Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Med Phys ; 49(1): 73-83, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38828075

RESUMO

Background: Accurate dose measurements are difficult in small fields due to charge particle disequilibrium, partial source occlusion, steep dose gradient, and the finite size of the detector. Aim: The study aims to determine the output factor using various detectors oriented in parallel and perpendicular orientations for three different tertiary collimating systems using 15 MV photon beams. In addition, this study analyzes how the output factor could be affected by different configurations of X and Y jaws above the tertiary collimators. Materials and Methods: Small field output factor measurements were carried out with three detectors for different tertiary collimating systems such as BrainLab stereotactic cones, BrainLab mMLC and Millennium MLC namely. To analyze the effect of jaw position on output factor, measurements have been carried out by positioning the jaws at the edge, 0.25, 0.5, and 1.0 cm away from the tertiary collimated field. Results: The data acquired with 15 MV photon beams show significant differences in output factor obtained with different detectors for all collimating systems. For smaller fields when compared to microDiamond, the SRS diode underestimates the output by up to -1.7% ± 0.8% and -2.1% ± 0.3%, and the pinpoint ion chamber underestimates the output by up to -8.1% ± 1.4% and -11.9% ± 1.9% in their parallel and perpendicular orientation respectively. A large increase in output factor was observed in the small field when the jaw was moved 0.25 cm symmetrically away from the tertiary collimated field. Conclusion: The investigated data on the effect of jaw position inferred that the position of the X and Y jaw highly influences the output factors of the small field. It also confirms that the output factor highly depends on the configuration of X and Y jaw settings, the tertiary collimating system as well as the orientation of the detectors in small fields.

2.
J Med Phys ; 47(1): 65-72, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35548030

RESUMO

Background: The experimental determination of relative output factors presents the greatest challenge, especially for small fields with different detectors. The aim of this study is to evaluate the influence of jaw positions on small-field output factors for the fields defined by micro-multileaf collimator and circular cones with different detectors. Materials and Methods: The stereotactic output factors were measured on Primus linear accelerator with BrainLab micro-multileaf collimator (mMLC) and circular cones as add-on tertiary collimators. Square field sizes ranging from 0.6 cm × 0.6 cm to 9.8 cm × 9.8 cm and circular fields of diameter ranging from 1.0 cm to 4.0 cm were defined by mMLC and circular cones, respectively. The influence of jaw position on output factor was assessed for different geometric configurations with three different detectors. Results: The values obtained with PinPoint ion chamber were consistent with microDiamond detector for fields greater than 24 mm × 24 mm, but an underestimation of 23.9% was noticed in 6 mm x 6 mm field size. For the mMLC defined field size of 6 mm × 6 mm, when the X-Y jaw was moved from 8 mm × 8 mm to 80 mm × 80 mm, an increase in the output by a factor of 1.7 was observed with both microDiamond and stereotactic radiosurgery diode, whereas an increase in output by a factor of 1.9 was noticed with PinPoint ion chamber. Conclusion: Output factors obtained with different detectors show high differences in the smallest field size for all collimating systems. This study confirms that the position of X and Y jaw above the tertiary collimator significantly influences the small-field output factor.

3.
J Cancer Res Ther ; 12(2): 858-63, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27461664

RESUMO

OBJECTIVE: The use of image guidance during radiotherapy for accurate localization and setup has become the standard care of practice in radiotherapy. This mostly involves the use of kilovoltage-cone beam computed tomography (kV-CBCT) for verification of patient setup on the first few days and on a weekly basis. Some protocols require this to be performed daily and also before and after the treatment. Though the radiation due to this kV-CBCT is small, the repeated use could deliver a dose that could increase the probability of the stochastic effect. The main purpose of this work is to measure radiation dose during image guidance with kV-CBCT. MATERIALS AND METHODS: In this work, we have attempted to measure the dose during kV-CBCT for different sites both on a humanoid phantom and on patients undergoing image-guided radiotherapy with MOSFETs calibrated against an ion chamber. RESULTS: The dose measurement on patients during kV-CBCT resulted in mean doses of 0.19 and 0.3 cGy to the ipsilateral and contralateral eyes, 0.625 and 1.097 cGy to the surface of the ipsilateral and contralateral breasts, and 3.01 cGy to the surface of the pelvis. CONCLUSION: Radiation dose to the eye, breast, and the surface of the pelvis have been arrived at during CBCT. The doses measured on patients agreed closely with those measured on humanoid phantom and with published values.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Doses de Radiação , Radiometria , Dosagem Radioterapêutica , Radioterapia/métodos , Humanos , Imagens de Fantasmas , Radioterapia/normas , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes
4.
J Med Phys ; 40(3): 123-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26500397

RESUMO

The main objective of this study was to investigate the characteristics of metal oxide semiconductor field effect transistor (MOSFET) dosimeter for kilovoltage (kV) X-ray beams in order to perform the in vivo dosimetry during image guidance in radiotherapy. The performance characteristics of high sensitivity MOSFET dosimeters were investigated for 80, 90, 100, 110, 120, and 125 kV X-ray beams used for imaging in radiotherapy. This study was performed using Clinac 2100 C/D medical electron linear accelerator with on-board imaging and kV cone beam computed tomography system. The characteristics studied in this work include energy dependence, angular dependence, and linearity. The X-ray beam outputs were measured as per American Association of Physicists in Medicine (AAPM) TG 61 recommendations using PTW parallel plate (PP) ionization chamber, which was calibrated in terms of air kerma (Nk) by the National Standard Laboratory. The MOSFET dosimeters were calibrated against the PP ionization chamber for all the kV X-ray beams and the calibration coefficient was found to be 0.11 cGy/mV with a standard deviation of about ±1%. The response of MOSFET was found to be energy independent for the kV X-ray energies used in this study. The response of the MOSFET dosimeter was also found independent of angle of incidence for the gantry angles in the range of 0° to 360° in-air as well as at 3 cm depth in tissue equivalent phantom.

5.
J Med Phys ; 39(3): 142-9, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25190992

RESUMO

The characteristics of a mobile metal oxide semiconductor field effect transistor (mobile MOSFET) detector for standard bias were investigated for megavoltage photon beams. This study was performed with a brass alloy build-up cap for three energies namely Co-60, 6 and 15 MV photon beams. The MOSFETs were calibrated and the performance characteristics were analyzed with respect to dose rate dependence, energy dependence, field size dependence, linearity, build-up factor, and angular dependence for all the three energies. A linear dose-response curve was noted for Co-60, 6 MV, and 15 MV photons. The calibration factors were found to be 1.03, 1, and 0.79 cGy/mV for Co-60, 6 MV, and 15 MV photon energies, respectively. The calibration graph has been obtained to the dose up to 600 cGy, and the dose-response curve was found to be linear. The MOSFETs were found to be energy independent both for measurements performed at depth as well as on the surface with build-up. However, field size dependence was also analyzed for variable field sizes and found to be field size independent. Angular dependence was analyzed by keeping the MOSFET dosimeter in parallel and perpendicular orientation to the angle of incidence of the radiation with and without build-up on the surface of the phantom. The maximum variation for the three energies was found to be within ± 2% for the gantry angles 90° and 270°, the deviations without the build-up for the same gantry angles were found to be 6%, 25%, and 60%, respectively. The MOSFET response was found to be independent of dose rate for all three energies. The dosimetric characteristics of the MOSFET detector make it a suitable in vivo dosimeter for megavoltage photon beams.

6.
Adv Virol ; 2013: 196704, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23840211

RESUMO

Introduction. Patients with chronic liver disease (CLD) are more likely to have severe morbidity and fatality rate due to superimposed acute or chronic hepatitis B (HBV) infection. The literature has shown that hepatitis B vaccines are safe and effective in patients with CLD, but the data in cirrhosis liver is lacking. We assessed the safety and immunogenicity of HBV vaccine in patients with cirrhosis liver. Methods. CTP classes A and B CLD patients negative for hepatitis B surface antigen and antibody to hepatitis B core antigen were included. All patients received three doses of hepatitis B vaccine 20 mcg intramuscularly at 0, 30, and 60 days. Anti-HBs antibody was measured after 120 days. Results. 52 patients with mean age 47.48 ± 9.37 years were studied. Response rates in CTP classes A and B were 88% and 33.3%. We observed that the alcoholic chronic liver disease had less antibody response (44%) than other causes of chronic liver disease such as cryptogenic 69% and HCV 75%. Conclusions. Patients with cirrhosis liver will have low antibody hepatitis B titers compared to general population. As the age and liver disease progress, the response rate for hepatitis B vaccination will still remain to be weaker.

7.
J Clin Diagn Res ; 7(12): 2970-2, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24551695

RESUMO

Stromal tumours occurring in areas other than the GastroIntestinal Tract (GIT) are known as Extra GastroIntestinal Stromal Tumours (EGISTs). They usually arise in the mesentery, omentum or retroperitoneum, while EGISTs which occur in the abdominal wall are very rare. Both gastrointestinal stromal tumours (GISTs) and EGISTs are histologically and immunophenotypically similar. We are reporting a case of EGIST, which occurred in the anterior abdominal wall in a twenty five-year-old female patient. The tumour was present in the right loin and imaging studies suggested that it was a desmoid tumour. It was surgically excised by doing an abdominal wall mesh repair. The histological examinations revealed a tumour with spindle cell morphology, with <2 mitoses per 50 High Power Field (HPF) and no necrosis, with tumour free margins. Immunohistochemistry was strongly positive for CD117 and Smooth Muscle Actin (SMA), while it was negative for ß-catenin and S100. The patient is well post operatively and is on close follow up. EGISTs should be considered in the differential diagnosis of mesenchymal tumours which occur in the abdominal wall, inspite of their rarity, as the high risk patients may need Imatinib chemotherapy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA