Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Anal Sci ; 39(10): 1771-1775, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37378820

RESUMO

Nitroxyl radical compounds oxidize hydroxy groups and some amino groups upon application of an electric potential. The resulting anodic current depends on the concentration of these functional groups in solution. Thus, it is possible to quantify compounds containing these functional groups by electrochemical methods. Cyclic voltammetry has been used to evaluate the catalytic activity of nitroxyl radicals, and the ability of such radicals to sense biological and other compounds. In this study, we evaluated a method for quantifying compounds using constant-potential electrolysis (amperometry) of nitroxyl radicals for application in flow injection analysis and high-performance liquid chromatography as an electrochemical detector. When amperometry was performed using 2,2,6,6-tetramethylpiperidine 1-oxyl, a common nitroxyl radical compound, little change was observed even with 100 mM glucose due to its low reactivity in neutral aqueous solutions. In contrast, 2-azaadamantane N-oxyl and nortropine N-oxyl, which are highly active nitroxyl radicals, showed a concentration-dependent response in neutral aqueous solution. Responses of 33.8 and 125.9 µA, respectively, were observed. By recognition of hydroxy and amino groups, we have succeeded in the electrochemical detection of some drugs by amperometry. Streptomycin, an aminoglycoside antibiotic, was quantifiable in the range of 30-1000 µM.


Assuntos
Antibacterianos , Óxidos de Nitrogênio , Cromatografia Líquida de Alta Pressão/métodos , Óxidos de Nitrogênio/química , Óxidos N-Cíclicos/química
2.
Anal Sci ; 39(3): 369-374, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36576651

RESUMO

Nitroxyl radicals are known to electrochemically oxidize thiols as well as alcohols and amines. In this study, a preliminary investigation of the electrochemical reaction of thiols with 9-azabicyclo[3.3.1]nonane N-oxyl (ABNO), 2-azaadamantane N-oxyl (AZADO), and nortropine N-oxyl (NNO), which are highly active due to their bicyclo structures, for use in electrochemical analysis was performed and the results were compared with those for a typical nitroxyl radical compound, 2,2,6,6-tetramethylpiperidine N-oxyl (TEMPO). Mercaptopropane sulfonic acid (MPS) was used as a model compound to investigate the electrochemical response in aqueous solution. In addition, electrochemical detection of glutathione, a biological thiol molecule, was performed.

3.
RSC Adv ; 11(35): 21622-21628, 2021 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-35478798

RESUMO

Quantifying drug concentrations in vivo quickly and easily is possible using electrochemical methods. The present study describes the electrochemical detection of vancomycin (VCM) and other antibiotics from the current obtained using nitroxyl radicals as electrocatalysts. Nortropine N-oxyl (NNO), which is more active than 2,2,6,6-tetramethylpiperidine 1-oxyl (TEMPO), a typical nitroxyl radical compound, produced greater current values for drugs with intramolecular hydroxy groups and secondary and tertiary amines. However, because the catalytic action of NNO is inactivated by primary amines in the substrate, VCM and teicoplanin with primary amines could not be detected. TEMPO was less active than NNO but not inactivated against primary amines. Therefore, electrochemical sensing of vancomycin was done using 4-acetamido-2,2,6,6-tetramethylpiperidine 1-oxyl (A-TEMPO), which has a greater oxidation capacity than TEMPO due to its electron-withdrawing groups. As a result, the current of A-TEMPO increased in the low concentration range of VCM as compared to TEMPO. This method also was able to quantify VCM in the concentration range of 10-100 µM, which is an important concentration range for drug monitoring in blood.

5.
Anal Sci ; 37(4): 633-635, 2021 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-33100301

RESUMO

In this paper we propose a novel measurement for NO and ·OH by electrochemical detection using sesamol. Standard samples of the sesamol monomer and dimer were subjected to differential pulse voltammetry, resulting in their peaks being clearly separated and detected. Based on the oxidative dimerization of sesamol, the current simple, sensitive and selective method was successfully applied to preliminary measurements for NO and ·OH, respectively.


Assuntos
Benzodioxóis , Fenóis , Oxirredução , Polímeros
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA