Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
bioRxiv ; 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38106139

RESUMO

Biological images captured by a microscope are characterized by heterogeneous signal-to-noise ratios (SNRs) across the field of view due to spatially varying photon emission and camera noise. State-of-the-art unsupervised structured illumination microscopy (SIM) reconstruction algorithms, commonly implemented in the Fourier domain, do not accurately model this noise and suffer from high-frequency artifacts, user-dependent choices of smoothness constraints making assumptions on biological features, and unphysical negative values in the recovered fluorescence intensity map. On the other hand, supervised methods rely on large datasets for training, and often require retraining for new sample structures. Consequently, achieving high contrast near the maximum theoretical resolution in an unsupervised, physically principled manner remains a challenging task. Here, we propose Bayesian-SIM (B-SIM), an unsupervised Bayesian framework to quantitatively reconstruct SIM data, rectifying these shortcomings by accurately incorporating all noise sources in the spatial domain. To accelerate the reconstruction process for computational feasibility, we devise a parallelized Monte Carlo sampling strategy for inference. We benchmark our framework on both simulated and experimental images, and demonstrate improved contrast permitting feature recovery at up to 25% shorter length scales over state-of-the-art methods at both high- and low-SNR. B-SIM enables unsupervised, quantitative, physically accurate reconstruction without the need for labeled training data, democratizing high-quality SIM reconstruction and expands the capabilities of live-cell SIM to lower SNR, potentially revealing biological features in previously inaccessible regimes.

2.
Anal Bioanal Chem ; 414(13): 3945-3958, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35385983

RESUMO

Understanding cell-to-cell variation at the molecular level provides relevant information about biological phenomena and is critical for clinical and biological research. Proteins carry important information not available from single-cell genomics and transcriptomics studies; however, due to the minute amount of proteins in single cells and the complexity of the proteome, quantitative protein analysis at the single-cell level remains challenging. Here, we report an integrated microfluidic platform in tandem with matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for the detection and quantification of targeted proteins from small cell ensembles (> 10 cells). All necessary steps for the assay are integrated on-chip including cell lysis, protein immunocapture, tryptic digestion, and co-crystallization with the matrix solution for MALDI-MS analysis. We demonstrate that our approach is suitable for protein quantification by assessing the apoptotic protein Bcl-2 released from MCF-7 breast cancer cells, ranging from 26 to 223 cells lysed on-chip (8.75 nL wells). A limit of detection (LOD) of 11.22 nM was determined, equivalent to 5.91 × 107 protein molecules per well. Additionally, the microfluidic platform design was further improved, establishing the successful quantification of Bcl-2 protein from MCF-7 cell ensembles ranging from 8 to 19 cells in 4 nL wells. The LOD in the smaller well designs for Bcl-2 resulted in 14.85 nM, equivalent to 3.57 × 107 protein molecules per well. This work shows the capability of our approach to quantitatively assess proteins from cell lysate on the MIMAS platform for the first time. These results demonstrate our approach constitutes a promising tool for quantitative targeted protein analysis from small cell ensembles down to single cells, with the capability for multiplexing through parallelization and automation.


Assuntos
Microfluídica , Proteoma , Limite de Detecção , Proteínas Proto-Oncogênicas c-bcl-2 , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
3.
Biomed Opt Express ; 12(6): 3700-3716, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34221689

RESUMO

Linear structured illumination microscopy (SIM) is a super-resolution microscopy technique that does not impose photophysics requirements on fluorescent samples. Multicolor SIM implementations typically rely on liquid crystal on silicon (LCoS) spatial light modulators (SLM's) for patterning the excitation light, but digital micromirror devices (DMD's) are a promising alternative, owing to their lower cost and higher speed. However, existing coherent DMD SIM implementations use only a single wavelength of light, limited by the lack of efficient approaches for solving the blazed grating effect for polychromatic light. We develop the requisite quantitative tools, including a closed form solution of the blaze and diffraction conditions, forward models of DMD diffraction and pattern projection, and a model of DMD aberrations. Based on these advances, we constructed a three-color DMD microscope, quantified the effect of aberrations from the DMD, developed a high-resolution optical transfer function measurement technique, and demonstrated SIM on fixed and live cells. This opens the door to applying DMD's in polychromatic applications previously restricted to LCoS SLM's.

4.
Anal Chem ; 93(15): 6053-6061, 2021 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-33819014

RESUMO

Increasing evidence has demonstrated that cells are individually heterogeneous. Advancing the technologies for single-cell analysis will improve our ability to characterize cells, study cell biology, design and screen drugs, and aid cancer diagnosis and treatment. Most current single-cell protein analysis approaches are based on fluorescent antibody-binding technology. However, this technology is limited by high background and cross-talk of multiple tags introduced by fluorescent labels. Stable isotope labels used in mass cytometry can overcome the spectral overlap of fluorophores. Nevertheless, the specificity of each antibody and heavy-metal-tagged antibody combination must be carefully validated to ensure detection of the intended target. Thus, novel single-cell protein analysis methods without using labels are urgently needed. Moreover, the labeling approach targets already known motifs, hampering the discovery of new biomarkers relevant to single-cell population variation. Here, we report a combined microfluidic and matrix-assisted laser desorption and ionization (MALDI) mass spectrometric approach for the analysis of protein biomarkers suitable for small cell ensembles. All necessary steps for cell analysis including cell lysis, protein capture, and digestion as well as MALDI matrix deposition are integrated on a microfluidic chip prior to the downstream MALDI-time-of-flight (TOF) detection. For proof of principle, this combined method is used to assess the amount of Bcl-2, an apoptosis regulator, in metastatic breast cancer cells (MCF-7) by using an isotope-labeled peptide as an internal standard. The proposed approach will eventually provide a new means for proteome studies in small cell ensembles with the potential for single-cell analysis and improve our ability in disease diagnosis, drug discovery, and personalized therapy.


Assuntos
Microfluídica , Peptídeos , Biomarcadores , Proteoma , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
5.
Elife ; 92020 11 12.
Artigo em Inglês | MEDLINE | ID: mdl-33179596

RESUMO

We present an oblique plane microscope (OPM) that uses a bespoke glass-tipped tertiary objective to improve the resolution, field of view, and usability over previous variants. Owing to its high numerical aperture optics, this microscope achieves lateral and axial resolutions that are comparable to the square illumination mode of lattice light-sheet microscopy, but in a user friendly and versatile format. Given this performance, we demonstrate high-resolution imaging of clathrin-mediated endocytosis, vimentin, the endoplasmic reticulum, membrane dynamics, and Natural Killer-mediated cytotoxicity. Furthermore, we image biological phenomena that would be otherwise challenging or impossible to perform in a traditional light-sheet microscope geometry, including cell migration through confined spaces within a microfluidic device, subcellular photoactivation of Rac1, diffusion of cytoplasmic rheological tracers at a volumetric rate of 14 Hz, and large field of view imaging of neurons, developing embryos, and centimeter-scale tissue sections.


Assuntos
Microscopia Confocal/instrumentação , Microscopia Confocal/métodos , Análise de Célula Única/métodos , Animais , Células Cultivadas , Humanos , Camundongos , Técnicas Analíticas Microfluídicas/instrumentação , Plasmídeos , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA