Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Assunto principal
Intervalo de ano de publicação
1.
J Comput Assist Tomogr ; 47(2): 212-219, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36790870

RESUMO

PURPOSE: To assess deep learning denoised (DLD) computed tomography (CT) chest images at various low doses by both quantitative and qualitative perceptual image analysis. METHODS: Simulated noise was inserted into sinogram data from 32 chest CTs acquired at 100 mAs, generating anatomically registered images at 40, 20, 10, and 5 mAs. A DLD model was developed, with 23 scans selected for training, 5 for validation, and 4 for test.Quantitative analysis of perceptual image quality was assessed with Structural SIMilarity Index (SSIM) and Fréchet Inception Distance (FID). Four thoracic radiologists graded overall diagnostic image quality, image artifact, visibility of small structures, and lesion conspicuity. Noise-simulated and denoised image series were evaluated in comparison with one another, and in comparison with standard 100 mAs acquisition at the 4 mAs levels. Statistical tests were conducted at the 2-sided 5% significance level, with multiple comparison correction. RESULTS: At the same mAs levels, SSIM and FID between noise-simulated and reconstructed DLD images indicated that images were closer to a perfect match with increasing mAs (closer to 1 for SSIM, and 0 for FID).In comparing noise-simulated and DLD images to standard-dose 100-mAs images, DLD improved SSIM and FID. Deep learning denoising improved SSIM of 40-, 20-, 10-, and 5-mAs simulations in comparison with standard-dose 100-mAs images, with change in SSIM from 0.91 to 0.94, 0.87 to 0.93, 0.67 to 0.87, and 0.54 to 0.84, respectively. Deep learning denoising improved FID of 40-, 20-, 10-, and 5-mAs simulations in comparison with standard-dose 100-mAs images, with change in FID from 20 to 13, 46 to 21, 104 to 41, and 148 to 69, respectively.Qualitative image analysis showed no significant difference in lesion conspicuity between DLD images at any mAs in comparison with 100-mAs images. Deep learning denoising images at 10 and 5 mAs were rated lower for overall diagnostic image quality ( P < 0.001), and at 5 mAs lower for overall image artifact and visibility of small structures ( P = 0.002), in comparison with 100 mAs. CONCLUSIONS: Deep learning denoising resulted in quantitative improvements in image quality. Qualitative assessment demonstrated DLD images at or less than 10 mAs to be rated inferior to standard-dose images.


Assuntos
Aprendizado Profundo , Humanos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Razão Sinal-Ruído
2.
Radiol Artif Intell ; 3(2): e200098, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33928257

RESUMO

PURPOSE: To train a deep learning classification algorithm to predict chest radiograph severity scores and clinical outcomes in patients with coronavirus disease 2019 (COVID-19). MATERIALS AND METHODS: In this retrospective cohort study, patients aged 21-50 years who presented to the emergency department (ED) of a multicenter urban health system from March 10 to 26, 2020, with COVID-19 confirmation at real-time reverse-transcription polymerase chain reaction screening were identified. The initial chest radiographs, clinical variables, and outcomes, including admission, intubation, and survival, were collected within 30 days (n = 338; median age, 39 years; 210 men). Two fellowship-trained cardiothoracic radiologists examined chest radiographs for opacities and assigned a clinically validated severity score. A deep learning algorithm was trained to predict outcomes on a holdout test set composed of patients with confirmed COVID-19 who presented between March 27 and 29, 2020 (n = 161; median age, 60 years; 98 men) for both younger (age range, 21-50 years; n = 51) and older (age >50 years, n = 110) populations. Bootstrapping was used to compute CIs. RESULTS: The model trained on the chest radiograph severity score produced the following areas under the receiver operating characteristic curves (AUCs): 0.80 (95% CI: 0.73, 0.88) for the chest radiograph severity score, 0.76 (95% CI: 0.68, 0.84) for admission, 0.66 (95% CI: 0.56, 0.75) for intubation, and 0.59 (95% CI: 0.49, 0.69) for death. The model trained on clinical variables produced an AUC of 0.64 (95% CI: 0.55, 0.73) for intubation and an AUC of 0.59 (95% CI: 0.50, 0.68) for death. Combining chest radiography and clinical variables increased the AUC of intubation and death to 0.88 (95% CI: 0.79, 0.96) and 0.82 (95% CI: 0.72, 0.91), respectively. CONCLUSION: The combination of imaging and clinical information improves outcome predictions.Supplemental material is available for this article.© RSNA, 2020.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA