Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Sci Prog ; 104(2): 368504211018583, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34003684

RESUMO

The purpose of this study was to explore conventional, diffusion, and dynamic contrast-enhanced MRI (DCE-MRI) characteristics for differentiating metaplastic Warthin's tumor (MWT) from other tumor types of the parotid gland, including non-metaplastic Warthin's tumor (non-MWT), pleomorphic adenoma (PA), and malignant tumor (MT). A total of 178 patients with histologically proven tumors of the parotid gland, including 21 MWTs, 49 non-MWTs, 66 PAs, and 42 MTs, were enrolled in the study. Conventional MRI was performed in all patients. One hundred and fifty patients had preoperative diffusion-weighted MR imaging (DWI), and 62 patients had preoperative DCE-MRI. The differences in the conventional, DCE-MRI, and DWI records between MWTs and the other three tumor types were statistically evaluated. Compared with non-MWTs and PAs, there was a statistically significant difference in circumscription (p < 0.01). The ill-defined circumscription was more common in MWTs than non-MWTs and PAs. Compared with PAs, there was a statistically significant difference in morphology (p < 0.05). The lobulated morphology was more common in PAs than MWTs. Compared with PAs and MTs, there was a statistically significant difference in the T2 signal of the solid component (p < 0.01). The T2 moderate intensity of solid components was more common in MWTs than PAs and MTs. The solid components of PAs mostly showed hyperintense on T2-weighted imaging. Cyst/necrosis was more common in MWTs than PAs and MTs. Hyperintense of cyst/necrosis was more common in MWTs and non-MWTs. With respect to contrast enhancement, 52.4% MWTs exhibited moderate or marked enhancement, and most non-MWTs (81.6%) exhibited mild enhancement. Most PAs (84.8%) exhibited marked enhancement. The mean ADC value of MWTs (0.94 × 10-3 ± 0.11 mm2/s) was significantly lower than that of the PAs (1.60 × 10-3 ± 0.17 mm2/s) (p < 0.001). On DCE-MRI, six of eight MWTs demonstrated TIC of type B. Although MWT is rare, conventional MRI characteristics, DWI and DCE-MRI can provide useful information for differentiating MWT from other parotid mass.


Assuntos
Adenolinfoma , Cistos , Neuroblastoma , Neoplasias Parotídeas , Adenolinfoma/diagnóstico por imagem , Adenolinfoma/patologia , Cistos/patologia , Diagnóstico Diferencial , Humanos , Imageamento por Ressonância Magnética/métodos , Metaplasia/patologia , Necrose/patologia , Neuroblastoma/patologia , Glândula Parótida/diagnóstico por imagem , Glândula Parótida/patologia , Neoplasias Parotídeas/diagnóstico por imagem , Neoplasias Parotídeas/patologia , Estudos Retrospectivos
2.
Front Oncol ; 10: 1063, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32793470

RESUMO

Background: Several previous reports of anaplastic ependymomas have described their imaging features, and most of these studies were case reports. However, no studies have compared the magnetic resonance imaging (MRI) features between the infratentorial and supratentorial anaplastic ependymomas. Objective: The goal of this study was to explore MRI characteristics for intracranial anaplastic ependymomas. Material and Methods: We retrospectively reviewed the demographics of 165 patients and MRI findings of 60 patients with supratentorial (SAEs) and infratentorial anaplastic ependymomas (IAEs) before surgery. The demographics and MRI features for SAEs and IAEs were compared and evaluated. Results: Among the 60 patients, most SAEs (91.7%) were extraventricular, whereas most IAEs (91.7%) were intraventricular. Of sixty intracranial anaplastic ependymomas, most lesions were well-defined (n = 45) and round-like (n = 36). On T1-weighted imaging, compared with the gray matter, the SAEs exhibited heterogeneous signal intensity, whereas IAEs exhibited iso-hypointense signals. T2 signals exhibited greater associations with hyperintense signals in IAEs; however, SAEs showed hyperintense or hypointense-hyperintense. On diffusion-weighted imaging (DWI), almost all solid tissues of SAEs appeared as hyperintense, whereas IAEs exhibited iso-hypointense signals. Peritumoral edema and intratumoral hemorrhage occurred more frequently in SAEs. Almost all anaplastic ependymomas exhibited heterogeneous enhancement. Cysts or necrosis was associated with 56 anaplastic ependymomas; however, large cysts were more prevalent in SAEs. On magnetic resonance spectroscopy (MRS), the mean choline/creatine (Cho/Cr) and choline/N-acetyl-aspartate (Cho/NAA) ratio of anaplastic ependymomas were (6.58 ± 4.26) and (8.84 ± 6.34), respectively, representing typical high-grade tumors. Conclusion: We demonstrate the conventional and functional MRI features of intracranial anaplastic ependymomas, including DWI and MRS. MRI characteristics, such as location, cyst, diffusion restriction, and peritumoral edema, differed between supratentorial and infratentorial locations. Cho/Cr and Cho/ NAA ratios of anaplastic ependymomas are increased.

4.
Abdom Imaging ; 39(2): 323-33, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24389893

RESUMO

OBJECTIVE: The purpose of this study was to evaluate MRI features for the differentiation of hepatic angiomyolipoma (HAML) from fat-containing hepatocellular carcinoma. METHODS: We retrospectively reviewed the MRI findings of 20 patients with 22 hepatic angiomyolipomas and 25 patients with fat-containing hepatocellular carcinomas before surgery. The MRI features and apparent diffusion coefficient (ADC) for the two types of tumors were compared and analyzed. RESULTS: Fat was not detected in nine (40.9%) of the angiomyolipomas. An enhancement pattern of the washout area was seen in eight (36.4%) of the angiomyolipomas and 21 of the hepatocellular carcinomas (84%) (p = 0.001). The sensitivity, specificity, and accuracy of the enhancement pattern for HAML were 63.6% (14/22), 84% (21/25), and 74.5% (35/47), respectively. An early draining vein was seen in 16 (72.7%) angiomyolipomas and two hepatocellular carcinomas (8%) (p < 0.001). The sensitivity, specificity, and accuracy of an early draining vein for detecting HAML was 72.7% (16/22), 92% (23/25), and 83.0% (39/47), respectively. Tumor vessels were noted in 18 (81.8%) angiomyolipomas and six hepatocellular carcinomas (24%) (p < 0.001). The sensitivity, specificity, and accuracy of tumor vessels for HAML were 81.8% (18/22), 76% (19/25), and 78.7% (37/47), respectively. Pseudocapsules were absent in 21 (95.5%) angiomyolipomas as compared with 3 (12%) hepatocellular carcinomas (p < 0.001). The sensitivity, specificity, and accuracy of pseudocapsules for HAML were 95.5% (21/22), 88% (22/25), and 91.5% (43/47), respectively. The ADC of the angiomyolipomas (1.92 ± 0.29 × 10(-3 )mm(2)/s) was significantly higher than that for hepatocellular carcinomas (1.33 ± 0.25 × 10(-3 )mm(2)/s) (p < 0.001). CONCLUSION: The presence of an early draining vein and tumor vessels, the absence of pseudocapsules and a higher ADC in the hypervascular hepatic tumor on the MRI were helpful for the differentiation of hepatic angiomyolipoma from fat-containing hepatocellular carcinoma.


Assuntos
Angiomiolipoma/patologia , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Meios de Contraste , Diagnóstico Diferencial , Imagem de Difusão por Ressonância Magnética , Feminino , Gadolínio DTPA , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
5.
Acta Radiol ; 54(8): 909-15, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23817682

RESUMO

BACKGROUND: The low-dose computed tomography (CT) technique has been widely used because it decreases the potential risk of radiation exposure, as well as enabling low-dose CT-guided lung lesion biopsy. However, uncertainties remain regarding diagnostic accuracy, radiation dose, complication rate, and image quality. PURPOSE: To compare the diagnostic accuracy, radiation dose, complication rate, and image quality of lung lesion biopsy between conventional CT-guided and low-dose CT-guided techniques. MATERIAL AND METHODS: A total of 90 patients were prospectively enrolled and randomized into two groups (group A: 120 kv; 200 mA; thickness, 2.0 mm; pitch, 16 mm/rot; n = 44; group B: 120 kv;10 mA; thickness, 2.0 mm; pitch, 23 mm/rot; n = 46). Sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), radiation dose, image quality, and complication rate were compared. All variables between the two groups were analyzed using chi-square and Student's t tests. A P value of < 0.05 was considered statistically significant. RESULTS: The sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) for diagnosing lung lesions were 96.88%, 100%, 97.5%, 100%, and 88.89% in group A, respectively. In group B, the values were 96.67%, 100%, 97.5%, 100%, and 90.91%, respectively (P > 0.05). The mean weighted CT dose index (CTDIw) and dose-length product (DLP) were 29.29 ± 3.93 mGy and 211.74 ± 37.89 mGy*cm in group A and 1.55 ± 0.15 mGy and 10.98 ± 1.56 mGy*cm in group B (P < 0.001). Image quality satisfied the need for a coaxial biopsy. Complications in group A and group B were observed in 27.28% and 23.91% of the patients, respectively (P > 0.05). CONCLUSION: Compared to conventional CT-guided biopsies, lung lesion biopsies guided by the low-dose CT biopsy protocol showed dramatically lower CTDIw and DLP levels. In contrast, the diagnostic yield of the procedures did not differ significantly, which is a recommended technique in certain populations.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Doses de Radiação , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Estudos de Viabilidade , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
7.
Eur J Radiol ; 82(9): 1506-11, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23561057

RESUMO

OBJECTIVE: Dynamic contrast enhanced MR imaging (DCE-MRI) allows imaging of the physiology of the microcirculation. The purpose of this study was to determine the diagnostic efficacy of time intensity curve (TIC) and DCE parameters for characterization of orbital masses. METHODS: Fifty-nine patients with untreated orbital lesions underwent DCE-MRI before surgery. For each lesion, peak height (PH), maximum enhancement ratio (ERmax), time of peak enhancement (Tpeak) and maximum rise slope (Slopemax) were plotted and calculated. Receiver operator characteristics (ROC) analysis was conducted to assess the appropriate cut-off value. RESULTS: All 26 lesions that demonstrated persistent pattern (type-I) TICs were benign. Most of the masses with the washout pattern (type-III) TIC were malignant (10/14), including lymphoma (n=6) and melanoma (n=4). The Slopemax of benign lesions was statistically lower than malignant ones, while the ERmax and Tpeak values of benign lesions were significantly higher. No statistical difference was found in PH (P=0.121). The AUC for ERmax, Tpeak and Slopemax in differentiating benign orbital lesions from malignant ones were 0.683, 0.837 and 0.738, respectively. In the three DCE parameters, Slopemax cut-off value of 1.10 provided the highest sensitivity of 93.8%; however, the corresponding specificity was low (58.1%). The ERmax cut-off value of 1.37 and Tpeak cut-off value of 35.14 respectively offered the best diagnostic performances. CONCLUSION: DCE-MRI, especially the qualitative TIC pattern and quantitative value of Slopemax, ERmax and Tpeak, could be a complementary investigation in distinguishing malignant orbital tumor from benign ones.


Assuntos
Algoritmos , Meios de Contraste , Neoplasias Oculares/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Diagnóstico Diferencial , Humanos , Aumento da Imagem/métodos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA