Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Anal Toxicol ; 25(7): 559-64, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11599600

RESUMO

In this study, we investigated the effectiveness of the Roche Kinetic Interaction of Microparticles in Solution (KIMS) screening assay for cannabinoid metabolites. Urine specimens (N = 1689) were collected during elimination of cannabinoids from 25 subjects with a history of marijuana use. Specimens were analyzed concurrently for cannabinoid metabolites by a customized Department of Defense (DOD) cannabinoid KIMS kit (50-ng/mL cutoff) and for 11-nor-9-carboxy-delta9-tetrahydrocannabinol (THC-COOH) by GC-MS (15-ng/mL cutoff). As compared to GC-MS results, the sensitivity, specificity, and efficiency of the KIMS assay were 69.7%, 99.8%, and 88.6%, respectively. Many of the false-negative results had GC-MS concentrations between 15 and 26 ng/mL (N = 151). The cannabinoid screening results for the DOD samples tested by the laboratory during the same 8-month period were also evaluated. The linear regression analyses of GC-MS results in the 15-50 ng/mL range and KIMS data resulted in regression coefficients of 0.689 for the research specimens and 0.546 for DOD specimens. The results suggest that the KIMS cannabinoid screening assay is deficient in detecting positives around the cutoff (15-25 ng/mL THC-COOH). This limitation of the KIMS cannabinoid screening method compromises the identification of true positive specimens, therefore reducing the effectiveness of the assay. The success of the DOD program is dependent on sensitive and specific screening assays; the high prevalence of false-negative cannabinoid results compromises the program's primary objective of drug deterrence.


Assuntos
Dronabinol/análogos & derivados , Dronabinol/farmacocinética , Dronabinol/urina , Alucinógenos/farmacocinética , Fumar Maconha , Adulto , Técnicas de Química Analítica/métodos , Dronabinol/análise , Reações Falso-Negativas , Cromatografia Gasosa-Espectrometria de Massas , Alucinógenos/análise , Humanos , Cinética , Tamanho da Partícula , Valores de Referência , Sensibilidade e Especificidade , Detecção do Abuso de Substâncias/métodos
2.
J Anal Toxicol ; 25(7): 616-20, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11599610

RESUMO

Benzoylecgonine (BZE) extraction from urine was explored using Cerex Polycrom Clin II solid-phase extraction (SPE) columns and the Speedisk 48 Pressure Processor as an alternative to the Prep1 automated sample processor and XTRX Type RP/W columns. Linearity for urine standards extracted using the Cerex-Speedisk method ranged from 20 to 3000 ng/mL. The mean recovery at the 100-ng/mL cutoff for three lots of columns was 92%. The mean of the within-run means for three batches, which had coefficients of variations of 1.8% or less, was 101.3 ng/mL at the 100-ng/mL cutoff level. Forty-six specimens known to contain BZE were analyzed by both the Prep1-Type RP/W and Cerex-Speedisk methods. The correlation for specimen BZE concentrations between the two methods gave an r2 of 0.9999 and a slope of 1.03. The Cerex-Speedisk system is an inexpensive alternative to the Prep1-Type RP/W system. It is less costly, requires little maintenance, has a small footprint, is hood compatible, and can process four times the number of specimens in a given time.


Assuntos
Cromatografia por Troca Iônica/métodos , Cocaína/análogos & derivados , Cocaína/urina , Automação , Transtornos Relacionados ao Uso de Cocaína/diagnóstico , Humanos , Tamanho da Partícula , Sensibilidade e Especificidade , Detecção do Abuso de Substâncias/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA