Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Front Med Technol ; 6: 1384008, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38756327

RESUMO

Cardiovascular diseases remain a global health challenge, prompting continuous innovation in medical technology, particularly in Cardiovascular MedTech. This article provides a comprehensive exploration of the transformative landscape of Cardiovascular MedTech in the 21st century, focusing on interventions. The escalating prevalence of cardiovascular diseases and the demand for personalized care drive the evolving landscape, with technologies like wearables and AI reshaping patient-centric healthcare. Wearable devices offer real-time monitoring, enhancing procedural precision and patient outcomes. AI facilitates risk assessment and personalized treatment strategies, revolutionizing intervention precision. Minimally invasive procedures, aided by robotics and novel materials, minimize patient impact and improve outcomes. 3D printing enables patient-specific implants, while regenerative medicine promises cardiac regeneration. Augmented reality headsets empower surgeons during procedures, enhancing precision and awareness. Novel materials and radiation reduction techniques further optimize interventions, prioritizing patient safety. Data security measures ensure patient privacy in the era of connected healthcare. Modern technologies enhance traditional surgeries, refining outcomes. The integration of these innovations promises to shape a healthier future for cardiovascular procedures, emphasizing collaboration and research to maximize their transformative potential.

2.
Diagnostics (Basel) ; 14(10)2024 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-38786352

RESUMO

Vascular calcifications in aorto-iliac arteries are emerging as crucial risk factors for cardiovascular diseases (CVDs) with profound clinical implications. This systematic review, following PRISMA guidelines, investigated methodologies for measuring these calcifications and explored their correlation with CVDs and clinical outcomes. Out of 698 publications, 11 studies met the inclusion criteria. In total, 7 studies utilized manual methods, while 4 studies utilized automated technologies, including artificial intelligence and deep learning for image analyses. Age, systolic blood pressure, serum calcium, and lipoprotein(a) levels were found to be independent risk factors for aortic calcification. Mortality from CVDs was correlated with abdominal aorta calcification. Patients requiring reintervention after endovascular recanalization exhibited a significantly higher volume of calcification in their iliac arteries. Conclusions: This review reveals a diverse landscape of measurement methods for aorto-iliac calcifications; however, they lack a standardized reproducibility assessment. Automatic methods employing artificial intelligence appear to offer broader applicability and are less time-consuming. Assessment of calcium scoring could be routinely employed during preoperative workups for risk stratification and detailed surgical planning. Additionally, its correlation with clinical outcomes could be useful in predicting the risk of reinterventions and amputations.

3.
Ann Vasc Surg ; 106: 16-24, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38641000

RESUMO

BACKGROUND: The risk of radiation exposure in the surgical operating room (OR) and/or catheterization laboratory is now well established. Complex endovascular procedures often require multiple approaches and different positioning of the staff members around the patient, potentially increasing the levels of radiations exposure. Our goal was to evaluate the levels of radiation exposure of the members of the staff during endovascular aortic procedures in order to propose radioprotection optimization. METHODS: We included 41 aortic endovascular procedures out of 114 procedures performed between January 12, 2014, and August 31, 2015, including 24 standard endovascular aortic aneurysm repair (EVAR), 7 EVAR with iliac branch (EVARib), 8 complex fenestrated/branched EVAR (F/B EVAR), and 2 thoracic EVAR (TEVAR). Procedures were performed in an OR equipped with a carbon fiber table and a mobile fluoroscopy C-arm. We collected the usual dosimetry data given by the C-arm as well as the patient's peak skin dose (PSD). In all staff members, radiation exposure was measured with thermoluminescent chip dosimeters placed on both temples, on posterior sides of both hands, and on both lower legs. RESULTS: PSD levels were low for EVAR because 24 patients had values below the reading threshold. PSD significantly increased with more complex procedures. Main operator (MO) received the higher level of irradiation on whole body, hands, and ankles. Eye lenses irradiation was higher on both assistant operators (AOs). Other members received low levels of irradiation. We found a high ranges of radiation exposure with a high risk of exposure for the AO, mainly for F/B EVAR and EVARib. CONCLUSIONS: Even if all personal protections are used, staff positioning is a major point that must be considered. If MO is supposed to be the most exposed to X-rays, specific conditions of positioning of the AO may be at risk of exposure.

4.
EJVES Vasc Forum ; 61: 81-84, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38435641

RESUMO

Objective: To analyse case reports published on the latest generations of endograft (EG) and understand the mechanisms of type III endoleak (EL) development. Methods: A literature review was undertaken of English language case reports and series that concerned modular junction or component disconnection (type IIIa EL) and fabric perforations (type IIIb EL) after endovascular aneurysm repair. Results: Of the 2 785 studies, 56 full texts were chosen to review 73 cases. Type III EL was diagnosed with computed tomography angiography in 67.1% and digital subtraction angiography in 12.3%; the rest were identified during surgery. Of the 73 EG, 65 (89.0%) were made of polyethylene terephthalate and seven (9.6%) were polytetrafluoroethylene. The type of material was not mentioned in one (1.4%) case report. There were 25 (34.2%) type IIIa and 48 (65.8%) type IIIb EL. The most frequent were trunk-trunk in nine (12.3%) and trunk-limb overlap separations in 14 (19.2%). Type IIIb EL in the trunk area was identified in 27 (37.0%) cases, while 21 (28.8%) defects were found in the limbs. Stent fractures were recognised as an underlying mechanism of type IIIb EL development in one report. A combination of fabric lesions in the trunk and limb area was found in one case. Seven type IIIb EL were related to suture disruption or suture-fabric abrasions. Four cases were related to stent-fabric abrasions, and two developed as a result of fabric fatigue owing to kinking. Information on the mechanisms of degradation was only occasionally and scarcely presented. Given the small number of reports and lack of detailed analysis, no definitive conclusions could be drawn. Conclusion: The available information is scarce and does not allow any definitive conclusions to be drawn on the mechanisms that lead to the development of type III EL. Further explant analyses would be beneficial.

5.
Transpl Int ; 37: 12085, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38379606

RESUMO

In patients with severe aorto-iliac calcifications, vascular reconstructions can be performed in order to allow kidney transplantation. The aim of this study was to analyze the outcomes of kidney transplant candidates who underwent an aortobifemoral bypass (ABFB) for aorto-iliac calcifications. A retrospective study including all kidney transplant candidates who underwent an ABFB between 2012 and 2022 was performed. Primary outcome was 30-day morbidity-mortality after ABFB. Secondary outcome was accessibility to kidney transplant waiting list. Twenty-two ABFBs were performed: 10 ABFBs in asymptomatic patients presenting severe aorto-iliac circumferential calcifications without hemodynamic consequences, and 12 ABFBs in symptomatic patients in whom aorto-iliac calcifications were responsible for claudication or critical limb threatening ischemia. Overall 30-day mortality was 0%. Overall 30-day morbidity was 22.7%: 1 femoral hematoma and 1 retroperitoneal hematoma requiring surgical drainage in the asymptomatic group, and 2 digestive ischemia requiring bowel resection and 1 femoral hematoma requiring surgical drainage in the symptomatic group. Among the 22 patients, 20 patients could access to kidney waiting list and 8 patients underwent a kidney transplantation, including 3 living-donor transplantations. Aorto-iliac revascularization can be an option to overcome severe calcifications contraindicating kidney transplantation.


Assuntos
Arteriopatias Oclusivas , Transplante de Rim , Humanos , Arteriopatias Oclusivas/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Isquemia/cirurgia , Hematoma
6.
EJVES Vasc Forum ; 61: 51-53, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38328688

RESUMO

Introduction: Organ transplantation is limited by the supply of transplantable organs, and the supply of organs cannot meet the needs of patients on the waiting list. Ensuring transplantation of any procured organ is therefore mandatory. Organ injury, mostly to the organ's vasculature, can occur during multi-organ procurement, preventing subsequent transplantation. In such a context, vascular reconstructions of arterial or venous organ injuries can be useful. Report: This report describes the case of an obese 64 year old female with a history of diabetic nephropathy who underwent a cadaveric kidney transplant (right kidney with one main renal artery, one inferior polar artery, one vein, and one ureter). The ex situ preparation of the graft revealed that the main renal artery was injured and cut close to the renal hilum (0.8 cm length, 6 mm diameter), not allowing graft implantation. In order to increase the length of the main renal artery, the donor inferior vena cava was used to create a tubular conduit, allowing subsequent graft implantation. Cold and warm ischaemic times were respectively 12 hours and 36 minutes, with immediate graft function. The patient was discharged on day 8 (serum creatinine level was 95 µmol/L). Twelve month follow up was uneventful (serum creatinine level was 108 µmol/L and duplex ultrasonography showed homogeneous blood flow throughout the graft). Discussion: This case report highlights the possibility of overcoming an injured kidney graft artery by creating a tubular vena cava conduit in order to allow subsequent transplantation. Vascular reconstructions of organs injured during procurement should be considered.

7.
Eur J Vasc Endovasc Surg ; 67(3): 446-453, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37717814

RESUMO

OBJECTIVE: To analyse explanted endografts (EGs) and describe fabric degradation responsible for type IIIb endoleaks. METHODS: As part of the European collaborative retrieval programme, 32 EGs with fabric defects on macroscopic evaluation were selected. The explanted EGs were processed and studied based on the ISO 9001 certified standard protocol. It includes instructions on the collection, transportation, cleaning, and examination of explanted material. The precise analysis was performed with a digital microscope of 20 - 200 times magnification. Possible perforation mechanisms were assessed in stress tests. RESULTS: The median time to explantation of the 32 EGs was 54 months. The explants included 65 separate EG modules, with 46 (70.8%) having a combined 388 fabric perforations. Each EG had a median of 4.79 mm2 (interquartile range [IQR] 9.86 mm2) of cumulated hole area (an average of 0.13% of an EG's area). There were 239 (61.6%) expanded polytetrafluoroethylene (ePTFE; 11 EGs) and 149 (38.4%) polyethylene terephthalate (PET; 21 EGs) fabric ruptures, with no difference in hole distribution between these types of material. Overall, 126 (32.5%) stent related and 262 (67.5%) non-stent related fabric perforations were identified. Perforations caused by fabric fatigue in ePTFE (151, 63.2%) and material kinking in PET (41, 27.5%) were the most common. The stent related perforations were larger in size (0.80 mm2) than non-stent related perforations (0.19 mm2); p < .001. Wider interstent spaces and prolonged implantation duration were associated with an increased risk of stent related perforation development; p < .001 and p = .004, respectively. Large stent related perforations were also detected in the short term, suggesting mechanical issues as underlying causes. CONCLUSION: The fabric of EGs may degrade and lead to the development of perforations. The largest perforations are stent related. Their occurrence and size depend on the implantation time and the EG shape affected by arterial tortuosity. The conclusions are limited to the samples from a select explant group.

8.
EJVES Vasc Forum ; 60: 53-56, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37811160

RESUMO

Introduction: Aortic epithelioid angiosarcoma (AEA) is a rare malignant tumour and can cause acute limb ischaemia. Report: A 66 year old man was admitted with acute pulmonary oedema due to bilateral renal artery stenosis. An incidental osteolytic left sacral lesion was found on computed tomography angiography, and extensive work up revealed an AEA. Follow up was marked by acute left lower limb ischaemia 13 months later and right chronic limb threatening ischaemia 15 months later. Discussion: Physicians need to consider AEA as an aetiology for acute or chronic limb ischaemia in patients with altered general status but mostly with intra-aortic irregular vegetations without any calcification and parietal involvement on computed tomography angiography.

9.
EJVES Vasc Forum ; 60: 64-67, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37876922

RESUMO

Introduction: Calcification of a vascular endograft and adjacent tissues (adventitia, media, and neointima) can result in graft failure. This report shows a rare case of intraluminal calcifications in the distal end of a thoracic endovascular aortic repair (TEVAR) endograft implanted 11 years previously for grade IV blunt traumatic aortic injury (BTAI) in a young patient. Report: A 24 year old man required TEVAR for a BTAI caused by a motorcycle accident. The procedure consisted of TEVAR and an emergency left carotid subclavian venous bypass. Eleven years after the procedure, he had severe hypertension. Intra-TEVAR calcifications appeared, gradually increasing on computed tomography angiography (CTA). Calcifications in the distal luminal end of the TEVAR were responsible for a 60% stenosis on CTA. An open approach was indicated after multidisciplinary discussion, based on the gradient value. The patient underwent explantation, with total replacement of the aortic arch and descending thoracic aorta with re-implantation of the supra-aortic vessels, under extracorporeal circulation. Macroscopic analysis showed no device degeneration but revealed a solid mass at the distal end of the TEVAR. Both microcomputed tomography and histopathology confirmed the calcific nature of the lesions. Conclusion: This case highlights a rare long term graft failure due to calcified neo-atherosclerosis in a TEVAR.

10.
J Vasc Surg ; 78(3): 815-816, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37599034
11.
Eur J Vasc Endovasc Surg ; 66(3): 331, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37423599
12.
EJVES Vasc Forum ; 60: 1-7, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37416860

RESUMO

Objective: Calcification of vascular grafts, including polyethylene terephthalate (PET) and expanded polytetrafluoroethylene (ePTFE) grafts may contribute to graft failure, but is under reported. The aim of this study was to review the literature to assess whether vascular graft calcification is deleterious to vascular graft outcomes. Data sources: The Medline and Embase databases were searched. Review methods: A systematic literature search according to PRISMA Guidelines was performed using a combined search strategy of MeSH terms. The MeSH terms used were "calcification, physiologic", "calcinosis", "vascular grafting", "blood vessel prosthesis", "polyethylene terephthalates", and "polytetrafluoroethylene". Results: The systematic search identified 17 cases of PET graft calcification and 73 cases of ePTFE graft calcification over a 35 year period. All cases of PET graft calcification were reported in grafts explanted for graft failure. The majority of cases of ePTFE graft calcification were unexpectedly noted in grafts used during cardiovascular procedures and subsequently removed. Conclusion: Calcification of synthetic vascular grafts is under reported but can compromise the long term performance of the grafts. More data, including specific analysis of radiological findings as well as explant analysis are needed to obtain a more sensitive and specific analysis of the prevalence and incidence of vascular graft calcification and the impact of calcification on synthetic graft outcomes.

13.
JVS Vasc Sci ; 4: 100097, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37168663

RESUMO

Objectives: The aim of this study was to analyze a series of new generations of explanted knitted polyethylene terephthalate (PET) vascular grafts (VGs) presenting nonanastomotic degradations according to preoperative computed tomography angiography (CTA) when available in order to better understand the mechanisms leading to rupture. Methods: Explanted knitted PET VGs were collected as part of the Geprovas European Collaborative Retrieval Program. VGs implanted after 1990 presenting a nonanastomotic rupture of the fabric were included. Clinical data and pre-explantation CTA data when available were retrieved for each VG. The ruptures were characterized by macroscopic examination and optical microscopy according to a standardized protocol. Results: Nineteen explants were collected across 11 European centers, 13 were implanted as infrainguinal bypasses, 3 at the aortic level, and 1 as an axillobifemoral bypass. The mean implantation duration was 9.2 years. Pre-explantation CTA data were available for 8 VGs and showed false aneurysms at the adductor canal level on 4 VGs, at the inguinal ligament level on 2 VGs, and in the proximal or middle third thigh level on 3 VGs. Examination revealed longitudinal ruptures on 9 explanted VGs (EVGs), transversal ruptures on 15 EVGs, 45°-oriented ruptures on 5 EVGs, V-shaped ruptures on 7 EVGs, and punctiform ruptures on 2 EVGs. Ruptures involved the remeshing line on 11 EVGs, the guideline on 10 EVGs, and the crimping valley on 15 EVGs.At the microscopic level, two main degradation phenomena could be identified: a decrease in the density of the meshing and local ruptures of the PET fibers. Fourteen EVGs presented a loosening of the remeshing line and 17 EVGs an attenuation of the crimping. Conclusions: New-generation PET VG degradation seems to result from both anatomic constraints and intrinsic textile structure phenomena.

14.
JCI Insight ; 8(5)2023 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-36719758

RESUMO

Vascular calcification (VC) is concomitant with atherosclerosis, yet it remains uncertain why rupture-prone high-risk plaques do not typically show extensive calcification. Intraplaque hemorrhage (IPH) deposits erythrocyte-derived cholesterol, enlarging the necrotic core and promoting high-risk plaque development. Pro-atherogenic CD163+ alternative macrophages engulf hemoglobin:haptoglobin (HH) complexes at IPH sites. However, their role in VC has never been examined to our knowledge. Here we show, in human arteries, the distribution of CD163+ macrophages correlated inversely with VC. In vitro experiments using vascular smooth muscle cells (VSMCs) cultured with HH-exposed human macrophage - M(Hb) - supernatant reduced calcification, while arteries from ApoE-/- CD163-/- mice showed greater VC. M(Hb) supernatant-exposed VSMCs showed activated NF-κB, while blocking NF-κB attenuated the anticalcific effect of M(Hb) on VSMCs. CD163+ macrophages altered VC through NF-κB-induced transcription of hyaluronan synthase (HAS), an enzyme that catalyzes the formation of the extracellular matrix glycosaminoglycan, hyaluronan, within VSMCs. M(Hb) supernatants enhanced HAS production in VSMCs, while knocking down HAS attenuated its anticalcific effect. NF-κB blockade in ApoE-/- mice reduced hyaluronan and increased VC. In human arteries, hyaluronan and HAS were increased in areas of CD163+ macrophage presence. Our findings highlight an important mechanism by which CD163+ macrophages inhibit VC through NF-κB-induced HAS augmentation and thus promote the high-risk plaque development.


Assuntos
Aterosclerose , Placa Aterosclerótica , Calcificação Vascular , Camundongos , Humanos , Animais , NF-kappa B , Ácido Hialurônico , Camundongos Knockout para ApoE , Macrófagos , Aterosclerose/complicações , Apolipoproteínas E/genética
15.
16.
JVS Vasc Sci ; 3: 193-204, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35495568

RESUMO

Background: The objective of the present study was to evaluate the bioresorption rate of collagen coating (CC) sealed on textile vascular grafts (VGs) and their healing in humans using histologic analysis of explanted VGs. Methods: A total of 27 polyester textile VGs had been removed during surgery from 2012 to 2020. The segments underwent histologic assessment. The CC bioresorption rate was assessed using morphometric analysis to determine the internal and external capsule thickness, inflammatory reaction degree, presence of neovessels, and endothelial cell layer. Results: A total of 27 VGs were explanted from 25 patients because of infection (n = 5; 18.5%), thrombosis (n = 7; 25.9%), stenosis (n = 2; 7.4%), rupture (n = 4; 14.8%), aneurysmal degeneration (n = 3; 11.1%), revascularization (n = 4; 14.8%), or another cause (n = 2; 7.4%), with a median implantation duration of 291 days (interquartile range [IQR], 48-911 days). VGs with remaining CC (n = 7; 26%) had been explanted earlier than had those without (n = 20; 74%; 1 day [IQR, 1-45 days] vs 516 days [IQR, 79-2018 days]; P = .001). After 1 year, no remaining CC was detected on the analyzed VG sections. VGs implanted for <90 days had had a greater CC maximal thickness (63.90 µm [IQR, 0-83.25 µm] vs 0 µm [IQR, 0-0 µm]; P = .006) and a greater CC surface coverage (180° [IQR, 0°-360°] vs 0° [IQR, 0°-0°]; P = .002) than those implanted for >90 days. VGs implanted for >90 days had a greater external capsule thickness (889.2 µm [IQR, 39.6-1317 µm] vs 0 µm [IQR, 0-0 µm]; P = .002), a higher number of inflammatory mononuclear cells and giant cells (168 cells [IQR, 110-310 cells] vs 0 cells [IQR, 0-94 cells]; P < .0001) and a higher number of neovessels (4 [IQR, 0-5] vs 0 [IQR, 0-0]; P = .001) than those implanted for <90 days. Conclusions: CC had a slow bioresorption rate in humans. Complete healing was never achieved, with no endothelial coverage observed. This finding implies that CC might not help graft healing.

18.
EJVES Vasc Forum ; 54: 21-26, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35128504

RESUMO

BACKGROUND: Oncovascular teams are known to be a cornerstone in planning and facilitating en bloc resection of large retroperitoneal masses. Vascular surgeons can help with dissection close to major vessels by vascular reconstruction when necessary, and also in performing specific procedures that can facilitate safe and optimal tumour mass resection. Two cases are reported where temporary vascular debranching of major arteries allowed safe tumour harvesting. CASE REPORTS: A 68 year old man with a necrotic retroperitoneal carcinoma underwent en bloc resection with temporary debranching of the coeliac trunk, superior mesenteric artery, and right renal artery using a multibranched bypass from the axillary artery. The post-operative course included septic shock related to pulmonary infection requiring a 10 day stay in the intensive care unit (ICU). Renal function was normalised on day two. The patient was discharged on day 18. However, he died 78 months post-operatively from pulmonary metastases after anti-angiogenic treatment.A 34 year old man with a retroperitoneal mature teratoma underwent en bloc resection with temporary debranching of the coeliac trunk, superior mesenteric artery, left and right renal arteries, and left and right common iliac arteries, with a multibranched bypass from the axillary artery. Post-operatively he required a five day stay in the ICU. Acute kidney injury (AKI) was noted, but it resolved without dialysis. The patient was discharged on day 16. After 78 months follow up he presented with chronic renal failure requiring dialysis. Follow up computed tomography angiography showed pulmonary metastases; although the metastases were manageable with surgical treatment, the patient refused further care. CONCLUSIONS: Temporary extra-anatomical bypass from the axillary artery to the visceral arteries could be considered as an option to provide adequate perfusion and to prevent visceral ischaemia during en bloc resection of large retroperitoneal masses.

19.
EJVES Vasc Forum ; 53: 2-8, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34604828

RESUMO

OBJECTIVE: In the 1990s, the concept of "homemade" endografts (EGs) using commercially available materials was proposed in clinical practice for endovascular abdominal aortic repair (EVAR). The aim of this study was to analyse the ageing phenomena of these EGs in light of explant analyses. METHODS: The study focused on five explanted homemade EGs collected from 2012 to 2014. The explants were assessed in accordance with the ISO 9001/13485 certified standard protocol, which included naked eye evaluation, organic remnant cleaning, and microscopic and endoscopic examinations and analysis (magnification range from 20% to 200%). The observations report followed a classification based on 12 features assessing the fabric cover, the stitch filament, and the stents. RESULTS: The reasons for explantation were type 1 endoleak in three cases and aneurysm sac growth in two. The implantation duration ranged from 56 to 202 months. Sixty three per cent of the fabric surface lesions (holes and tears) were related to abrasion between the fabric and the stents. Up to 33% of the knots used to connect adjacent stents were broken on one EG. Other defects including running suture rupture and stent corrosion were also observed. The overall hole cumulated surface ranged from 0.377 mm2 (56 month of implantation) up to 3.21 mm2 (78 month of implantation). CONCLUSION: In this study, various ageing phenomena on homemade textile EGs were identified and classified. The main damaging mechanisms were related to abrasion stress leading to tears and holes in the fabric, stitch ruptures, and detachment of stent segments responsible for serious EG deformations and further degradation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA