RESUMO
PURPOSE: In cochlear implantation (CI) surgery, there are a wide variety of intraoperative tests available. However, no clear guide exists on which tests must be performed as the minimum intraoperative testing battery. Toward this end, we studied the usage patterns, recommendations, and attitudes of practitioners toward intraoperative testing. METHODS: This study is a multicentric international survey of tertiary referral CI centers. A survey was developed and administered to a group of CI practitioners (n = 34) including otologists, audiologists and biomedical engineers. Thirty six participants were invited to participate in this study based on a their scientific outputs to the literature on the intraoperative testing in CI field and based on their high load of CI surgeries. Thirty four, from 15 countries have accepted the invitation to participate. The participants were asked to indicate the usage trends, perceived value, influence on decision making and duration of each intraoperative test. They were also asked to indicate which tests they believe should be included in a minimum test battery for routine cases. RESULTS: Thirty-two (94%) experts provided responses. The most frequently recommended tests for a minimum battery were facial nerve monitoring, electrode impedance measurements, and measurements of electrically evoked compound action potentials (ECAPs). The perceived value and influence on surgical decision-making also varied, with high-resolution CT being rated the highest on both measures. CONCLUSION: Facial nerve monitoring, electrode impedance measurements, and ECAP measurements are currently the core tests of the intraoperative test battery for CI surgery.
RESUMO
OBJECTIVE: To evaluate objective and subjective hearing outcomes in experienced cochlear implant users with single sided deafness (SSD CI) who used fitting maps created via anatomy-based fitting (ABF) and clinically-based fitting (CBF). PARTICIPANTS: Twelve SSD CI users with postlingual hearing loss. INTERVENTION: OTOPLAN (Version 3. (MED-EL) was used to determine intracochlear electrode contact positions using post-operative high-resolution flat panel volume computed tomography. From these positions, the corresponding center frequencies and bandwidths were derived for each channel. These were implemented in the clinical fitting software MAESTRO to yield an ABF map individualized to each user. MAIN OUTCOME MEASURES: ABF and CBF maps were compared. Objective speech perception in quiet and in noise, binaural effects, and self-perceived sound quality were evaluated. RESULTS: Significantly higher speech perception in noise scores were observed with the ABF map compared to the CBF map (mean SRT50: -6.49 vs. -4.8 dB SNR for the S0NCI configuration and - 3.85 vs. -2.75 dB SNR for the S0N0 configuration). Summation and squelch effects were significantly increased with the ABF map (0.86 vs. 0.21 dB SNR for summation and 0.85 vs. -0.09 dB SNR for squelch). No improvement in speech perception in quiet or spatial release from masking were observed with the ABF map. A similar level of self-perceived sound quality was reported for each map. Upon the end of the study, all users opted to keep the ABF map. This preference was independent of the angular insertion depth of the electrode array. CONCLUSIONS: Experienced SSD CI users preferred using the ABF map, which gave them significant improvements in binaural hearing and some aspects of speech perception.
RESUMO
BACKGROUND: The size of the human cochlear, measured by the diameter of the basal turn, varies between 7 and 11â¯mm. For hearing rehabilitation with cochlear implants (CI), the size of the cochlear influences the individual frequency map and the choice of electrode length. OTOPLAN® (CAScination AG [Bern, Switzerland] in cooperation with MED-EL [Innsbruck, Austria]) is a software tool with CE marking for clinical applications in CI treatment which allows for precise pre-planning based on cochlear size. This literature review aims to analyze all published data on the application of OTOPLAN®. MATERIALS AND METHODS: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were applied to identify relevant studies published in the PubMed search engine between January 2015 and February 2023 using the search terms "otoplan" [title/abstract] OR "anatomy-based fitting" [title/abstract] OR "otological software tool" [title/abstract] OR "computed tomography-based software AND cochlear" [title/abstract]. RESULTS: The systematic review of the literature identified 32 studies on clinical use of OTOPLAN® in CI treatment. Most studies were reported from Germany (7 out of 32), followed by Italy (5), Saudi Arabia (4), the USA (4), and Belgium (3); 2 studies each were from Austria and China, and 1 study from France, India, Norway, South Korea, and Switzerland. In the majority of studies (22), OTOPLAN® was used to assess cochlear size, followed by visualizing the electrode position using postoperative images (5), three-dimensional segmentation of temporal bone structures (4), planning the electrode insertion trajectory (3), creating a patient-specific frequency map (3), planning of a safe drilling path through the facial recess (3), and measuring of temporal bone structures (1). CONCLUSION: To date, OTOPLAN® is the only DICOM viewer with CE marking in the CI field that can process pre-, intra-, and postoperative images in the abovementioned applications.
RESUMO
OBJECTIVES: A wide variety of intraoperative tests are available in cochlear implantation. However, no consensus exists on which tests constitute the minimum necessary battery. We assembled an international panel of clinical experts to develop, refine, and vote upon a set of core consensus statements. DESIGN: A literature review was used to identify intraoperative tests currently used in the field and draft a set of provisional statements. For statement evaluation and refinement, we used a modified Delphi consensus panel structure. Multiple interactive rounds of voting, evaluation, and feedback were conducted to achieve convergence. RESULTS: Twenty-nine provisional statements were included in the original draft. In the first voting round, consensus was reached on 15 statements. Of the 14 statements that did not reach consensus, 12 were revised based on feedback provided by the expert practitioners, and 2 were eliminated. In the second voting round, 10 of the 12 revised statements reached a consensus. The two statements which did not achieve consensus were further revised and subjected to a third voting round. However, both statements failed to achieve consensus in the third round. In addition, during the final revision, one more statement was decided to be deleted due to overlap with another modified statement. CONCLUSIONS: A final core set of 24 consensus statements was generated, covering wide areas of intraoperative testing during CI surgery. These statements may provide utility as evidence-based guidelines to improve quality and achieve uniformity of surgical practice.
Assuntos
Implante Coclear , Consenso , Técnica Delphi , Humanos , Implante Coclear/normas , Cuidados Intraoperatórios/normas , Testes Auditivos/normasRESUMO
BACKGROUND: The size of the human cochlear, measured by the diameter of the basal turn, varies between 7 and 11â¯mm. For hearing rehabilitation with cochlear implants (CI), the size of the cochlear influences the individual frequency map and the choice of electrode length. OTOPLAN® (CAScination AG [Bern, Switzerland] in cooperation with MED-EL [Innsbruck, Austria]) is a software tool with CE marking for clinical applications in CI treatment which allows for precise pre-planning based on cochlear size. This literature review aims to analyze all published data on the application of OTOPLAN®. MATERIALS AND METHODS: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were applied to identify relevant studies published in the PubMed search engine between January 2015 and February 2023 using the search terms "otoplan" [title/abstract] OR "anatomy-based fitting" [title/abstract] OR "otological software tool" [title/abstract] OR "computed tomography-based software AND cochlear" [title/abstract]. RESULTS: The systematic review of the literature identified 32 studies on clinical use of OTOPLAN® in CI treatment. Most studies were reported from Germany (7 out of 32), followed by Italy (5), Saudi Arabia (4), the USA (4), and Belgium (3); 2 studies each were from Austria and China, and 1 study from France, India, Norway, South Korea, and Switzerland. In the majority of studies (22), OTOPLAN® was used to assess cochlear size, followed by visualizing the electrode position using postoperative images (5), three-dimensional segmentation of temporal bone structures (4), planning the electrode insertion trajectory (3), creating a patient-specific frequency map (3), planning of a safe drilling path through the facial recess (3), and measuring of temporal bone structures (1). CONCLUSION: To date, OTOPLAN® is the only DICOM viewer with CE marking in the CI field that can process pre-, intra-, and postoperative images in the abovementioned applications.
Assuntos
Implante Coclear , Software , Cirurgia Assistida por Computador , Humanos , Cóclea/cirurgia , Cóclea/diagnóstico por imagem , Implante Coclear/métodos , Implantes Cocleares , Alemanha , Cirurgia Assistida por Computador/métodos , Resultado do TratamentoRESUMO
PURPOSE: To study outcome after cochlear implantation using the Cochlear Implant (CI) outcome assessment protocol based on the International Classification of Functioning, Disability and Health (ICF) model (CI-ICF). METHODS: Raw data of a prospective, longitudinal, multicenter study was analyzed. Seventy-two CI candidates were assessed preoperatively and six months postoperatively using the CI-ICF protocol. Following tools were used: (1) Work Rehabilitation Questionnaire (WORQ), (2) Abbreviated Profile of Hearing Aid Benefit (APHAB), (3) Audio Processor Satisfaction Questionnaire (APSQ), (4) Speech, Spatial, and Qualities of Hearing Scale (SSQ12), (5) Hearing Implant Sound Quality Index (HISQUI19), (6) Nijmegen CI Questionnaire (NCIQ) (7) pure tone audiometry, (8) speech audiometry, (9) sound localization. RESULTS: There was a significant improvement of speech discrimination in quiet (p = 0.015; p < 0.001) and in noise (p = 0.041; p < 0.001), sound detection (p < 0.001), tinnitus (p = 0.026), listening (p < 0.001), communicating with-receiving-spoken messages (p < 0.001), conversation (p < 0.001), family relationships (p < 0.001), community life (p = 0.019), NCIQ total score and all subdomain scores (p < 0.001). Subjective sound localization significantly improved (p < 0.001), while psychometric sound localization did not. There was no significant subjective deterioration of vestibular functioning and no substantial change in sound aversiveness. CI users reported a high level of implant satisfaction postoperatively. CONCLUSION: This study highlights the positive impact of cochlear implantation on auditory performance, communication, and subjective well-being. The CI-ICF protocol provides a holistic and comprehensive view of the evolution of CI outcomes.
Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Prospectivos , Idoso , Adulto , Estudos Longitudinais , Percepção da Fala , Inquéritos e Questionários , Classificação Internacional de Funcionalidade, Incapacidade e Saúde , Resultado do Tratamento , Satisfação do Paciente , Avaliação da Deficiência , Adulto Jovem , Avaliação de Resultados em Cuidados de Saúde , Audiometria de Tons Puros , AdolescenteRESUMO
BACKGROUND: Correct individual tonotopic frequency stimulation of the cochlea plays an important role in the further development of anatomy-based cochlear implantation. In this context, frequency-specific fitting of the basal electrode contact with a normal insertion depth can be difficult since it is often placed in a frequency range higher than 10 kHz, and current audio processors only stimulate for frequencies up to 8.5 kHz due to microphone characteristics. This results in a mismatch of the high frequencies. Therefore, this study represents a proof of concept for a tonotopic correct insertion and aims to develop an algorithm for a placement of the basal electrode below 8.5 kHz in an experimental setting. METHODS: Pre- and postoperative flat-panel volume CT scans with secondary reconstructions were performed on 10 human temporal bone specimens. The desired frequency location for the most basal electrode contact was set at 8.25 kHz. The distance from the round window to the position where the basal electrode contact was intended to be located was calculated preoperatively using 3D-curved multiplanar reconstruction and a newly developed mathematical approach. A specially designed cochlear implant electrode array with customized markers imprinted on the silicone of the electrode array was inserted in all specimens based on the individually calculated insertion depths. All postoperative measurements were additionally validated using otological planning software. RESULTS: Positioning of the basal electrode contact was reached with only a small mean deviation of 37 ± 399 Hz and 0.06 ± 0.37 mm from the planned frequency of 8.25 kHz. The mean rotation angle up to the basal electrode contact was 51 ± 5°. In addition, the inserted electrode array adequately covered the apical regions of the cochleae. CONCLUSION: Using this algorithm, it was possible to position the basal electrode array contact in an area of the cochlea that could be correctly stimulated by the existing speech processors in the context of tonotopic correct fitting.
Assuntos
Algoritmos , Cóclea , Implante Coclear , Implantes Cocleares , Osso Temporal , Humanos , Implante Coclear/métodos , Osso Temporal/diagnóstico por imagem , Osso Temporal/cirurgia , Osso Temporal/anatomia & histologia , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Cóclea/anatomia & histologia , Estudo de Prova de Conceito , Eletrodos Implantados , Tomografia Computadorizada por Raios XRESUMO
OBJECTIVE: To investigate the surgical approach and the audiological outcome of a stapes head coupler in active middle ear implant surgery. STUDY DESIGN: Retrospective data analysis. SETTING: Tertiary referral center with a large active middle ear implant program. PATIENTS: Twelve patients with active middle ear implant surgery. INTERVENTIONS: Therapeutic surgical approach for hearing rehabilitation in human subjects. MAIN OUTCOME MEASURES: Auditory brainstem response, sound field thresholds, vibrogram, speech perception in the Freiburger monosyllabic word test. RESULTS: The stapes head was attached safely in different coupling situations. Audiological outcomes were similar to the audiological performance of established vibroplasty couplers presented in the literature. CONCLUSION: The stapes head coupler is a new and safe tool for vibroplasty with a good audiological outcome.
Assuntos
Perda Auditiva Condutiva-Neurossensorial Mista , Prótese Ossicular , Humanos , Estribo , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Perda Auditiva Condutiva-Neurossensorial Mista/reabilitação , Estudos Retrospectivos , Audição , Resultado do TratamentoRESUMO
OBJECTIVE: In auditory brainstem implant (ABI) surgery, array placement may be optimized by electrophysiological information of adequate brainstem activation gained from electrically evoked auditory brainstem responses (EABR). This study aims 1) to characterize in detail the EABR from ABI implantation, 2) to introduce an EABR Classification Scheme, and 3) to analyze data for their correlation with individual patients' findings. METHODS: Out of a continuous series of 54 patients who received an ABI between 2005 and 2019, 23 Neurofibromatosis Type 2 patients with complete documentation of 154 recordings were selected for offline analysis and for development and evaluation of a new EABR Classification Scheme comprising Class A: three vertex positive peaks, Class B:two peaks, Class C: a combination of one peak and a second melted double peak, Class D: one sole vertex positive peak and Class E: no peaks. RESULTS: All 23 subjects showed EABR at final ABI position and experienced auditory sensations at first activation. The most frequent morphology consisted of two peaks, Classes B and C. Identified mean latencies were for P1 0.42 ms (±0.095), P2 1.42 ms (±0.244) and P3 2.41 ms (±0.329). Peak latencies correlated positively with tumor extensions (p < 0.005). CONCLUSIONS: This study provides clear instructions on optimal EABR performance and evaluation. SIGNIFICANCE: The new EABR Classification Scheme relies on a fast "online" identification of vertex positive peaks at the estimated post-artifact phase. The variability in EABR morphology provides an individual snapshot of the actual structural and functional status of the brainstem.
RESUMO
Fitting cochlear implant (CI) users can be challenging. Anatomy-based fitting (ABF) maps may have the potential to lead to better objective and subjective outcomes than conventional clinically based fitting (CBF) methods. ABF maps were created via information derived from exact electrode contact positions, which were determined via post-operative high-resolution flat panel volume computer tomography and clinical fitting software. The outcome measures were speech understanding in quiet and noise and self-perceived sound quality with the CBF map and with the ABF map. Participants were 10 experienced bilateral CI users. The ABF map provided better speech understanding in quiet and noisy environments compared to the CBF map. Additionally, two approaches of reducing the frequency-to-place mismatch revealed that participants are more likely to accept the ABF map if their electrode array is inserted deep enough to stimulate the apical region of their cochlea. This suggests an Angular Insertion Depth of the most apical contact of around 720°-620°. Participants had better speech understanding in quiet and noise with the ABF map. The maps' self-perceived sound quality was similar. ABF mapping may be an effective tool for compensating the frequency-to-place mismatch in experienced bilateral CI users.
RESUMO
BACKGROUND: The benefit of hearing rehabilitation is often measured using audiological tests or subjective questionnaires/interviews. It is important to consider both aspects in order to evaluate the overall benefits. Currently, there is no standardized method for reporting combined audiological and patient reported subjective outcome measures in clinical practice. Therefore, this study focuses on showing the patient's audiological, as well as subjective outcomes in one graph using data from an existing study. METHOD: The present paper illustrated a graph presenting data on four quadrants with audiological and subjective findings. These quadrants represented speech comprehension in quiet (unaided vs. aided) as WRS% at 65 dB SPL, speech recognition in noise (unaided vs. aided) as SRT dB SNR, sound field threshold (unaided vs. aided) as PTA4 in dB HL, wearing time and patient satisfaction questionnaire results. RESULTS: As an example, the HEARRING graph in this paper represented audiological and subjective datasets on a single patient level or a cohort of patients for an active bone conduction hearing implant solution. The graph offered the option to follow the user's performance in time. CONCLUSION: The HEARRING graph allowed representation of a combination of audiological measures with patient reported outcomes in one single graph, indicating the overall benefit of the intervention. In addition, the correlation and consistency between some results (e.g., aided threshold and aided WRS) can be better visualized. Those users who lacked performance benefits on one or more parameters and called for further insight could be visually identified.
RESUMO
OBJECTIVES: In cochlear implantation, preoperative prediction of electrode position has recently gained increasing attention. Currently, planning is usually done by multislice CT (MSCT). However, flat-panel volume CT (fpVCT) and its secondary reconstructions (fpVCTSECO) allow for more precise visualization of the cochlea. Combined with a newly developed otological planning software, the position of every single contact can be effectively predicted. In this study it was investigated how accurately radiological prediction forecasts the postoperative electrode localization and whether higher image resolution is advantageous. METHODS: Utilizing otological planning software (OTOPLAN®) and different clinical imaging modalities (MSCT, fpVCT and fpVCTSECO) the electrode localization [angular insertion depth (AID)] and respective contact frequencies were predicted preoperatively and examined postoperatively. Furthermore, inter-electrode-distance (IED) and inter-electrode-frequency difference (IEFD) were evaluated postoperatively. RESULTS: Measurements revealed a preoperative overestimation of AID. Corresponding frequencies were also miscalculated. Determination of IED and IEFD revealed discrepancies at the transition from the basal to the middle turn and round window to the basal turn. All predictions and discrepancies were lowest when using fpVCTSECO. CONCLUSION: The postoperative electrode position can be predicted quite accurately using otological planning software. However, because of several potential misjudgments, high-resolution imaging, such as offered by fpVCTSECO, should be used pre- and postoperatively.
Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Implante Coclear/métodos , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Tomografia Computadorizada de Feixe Cônico , SoftwareRESUMO
The study aimed to develop a consensus classification system for the reporting of sound localization testing results, especially in the field of cochlear implantation. Against the background of an overview of the wide variations present in localization testing procedures and reporting metrics, a novel classification system was proposed to report localization errors according to the widely accepted International Classification of Functioning, Disability and Health (ICF) framework. The obtained HEARRING_LOC_ICF scale includes the ICF graded scale: 0 (no impairment), 1 (mild impairment), 2 (moderate impairment), 3 (severe impairment), and 4 (complete impairment). Improvement of comparability of localization results across institutes, localization testing setups, and listeners was demonstrated by applying the classification system retrospectively to data obtained from cohorts of normal-hearing and cochlear implant listeners at our institutes. The application of our classification system will help to facilitate multi-center studies, as well as allowing better meta-analyses of data, resulting in improved evidence-based practice in the field.
RESUMO
A platform to help clinicians ensure that hearing device candidates are informed about the benefits and drawbacks of their recommended treatment option would be of clinical counselling benefit because it could help each candidate form realistic expectations about life with their treatment option. Following the World Café approach, 54 participants (surgeons, audiologist, and researchers) generated lists of the benefits and drawbacks of each treatment option for single-sided deafness (SSD) and bone conduction (BC) solutions. They then prioritized the benefits and drawbacks. After the World Café, literature research was performed on each topic to check if the statements (on benefits and drawbacks) are supported by quality peer-reviewed publications. Each participant was surveyed to ensure a collective agreement was reached. The HEARRING Counselling 1.0 Platform was developed. Thus far, sections for SSD and BC solutions have been completed. Initial feedback has been highly positive. The platform will be expanded to cover middle ear implant solutions and cochlear implants. A plan is in place to ensure the information continues to be timely. The HEARRING Counselling 1.0 helps clinicians provide comprehensive information to candidates about their treatment option and thereby helps establish that candidates have realistic expectations about the benefits and drawbacks of device use.
RESUMO
OBJECTIVE: To evaluate a new methodological approach of applying anatomy-based fitting (ABF) in experienced cochlear implant (CI) users. PARTICIPANTS: Three experienced unilateral and bilateral CI users with postlingual hearing loss. INTERVENTION: Postoperative imaging, via a high-volume Dyna computed tomography, and exact electrode measurement positions were integrated into the clinical fitting software following a new procedure, which adapted individual frequency bandwidths within the audio processor. MAIN OUTCOME MEASURES: Speech perception in quiet and noise, clinical mapping, and self-perceived level of auditory benefit were assessed. RESULTS: For each CI user, ABF mapping provided better speech perception in quiet and in noise compared with the original clinical fitting mapping. In addition, ABF mapping was accepted in CI users despite unequal bilateral array insertion depths and lengths; however, acceptance was only established if the point of first electrode contact was less than 230 Hz. CONCLUSIONS: ABF mapping increased the acceptance in CI users with longer electrode arrays and in bilateral CI users who were unsatisfied with their device experience. A larger prospective, randomized investigation is currently underway to assess longitudinal outcomes with ABF mapping.
Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Humanos , Estudos Prospectivos , Implante Coclear/métodos , RuídoRESUMO
OBJECTIVES: The SONNET 2 audio processor features ambient noise reduction (ANR), transient-noise reduction (TNR), and adaptive intelligence (AI). The primary aim of this study was to evaluate if using these features improves speech perception in noise, subjective listening effort, and sound quality. DESIGN: In this prospective longitudinal study, twenty adult SONNET users were fitted with the SONNET 2 audio processor, configured either as a default SONNET (no ANR/TNR/AI), with mild ANR/TNR, with strong ANR/TNR, with mild AI, and with strong AI. Speech perception in noise was assessed in speech and stationary noise from the front (S0N0); speech, stationary noise, and transient noise from the front (S0N0T0); and speech from the front in spatially-distributed stationary noise (S0N±45N±135). Listening effort, subjective sound quality, and device/setup preference were assessed. RESULTS: In the S0N0 setup, speech perception in noise was significantly better with the SONNET 2 when using ANR/TNR in the mild setup than with the SONNET or the SONNET 2 in the default SONNET configuration. In the S0N±45N±135 setup, speech understanding was significantly better in all four SONNET 2 configurations than with the SONNET or the SONNET 2 in the default SONNET configuration (a 1.26-2.55 dB SRT80 benefit). Subjects tolerated consistently lower signal-to-noise values with the SONNET 2 configurations using ANR/TNR than with the default SONNET configuration in all listening effort categories. All SONNET 2 configurations using ANR/TNR were preferred and better rated in speech in stationary and/or transient noise compared to the default SONNET configuration. Sound quality and pleasantness were better in those SONNET 2 configurations. Subjects strongly preferred the SONNET 2 configurations over the SONNET configuration. CONCLUSIONS: The new front-end features implemented in the SONNET 2 audio processor objectively improve speech perception in noise. Subjects preferred the SONNET 2, over the SONNET, in the presence of stationary and transient noise.
Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Humanos , Estudos Longitudinais , Estudos ProspectivosRESUMO
This proof of concept describes the use of evoked electromyographic (EMG) activation of the facial nerve for intraoperative monitoring of the electrode insertion during cochlear implantation (CI). Intraoperative EMG measurements from the facial nerve were conducted in nine patients undergoing CI implantation. Electric current pulses were emitted from contacts on the CI array during and immediately after electrode insertion. For control, the results of EMG measurements were compared to postoperative flat panel volume computed tomography scans with secondary reconstruction (fpVCTSECO). During insertion, the EMG response evoked by the electrical stimulation from the CI was growing with the stimulating contact approaching the facial nerve and declined with increasing distance. After full insertion, contacts on the apical half of the CI array stimulated higher EMG responses compared with those on the basal half. Comparison with postoperative imaging demonstrated that electrode contacts stimulating high EMG responses had the shortest distances to the facial nerve. It could be demonstrated that electrically evoked EMG activation of the facial nerve can be used to monitor the progress during CI electrode insertion and to control the intracochlear electrode position after full insertion.
Assuntos
Implante Coclear , Implantes Cocleares , Cóclea/diagnóstico por imagem , Cóclea/fisiologia , Cóclea/cirurgia , Implante Coclear/métodos , Nervo Coclear/fisiologia , Estimulação Elétrica , Nervo Facial/fisiologia , HumanosRESUMO
OBJECTIVES: The 59-item Work Rehabilitation Questionnaire (WORQ) was developed based on the International Classification of Functioning, Disability and Health (ICF) core set for vocational rehabilitation to assess work related functioning. It was revised to include 17 questions, assigned to 14 ICF categories relevant to cochlear implant (CI) users. This cross-sectional multicenter study aimed to evaluate CI users' responses on the WORQ questions to describe and generate ICF qualifiers for the revised WORQ in CI users, forming part of a broader framework of CI outcome measures linked to the ICF. METHODS: One hundred seventy-seven adults over the age of 18âyears with a minimum of one year's device experience were included in the analysis. The WORQ was completed by the participants at a routine visit to the clinic, via email, or via post. RESULTS: Most of the CI users perceived no problem on the WORQ questions (53.7%-91%), finished secondary school (54.2%) or obtained a college or university degree (32.8%) and are either employed (41.2%) or retired (34.5%). CI users that are currently working mostly have a full-time position (34.5%). Subjects reported no problem (91%) with sensation of falling, while handling communication devices and techniques (10.9%) and tinnitus (9.6%) showed the highest number of subjects reporting a complete problem. CONCLUSIONS: Overall, most of the CI users experienced no impairment, restriction or limitation on the WORQ questions and their assigned ICF categories. Their education level resembles the education level of the general population and they seem to integrate or reintegrate well in professional life postoperatively.
Assuntos
Implantes Cocleares , Avaliação da Deficiência , Atividades Cotidianas , Adulto , Estudos Transversais , Humanos , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Inquéritos e QuestionáriosRESUMO
PURPOSE: Audiology is an essential service for some patient groups and some interventions. This article sets forth experience-based recommendations for how audiological centers can continue to safely and effectively function during COVID-19. METHODS: The recommendations are the result of panel discussion and are based on the clinical experience of the panelists/authors. RESULTS: The recommendations cover which patient groups and which interventions should be treated when and whether this can be performed in the clinic or remotely; how to maintain the safety of workplace via optimizing patient flow within the clinic and the sanitation of rooms and equipment; and overcoming communication challenges that COVID-19 intensifies. CONCLUSION: For essential audiological services to continue under COVID-19, safety measures must be implemented and maintained, and treatment and communication strategies must be adapted to offset communication difficulties due to personal protective equipment (PPE) and social distancing and to bolster patient confidence. In short, it is vital that staff feel safe, that patients either feel the clinic is safe enough to visit or that remote treatment may be an option, and that clinics and patients have a broad agreement on the urgency of any needed service. We hope that these recommendations help clinics effectively accomplish these goals.
Assuntos
Audiologia , COVID-19 , COVID-19/prevenção & controle , Prova Pericial , Humanos , Equipamento de Proteção Individual , SARS-CoV-2RESUMO
PURPOSE: For further improvements in cochlear implantation, the measurement of the cochlear duct length (CDL) and the determination of the electrode contact position (ECP) are increasingly in the focus of clinical research. Usually, these items were investigated by multislice computed tomography (MSCT). The determination of ECP was only possible by research programs so far. Flat-panel volume computed tomography (fpVCT) and its secondary reconstructions (fpVCTSECO) allow for high spatial resolution for the visualization of the temporal bone structures. Using a newly developed surgical planning software that enables the evaluation of CDL and the determination of postoperative ECP, this study aimed to investigate the combination of fpVCT and otological planning software to improve the implementation of an anatomically based cochlear implantation. METHODS: Cochlear measurements were performed utilizing surgical planning software in imaging data (MSCT, fpVCT and fpVCTSECO) of patients with and without implanted electrodes. RESULTS: Measurement of the CDL by the use of an otological planning software was highly reliable using fpVCTSECO with a lower variance between the respective measurements compared to MSCT. The determination of the inter-electrode-distance (IED) between the ECP was improved in fpVCTSECO compared to MSCT. CONCLUSION: The combination of fpVCTSECO and otological planning software permits a simplified and more reliable analysis of the cochlea in the pre- and postoperative setting. The combination of both systems will enable further progress in the development of an anatomically based cochlear implantation.