Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 16(19)2023 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-37834717

RESUMO

This study aimed to assess the cyclic load capacity of wooden chairs and subsequently categorize them based on their performance. A diverse selection of chair models was randomly procured from commercial markets. These chairs underwent performance testing, utilizing the cyclic stepped increasing loading method, with adherence to the standards set forth by the American Library Association Technology Reports (ALA). The study evaluated 315 chairs, encompassing 21 chair models. Each chair model underwent five replications of testing across three different loading directions. The resulting dataset of numerical values was subjected to statistical analyses, facilitating the categorization of chairs based on their strength under cyclic loads. Notably, the study revealed substantial variations in the load capacity among different chair models. As a consequence of this investigation, the study established acceptable design load thresholds. For instance, concerning front-to-back loading, it was determined that the chairs with cyclic load capacities ranging from 932 to 1449 N fell within the category of low-strength, between 1450 and 1968 N were classified as medium-strength (suitable for domestic use), and the chairs with cyclic load capacities exceeding 1968 N were considered to possess high strength (intended for hotel lobbies, restaurants, libraries, etc.). Similarly, for back-to-front loading performance, the study identified the chairs with cyclic load capacities between 625 and 895 N as low-strength, 896 and 1167 N as medium-strength, and the chairs with loads surpassing 1168 N as high-strength. The performance thresholds for side thrust loads were as follows: low-strength encompassed the cyclic load capacities ranging from 649 to 934 N, medium-strength spanned the cyclic load capacities between 935 and 1221 N, and high-strength entailed 1222 N and above. Notably, the classification devised in this study is closely aligned with the widely accepted and internationally recognized ALA specification. This strong consistency with global standards reinforces the reliability and applicability of the classification system developed in this research. In conclusion, this study enhances understanding of wooden chair strength performance and offers practical insights that lead to higher-quality products and improved consumer satisfaction. Its recommendations can potentially drive positive change within the industry and benefit manufacturers and consumers.

2.
Materials (Basel) ; 16(13)2023 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-37444860

RESUMO

Tests were carried out to develop and manufacture various types of auxetic dowels using 3D printing technology. These dowels were then used to connect L-type corner joint specimens for case furniture, and their strength and stiffness were analyzed through experimental, theoretical, and numerical means. In the scope of the study, eight different types of auxetic dowels including two inclusion types, two inclusion sizes, and two dowel hole diameters, as well as a reference non-auxetic dowel, were designed. Accordingly, a total of 180 specimens that included 10 replications for each group were tested; 90 were tested under tension and the remaining 90 were tested under compression. The results demonstrated that the assembly force required for the corner joints connected with auxetic dowels was significantly lower compared to non-auxetic dowels. Furthermore, the numerical and theoretical analyses yielded similar outcomes in this study. Both analyses revealed that the dowels used to connect the corner joints experienced substantial stresses during mounting and bending, ultimately leading to their failure. Upon concluding the test results, it was observed that the corner joints connected with dowels featuring rectangular inclusions exhibited superior performance when compared to those with triangular inclusions. In light of these findings, it can be concluded that further enhancements are necessary for auxetic dowels with rectangular inclusions before they can be utilized as alternative fasteners for traditional dowels.

3.
Materials (Basel) ; 16(7)2023 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-37049131

RESUMO

In this study, the aim was to optimize the cross-sectional geometry of auxetic dowels for furniture joints. For this purpose, two different sizes of auxetic dowels were chosen, one for frame- and the other for panel-type furniture joints for designing the cross-sectional geometry. Auxetic patterns that are created on the cross-sectional area cause deficiency of the materials, and this phenomenon decreases the modulus of elasticity (MOE) and increases the member stress. Accordingly, maximum MOE values and minimum Poisson's ratio levels were determined for the optimum strength-auxetic behavior relation by means of a Monte Carlo method. Furthermore, Poisson's ratio of the optimized dowel's cross-section was confirmed with experimental tests, numerical analyses and analytical calculations. As a result, Poisson's ratio values were obtained as negative values and confirmed, which means the dowels designed in this study had auxetic behavior. In conclusion, it could be said that studies should be conducted on the performance of auxetic dowels in both frame and panel furniture joints.

4.
Materials (Basel) ; 14(23)2021 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-34885279

RESUMO

This study aimed to numerically and experimentally analyze the effects of internal mounting forces and selected materials on the stiffness and bending moment capacity of L-type corner joints connected with novelty-designed 3D printed fasteners. The experiments were carried out using medium-density fiberboard, high-density fiberboard, beech plywood, particleboard, and beech (Fagus silvatica L.) wood. The results showed that the joints made of beech wood were characterized by the largest bending moment capacity (12.34 Nm), while the worst properties were shown by particleboard (2.18 Nm). The highest stiffness was demonstrated by plywood joints (6.56 kNm/rad), and the lowest by particleboard (0.42 kNm/rad). Experimental studies have reasonably verified the results of numerical calculations. The test results confirmed that the geometry of new fasteners promotes the mounting forces under the assembly of the joints. It was shown that the higher the density of the materials, the greater the value of the mounting forces (164 N-189 N).

5.
Materials (Basel) ; 13(19)2020 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-32987710

RESUMO

Studies on the application of the auxetic metamaterials and structures in furniture joints are very limited. However, they have huge potential for use in ready-to-assemble furniture. This study aimed to design and produce different types of auxetic dowels in 3D printing technology, and experimentally and numerically analyze the withdrawal strength of these dowels. In the scope of the study, 24 auxetic dowels with different types and size of inclusions, a different diameter of holes, and a non-auxetic reference dowel were designed and produced with appropriate muffs. Dowels were 3D printed from polyamide (PA12). Poisson's ratios, withdrawal strength, contact pressures, and friction coefficients of dowels were determined theoretically by means of numerical analyses and real static compression tests. After the pre-production of dowels, the dowels with triangular inclusions have not been found to have sufficient strength and stiffness. Withdrawal strength of dowels decreased as the size of inclusions is decreased, or dowel hole diameter is increased. Furthermore, contact pressures and stresses in auxetic dowels were considerably lower than non-auxetic dowels under the withdrawal force.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA