Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
IEEE Trans Med Imaging ; 43(8): 3013-3026, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39088484

RESUMO

Accurate motion estimation at high acceleration factors enables rapid motion-compensated reconstruction in Magnetic Resonance Imaging (MRI) without compromising the diagnostic image quality. In this work, we introduce an attention-aware deep learning-based framework that can perform non-rigid pairwise registration for fully sampled and accelerated MRI. We extract local visual representations to build similarity maps between the registered image pairs at multiple resolution levels and additionally leverage long-range contextual information using a transformer-based module to alleviate ambiguities in the presence of artifacts caused by undersampling. We combine local and global dependencies to perform simultaneous coarse and fine motion estimation. The proposed method was evaluated on in-house acquired fully sampled and accelerated data of 101 patients and 62 healthy subjects undergoing cardiac and thoracic MRI. The impact of motion estimation accuracy on the downstream task of motion-compensated reconstruction was analyzed. We demonstrate that our model derives reliable and consistent motion fields across different sampling trajectories (Cartesian and radial) and acceleration factors of up to 16x for cardiac motion and 30x for respiratory motion and achieves superior image quality in motion-compensated reconstruction qualitatively and quantitatively compared to conventional and recent deep learning-based approaches. The code is publicly available at https://github.com/lab-midas/GMARAFT.


Assuntos
Aprendizado Profundo , Coração , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Coração/diagnóstico por imagem , Algoritmos , Artefatos , Movimento/fisiologia , Tórax/diagnóstico por imagem , Adulto
5.
Magn Reson Imaging ; 109: 256-263, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38522623

RESUMO

PURPOSE: Joint bright- and black-blood MRI techniques provide improved scar localization and contrast. Black-blood contrast is obtained after the visual selection of an optimal inversion time (TI) which often results in uncertainties, inter- and intra-observer variability and increased workload. In this work, we propose an artificial intelligence-based algorithm to enable fully automated TI selection and simplify myocardial scar imaging. METHODS: The proposed algorithm first localizes the left ventricle using a U-Net architecture. The localized left cavity centroid is extracted and a squared region of interest ("focus box") is created around the resulting pixel. The focus box is then propagated on each image and the sum of the pixel intensity inside is computed. The smallest sum corresponds to the image with the lowest intensity signal within the blood pool and healthy myocardium, which will provide an ideal scar-to-blood contrast. The image's corresponding TI is considered optimal. The U-Net was trained to segment the epicardium in 177 patients with binary cross-entropy loss. The algorithm was validated retrospectively in 152 patients, and the agreement between the algorithm and two magnetic resonance (MR) operators' prediction of TI values was calculated using the Fleiss' kappa coefficient. Thirty focus box sizes, ranging from 2.3mm2 to 20.3cm2, were tested. Processing times were measured. RESULTS: The U-Net's Dice score was 93.0 ± 0.1%. The proposed algorithm extracted TI values in 2.7 ± 0.1 s per patient (vs. 16.0 ± 8.5 s for the operator). An agreement between the algorithm's prediction and the MR operators' prediction was found in 137/152 patients (κ= 0.89), for an optimal focus box of size 2.3cm2. CONCLUSION: The proposed fully-automated algorithm has potential of reducing uncertainties, variability, and workload inherent to manual approaches with promise for future clinical implementation for joint bright- and black-blood MRI.


Assuntos
Meios de Contraste , Gadolínio , Humanos , Estudos Retrospectivos , Cicatriz/diagnóstico por imagem , Inteligência Artificial , Miocárdio/patologia , Imageamento por Ressonância Magnética/métodos
6.
IEEE Trans Med Imaging ; 43(7): 2420-2433, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38354077

RESUMO

In cardiac CINE, motion-compensated MR reconstruction (MCMR) is an effective approach to address highly undersampled acquisitions by incorporating motion information between frames. In this work, we propose a novel perspective for addressing the MCMR problem and a more integrated and efficient solution to the MCMR field. Contrary to state-of-the-art (SOTA) MCMR methods which break the original problem into two sub-optimization problems, i.e. motion estimation and reconstruction, we formulate this problem as a single entity with one single optimization. Our approach is unique in that the motion estimation is directly driven by the ultimate goal, reconstruction, but not by the canonical motion-warping loss (similarity measurement between motion-warped images and target images). We align the objectives of motion estimation and reconstruction, eliminating the drawbacks of artifacts-affected motion estimation and therefore error-propagated reconstruction. Further, we can deliver high-quality reconstruction and realistic motion without applying any regularization/smoothness loss terms, circumventing the non-trivial weighting factor tuning. We evaluate our method on two datasets: 1) an in-house acquired 2D CINE dataset for the retrospective study and 2) the public OCMR cardiac dataset for the prospective study. The conducted experiments indicate that the proposed MCMR framework can deliver artifact-free motion estimation and high-quality MR images even for imaging accelerations up to 20x, outperforming SOTA non-MCMR and MCMR methods in both qualitative and quantitative evaluation across all experiments. The code is available at https://github.com/JZPeterPan/MCMR-Recon-Driven-Motion.


Assuntos
Algoritmos , Coração , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Coração/diagnóstico por imagem , Coração/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Artefatos
7.
Magn Reson Med ; 92(1): 289-302, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38282254

RESUMO

PURPOSE: To estimate pixel-wise predictive uncertainty for deep learning-based MR image reconstruction and to examine the impact of domain shifts and architecture robustness. METHODS: Uncertainty prediction could provide a measure for robustness of deep learning (DL)-based MR image reconstruction from undersampled data. DL methods bear the risk of inducing reconstruction errors like in-painting of unrealistic structures or missing pathologies. These errors may be obscured by visual realism of DL reconstruction and thus remain undiscovered. Furthermore, most methods are task-agnostic and not well calibrated to domain shifts. We propose a strategy that estimates aleatoric (data) and epistemic (model) uncertainty, which entails training a deep ensemble (epistemic) with nonnegative log-likelihood (aleatoric) loss in addition to the conventional applied losses terms. The proposed procedure can be paired with any DL reconstruction, enabling investigations of their predictive uncertainties on a pixel level. Five different architectures were investigated on the fastMRI database. The impact on the examined uncertainty of in-distributional and out-of-distributional data with changes to undersampling pattern, imaging contrast, imaging orientation, anatomy, and pathology were explored. RESULTS: Predictive uncertainty could be captured and showed good correlation to normalized mean squared error. Uncertainty was primarily focused along the aliased anatomies and on hyperintense and hypointense regions. The proposed uncertainty measure was able to detect disease prevalence shifts. Distinct predictive uncertainty patterns were observed for changing network architectures. CONCLUSION: The proposed approach enables aleatoric and epistemic uncertainty prediction for DL-based MR reconstruction with an interpretable examination on a pixel level.


Assuntos
Aprendizado Profundo , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Incerteza , Algoritmos , Encéfalo/diagnóstico por imagem , Bases de Dados Factuais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA