead failure rates than transvenous ICD. Still, S-ICDs remain associated with the risk of inappropriate shocks (IAS). While previous studies have reported varying causes of IAS, this study explores a rare cause of IAS, referred to as 'sense-B-noise.' It was recently described in case series, but its incidence has not been studied in a large cohort of S-ICD patients. METHODS AND RESULTS: We retrospectively reviewed data from patients implanted with S-ICD models 1010, A209, and A219 between October 2009 and July 2023 across nine centres in Europe and the USA. The analysis concentrated on determining the incidence and understanding the implications of sense-B-noise events. Sense-B-noise represents a rare manifestation of distinct electrogram abnormalities within the primary and alternate sensing vectors. Data were collected from medical records, device telemetry, and manufacturer reports for investigation. This registry is registered on clinicaltrials.gov (NCT05713708). Subcutaneous implantable cardioverter-defibrillator devices of the 1158 patients were analysed. The median follow-up time for all patients was 46 (IQR 23-64) months. In 107 patients (9.2%) ≥1 IAS was observed during follow-up. Sense-B-noise failure was diagnosed in six (0.5 and 5.6% of all IAS) patients, in all patients, the diagnosis was made after an IAS episode. Median lead dwell time in the affected patients was 23 (2-70) months. To resolve the sense-B-noise defect, in three patients reprogramming to the secondary vector was undertaken, and two patients underwent system removal with subsequent S-ICD reimplantation due to low amplitude in the secondary vector. In one patient, the secondary vector was initially programmed, and subsequently, an S-ICD system exchange was performed due to T-wave-oversensing IAS episodes. CONCLUSION: This multicentre analysis' findings shed light on a rare but clinically highly significant adverse event in S-ICD therapy. To our knowledge, we provide the first systematic multicentre analysis investigating the incidence of sense-B-noise. Due to being difficult to diagnose and limited options for resolution, management of sense-B-noise is challenging. Complete system exchange may be the only option for some patients. Educating healthcare providers involved in S-ICD patient care is crucial for ensuring accurate diagnosis and effective management of sense-B-noise issues.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Sistema de Registros , Humanos , Masculino , Estudos Retrospectivos , Feminino , Pessoa de Meia-Idade , Incidência , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Idoso , Europa (Continente)/epidemiologia , Falha de Equipamento/estatística & dados numéricos , Estados Unidos/epidemiologia , Fatores de Risco
4.
Artigo em Inglês | MEDLINE | ID: mdl-38842970

RESUMO

Takotsubo syndrome (TTS) is a reversible form of acute myocardial injury due to a neurocardiogenic mechanism associated with a relevant risk for life-threatening ventricular arrhythmias, occurring in up to 25% of all patients and including both ventricular arrhythmias (especially) in the context of QT prolongation and atrial tachy- or bradyarrhythmias. The pathogenetic mechanisms of TTS-related arrhythmic complications are not completely understood, and there are no randomized clinical trials addressing the pharmacologic and nonpharmacologic management in this specific setting. In this narrative review, the authors provide an overview of the pathogenesis and the therapeutic management of arrhythmic complications in patients with TTS, along with the future perspectives and the remaining knowledge gaps in this field.

5.
Eur J Clin Invest ; 54(2): e14110, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37837616

RESUMO

BACKGROUND: An exuberant and dysregulated inflammatory response contributes to the development and progression of cardiovascular diseases (CVDs). METHODS: This narrative review includes original articles and reviews published over the past 20 years and found through PubMed. The following search terms (or combination of terms) were considered: "acute pericarditis," "recurrent pericarditis," "myocarditis," "cardiac sarcoidosis," "atherosclerosis," "acute myocardial infarction," "inflammation," "NLRP3 inflammasome," "Interleukin-1" and "treatment." RESULTS: Recent evidence supports the role of inflammation across a wide spectrum of CVDs including myocarditis, pericarditis, inflammatory cardiomyopathies (i.e. cardiac sarcoidosis) as well as atherosclerotic CVD and heart failure. Interleukins (ILs) are the signalling mediators of the inflammatory response. The NACHT, leucine-rich repeat and pyrin-domain containing protein 3 (NLRP3) inflammasome play a key role in producing IL-1ß, the prototypical pro-inflammatory cytokine involved in CVDs. Other pro-inflammatory cytokines (e.g. tumour necrosis factor) have been implicated in cardiac sarcoidosis. As a proof of this, IL-1 blockade has been proven efficacious in pericarditis and chronic coronary syndrome. CONCLUSION: Tailored strategies aiming at quenching the inflammatory response have emerged as promising to treat CVDs. In this review article, we summarize recent evidence regarding the role of inflammation across a broad spectrum of CVDs. We also review novel evidence regarding targeted therapeutic strategies.


Assuntos
Aterosclerose , Miocardite , Pericardite , Sarcoidose , Humanos , Proteína 3 que Contém Domínio de Pirina da Família NLR/metabolismo , Inflamassomos/metabolismo , Inflamação/metabolismo , Citocinas/metabolismo , Interleucina-1beta/metabolismo , Aterosclerose/metabolismo , Pericardite/tratamento farmacológico
7.
J Arrhythm ; 39(5): 681-756, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37799799

RESUMO

Cardiac physiologic pacing (CPP), encompassing cardiac resynchronization therapy (CRT) and conduction system pacing (CSP), has emerged as a pacing therapy strategy that may mitigate or prevent the development of heart failure (HF) in patients with ventricular dyssynchrony or pacing-induced cardiomyopathy. This clinical practice guideline is intended to provide guidance on indications for CRT for HF therapy and CPP in patients with pacemaker indications or HF, patient selection, pre-procedure evaluation and preparation, implant procedure management, follow-up evaluation and optimization of CPP response, and use in pediatric populations. Gaps in knowledge, pointing to new directions for future research, are also identified.

8.
Artigo em Inglês | MEDLINE | ID: mdl-37815298

RESUMO

ABSTRACT: Heart failure (HF) is a complex syndrome that remains a leading cause of morbidity and mortality worldwide. Abundant evidence suggests inflammation plays a key role in the development and perpetuation of HF, but there are currently no anti-inflammatory treatments approved for use in HF. Interleukin-1 (IL-1), the prototypical pro-inflammatory cytokine, has been implicated in adverse cardiac remodeling and left ventricular dysfunction. Multiple early phase clinical trials using IL-1 blockade in patients at risk for or diagnosed with HF have suggested favorable safety and efficacy in reducing inflammatory biomarkers, as well as positive signals in surrogate and clinical endpoints. Additional large scale clinical trials are urgently needed to confirm the safety and efficacy of this therapeutic approach specifically in HF. In this narrative review, we discuss current evidence regarding IL-1 blockade in the prevention and treatment of HF.

10.
Am J Cardiol ; 203: 184-192, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37499598

RESUMO

Cardiac sarcoidosis (CS) is a potentially serious form of infiltrative cardiomyopathy. Despite scarce evidence, immunosuppressive treatment is generally recommended, but local routines may vary significantly. We sought to survey the clinical practices in the treatment of CS, with the aim that the results may suggest future research priorities. We conducted a web-based survey focused on treatment-naive patients with CS. We subclassified CS according to the presence/absence of overt cardiac presentation (clinically manifest/silent) and to the presence/absence of active inflammation (metabolically active/inactive by fluorodeoxyglucose positron emission tomography). The survey was developed jointly by the authors and administered to expert clinicians (n = 79) involved in CS treatment. An agreement threshold was set at 70%. A total of 62 of 79 respondents (78.5%) from 12 countries completed the survey. The agreement threshold was reached for: (1) always treating clinically manifest, metabolically active CS, 57 of 62 (91.9%), (2) never treating clinically silent, metabolically inactive CS, 44 of 62 (71.0%), (3) not requiring histopathologic confirmation of sarcoidosis before treatment initiation, (49 of 62, 79.0%), (4) using fluorodeoxyglucose positron emission tomography for assessing treatment indication (44 of 62, 71.0%) and treatment response (44 of 62, 71.0%), and (5) using prednisone as a first-line agent (100%), although respondents were divided on monotherapy (69.4%) or combination with methotrexate 25.8%. The approach to particular scenarios, tapering, and duration of treatment showed the greatest variation in response. In conclusion, in this survey of clinical practice, important aspects of CS treatment reached the agreement threshold, whereas others showed a great degree of clinical equipoise.


Assuntos
Cardiomiopatias , Miocardite , Sarcoidose , Humanos , Fluordesoxiglucose F18/uso terapêutico , Cardiomiopatias/diagnóstico , Cardiomiopatias/tratamento farmacológico , Sarcoidose/diagnóstico , Sarcoidose/tratamento farmacológico , Prednisona , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/uso terapêutico
14.
Heart Rhythm ; 20(9): e17-e91, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37283271

RESUMO

Cardiac physiologic pacing (CPP), encompassing cardiac resynchronization therapy (CRT) and conduction system pacing (CSP), has emerged as a pacing therapy strategy that may mitigate or prevent the development of heart failure (HF) in patients with ventricular dyssynchrony or pacing-induced cardiomyopathy. This clinical practice guideline is intended to provide guidance on indications for CRT for HF therapy and CPP in patients with pacemaker indications or HF, patient selection, pre-procedure evaluation and preparation, implant procedure management, follow-up evaluation and optimization of CPP response, and use in pediatric populations. Gaps in knowledge, pointing to new directions for future research, are also identified.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Criança , Humanos , Fascículo Atrioventricular , Resultado do Tratamento , Doença do Sistema de Condução Cardíaco , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Eletrocardiografia/métodos
15.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1719-1729, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37227359

RESUMO

BACKGROUND: Multiple cardiac sarcoidosis (CS) diagnostic schemes have been published. OBJECTIVES: This study aims to evaluate the association of different CS diagnostic schemes with adverse outcomes. The diagnostic schemes evaluated were 1993, 2006, and 2017 Japanese criteria and the 2014 Heart Rhythm Society criteria. METHODS: Data were collected from the Cardiac Sarcoidosis Consortium, an international registry of CS patients. Outcome events were any of the following: all-cause mortality, left ventricular assist device placement, heart transplantation, and appropriate implantable cardioverter-defibrillator therapy. Logistic regression analysis evaluated the association of outcomes with each CS diagnostic scheme. RESULTS: A total of 587 subjects met the following criteria: 1993 Japanese (n = 310, 52.8%), 2006 Japanese (n = 312, 53.2%), 2014 Heart Rhythm Society (n = 480, 81.8%), and 2017 Japanese (n = 112, 19.1%). Patients who met the 1993 criteria were more likely to experience an event than patients who did not (n = 109 of 310, 35.2% vs n = 59 of 277, 21.3%; OR: 2.00; 95% CI: 1.38-2.90; P < 0.001). Similarly, patients who met the 2006 criteria were more likely to have an event than patients who did not (n = 116 of 312, 37.2% vs n = 52 of 275, 18.9%; OR: 2.54; 95% CI: 1.74-3.71; P < 0.001). There was no statistically significant association between the occurrence of an event and whether a patient met the 2014 or the 2017 criteria (OR: 1.39; 95% CI: 0.85-2.27; P = 0.18 or OR: 1.51; 95% CI: 0.97-2.33; P = 0.067, respectively). CONCLUSIONS: CS patients who met the 1993 and the 2006 criteria had higher odds of adverse clinical outcomes. Future research is needed to prospectively evaluate existing diagnostic schemes and develop new risk models for this complex disease.


Assuntos
Cardiomiopatias , Desfibriladores Implantáveis , Transplante de Coração , Miocardite , Sarcoidose , Humanos , Sarcoidose/diagnóstico , Sarcoidose/epidemiologia , Sarcoidose/complicações , Desfibriladores Implantáveis/efeitos adversos
17.
J Am Coll Cardiol ; 81(12): 1192-1200, 2023 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-36948737

RESUMO

Nonischemic cardiomyopathies are a frequent occurrence. The understanding of the mechanism(s) and triggers of these cardiomyopathies have led to improvement and even recovery of left ventricular function. Although chronic right ventricular pacing-induced cardiomyopathy has been recognized for many years, left bundle branch block and pre-excitation have been recently identified as potential reversible causes of cardiomyopathy. These cardiomyopathies share a similar abnormal ventricular propagation that can be recognized by a wide QRS duration with left bundle branch block pattern; thus, we coined the term abnormal conduction-induced cardiomyopathies. Such abnormal propagation results in an abnormal contractility that can only be recognized by cardiac imaging as ventricular dyssynchrony. Appropriate diagnosis and treatment will not only lead to improved left ventricular ejection fraction and functional class, but may also reduce morbidity and mortality. This review presents an update of the mechanisms, prevalence, incidence, and risk factors, as well as their diagnosis and management, while highlighting current gaps of knowledge.


Assuntos
Bloqueio de Ramo , Cardiomiopatias , Humanos , Bloqueio de Ramo/terapia , Volume Sistólico , Função Ventricular Esquerda , Doença do Sistema de Condução Cardíaco , Cardiomiopatias/diagnóstico , Cardiomiopatias/epidemiologia , Cardiomiopatias/etiologia , Arritmias Cardíacas/complicações , Resultado do Tratamento
18.
Artigo em Inglês | MEDLINE | ID: mdl-36652082

RESUMO

BACKGROUND: The subcutaneous ICD established its role in the prevention of sudden cardiac death in recent years. The occurrence of premature battery depletion in a large subset of potentially affected devices has been a cause of concern. The incidence of premature battery depletion has not been studied systematically beyond manufacturer-reported data. METHODS: Retrospective data and the most recent follow-up data on S-ICD devices from fourteen centers in Europe, the US, and Canada was studied. The incidence of generator removal or failure was reported to investigate the incidence of premature S-ICD battery depletion, defined as battery failure within 60 months or less. RESULTS: Data from 1054 devices was analyzed. Premature battery depletion occurred in 3.5% of potentially affected devices over an observation period of 49 months. CONCLUSIONS: The incidence of premature battery depletion of S-ICD potentially affected by a battery advisory was around 3.5% after 4 years in this study. Premature depletion occurred exclusively in devices under advisory. This is in line with the most recently published reports from the manufacturer. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04767516 .

19.
J Interv Card Electrophysiol ; 66(2): 311-321, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35266067

RESUMO

BACKGROUND: Left bundle branch area pacing (LBBAP) is an emerging technique to achieve cardiac resynchronization therapy (CRT), but its feasibility and safety in elderly patients with heart failure with reduced ejection fraction and left bundle branch block is hardly investigated. METHODS: We enrolled consecutive patients with an indication for CRT comparing pacing parameters and complication rates of LBBAP-CRT in elderly patients (≥ 75 years) versus younger patients (< 75 years) over a 6-month follow-up. RESULTS: LBBAP was successful in 55/60 enrolled patients (92%), among which 25(45%) were elderly. In both groups, LBBAP significantly reduced the QRS duration (elderly group: 168 ± 15 ms to 136 ± 12 ms, p < 0.0001; younger group: 166 ± 14 ms to 134 ± 11 ms, p < 0.0001) and improved LVEF (elderly group: 28 ± 5% to 40 ± 7%, p < 0.0001; younger group: 29 ± 5% to 41 ± 8%, p < 0.0001). The pacing threshold was 0.9 ± 0.8 V in the elderly group vs. 0.7 ± 0.5 V in the younger group (p = 0.350). The R wave was 9.5 ± 3.9 mV in elderly patients vs. 10.7 ± 2.7 mV in younger patients (p = 0.341). The fluoroscopic (elderly: 13 ± 7 min vs. younger: 11 ± 7 min, p = 0.153) and procedural time (elderly: 80 ± 20 min vs. younger: 78 ± 16 min, p = 0.749) were comparable between groups. Lead dislodgement occurred in 2(4%) patients, 1 in each group (p = 1.000). Intraprocedural septal perforation occurred in three patients (5%), 2(8%) in the elderly group (p = 0.585). One patient (2%) in the elderly group had a pocket infection. CONCLUSIONS: LBBAP is a feasible and safe technique for delivering physiological pacing in elderly patients who are candidates for CRT with suitable pacing parameters and low complication rates.


Assuntos
Terapia de Ressincronização Cardíaca , Humanos , Idoso , Terapia de Ressincronização Cardíaca/métodos , Fascículo Atrioventricular , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Estudos de Viabilidade , Eletrocardiografia/métodos , Resultado do Tratamento , Volume Sistólico
20.
JACC Clin Electrophysiol ; 8(12): 1500-1510, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36543499

RESUMO

BACKGROUND: Takotsubo syndrome is associated with life threatening arrhythmias, and the apical ballooning pattern is characterized by a peculiar QT prolongation and particularly high-risk of arrhythmias. OBJECTIVES: The aim of the study was to determine the association of QT interval on electrocardiogram for ventricular arrhythmic complications in patients with apical ballooning Takotsubo syndrome in a diverse population at a large urban hospital in the U.S. METHODS: We reviewed 105 cases of apical ballooning Takotsubo syndrome in patients admitted between 2011 and 2017. Two cardiologists reviewed the electrocardiograms to measure QT interval, adjusted for rate using the Fridericia formula (QTCF), and ventricular arrhythmic complications during the hospitalization. Data are reported as median and interquartile range or number and percentage. RESULTS: Of the 105 patients, 86 (82%) were female, and 34 (32%) were self-reported Black or African American. The mean age was 65 years (range: 58-72 years). Left ventricular ejection fraction was 25% (range: 25%-35%). Heart rate was 101 beats/min (range: 83-121 beats/min). Ten (11%) patients experienced a ventricular arrhythmic complication and had significantly longer QTCF (470 [range: 422-543] milliseconds) than did those without complications (417 [range: 383-456] milliseconds, P = 0.031). The area under the curve for QTCF was 0.708 (95% CI: 0.536-0.880; P = 0.031). Twenty-eight (27%) patients had a QTCF ≥460 milliseconds and significantly more arrhythmic complications (21% vs 5%, odds ratio 4.997 [95% CI: 1.288-19.237], P = 0.021). QTCF was an independent predictor of ventricular arrhythmias: odds ratio 1.090 for each 10-millisecond increase in QTCF (95% CI: 1.004-1.183; P = 0.040, corrected for sex). CONCLUSIONS: In a diverse population of patients with apical ballooning Takotsubo syndrome admitted to a large urban hospital in the United States, QTCF at admission ≥460 milliseconds identifies patients at high risk for in-hospital arrhythmic complications. Further studies are needed to determine strategies aimed at shortening QT interval to potentially prevent life-threatening arrhythmic events.


Assuntos
Síndrome do QT Longo , Cardiomiopatia de Takotsubo , Humanos , Feminino , Idoso , Masculino , Cardiomiopatia de Takotsubo/complicações , Volume Sistólico , Função Ventricular Esquerda , Síndrome do QT Longo/complicações , Síndrome do QT Longo/epidemiologia , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/complicações , Hospitais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA